| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹14.8 L+₹16,283 (1.11%)Rejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹15.0 L+₹37,771 (2.59%)Rejected-Finance 02 JAMEEWAR COMPLEX RING ROAD HANUMAN NAGAR GONDIA MAHARASHTRA 441614 | GONDIA | MAHARASHTRA | 441614 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹15.2 L+₹57,248 (3.92%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹15.3 L+₹65,063.50 (4.45%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
₹14.9 L
EMD Value
₹29,800
Closing Date
15 Jun 2024, 6:00 pmClosed
Sh Vikash Singh, AE (E/M), AGE(I) AF Manauri
AGE (I) AF MANAURI PRAYAGRAJ
REPAIR / MAINT OF LT PANEL, MCCB, BUS BAR, OH LINE WITH ALLIED SERVICES
2024_MES_654573_1
9168/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
MANAURI PRAYAGRAJ
As per tender document
7 documents required · 7 mandatory
₹500
AGE (I) AF MANAURI
₹29,800
Yes
23 Oct 2024
17 May 2024
17 Jun 2024
17 May 2024
15 Jun 2024
2 Jun 2024
Amount
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 630 Amps, rated Ultimate Shortcircuit Breaking Capacity 36 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site, along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 400 Amps, rated Ultimate Shortcircuit Breaking Capacity 36 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site, along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 320 Amps, rated Ultimate Shortcircuit Breaking Capacity 36 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 250 Amps, rated Ultimate Shortcircuit Breaking Capacity 36 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site, along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 200 Amps, rated Ultimate Shortcircuit Breaking Capacity 35 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site,along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 160 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site, along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 100 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site, along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F adjustable thermal and fixed magnetic setting based MCCB 4 Pole 63 Amps, rated Ultimate Shortcircuit Breaking Capacity 25 kA Icu at 415 V, rated service short circuit breaking capacity =100% Icu at 415 V (kA rms), frame LS type, extended copper terminals both site, along with spreader terminals, including taking out existing unserviceable / burnt MCCB from site complete all as specified and directed.
S&F Magnetic contactor 3 pole, in built auxiliary contacts 2 No, 2 NC, AC 3 duty rating at 500 Amp, 415 V, 50 Hz, AC coil up to frame 4 and AC/DC universal coil with smart ECM in built for frame 5 to frame 8 complete all as specified and directed.
Supply, install, testing and commissioning (in replacement) LT panel size 110 cm x 90 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front and rear openable with locking arrangement incl inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC work, prewired complete duly powder coated with comprising of the following :-
Supply, Installation, testing and commissioning (in replacement) out door type power factor improvement panel of capacity 75 KVAR size 1100 mm x 700 mm x 250 mm, fully type test according to IEC 61439-1&2, IEC 61921 including interconnection with LT panel with appropriate size of electric cable for Main panel factory made, weather proof, dust and vermin proof (IP 65) suitable for Humidity: up to 95%, Average daily temperature: +35°C max, Ambient temperature: -5°C to 45°C, 1100 V/660 V grade 3 phase 50 HZ AC supply floor mounted, fabricated out of 14 SWG MS sheet welded on 40 x 40 x 3 mm angle iron frame / base of appropriate size and having four Nos angle iron legs made out of 40 x 40 x 6mm, 60 cm long angle iron below frame with front door and back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles, lugs duly painted with grey epoxy powder coating after suitable chemical treatment, legs duly embedded in ground in PCC 1:3:6 of suitable size including locking arrangement suitable for mounting, with required sheet metal enclosures, thimbles, and all other electric incoming and outgoing connections with PVC insulated multi stranded flexible copper NYVIN cable of suitable size and PVC flexible conduit medium quality as required comprising of the following complete all as specified and directed.
S&F in replacement spares / parts as under of air circuit breaker 440 volt 50 to 60 HZs 4 poles 630 Amps rated, suitable make and model as per site with replacing by technical rep of authorized agency of OEM including servicing / oiling / greasing / cleaning etc all required for making serviceable as specified and directed. Make: Siemens / L&T / CG
All as per item No. 12.00 above but Hand operated handel with spring complete all as specified and directed.
All as per item No. 12.00 above but Gear motor (MCH) 50 to 60 Hzs 415 volts AC / DC as required complete all as specified and directed.
All as per item No. 12.00 above but On /off Indication contacts change over 5 Amp with lamps complete all as specified and directed.
All as per item No. 12.00 above but Servicing, oiling , cleaning repacing to minor spare such as spring, interlock, fingers male and female, push botton, on off switch etc all required to made serviceable by tech rep of OEM (origional eqpt manufacture) including other site required spares complete all as specified and directed.
Taking down old unserviceable DB and S&F Busbar chamber TPN current capacity 200 Amp 04 way horizontal type, total enclosed with porcelain Insulator and colour coated tinned copper bus bar with suitable size of legs including PCC work fixing on ground or on wall/pole with suitable size of clamp, Nut, bolts, suitable size of thimbles for connection etc. complete all as specified and directed.
Dismantling of ACSR conductor from poles of any size & capacity and removing unserviceable materials from site(s) complete all as specified and directed.
M&L for aluminium conductor, steel reinforced (ACSR) of any size as approved on HT/LT Poles including straining, binding to insulators with aluminium binding wire with connectors, etc, providing PVC sleeves for jumpers as in OH conductors complete all as specified and directed.
Fixing only serviceable ACSR conductor any type and dia as obtained from Serial Item No 14.00 above on HT/LT Poles including straining, binding to insulators with aluminium binding wire with connectors, etc, providing PVC sleeves for jumpers as in OH conductors complete all as specified and directed.
Dismantling of earth wire of any size /dia or GI conductor, cradle guarding.etc and removing from site(s) complete all as specified and as directed.
M&L for Galvanized steel continuous earth wire 3.15 mm or 4mm dia complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections flat, nuts, bolts, washers etc. and removing unserviceable materials from site(s) complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including two coats of aluminium paint over a coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
Fixing only serviceable 1100 Volt grade Pin type, porcelain, vitreous, white, brown insulator etc. as obtained from Serial Item No 14.00 above complete all as specified & as directed.
S&F in replacement shackle type, porcelain, vitreous, white brown or green insulator of size 75mm high and 90mm dia including galvanized mild steel straps of section 31mm x 3 mm, 12mm dia insulator bolts, nuts, washer etc for working pressure 1100 volts complete all as specified and as directed.
Fixing only serviceable 1100 Volt grade Shackle type, porcelain, vitreous, white, brown or green insulator etc. as obtained from Serial Item No 14.00 above complete all as specified & as directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified & directed. Note:- Punned thickness shall be considered for measurement purpose complete all as specified and directed.
M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cushioning in trenches for cable protection complete all as specified and directed.
Labour only for reuse of serviceable bricks obtained from item No 25.00 complete all as specified and directed.
M&L for cutting / boring to plinth protection / hard standing / road etc in suitable depth to across the GI pipe size upto 80 mm dia of bore for drawn through XLPE under ground cable for giving mechanical protection to cable complete all as directed. Note: Quoted rate shall be included the cost of required material for repairing to disturbed surface complete all as per existing site.
S&F in replacement galvainesd water tubing light grade 80 mm dia of bore with fix with pole / surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc complete all as specified and directed.
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 95 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed. Note: Excavation and earthwork will be measured and paid separately under respective items of BOQ.
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 70 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed. Note: Excavation and earthwork will be measured and paid separately under respective items of BOQ.
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 50 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands complete all as specified and as directed. Note: Excavation and earthwork will be measured and paid separately under respective items of BOQ.
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 25 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable cable and disposing off complete all as specified and as directed. Note: Excavation and earthwork will be measured and paid separately under respective items of BOQ.
Supply, laying, jointing, connecting and testing XLPE insulated PVC sheathed cable 1100V grade, conforming to IS-7098 (Part-I) of 1988, screened PVC bedded, armoured electric power cable, heavy duty multi-stranded aluminium conductor grade cross section area 3.5 core 16 Sqmm (earthed) complete all as specified, laid in trenches / fixed on walls/poles, passing through pipes, etc. including connecting up to DBs, etc. with required lugs, end terminal / cable glands including taking out/down old unserviceable Service wire and disposing off complete all as specified and as directed. Note: Excavation and earthwork will be measured and paid separately under respective items of BOQ.
M&L for Earthing complete (in replacement) with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead using GI earth strip in size 32 x6 mm means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and directed. Notes: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Supply, jointing, commissioning and testing in replacement heat shrinkable end termination /straight through jointing kit suitable for 1100 volt grade (Earthed) cable for outdoor type complete with jointing material and required accessories suitable for underground XLPE cable of size 4 Core x 95 Sqmm (earthed) complete all as specified and directed. Make: Denson / 3M / Raychem
Supply, jointing, commissioning and testing in replacement heat shrinkable end termination / straight through jointing kit suitable for 1100 volt grade (Earthed) cable for outdoor type complete with jointing material and required accessories suitable for underground XLPE cable of size 4 Core x 150 Sqmm (earthed) complete all as specified and directed. Make: Dension / 3M / Rahycam
S&F Rolled Miled steel Framed work as in top of temp bldg for fixing of air termination confirming to Fe 410-W (gde-E-250) quality-A with gusset plates, rails braces, etc. complete, drilled for fixing of steel sheeting or other covering and hanging and fixing including taking out rusted frame complete all as specified and directed.
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3023038)
M/S R S Traders (BID ID -3019831)
M/s Techno India and Company (BID ID -3022526)
HIMANSHU TRADERS (BID ID -3022940)
M/S Aarav Construction (BID ID -3022203)
M/S SHIV BALLABH MISHRA (BID ID -3021788)
Avion Industries (BID ID -3029067)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .