Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹72.8 L+₹14.6 L (25.1%)Rejected-Finance ENKAY TOWN PLAZA B I BLOCK PALAM VIHAR GURUGRAM HR 122017 | GURUGRAM | GURUGRAM | HARYANA | 122017 | L2 | Rejected-Finance Rejected due to higher rate than L1 | |
| 3 | L3₹74.0 L+₹15.8 L (27.1%)Rejected-Finance | L3 | Rejected-Finance Rejected due to higher rate than L1 | |
| 4 | L4₹74.0 L+₹15.8 L (27.1%)Rejected-Finance MATERE HOUSE SEC NO 14 PRADHIKARAN PUNE MAHARASHTRA INDIA 412105 | PUNE | MAHARASHTRA | 412105 | L4 | Rejected-Finance Rejected due to higher rate than L1 | |
| 5 | L5₹81.5 L+₹23.3 L (40.0%)Rejected-Finance | L5 | Rejected-Finance Rejected due to higher rate than L1 |
Tender Value
Refer Docs
EMD Value
₹1.6 L
Closing Date
19 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL N K SAH
CWE (AF) LOHEGAON, PUNE-411032
INSTALLATION OF 88 AFLS AT AF STN PUNE UNDER GE (P) (AF) LOHEGAON
2021_MES_422984_1
81818/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) (AF) LOHEGAON
Please refer tender documents
6 documents required · 6 mandatory
₹1,000
GE (P) (AF) LOHEGAON
₹1.6 L
Yes
7 Jun 2021
17 Feb 2021
27 Apr 2021
17 Feb 2021
19 Apr 2021
16 Mar 2021
60 days
Amount
Material and labour for inset light fitting with base of following type including core cutting at new raised surface of runway, in-situ photometric test with certified and calibrated photometric testing machine, total station (TS) survey marking (X,Y,Z coordinates) and submission of completion drawing to it's existing position, compaction and ramming the surface and making good the existing surface with adequate materials to match the existing surface, coring by core cutting eqpt on rigid/flexible pavement upto cutting circular hole of dia 326 mm and depth of 150 mm or as required, fixing of fitting in PQC rigid/flexible pavement of runway or as per requirement and precise alignment complete all as specified and directed by Enginner-in-Charge for the following :- (a) Taxiway Edge inset light Omnidirectional high intensity light 45W, 6.6A Ø pre-focused halogen lamp with typical rated life, projection 12.7mm with external, dimensions approx. 220mm. Note:- 1. AFLS light fittings will be Issued by the GE Free for fixing. 2. Any repair of damaged light fitting during installation shall be borne by the contractor and the cost of repair shall be deemed to be included in the quoted rate of the item.
Ditto all as per item No -1 above but Approach inset light of capacity (all type) 3x105W, 6.6A Ø pre-focused halogen lamp with typical rated life, projection 12.7mm with external diameter of 304mm.
Ditto all as per item No -1 above but Runway edge inset C/C and C/Y light- bidirectional high intensity light 2 x105 W, 6.6 A pre focused halogen lamp with typical rated life, projection 12.7 mm with external diameter of 304mm.
Ditto all as per item No -1 above but Runway Over run inset light Black/Red unidirectional high intensity light 3x105W, 6.6A Ø pre-focused halogen lamp with typical rated life, projection 12.7mm with external diameter of 304mm complete all as specified and as directed by Engg-in-charge.
Supply, laying and testing of AFLS primary cable of 1 core X 6 Sqmm, single conductor XLPE Insulated non shielded 5 KV rated voltage and minimum conductor temperatur of90 ̊C for continuous normal operation and 250 ̊C for short ciruit suitable for use in wet and dry conditions and cables to be laid in soil (trench) /runway existing link and crossing complete all as specified and as directed by Enginner-in-Charge. Note - HDPE pipe Horizontal Boring holes, excavation and earth work, sand cushioning and PCC cable covers etc, shall be measured and paid separately)
Material and labour for connection of secondary cable with existing primary cable with proper jointing kit complete all as specified and as directed by Engg-in-charge. Note - Jointing kit will be issued by GE free for fixing
Supply, laying and testing of AFLS Secondary cable 2 core X 4 Sqmm,1 KV flexible bare copper cross linked polyethylene outer dia 4.5mm including laying through HDPE pipe 50 mm dia conduit and cables to be laid in soil (trench) / runway complete all as specified and directed by Enginner-in-Charge. Note : HDPE pipe Horizontal Boring holes, excavation and earth work, sand cushioning and PCC cable covers etc, shall be measured and paid separately.
Excavating in trenches n. exc 1.5m wide and n. exc 1.5m in depth and getting out in soft/loose soil for laying of cables/pipes complete all as specified and as directed by Enginner-in-Charge.
Ditto all as per item No -8 above but getting out in hard / dense soil.
Returning, filling in including spreading levelling, watering, and well ramming in layers not exc. 25 cm in soil complete all as specified and directed by Enginner-in-Charge
Removing excavated materials (soil) not exc 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed by Enginner-in-Charge
M&L for supply, lay/spread in trenches, clean sand, including spreading ,levelling, punning for laying/ cushioning of cable and well ramming in layers not exc 25 cm complete all as specified and as directed by Enginner-in-Charge. Note - Punned thickness only will be measured.
Supply and laying un-reinforced precast concrete cable cover,class HV, Type 1, flat, size 300mm x 180mm x 40 mm as directed at site complete all as specifified and directed by Enginner-in-Charge.
Material and labour for chemical earthing with copper earth plate 900mmX600mmX 5mm thick electrode and 32 X6 mm copper strip as earthing lead copper buried vertically in ground and copper earth plate shall be filled with MFC for improvement of conductivity of electrode,120 KGS approx of BFC shall be filled around the copper strip (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including copper Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel (and 50mm dia GI light grade pipe for protection strip) to the extent of 7.5 metres as earthing lead and connecting to the eqpt, AFLS fittings,CastIron (CI) box etc all as per electrical plate No. 3 of SSR Part I including PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement. Vendors are bound to get earthing result less then 1 Ohm and same must be treated with chemcal (BFC) if required to achieve resistance value,continutiy of good earth resistance shall maintaned upto 1 year. M& L complete including excavation and earthwork in any type of soil strata and testing and painting of earth chamber as per colour code of AF auth. complete all as specified and directed by Engineer -in -Charge. Note - Note -(a) On testing, If the earth resistance less than specified is not obtained, Earthing will be re-done at no extra cost. (b) If Soil Resistance test is required same shall be done by the contractor without any extra cost.
M&L for earth continuity conductor or main earthing lead fixed to wall on baton or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32 X6 mm copper strip complete all as specified and directed by Engineer -in -Charge.
M&L for Earth continuity conductor or main earthing lead buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engineer -in -Charge.
Supplying and laying 50 mm dia HDPE Pipe of pressure rating 10 PN grade PE-100 for the cable protection. The measurement of pipes shall be net as fixed between the fittings including short lenghts,without any allowance for cutting and waste,and in case of spigot and socketed pipes for the portions entering the sockets of the pipes and fittings. the rates for laying HDPE pipes and fittings to be include for jointing and jointing materials in runway area by protection of secondary cable with cutting the existing concrete pavement by cutting square grooves to inset HDPE pipe 50mm bore by diamond cutters and chiseling, removing loose concrete and cleaning with compressed air & washing with chemical water solution, priming epoxy resin primer at the rate of 0.34kg/sqm applied by sprayer or brush and making good with epoxy mortar, including disposal of rubbish materials to a distance exceeding 250m but not exceeding 500m for laying HDPE pipe 50mm bore complete all as specified and directed by Engineer-in-Charge. Note- The washing agent shall be of 15% diluted hydrochloride solution, epoxy resin primer of NITOPRIME 25 brand of M/s FOSROC Industries and epoxy mortar shall be of NITOMORTAR brand of M/s FOSROC Industries or equivalent of makes as listed herewith.
Material and labour for cutting DBM layer, Flexible and PQC and in other rigid surface channels, grooves or rebates n exc 18cm girth, and trimming surface for laying HDPE pipe for protection of secondary cable complete all as directed and specified by Engineer-in-Charge.
Material and labour for Horizontal Boring holes 1 to 2 m deep in soil for under road/pavement/runway/taxi surfaces by trenchless technology using ultrasound technique and necessary machines and getting out and disposal of spoil to a distance of n.exceeding 50m all dia of pipes 200mm all as specified and directed by Engr-in -charge. Note- Any damage of existing system will be deemed by the contractor, the cost of repair of (AF NET cable, LT cable, HT Cable, OFC cable and any pipe line etc) to be included in the quoted rate of item.
Supply and laying 150 mm dia HDPE Pipe of pressure rating 10 PN grade PE-100 for the cable protection, the measurement of pipes shall be net as fixed between the fittings including short lengths,without any allowance for cutting and waste,and in case of spigot and socketed pipes for the portions entering the sockets of the pipes and fittings. the rates for laying HDPE pipes and fittings to be included for jointing and jointing materials in runway area by protection of secoundary cable with cutting the existing concerte pavement by cutting square grooves to inset HDPE pipe 150 mm Bore by diamond cutter and chiselling,removing losses concrete, cleaning and compressed air and washing with chemical water solution, Priming epoxy resin primer at the rate of 0.34 Kg/sqm applied by sprayer or brush and making good with epoxy mortar, including disposal of rubbish to a distance exceeding 250 m but not exceeding 500 m for laying HDPE pipe 150 mm bore complete all as specified and directed by Engineer-in-Charge. Note- (a) The Washing agent shall of 15% diluted hydrochloride solution, epoxy resin primer of NITOPRIME 25 brand of M/s FOSROC Industries and epoxy mortar shall be of NITOMORTAR brand of M/s FOSROC Industries or equivalent of makes as listed herewith.
Installation of CI Transformer housing box including excavation, CC wall 150 mm and making electrical and earthing connection complete with testing all as specified and directed by Engineer-in-Charge. Note:- CI box will be Issued by the GE, free for fixing
Material and labour installation of Isolating Transformer in the CI box including termination of earth wire and complete all as specified and directed by Engineer-in-Charge. Note:- Isolating Transformer will be Issued by the GE, free for fixing.
NSC Projects Pvt. Ltd.
Apurva constructions
V M MATERE INFRASTRUCTURES INDIA PVT LTD
Shri Sai Associates, Laxmiwadi
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .