Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | ₹1.9 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.0 Cr+₹3.8 L (1.94%)Rejected-Finance OFFICE NO 2 GROUND FLOOR CO OP HSG SOCIETY SBS ROAD COLABA MARKET MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹2.0 Cr+₹3.8 L (1.94%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹2.2 Cr+₹21.1 L (10.9%)Rejected-Finance GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | ₹2.2 Cr+₹21.1 L (10.9%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹2.2 Cr+₹23.3 L (12.0%)Rejected-Finance 602 6TH FLOOR BNG HOUSE D N ROAD FORT MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | ₹2.2 Cr+₹23.3 L (12.0%) | L4 | Rejected-Finance Other than being lowest |
| 5 | L5₹2.4 Cr+₹45.3 L (23.3%)Rejected-Finance NOT AVAILABLE | ₹2.4 Cr+₹45.3 L (23.3%) | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹2.6 Cr
EMD Value
₹3.3 L
Closing Date
9 Nov 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
ADDITIONAL/ALTERATION AND SEPCIAL REPAIRS TO BLDG NO P17A AT INS SHIKRA UNDER GE(NW) NOFRA, COLABA, MUMBAI
2024_MES_679395_1
8609/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
545 days
GE (NW) NOFRA
Class B
category a (i)
7 documents required · 7 mandatory
₹2,000
GE (NW) NOFRA
₹3.3 L
Yes
21 Dec 2024
14 Oct 2024
11 Nov 2024
14 Oct 2024
9 Nov 2024
4 Nov 2024
14 Oct 2024 - 2 Nov 2024
Amount
Taking down cement or cement lime plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed incl removal od debris outside MoD land Note: The place of disposal shall be found out by the contractor
Chipping, removing carefullly concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debris out side the premises etc. complete as directed by Engineer-in-Charge incl removal od debris outside MoD land Note:(i) The place of disposal shall be found out by the contractor. (ii) Hard concrete should not be removed by force.
Demolition of reinforced cement concrete of any description and in any position (reinforcement cut as required to facilitate demolition whenever required), complete all as specified and as directed incl removal od debris outside MoD land Note: The place of disposal shall be found out by the contractor
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles.
Material and labour for brick work with sub class "B" bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4), complete all as specified.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4), complete all as specified.
Material and labour for cleaning existing reinforcement with wire/rotary wire brush,making the surfaces free from loose material dirt etc, copmplete, applying two coats of alkaline rust converting primer FEOVERT or equivalent specification confirming to ASTM-B-117, on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating IPNET-RB complete all as specified and directed.
Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
Material & labour for carry out application of Bi-polar migratory corrosion inhibitor EPCO-KP-100/ Protectsil CIT/Ferogard 903 on concrete surface (this inhibitor shall have migratory kind of properly which permits the material to migrate to a virtual extent of 100 mm, through pores of concrete, inhibitor the corrosion and de-passivating the Electro-chemical reaction. It should have properly to attack as well as cathode, which is purely alkaline in nature (pH-9.5), So it has no carcinogen activity with concrete all as per manufacturer's instructions and directed.
Material & labour for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for minimum 12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the crack with a liberal application of the epoxy putty.
Material & labour for Injecting of cement slurry grout, in the ratio 1:2 (1-cement 2-water) including super plasticizer (supercom-100) 250 ml/50 Kgs. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/sqcm till the grout mix flow out from the nozzle indicating complete filling of grout in the holes drilled.
Material & labour for Injecting low viscosity MONOPOL (3-5 cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of material components (part A & B) in the required quantities as per manufacture`s instruction by weigh batching, Grouting maintain the pressure at exit(0.5 to 1.0 kg/cm2) by monitoring pressure gauge at exit grout the material through prefixed nozzles in the structural elements@100ml per nozzle Repeat the process for all the nozzles. (Beam, RCC wall and columns)
Providing and applying structural grade EPIBOND-21-LP prior to application of any type of mortar plaster confirming to ASTM-C-882-91 (Arizona slant shear test) to ensure bond between old concrete and new concrete complete all as per manufacturer's instructions and as directed by Engineer-in-Charge
Building up the profile of structural member by using latex additives (MONOBOND) modified air cured mortar system (Polymer modified mortar/LW+) (1:5:15 = 1 monobond-5 cement -15 sand) -in damaged area in 30mm thickness including leveling profiling etc complete all as per manufacturer's instructions and as directed by Engineer-in-Charge
Providing and applying jacketing around columns with Micro concrete (Molith-MC) M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete. Note :- Reinforcement shall be measured and paid separately rates quoted shall be inclusive of jacketing, formwork and micro concrete etc complete all as specified.
Providing and applying fair finish 15mm thick plaster with ready mix prepacked proportioned dry mix mortar, mixed with water proofing compound on fair faces of brick wall or concrete surfaces, on internal surfaces including transporting of material, mixing, curing, etc. complete all as specified and directed by the Engineer-in-charge. Note :- Water proofing compound shall be measured and paid seperately as supply only.
Providing & applying anti algal water-based elastomeric exterior wall finish on newly plastered surfaces including surface preparation, applying suitable wall prime seal primer 8-10 sqm per ltr coverage area and application of two coats (base coat 4.2-4.7 & top coat 6-6.5 sqm per ltr coverage area ) & of paint by roller etc. complete all as specified and directed by the Engineer-in-charge. Notes:- 1. Work will be executed by authorised applicator of approved manufacturer. 2. Every coat of finish will be approved by GE before starting new layer/coat. 3. Contractor to submit minimum 05 yrs warranty certificate from the company.
Material & Labour for complete removal of existing treatment on walls/surface with wire brush/rotatry wire brush, watering, cleaning of surface and opening of cracks in V shape and filling with Dr. Fixit (Crack X Paste) or any other techno-commercial equivalent Make of Fosroc, Krishna Conchem, etc. as approved by the Engineer-in-charge and applying anti-algae water based elastomeric exterior wall finish as on old plastered surfaces including surface preparation, applying suitable wall prime seal primer 8-10 sqm per ltr coverage area and application of two coats (base coat 4.2 -4.7 & top coat 6-6.5 sqm per ltr coverage area) & of paint by roller etc. complete all as specified and directed by the Engineer-in-charge. Notes:- 1. Work will be executed by authorised applicator of approved manufacturer/OEM. 2. Every coat of finish will be approved by GE before starting new layer/coat. 3. Contractor to submit minimum 05 yrs warranty certificate from the OEM.
Providing and applying fair finish 15mm thick plaster with ready mix prepacked proportioned dry mix mortar, fair faces of brick wall or concrete surfaces, on internal surfaces including transporting of material, mixing, curing, etc. complete all as specified and directed by the Engineer-in-charge.
Providing and applying fair finish 10mm thick plaster with ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces additives, on ceiling including transporting of material, mixing, curing, etc. complete as per direction of Engineer-in-charge.
(a) Material & Labour for waterproof cement based putty @ 1 kg (undiluted) per sqm of average thickness 2 mm over the newly plastered surface of wall, after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps :- Step 1:- Mix the putty powder by adding water as per manufacturer's instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2:- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. Step 3:- Allow 6-8 hrs time to dry the putty surface. (b) Material & Labour for applying two coats of oil bound distemper over a coat of primer using fully automatic airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 Metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed by the Engineer-in-Charge. Note: Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application.
(a) Material & Labour for waterproof cement based putty @ 1 kg (undiluted) per sqm of average thickness 2 mm over the newly plastered surface of ceiling, after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps :- Step 1:- Mix the putty powder by adding water as per manufacturer's instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2:- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. Step 3:- Allow 6-8 hrs time to dry the putty surface. (b) Material & Labour for applying two coats of oil bound distemper over a coat of primer using fully automatic airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 Metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed by the Engineer-in-Charge. Note: Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application.
(a) Material & Labour for waterproof cement based putty @ 1 kg (undiluted) per sqm of average thickness 2 mm over the old plastered surface of ceiling, after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps :- Step 1:- Mix the putty powder by adding water as per manufacturer's instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2:- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. Step 3:- Allow 6-8 hrs time to dry the putty surface. (b) Material & Labour for applying two coats of oil bound distemper over a coat of primer using fully automatic airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 Metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed by the Engineer-in-Charge.
(a) Material & Labour for waterproof cement based putty @ 1 kg (undiluted) per sqm of average thickness 2 mm over the old plastered surface of wall, after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps :- Step 1:- Mix the putty powder by adding water as per manufacturer's instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2:- Apply the first coat of the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI. Step 3:- Allow 6-8 hrs time to dry the putty surface. (b) Material & Labour for applying two coats of oil bound distemper over a coat of primer using fully automatic airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 Metre. The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed by the Engineer-in-Charge. Note: Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper masking to be carried out before primer and paint application.
Supply and fixing for MS framed works as in grills, railings, brackets for chajjas etc, conforming to FE-290 Gde E-165
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.(Work is to be carried out in roof, sides/ edges of the sheets to be rounded/folded before fixing)
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 .
Material and labour for cement concrete 1:2:4 type B-2 (40mm graded stone aggregate) as in mass concrete all as specified and directed.
Taking down soil, rain water pipes (any size or pattern), including all fittings, heads,shoes,bends, swan-neck, etc. Including cleaning or refixing or removal to store ( measured over all as fixed along the center line over fittings and accessories)
Supply and fixing 110 mm dia PVC (SWR) grade pipes, single socketed in any length with rubber ring joints fixed to walls / laid in trenches with and including and including fixing of pipes in wall with clamps as mentioned and shown in HQ CE (N) Mumbai zone TD Drg No TD/2023/01 toTD/2023/03 complete all as specified and directed.
Supply and fixing in repairs110 mm dia PVC (SWR) grade single Y, with access doors including fixing clips.
Supply and fixing in repairs110 mm dia PVC (SWR) grade single T with access doors including fixing clips.
Supply and fixing in repairs 110 mm dia bore PVC (SWR) bends any radius
Dismantling of 100mm cast iron or reinforced concrete drain pipes, jointed in cement mortar, complete all as specified.
S&F 100 mm bore of sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall and including fixing of pipes in wall with clamps as mentioned and shown in HQ CE (N) Mumbai zone TD Drg No TD/2023/01 toTD/2023/03 complete all as specified.
Dismantling of 75mm cast iron or reinforced concrete drain pipes, jointed in cement mortar, complete all as specified.
S&F 75mm bore of sand cast CI soil waste pipe in any length with ears and jointed with neat cement paste fixed to wall and including fixing of pipes in wall with clamps as mentioned and shown in HQ CE (N) Mumbai zone TD Drg No TD/2023/01 toTD/2023/03 complete all as specified.
M&L in repair 75mm cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) including grating jalli complete all as specified and as directed.
S&F 75mm sand cast CI Branch pieces (Tee), Single (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge.
S&F 100mm sand cast CI Branch pieces (Tee), Single (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall, complete all as specified.
S&F 75mm sand cast CI Branch pieces (Tee), Double (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge.
S&F 100mm sand cast CI Branch pieces (Tee), Double (equal), ordinary or inverted (spigot or socket type) or with parallel branches with ovel access door and jointed with neat cement paste to CI pipes fixed to wall , complete all as specified.
S&F in repair 100mm CI ‘P’ or ‘S’ Traps jointed with neat cement paste fixed to wall or roof at any floor/ any height/ any location including all fittings complete all as specified and as directed by Engr-in-Charge.
S&F in repair cast iron cowl suitable for 75mm dia pipe , complete all as specified.
S&F in repair cast iron cowl suitable for 100mm dia pipe, complete all as specified.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing, complete all as specified.
Taking up or down 20mm bore steel tubing and connections,complete all as specified.
Taking up or down 25mm bore steel tubing and connections, complete all as specified.
Taking up or down 50mm bore steel tubing and connections, complete all as specified.
Supply & Fixing 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed on walls/ceiling/laying in floors including fixing of pipes in wall with clamps as mentioned and shown in HQ CE (N) Mumbai zone TD Drg No TD/2023/01 toTD/2023/03 complete all as specified and directed by the Engineer-in-charge. Note:- Marking to be done with permanent marker showing the concealed pipe line to avoid breakage/damage in future. Drawing of internal pipe line (kitchen, Bath, Toilet etc.) to be submitted by the contractor.
S&F 25mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified.
S&F 50mm bore steel water tubes, medium grade, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified.
S&F in repairs fancy type Pillar Tap with left hand operating Knob with 450mm long braided hose conforming to CQT-CHR-23123 respectively of JAQUAR or techno-commercial equivalent of Parryware, Hindware or make given in Appx B as approved, cast copper alloy , with capstan heads, chromium plated , screwed down high pressure ,with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
S&F as in repairs 15mm fancy type chromoum plated Bib taps, Cat Part No.CQT-CHR-23037 of Jaquar or techno-commercial equivalent of Parryware or Hindware or make given in Appx B as approved cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S & F in repairs stop valve /angle valve fancy type Cat Part No.CQT-CHR-23053 of Jaquar or techno-commercial equivalent of Parryware or Hindware or make given in Appx B as approved chromium plated screwed down, high presure with butterfly handle screwed both ends for pipe and fixed to pipe of 15mm dia bore complete all as specified and as directed.
S & F in repairs concealed stop cock (composite one piece body) with cartridge (Cat part No. ALD-CHR--083 of Jaquar or techno-commercial equivalent of Parryware or Hindware as approved or make given in Appx B ) including suitable exposed part kit complete and fixed to pipes, complete all as specified and as directed.
S & F in repairs vitreous china wash down, white, water closet pan (Wall Hung pedestal pattern) with 'P' or 'S' trap with soft close seat cover, hinges, accessories set, size 365x545x360mm Cat part No. CNS-WHT-961SPP of Jaquar or techno-commercial equivalent of Parryware or Hindware as approved or make given in Appx B with P or S trap, closed pattern with flat bottom & cover and chromium plated mild steel or aluminium anodized hinging device including connecting to trap and flushing pipe, anti-syphonage pipe etc and screwed with brass screws to sheesham wood plugs embedded in floor complete all as specified and directed.
M&L as in repair Vitreous water closet (Squatting pan, Orissa pattern, size 575 x 440x250mm Cat Part No ECS-WHT-451LE in Jaquar or techno-commercial equivalent of Parryware or Hindware as approved or make given in Appx B white, with integral foot rests and 'P' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding complete all as specified and directed.
S&F counter top Thin rim type Vitreous china wash basin, white matt , rectangular shape of size 525mm x 415mm x 140mm Jaquar Cat Part No. JDS-WHT-25907N or techno-commercial equivalent of Parryware or Hindware as approved or make given in Appx B including waste cupling brass chromium plated including bottle trap, complete all as specified.
S&F vitreous china urinal of size 480x 300x 740mm Jaquar Cat Part No. URS-WHT-13255 and Jaquar Cat Part No. SNR-CHR-51097 or techno-commercial equivalent of Parryware or Hindware or make given in Appx B with all fittings accessories including sensor flushing valve chrominum finish for urinal with complete kit (battery opearated ), complete all as specified.
S&F curved shaped urinal partition with 8mm thick frosted glass of size 90mmx 450mm including Jaquar Cat Part No. JSE-CHR-810VC450X or techno-commercial equivalent of Parryware or Hindware or make given in Appx B all fittings/ brackets required to fit over wall, complete all as specified.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm complete all as specified and as directed.
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic Twin flushing cistern conforming to Cat Part No. ESH-WHT-184NL of Jaquar or techno-commercial equivalent of Parryware or Hindware or make given in Appx B as per IS 7231: 1994 as aprroved with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S&F as in repairs brass chromium plated shower rose 100mm dia including 160mm long shower arm casted body round shape for wall mounted shower Cat Part No.OHS-CHR-1989 and Cat Part No.SHA-CHR-477 respectively of Jaquar or techno-commercial equivalent of Parryware or Hindware as approved or make given in Appx B , including fixed to 15mm bore pipe, complete all as specified and directed.
S&F as in repairs Health faucet (ABS Body) Cat Part No. ALD-CHR-587 of Jaquar or techno-commercial equivalent of Parryware or Hindware or make given in Appx B as aprroved mild steel chromium plated suitable for 15 mm dia pipe with 1.00 metre long spirochrome Flexible tube and wall hook including making connections and fixed in position complete all as specified and directed.
S&F in repairs Stainless steel Towel rack 600mm long Cat Part No ACN-CHR-1181FS of Jaquar or techno-commercial equivalent of Parryware or Hindware or make given in Appx B as approved including necessary brackets complete all as specified and as directed.
S&F in repairs low density polyethylene pipes (LDPE) of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc for outlet of washing machine/wash basin etc of 40mm dia bore complete all as specified and as directed.
S&F 2000 lit capacity rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top ) hoisted and fixed position all specified in SSR Part-I, with and including 50mm dia ball valve, high pressure of PTMT, with epoxy coated aluminium rod & high density plastic ball, minimum weight 210gm, screwed for iron pipes and fixed; including disconnecting and dismantling/ taking down of existing old unserviceable water storage tank above 5th floor terrace, complete all as specified and directed by Engineer-in-Charge.
Demolition of Cement concrete in any description and in any position not other wise specifically provided on terrace of bldg (above 5th floor) directed by Engineer-in-Charge and removal of debris to out side MD land as per guidelines of BMC.
Material and labour for cement concrete 1:2:4 type B-2 (40mm graded stone aggregate) by using WPC @ 2% of weight of cement as in floor of RCC roof all as specified and directed. Note: (WPC shall be paid seperately)
Providing and applying fair finish 10mm thick plaster with ready mix prepacked proportioned dry mix mortar fair faces of brick wall or concrete surfaces additive as on roof surface including transporting of material, mixing, curing, etc. complete as per direction of Engineer-in-charge.
Material and labour for cement 1:2:4 type B-0 (12.5mm graded stone aggregate) as in roof kerbs and leveling course on RCC roof surfaces all as specified and directed.
Removal of tree roots and branches spreed over stone wall/brick wall joints, injecting anti vegetation chemical and making good the stone/ brick wall joints by flush pointing in CM (1:4) including provision of necessary scafolding and removing the debris outside MD land.
Treatment of sunken floor slab comprising of the following specifications and all as specified :- (i) Material & labour for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely 40 mm thick avg PCC (1:2:4) type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost of cutting holes and pipes shall be measured and paid separately) (ii) Rendering of uneven surfaces with 6mm thick CM (1:4) mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting to be carried out. (WPC shall be measured & paid separately) (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) Material & labour for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.(This item shall be measured and paid separately) (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM (1:4) mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately) Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and shall be tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing shall be deemed to be included in the rates quoted above. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC (1:3:6) all round after painting with anticorrosive paint (This shall be measure & paid separetely).
M&L for Cutting holes in bricks or RCC walls exc half brick built in cement mortar including making good after inserting and setting spouts complete all as specified and directed.
S&F GI pipe 50mm dia medium grade laid in sunken floor complete all as specified and directed.
M&L PCC 1:7:12 type F2 (by using 40mm graded stone aggregate) as in lean concrete/filling concrete complete all as specified.
M&L 75mm thick plain cement concrete type D-2 (1:4:8) as in sub base, complete all as specified.
Material & labour for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level + 100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
Water Proofing Treatment to Sunken Floor are as under: - (a) Cleaning the surface of any description with wire brush, detecting sources of leakage/ seepages and removing/ taking down unsound treatment/ surface. (b) M&L for making holes with drill machine of dia 18mm for carrying out non-destructive waterproofing treatment to floors, sunken portion of toilet/ bathroom and junctions of floor and walls of bath/WC and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting with first course of injection MDI based PU foam and second course of injection with PU plain all as per manufacturers instruction etc and M&L for fixing the metallic packer for hydropobic PU foam sealer as per manufacturer specification. Note : The PU foam and PU plain shall have 100% solids and solvant free and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50D.
Taking down chowkats or frames n exc 1.5 sqm each with shutters (without taking off shutters from the frame), complete all as specified.
Taking down chowkats or frames exc 1.5 sqm each but n.exc 4 sqm with shutters (without taking off shutters from the frame)
Taking down shutters exc 1 sqm and n exc 2 sqm each.
S&F powder coated (colour of coating as directed) aluminium (minimum 50 micron thickness of coating) of various section as required/suitable for doors, window & partion/Ventilator (sliding /or openable type)etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like jointing cleats, glazing clips, rubber neoprene packing. anodised aluminium snap beading screws etc. rubber beading, clips locking arrangement, handle, sealant etc all as specified and as directed.
Supply & fixing aluminium anodised grill (minimum thickness of anodising 50 micron) with and including suitable aluminium anodized 'E'/'H' section frame as required with aluminium rebated/screwed attachment complete all as specified and directed complete all as specified and directed. Note:- Aluminium grill shall be of Deco grill of M/s ELESAR FOCCHI Ltd as per Design No DG 102, 7.50mm x 6.0mm and weight shall not be less than 3.131Kg/Sqm or approved design.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and directed.
S&F Factory made single extruded WPC (WoodPolymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed.
M&L factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screwsand as per specification & drawing complete all as specified and directed.
S&F in repairs 18/19 mm thick prelaminated partical board interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work including 6 mm thick teak wood beading all around complete all as specified and directed.
M&L 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed.
S&F 35mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides one face covered with decorative face veneer with lipping/ frame to match complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed.
S&F for aluminium anodized barrel tower bolts 200mm of extruded section and fixed.
S&F 150 mm size aluminium alloy handles, cast type anodised, ISI marked all as specified.
S&F 200 mm size aluminium alloy handles, cast type anodised, ISI marked all as specified.
S&F 100mm butt hinges medium weight, stainless steel and fixed.
S&F 125 mm long hasp and staple safety type aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
Preparation of new wooden surafces & applying two coats of synthetic enemal paint over a coat of pink primer, complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar, complete all as directed.
M&L for machine cut cudappa stone slab 20-25 mm thick laid over 15mm thick screed base in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed.
M&L Granite (of any type) work (table rubbed and polished) 20mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite., and nosing /rounding to edges of stone slabs one edge,all as specified and directed. (Note : Granite in double layers to be provided on window sills)
Preparation of new steel surafces & apply two coats of synthetic enemal paint over a coat of red oxide, complete all as specified.
Supply only Integral water proofing compound
Dismantling floor hearth or wall tiling including cement mortar bedding and removing serviceble tiles to store and rubbish off the permises.complete all as specified & as directed.
M&L for light shade coloured vitrified (DGVT) ceramic tiles 9-10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for light shade coloured vitrified (DGVT) ceramic tiles 9-10 mm thick (square/rectangular) polished area of each tiles exceeding 0.42 but not exceeding 1.00Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for light shade coloured vitrified (DGVT) ceramic tiles 9-10 mm thick (square/rectangular) polished area of each tiles not exceeding 0.36 Sqm in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, incl 15 mm thick backing coat in CM 1:4, complete all as specified and directed.
M&L for light shade coloured vitrified (DGVT) ceramic tiles 9-10 mm thick (square/rectangular) polished area of each tiles exceeding 0.42 but not exceeding 1.00 Sqm in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, incl 15 mm thick backing coat in CM 1:4, complete all as specified and directed.
M & L Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:6), complete all as specified.
M&L, Glazed ceramic tiles coloured of size 350x 250x 7 mm/ 450X 300X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick backing coat in CM 1:4 , complete all as specified.
M&L, for machine cut kota stone slab flooring 20-25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
M&L, for machine cut kota stone slab flooring 22-25mm thick in riser / treads of steps in single piece, skirting, dado and pillar laid over cement screed and jointed withover cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
Rounding to edges of stone slabs, such as in steps, cooking platform, and other similar situations, complete all as specified.
Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in floor or paving 75 mm thick and finished even and smooth without using extra cement, as in plinth protection all as specified
M&L for forming construction joint 50mm deep x 10mm wide filled with sealing compound Grade 'A' in plinth protection, complete all as specified.
M&L for Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in floors, all as specified.
M&L for fixing in repairs machine pressed pre cast concrete interlocking tiles of any shape & size confirming to IS 15658-2006 of 60mm thickness, M-35 graded with grey cement & pigment, (design pattern & colour as approved)
M&L for sand filling under floors or in foundation including watering and consolidation etc, complete all as specified .
S&F in repairs fancy type Stainless Steel drapery rods of 20-25mm size incl decorative brackets at the end and fixing in brick/ concrete surface with SS Screws complete all as specified and directed.
S&F in repairs door closer aluminium (Die cast) body hydraulically regulated, designation No 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed all as specified and directed.
Supply and fix as in repairs false ceiling with powder coated exposed GI grip suspension system (E-grip T-2430 or equivalent load carrying capacity with mid span deflection not exceeding. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross tee 1200mm/600mm long wall angle. The main runners to be placed @ 1200mm, the cross tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm from a modular grid of 1200mm x 600m. Additinoal cross tees of 600mm shall be placed perpedicular to the cross tee 1200mm long to finally form a grip of 600mm x 600mm. Grip of modular size 600mm x 600mm shall be supported by 6mm dia GI wire from purlins / soffit with and including 6mm thick high pressure steam cured non asbestos fiber and fixed as in repairs complete all as specified and as directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil.
Dismantling of 200mm reinforced concrete drain pipes, jointed in cement mortar, complete all as specified.
S&F for 200mm bore RCC pipe class NP-2 laid and jointed complete with collers as specified including testing all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in bed to drain pipes including forming cradle after they are laid and tested for 200mm bore RCC pipe complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in benching, coping, cills steps, parapets, railings up to 60cm in height, water troughs and the like rounded or chamfered on edges including necessary form work complete all as specified.
M&L, Extra for forming fair finished drain or channel 200mm inner girth in cement concrete, using ex-tra cement, including forms, moulds, mi-tred/stopped ends etc.
Cutting into existing manholes for connecting new drain making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 Sec) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as reqd for 200mm bore of pipe complete all as specified and directed.
Removal of excavated soils from site to distance exc1.50 Km but not exc 5 Km and depositing where directed , complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in Hard / dense soil, complete all as specified.
M&L providing and injecting chemical emulsion for post construction anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion at 2.25 litre per linear meter including drilling and plugging holes etc with white cement and match the surface to existing apron complete all as specified and as directed by Engineer-in-Charge.
M&L for treatment of soil under existing floors using chemical emulsion @ 1 litre per hole at 300mm apart and 300mm deep including drilling and plugging 12mm dia holes with cement mortar 1:2 or white cement to match the existing floors all as specified and directed by Engineer-in-Charge.
M&L for post construction treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement as specified and directed by the Engineerr-in-Charge.
S&F in repairs Cast iron work grade FG 150, machined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles machined each exceeding 5 Kg by weight complete all as specified and directed.
S&F as in repairs for aluminium anodized barrel tower bolts 200mm of extruded section and fixed complete all as specified and directed.
S&F in repairs 200 mm size aluminium alloy handles, cast type anodised, ISI marked all as specified.
S&F in repairs 100mm butt hinges medium weight, cold rolled mild steel and fixed.
S&F in repairs 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
Preparation of old wooden surfaces and apply one coat of synthetic enamel paint, complete all as specified.
S&F 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
S&F as in repairs 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor
S&F decorative glass corner shelf round 8mm thick, 300mm size with stainless steel railing, fixed with D type stainless steel bracket on wall of approved design and pattern complete all as specified and directed.
S&F as in repairs toilet paper holder Cat Part No.ACN-CHR-1153S of Jaquar or technocommercial equivalent of Parryware or Hindware of any make given in Appx B as aprroved with flat recessed type stainless steel complete all as specified and directed.
S&F decorative glass shelf 600mm long Cat Part No.ACN-CHR-1171N of Jaquar or technocommercial equivalent of Parryware or Hindware of any make given in Appx B, 8mm thick with Chromium Plated railing, fixed with D type stainless steel bracket on wall of approved design and pattern complete all as specified and directed.
S&F Stainless Steel Soap Dish Cat Part No.ACN-CHR-1131N of Jaquar or technocommercial equivalent of Parryware or Hindware of any make given in Appx B as approved fancy type fixed with two Steel/ CP Screws complete all as specified and directed
S&F as in repairs 15mm fancy type chromium plated Two way Bib taps, Cat Part No.CQT-CHR-23041 of Jaquar or technocommercial equivalent of Parryware or Hindware of any make given in Appx B as approved cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repairs 0.71mm thickness Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing, crumple joints and fixed to wall with screws all as specified and directed.
S&F number plate (Floor No), size of plate should be 250mm x 200mmx 2mm thick rectangular in shape made up of Stainless Steel (304), number and border of plate should be engraved/ itched and filled with black metallic colour. Four (04) numbers of holes to be provided for fixing with 04 numbers of round headed Chromium Plated Screws. Number plate to be fixed in front between both Lifts at each floor complete all as specified and directed.
S&F PVC wall panelling consisting of 5mm thick wood grain printed PVC sheet and fixed over GI running channels 50mm wide and 0.6mm thickness at every 1m interval, fixing over brickwall /concrete walls with screws and all corners, top and bottom portion of PVC lining covered with L/T shaped PVC sheet of same colour/texture including all necessary cuttings near switch boards and other fixtures if fitted over wall and including complete all as specified.
Supply and fix white rectangular PVC water storage tanks (Loft tank) of capacity 500 Ltrs including 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for inron pipe and fixed (minimum weight 210 grms ) including fixing 03 Nos tank nipples of GI with washer for out let and inlet all as per manufacturers instructions icomplete all as specified and directed.
M&L for Providing precast cement concrete louvres and jallies, Type B0 1:2:4 set in CM 1:4, 20-25mm thick (measured solid), including all mouldings complete all as specified and diretced
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
M & L for concealed Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including PVC non-metallic double locked casing ISI marked with accessories fixed in wall/ceiling/truss including cutting chases, pinning in etc with PVC non metallic ISI marked terminal boxes concealed wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specifed and directed.
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch.
(c) One exhaust fan point controlled with one 5A switch.
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
Material and Labour concealed point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic double locked casing and caping including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly complete all as specifed and directed.
S&F Modular Switch , 6Amp, One way, 1 module, ISI marked complete all as specified and directed.
S&F Modular Switch , 16Amp, One way, 1 module, ISI marked complete all as specified and directed.
S&F Modular Socket , 6 Amps, 2/3 pin combined 2 module, ISI marked complete all as specified and directed.
S&F Modular Socket , 16Amps, 6 pin combined 2 module, ISI marked complete all as specified and directed.
S&F ceiling rose surface bakelite with ISI mark, three terminals complete all as specified and directed.
S&F Modular white cover plate with Frame 3 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with Frame 4 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with Frame 6 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with Frame 8 Module, ISI marked complete all as specified and directed.
S&F Modular white cover plate with Frame 12 Module, ISI marked complete all as specified and directed.
S&F Modular metal flush box 3 module, ISI marked and including cutting hole in wall / ceiling/piller etc and making good surface complete all as specified and directed.
S&F Modular metal flush box 4 module, ISI marked and including cutting hole in wall / ceiling/piller etc and making good surface complete all as specified and directed.
S&F Modular metal flush box 6 module, ISI marked and including cutting hole in wall / ceiling/piller etc and making good surface complete all as specified and directed.
S&F Modular metal flush box 8 module , ISI marked and including cutting hole in wall / ceiling/piller etc and making good surface complete all as specified and directed.
S&F Modular metal flush box 12 module, ISI marked and including cutting hole in wall / ceiling/piller etc and making good surface complete all as specified and directed.
Supply and fixing integrated LED batten 20 Watt (min 120 lumen per watt) 4 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed.
Supply and fixing integrated LED batten 10 Watt (min 120 lumen per watt) , 2 feet long, full white in Engineering plastic battern with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and directed.
S&F of New LED Bldg security light 45 Watt (min 110 lumen per watt) powder coated pressure die cast aluminium high power LED bldg security light with heat resistant toughned glass with lens with IP66 Protection including 40 mm dia pipe bracket fixing on wall at any height with 02 nos of MS clamp of suitable size,complete all as specified and directed.
S&F Ceiling light 36 W (min 110 lumen per watt) 2X2 ft recess mounted led ultra slumceiling light with extrruded aluminum housing and milky diffuser LED ultra slim panel complete all as specified and directed.
S&F MCB DB TPN 12 way suitable for three phase single, 415 volt sheet steel powder painted enclosure double door type with minimum IP-43 degree of protection with built in 200 Amps copper bus bar, neutral link and earth link complete including flush off in wall with cutting and making good the disturbed surface including connection of circuits with copper pin terminals complete all as specified and directed.
S&F MCB DB SPN 12 way suitable for single phase AC supply, 230 V sheet steel powder painted enclosure double door type with minimum IP-43 degree of protection with built in 200 Amps copper bus bar, neutral link and earth link complete including flush off in wall with cutting and making good the disturbed surface including connection of circuits with copper pin terminals complete all as specified and directed.
S&F MCB DB SPN 8 way suitable for single phase AC supply, 230 V sheet steel powder painted enclosure double door type with minimum IP-43 degree of protection with built in 200 Amps copper bus bar, neutral link and earth link complete including flush off in wall with cutting and making good the disturbed surface including connection of circuits with copper pin terminals complete all as specified and directed.
S & F MCB TPN 40 to 100 Amps, 415 volt, 10 KA rating complete all as specified and directed.
S & F MCB SPN 63 Amps, 240 Volts, C Series complete all as specified and directed.
S & F MCB SP 6-32 Amps, 240 Volts, C Series complete all as specified and directed.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed.
Supply and fix submain wiring 4 run x 10 sqmm + 1 run x 10 sqmm earth wire FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC casing caping/ PVC conduit of suitable dia, ISI marked including 1 single core cable with stranded copper conductor of size 10 sqmm (green colour) for earthing. Note :- (i) Four runs of 10 Sqmm cable, 1 run of PVC casing & caping/ PVC conduit and 1 run of 10 Sqmm cable for earth shall be measured as 1 RM.
Supply and fixing submain wiring with proper colour coding, 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC Conduit/PVC casing caping of suitable size not less than 25 mm , ISI marked including 1 single core cable with stranded copper conductor of size 4 Sqmm (green colour) for earthing. Note : (i) 2 runs of 4 Sqmm cable, 1 run of PVC Conduit/PVC casing caping and 1 run of 4 Sqmm cable shall be measured as 1 Run. (ii) Each Submain Wiring shall run in Seperate PVC Conduit/PVC casing caping.
Supply and fixing submain wiring with proper colour coding, 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 6 Sqmm in and including PVC conduit/ PVC casing caping of suitable size not less than 25 mm , ISI marked fixed on wall/ceiling/ shaft of building with clamps at suitable intervals including 1 single core cable with stranded copper conductor of size 6 Sqmm (green colour) for earthing. Note : (i) 2 runs of 6 Sqmm cable, 1 run of PVC conduit/PVC Casing Caping and 1 run of 6 Sqmm cable shall be measured as 1 Run. (ii) Submain Wiring for Each Qtr shall run in Seperate PVC Conduit/PVC casing caping.
Supply and fixing submain wiring with proper colour coding, 2 single core FRLS 1100 volts grade cable with stranded copper conductor of size 10 Sqmm in and including PVC Conduit/PVC casing caping of suitable size not less than 25 mm , ISI marked fixed on wall/ceiling/ shaft of building with clamps at suitable intervals including 1 single core cable with stranded copper conductor of size 10 Sqmm (green colour) for earthing. Note : (i) 2 runs of 10 Sqmm cable, 1 run of PVC Conduit/PVC casing caping and 1 run of 10 Sqmm cable shall be measured as 1 Run. (ii) Submain Wiring for Each Qtr shall run in Seperate PVC Conduit/PVC casing caping.
S&F in replacement Plug and Socket enclosure, in sheet metal enclosure with MCB, SP 20 Amps 240 Volts complete with metal clad socket including flush off in wall with cutting and making good the disturbed surface for window type air conditioners/geyser complete all as specified and directed.
Supply and fixing , testing and commissioning of storage type water heater (geyser) vertical type of 03 Ltrs capacity , single phase, vertical type, Rust Resistant, ABS made with thermal cut off with power consumption 1500 watts, ISI marked, BEE 5 star rating (latest lable period) including fixing on wall with chroumium plated screws & nut bolts connected to existing water and electric connection complete all as specifed and directed.
Taking down Ceiling / Exhaust fan of any size, sealing cable end, dismantling blades carefully and removing fan and blades to MES E/M Store for safe custody all as directed.
M&L for Making round/ squar hole cutting in wall with the help of cutting machine / chisel / hammer etc for fixing of exhaust fan of size 300 mm to 600 mm & making good to the distrubed surface including plaster, distumper , white wash complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods with sefty GI wire connecting up to fan hook, electronic regulator and accessories , Type of motor - BLDC Motor, 100% super enamelled copper wire winding, 'B' class insullation, 5 star rated approved by BEE (latest lable period) & ISI marked, 230 Volt, single phase AC supply, 50 Hz frequency , rated power - 26/28 W , rated speed - 350 RPM + 10% , Power factor - 0.90 min at 5th speed,, Air delivery - more than 220 CMM, Service value - 8.5 cum/min/W, Temp rise - 75 degree maximum, Double ball bearing, Aluminum blade 03 Nos, Low voltage starting - 185 V (Min) , Insulation resistance more than 2 mega ohm, leakage current - 210 micro Amp Max, THD - less than 8% at 5th speed. and connectding jup including provision of flexible 3 core copper cable .
Supply and fixing exhaust fan , steel body AC single phase, 230 volt of size 225 mm sweep with blades, and frame and louvers.
Supply and fix air circulating fan wall mounted type, Type of motor - BLDC type, super enemalled copper widing, class 'B' insulation, 5 star rated approved by BEE (latest lable period), 230 Volt, 50 Hzs , rated power 30 Watt, rated speed 1350 RPM, power factor 0.90 minimum, air delivery more than 65 CMM, temp rise 75 degree maximum, speed control through remote control/ buttons, low voltage starting - 140 Volts, insulation resistance more than 2 mega ohm, leakage current - 210 micro amp maximum, High volt test - 1500 Volt, THD - less than 10% at 3rd speed complete all as specified and directed .
Taking dwon and Material & Labour for Earthing with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, burried directely in ground (earth pit not less than 2.5 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32 x 6 mm with the help of bolts, nuts, check nuts and washers of galvanised iron or steel, protection GI pipe of 40 mm dia including necessary excavation, PCC 1:3:6 type D2 and PCC cover 1:2:4 type B1 watering arrangement with GI pipe funnel, jali, and cast iron cover fixed on top of pit complete all as specified and shown in electrical plate No.3 including connection to the earthing test point and testing on completion.
Supply and laying, commisssion XLPE insulated armoured LT cable, 110 Volts grade with aluminium conductor of size 3.5 core 50 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed.
Supply and laying, commisssion XLPE insulated armoured LT cable, 110 Volts grade with aluminium conductor of size 4 core 16 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed.
Supply installation commissioning of water cooler fully stainless steel electric driven single phase having approx storae 80 ltrs and nominal cooling cap 40 ltr per hours, using non CFC refrigerant suitable for single phase 230 volts complete all as specified and as directed.
S&F CP gate valve of 15 mm bore suitable for fixing on existing fittings complete all as specified and directed by engineer in charge.
Supply and fix hot water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.
Supply and fix Cold water extension pipe made out of copper chromium plated 450 mm long with brass adaptor and fixing in position complete all as specified.
Supply and fixing 15 mm Bib taps, cast copper alloy with crutch or round handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specifed and directed.
S&F in replacement hote water PVC pipe 15 mm bore with all fittings as required at site i.e. elbow,socket,nipple reducer & union as required for plumbing work and making connection as required at site all as specified and as directed.
Taking down old earthing strip ( lightning porotection strip ) from each wing of the each building and taking out from the wall /roof /piller / earthing pit etc . Supply and fixing GI strip 32 x 6 for building as Lightening Conductor Horizontal, Vertical Down Conductor,complete all as specified and directed.
Taking down old earthing strip ( lightning porotection strip ) from each wing of the each building and taking out from the wall /roof /piller / earthing pit etc . Supply and fixing GI strip 25X3 for building as Lightening Conductor Horizontal, Vertical Down Conductor, Ring complete all as specified and directed.
M&L in Replacement Air termination, single pointed aluminium rod 12mm dia and 300mm long including taking down complete all as specified and directed.
Supply, installation, commissioning, Hi wall split inverter air conditioner electric driven single phase comprising indoor and out door units of capacity 2 TR complete with cordless remote control unit minimum 4 star rating (latest lable period) and EER- 3.2 & above. Compressor type, rotary, refrigerant including copper pipes with insulation, copper armoured cables for connection of indoor and out door unit upto 6 mtrs length and PVC drain pipe of size 15mm upto 6 mtrs complete all as specified and as directed. Note :- Copper pipe with insulation upto 6 mtr including cable for connections and drain pipe upto 10 mtr are inclusive of rate quoted.
Supply and fixing of in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking down complete all as specified and directed.
Supply and fix rotational moulded PVC tank 3000 ltr in position at any location on top of the building including all incoming and out going connections, provision of new fittings suitable up to 80mm bore GI pipe all as per existing requirements complete all as specified and directed.
S&F 50mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches/wall/ceiling/ floor/ all as specified and directed .
S&F 80mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches/wall/ceiling/ floor/ all as specified and directed .
S&F 20mm bore medium grade steel tubes galvanized with all fitting including cutting threading connection in new or old position for laid in trenches/wall/ceiling/ floor/ all as specified and directed .
Note : (i) The rates should be quoted considering the high rise nature of the building (G+5) and necessary scaffolding and safety precautions be inlcuded in the rates. (ii) Enitre building to be covered with Green cloth on MS Scaffolding upto top floor and necessary precautionery sign board to be placed around the building before commencement and completion of work. (iii) Site shall be handed over in Parts as given in Sch A notes.
M/s. MAYUR ENTERPRISES (BID ID -3161379)
SN CONSTRUCTION (BID ID -3161066)
Star Construction Co. (BID ID -3161485)
SHREE JAGDISH FURNITURE CO. (BID ID -3160447)
Shetty Construction Co (BID ID -3161163)
ASHOK ENTERPRISES (BID ID -3159787)
MUKESH CONSTRUCTION CO (BID ID -3161280)
AGRAWAL ASSOCIATES (BID ID -3160778)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .