Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC 1001 B BHAVESHWAR BLDG NO 03 BHAVESHWAR LANE GHATKOPAR EAST MUMBAI 400077 | MUMBAI SUBURBAN | MAHARASHTRA | 400077 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹16.6 L+₹1.8 L (12.0%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L2 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
6 Nov 2021, 6:00 pmClosed
GARRISON ENGINEER NORTH MUMBAI
GARRISON ENGINEER NORTH MUMBAI - 400029
8936 REPAIR / REPLACEMENT OF STREET LIGHT AT KMC, SERVICING AND REPLACING OF SPARE PARTS OF DG SETS AT VARIOUS LOCATION AND SPARE PARTS OF CEILING, WALL MOUNTED, EXHAUST FAN AND GYSER AT DGQA VIKHROLI AND GHATKOPAR UNDER GE NORTH MUMBAI
2021_MES_475226_2
8936/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GARRISON ENGINEER NORTH MUMBAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER NORTH
₹34,000
Yes
30 Nov 2021
16 Oct 2021
8 Nov 2021
16 Oct 2021
6 Nov 2021
23 Oct 2021
17 Oct 2021 - 22 Oct 2021
Amount
Excavation in trenches, not exceeding 1.50 m wide and not exceeding 1.5 m in depth, for foundation, cable trenches etc, not exceeding 10 sqm on plan and getting out hard/dense soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25cm in soil complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge
Supplying and spreading in trenches dry clean crushed stone for cable cushioning and gently punning down in layers complete all as specified and as directed by Engineer-in-Charge Note : Thickness of sand cushioning shall be measured after punning and consolidating of dry clean crushed stone.
Supplying and laying unreinforced precast concrete cable covers, class LV type, flat of size 250mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge. Make : Mehtab Tiles, Indore/M/S Ultra Tiles/NITCO/Topaz Tiles/Navya Tiles, Jodhpur
Supply, lay, test and commissioning of LTUG, XLPE insulated, heavy duty, 1100V grade electric cable with aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-Charge of following sizes:- Make: PARAGON/FINOLEX/PLAZA/POLYCAB/KALINGA/HAVALLS Note : Earthwork excavation sand cushioning cable cover GI protection pipe shall be measured and paid separately in their respective items
16 Sqmm x 4 core
10 Sqmm x 4 core
Supply and fix in replacement of street light bracket arm fabricated out of 40mm dia galvanised iron tube medium grade 1.20m long, bend to shape fixed on pole with including 2 pair of clamps of suitable size, nuts, bolts and washers and applying two coats of aluminium paint over a coat of primer etc complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs cable junction box IP66 protected outdoor installation of size 200 x 160 x 98mm with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32- 2 Nos) fixed on poles with flat iron clamps of size 25x3mm, nut, bolt, washers etc including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and provision of one single pole MCB 6 Amps for controlling light etc complete all as specified and as directed by Engineer-in-Charge. Make : Sintex GS-JB-2014 or equivalent in National
Supply and fix in repairs 2 single core wiring for street light fitting complete of 2.5 sqmm single core PVC insulated and unsheathed copper conductor cable 1100 volts grade drawn through and including non mettalic PVC conduit of size 20mm including accessories and fixed on walls and connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge. Note :-Two runs of 2.5 sqmm cable, one run of PVC conduit will be measured and paid as one unit length. Make: Finolex / Plaza / Anchor / Havells / Polycab
Supply and fix galvanised iron pipe, light grade, 40mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary including taking down existing etc complete all as specified and as directed by Engineer-in-Charge. Make: TATA/SWASTIK/JINDAL/Bharat Steel tube/ZENITH/Indian Tube Company
Supply and fix in repairs digital timer programmable switch, single phase rating with contactor type ML-2 , 240 volts fixed inside steel enclosure complete all as specified and as directed by Engineer-in-charge. Make: L&T / Havells / Schneider / ABB / Legrand / Siemens
Supply, install, test and commission LED street light fitting 45 watts, 240 volts, AC, outdoor type with high pressure die cast aluminium housing and heat resistance toughened glass with frame with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with necessary copper wire connection of suitable size including taking down of old unsv light fitting with bracket complete all as specified and as directed by Engineer-in-Charge. Make - Havells Cat Part No ENDURAPEARLNEOSL45WLED757 PASYTOPC or Equivalent in CG / Philips / Sakti / Halonix / Benlo
Supply, install, test and commission LED street light fitting 60 watts, 240 volts, AC, outdoor type with high pressure die cast aluminium housing and heat resistance toughened glass with frame with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with necessary copper wire connection of suitable size including taking down of old unsv light fitting with bracket complete all as specified and as directed by Engineer-in-Charge. Make - Havells Cat Part No ENDURAPEARLNEOSL60WLED757 PASYTOPC or Equivalent in CG / Philips / Sakti / Halonix / Benlo
Material and labour for complete removal of existing paint of steel tubular / rail poles of length 9.0 metre long including preparation of outer surfaces and applying two coats of aluminium paint over a coat of red oxide zinc chrome paint and two strip of yellow and black colour paint of size 30cm width from bottom of pole height including numbering to pole with base of yellow colour and black base foe numbering not less than 100mm in height and 10mm in width etc complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCCB 3 pole, 125 Amps, 415 Volts, 25 Hz, 35 KA breaking capacity, thermal & magnetic adjustable type with extended copper terminals including all connections and testing including taking down of old unserviceable MCCB complete all as specified and as directed by Engineer-in-charge. Make: Schneider / Havells / L&T / ABB / Legrand / Siemens / Benlo
Supply and fix MCCB 3 pole, 100 Amps, 415 Volts, 50 Hz, 35 KA breaking capacity, thermal & magnetic adjustable type with extended copper terminals including all connections and testing including taking down of old unserviceable MCCB complete all as specified and as directed by Engineer-in-charge. Make: Schneider / Havells / L&T / ABB / Legrand / Siemens / Benlo
Supply and fix MCCB 3 pole, 63 Amps, 415 Volts, 50 Hz, 35 KA breaking capacity, thermal & magnetic adjustable type with extended copper terminals including all connections and testing including taking down of old unserviceable MCCB complete all as specified and as directed by Engineer-in-charge. Make: Schneider / Havells / L&T / ABB / Legrand / Siemens / Benlo
Supply and fix aluminium bus bar chamber 63 Amps, three phase, 4 pole 415 volts with all fixing accessories etc complete all as specified and as directed by Engineer-in-Charge. Make : C&S / Havells / L&T / Legrand
Supply and fix aluminium bus bar chamber 32 Amps, three phase, 4 pole 415 volts with all fixing accessories etc complete all as specified and as directed by Engineer-in-Charge. Make : C&S / Havells / L&T / Legrand
Supply and fix aluminium bus bar chamber 100 Amps, three phase, 4 pole 415 volts with all fixing accessories etc complete all as specified and as directed by Engineer-in-Charge. Make : C&S / Havells / L&T / Legrand
Material and labour for Plain Cement Concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping of poles including necessary formwork etc complete all as specified and as directed by the Engineer-in-charge
Material and labour for Plain Cement Concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation / mass concrete including necessary formwork etc complete all as specified and as directed by the Engineer-in-charge
Supply and erect 9.0 metre long steel tubular swaged poles type 410 SP-31 complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specified and as directed by Engineer-in-Charge. Note: Earth work excavation, PCC for foundation and coping will be measured and paid separately.
Supply, install, test and commissioning suitable size factory made out door type 1.2m x 0.85m x 0.45m dust and vermin proof, LT feeder pillar box, double door, cubical and compartmentalized type, 415 volts, AC, 50 Hz, fabricated with non corrosive 3 mm thick CRCA sheet for outer side and 2 mm thick inside complete with and including mounted on angle iron frame stand of size 40 x 40 x 5 mm thick, 50 cm long leg, grouted in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), spray painted inside and outside, powder coated of approved colour by Engineer-in-Charge, including openable shutters butt hinged, locking arrangement, PCC work, excavation & earth work complete including comprising for following and taking down existing etc complete all as specified and as directed by Engineer-in-Charge:-
Material and labour for Earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to and including galvanised earth lead wire 4 mm dia, 7.5m long, by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel with provision of charcoal & common salt packed upto minimum 150 mm all around the earth plate, and protected by 15 mm bore light grade galvanised iron pipe and connected to control board / panel / equipment complete all as shown in electrical plate No.3 of MES schedule Part I with PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, MS angle iron frame of size 50mm x 50mm x 5mm, cast iron cover with locking arrangements, GI 20 mm bore medium grade pipe and CI funnel with wire mesh for watering arrangement including necessary excavaion and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan / exhaust fan / wall mounted fan of any make/type/size/sweep, at site from any height of the building for any defect, servicing complete, repairs / overhauling including replacement of worn out parts / rewinding as required, spare parts & re-fixing in same position including successful testing on full load with blade complete all as specified and as directed by Engineer-in-Charge. Note: (i) Capacitor, ball bearing, condenser, bushes, split pin, 'U' clamp with rubber reel, shaft and PVC canopy will be measured and paid separately as "Supply only". (ii) Serviceable spares shall be reused. (iii) Rewinding will be measured and paid separately.
Material and labour for rewinding of burnt copper coil for ceiling fan 1200 mm sweep, 230 volts, AC, (after opening and taking out burnt winding) with suitable size of super enamelled copper winding wire so as to meet original specification of fan including insulation material/varnishing etc., and reassembling the same after testing on full load with blade complete all as specified and as directed. Make: Deen dayal, finolex, Atlas.
All as per item No. 29 described here-in-before but ceiling fan 1400mm sweep, 230 volt, AC
Material and labour for rewinding of burnt copper coil for exhaust fan 300 mm sweep, 230 volts, AC, (after opening and taking out burnt winding) with suitable size of super enamelled copper winding wire so as to meet original specification of fan including insulation material/varnishing etc., and reassembling the same after testing on full load with blade complete all as specified and directed. Make: Deen dayal, finolex, Atlas.
All as per item No. 31 described here-in-before but exhaust fan 380mm sweep, 230 volt, AC
All as per item No. 31 described here-in-before but exhaust fan 450mm sweep, 230 volt, AC
Material and labour for rewinding of burnt copper coil for wall mounted fan 400/450mm sweep, 230 volts, AC, single phase, removing old unserviceable wire, cleaning of slots properly and rewinding with super enamelled copper winding wire of existing gauge with insulating material, heating, varnishing, greasing, re-assembling the same after testing on full load with blade and replacement of worn out minor parts complete all as specified and as directed by Engineer-in-Charge. Make: Deen dayal, finolex, Atlas.
Material and labour for machining the shaft of ceiling fan to suitable size of gun metal bushes complete all as specified and directed by Engineer-in- Charge.
Supply only ball bearing suitable for ceiling fan as per sample ( 6201/6202) complete all as specified and as directed by Engineer-in-Charge. Make: SEICO, NBC, SKF, TATA
Supply only ball bearing suitable for exhaust fan as per sample ( 6203/6204) complete all as specified and as directed by Engineer-in-Charge. Make: SEICO, NBC, SKF, TATA
Supply only ball bearing suitable for wall mounted/cabin fan as per sample complete all as specified and as directed by Engineer-in-Charge. Make: SEICO, NBC, SKF, TATA
Supply only Gun metal bushes for fans of different sizes complete all as specified and as directed by Engineer-in-Charge.
Supply only condenser 2.5 MFD, 230V, AC complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Fentex, Tesla, Epcos
Supply only condenser 1.5 MFD, 230V, AC complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Fentex, Tesla, Epcos
Supply only heavy duty shackle type rubber reel complete all as specified and as directed by Engineer-in-Charge.
Supply only flexible wire 23/0.0076 size, three core, 1100 Volt, twisted, PVC insulated, copper conductor, multistranded for connection complete all as specified and as directed by Engineer-in-Charge. Make: Havells, Plaze, Finolex
Supply only MS nut, bolt 8mm dia of suitable size for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge.
Supply only MS clamp for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge.
Supply only down rod, MS, 15mm dia, heavy duty, 300mm long for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge.
Supply only down rod, MS, 15mm dia, heavy duty, 450mm long for hanging of the ceiling fans complete all as specified and as directed by Engineer-in-Charge.
Supply only PVC canopy for 1200/1400mm sweep as per existing size and make complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs ceiling fan regulator AC, 230 volts, 100 watts, electronic type, mini (step type) complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Anchor( Penta), Cona
Supply and fix in repairs ceiling fan regulator AC, 230 volts , 100 watts, electronic type, deluxe (step type) complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Anchor( Penta), Cona
Supply and fix in repairs new metal blades suitable for ceiling fan of 1200mm sweep complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Supply and fix in repairs new metal blades suitable for ceiling fan of 1400mm sweep complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Supply and fix in repairs new metal blades suitable for pedestal/air circulator fans of 400mm sweep complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Supply and fix in repairs new metal blades suitable for exhaust fans of size 600mm complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Supply and fix in repairs new metal blades suitable for exhaust fans of size 300mm complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Supply and fix in repairs new metal blades suitable for exhaust fans of size 450mm complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Supply and fix in repairs new fiber blades suitable for wall mounted fans of 400mm sweep complete all as specified and as directed by Engineer-in-Charge. Make: Usha, Crompton Greaves, Khaitan
Cutting openings, through brick walls built in cement mortar for exhaust fan of any size, cleaning and stacking bricks, removing surplus serviceable bricks, etc.. to store, rubbish outside MD land and making good in cement concrete 1:2:4 type B0 as required, rendering 10mm thick in CM (1:6) to match with the existing surfaces including grouting of bolts for mounting of exhaust fan complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing old surfaces of ceiling fan/exhaust fan of any capacity or sweep, by scrapping and removing dust etc and filling cavities with one coat of filler and applying synthetic enamel paint by spraying and writing MES Nos in block letters as per existing complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs ceiling rose 3 phase, surface bakelite, 65 x 35, two to three terminals, AC, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully storage type electric water heater (Geyser) of any capacity. carrying out servicing including replacement of various size screws and clamps, base assembly, washers, glands of all types/ valves / heating elements / Thermostat pipes / drain plug / thermal cut-out / safety valve and to ensure water tightness and worn out minor parts including re-fixing in the position after testing complete all as specified and as directed by Engineer-in-Charge. Note : Base plate assembly, Heating elements, thermostat pipes, thermal cut out and safety valve will be measured and paid separately as "Supply only."
Supply only base plate assembly of 25/50 ltrs capacity geyser complete with inlet, outlet and thermostat pipes complete all as specified and as directed by Engineer-in-Charge.
Supply only heating elements of capacity 1.5/2 KW, AC, 230 Volt complete all as specified and as directed by Engineer-in-Charge.
Supply only thermal cut out, suitable for 25/35/50 ltrs capacity geysers complete all as specified and as directed by Engineer-in-Charge.
Supply only 15mm bore safety valve/high pressure release valve, ISI marked complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing old surfaces of Geyser of any capacity, by scrapping and removing dust etc and filling cavities with one coat of filler and applying synthetic enamel paint by spraying and writing MES Nos in block letters as per existing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Geyser inner tank bracing and arresting leakage any type complete all as specified and directed.
Supply and fix in repairs PVC heavy duty connecting pipe of 15 mm dia and 600 mm long with adaptor complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs PVC heavy duty connecting pipe of 15 mm dia and 450 mm long with adaptor complete all as specified and as directed by Engineer-in-Charge.
Supply only indicator neon lamp, any colour complete all as specified and as directed by Engineer-in-Charge.
Labour only for servicing of 100 KVA DG Set with draining out of engine oil/lubricant coolant, taking out of unserviceable Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of Fuel tank etc complete all as directed. Make : Kirloskar. (Loc. : WT Stn Juhu) Note : Spares and lubricant shall be measured and paid separately as supply only under respective items here-in-after.
Supply only Fuel Filter element
Supply only Lub Oil Filter element
Supply only Air Filter Element (Inner & Outer)
Supply only 'V' Belt
Supply only Hose pipe
Laboure only for servicing of DG set 60 KVA capacity, Make - KIrloskar by taking down various unserviceable items such as switches, relays, pads, terminals, hoses, coupling, battery leads with lugs, filters, belts, pipes, coolant etc and replacing them with new items, testing etc complete all as directed by Engineer -in-charge. Note :- Spares shall be measured and paid separately as supply only under respective items here-in-after
Supply only solenoid switch
Supply only stoping relay, 12 volt DC.
Supply only Anti vibrating pad .
Supply only Heavy duty battery terminal for 12 volt DC.
Supply only Ignition switch as per sample.
Supply only Battery lead with lug/ terminal block as per existing length and capacity.
Supply only Air filter as per sample.
Supply only Primary Fuel filter
Supply only Secondary fuel filter
Supply only Lubricating oil filter
Supply only Fuel pipes with benjo bolt and washers
Supply only V- belt as per existing size
Supply only Diesel pipe PVC flexible size up to 12 mm
Supply only Draining out the old unserviceable engine oil from the DG set and refill with new HD 30 oil as recommended by Mfg.
Supply only Feed pump for 60 KVA Acoustic DG set, Make- kirloskar
Material and labour for disconnecting / dismantling of self starter from DG set 60 KVA capacity by removing all electrical connections and carrying out to work shop for replacing the defective parts, main shaft, bentex, pinion bearing, DE/CE bush, field coil assembly etc greasing and refitting and carrying back and connecting, testing complete all as specified and directed by Engineer-in-charge.
Material and labour for replacement to engine and generator / alternator joint MS coupling with flexible rubber coupling/rubber bush/rubber disc by taking out old coupling from the DG Set 60 KVA capacity
Repair and over hauling of dynamo/Alternator of 60 KVA capacity DG Set of any make by replacement of the following parts :- Note :- Spares shall be measured and paid separately as supply only under respective items here-in-after
Supply only Carbon Bush
Supply only Armature rewinding
Supply only Field Coil repair
Cleaning of fuel tank for DG Set of capacity 60 KVA and writing date of cleaning and supply and fixing scale outside the tank for reading fuel with tank.
Taking out FIP from DG set, transportation to authorized service centre for overhauling and re-calibration and re-fixing to DG Set including replacement of necessary spare parts such as delivery valves, plunger, "O" ring spring etc of DG Set 60 KVA capacity
Supply Fixing of Battery terminal bolt type suitable for 12V 180 AH battery all as directed by Engineer-in-Charge.
Supply and fixing battery lead of copper conductor 50 sqmm single core fitted with lead terminal on one side and other side with brass or lead terminal as per requirement and connection as directed by Engineer-in-Charge.
Supply only Battery Charger 24/12V, Max Current 20 Amps, all as directed by Engineer-in-Charge. Make : Model C 20/72, ELAK or Eqlt.
Top overhauling of 60 KVA DG set by removing of engine cylinder head /prime mover including replacement & re fixing of a necessary parts such as head gasket, valve guide, injection sleeve, valve inlet, valve exhaust including testing of DG all as specified and directed by Engineer-in-charge. NOTE:- Cost of oiling, greasing, tightening of nut, bolts & minor extra are included in the unit rate quoted by the contractor.
Taking out injection nozzle from 60 KVA DG set transportation to authorised service center for repairing and replacement of necessary parts calibration and re-fixing to DG set and testing complete all as directed by Engineer-in-Charge.
Material and Labour for replacement of panel board wiring with 4 sqmm multistranded copper wire cable all as specified and directed by Engineer-in-charge.
Material and labour hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface at transformer yard all as specified and directed by Engineer-in-charge. .
Supply and replacement of radiator complete with all accessories suitable for 60 KVA DG Set. Make :Greaves.
Supply and fix Turbo charging unit for 60 KVA DG set complete all as specified and directed by Engineer-in-charge.
Material and labour for supply and fixing on load change over switch in sheet enclosure 200 amp, 4 pole, 50 Hz, AC with side handle operation confirming to IS 4064/IS 13947. Make : Havells/ BENLO/Standard/ C&S / HPL/ABB.
Supply and fix new oil pressure Gauge by replacing of old one for 60 KVA of any make DG sets.
Strip opening of alternator of capacity 60 KVA, removing rotor from the starter and rewinding to CT coils complete with super enamelled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator and refixing with Engine and complete testing & re fixing all the component of the alternator and mounting the same on the existing foundation including aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engineer-in-Charge. Note :- Spares shall be measured and paid separately as supply only under respective items here-in-after
Supply only Rear and front bearing including greasing.
Strip opening of diesel engine and removing all the component of 60 KVA DG set Engine and repair to cylinder head (4 Nos) valve seat exhaust/ inlet (8 Nos) and crank (01 No) by grinding, polishing and replacement of following parts & re fixing all the component of the engine and mounting the same on existing foundation including aligning the engine with alternator and testing on full load as specified in particular specification and as directed by Engineer-in-Charge. Note :- Spares shall be measured and paid separately as supply only under respective items here-in-after
Supply only Cylinder liner
Supply only Joint ring liner
Supply only Oil seal
Supply only Piston Assy
Supply only Piston rings complete
Supply only Thrust washer
Supply only small end bearing
Supply only Camshaft bush bearing
Supply only Connecting rod bush
Supply only Hose set kit complete
Supply only Gasket Set complete
Supply only L.O filter
Supply only Main bearing
Supply only Valve inlet/ exhaust
Supply only Valve guide
Supply only Valve seat
Supply only Gasket cylinder head
Supply only Push rod
Supply only Cam shaft bearing
Labour only for servicing of 15 KVA DG Set with draining out of engine oil/lubricant coolant, taking out of unserviceable Oil Filter element, Fuel filter element, fuel flexible pipe, V belt for water pump and alternator, air filter element, cleaning of Fuel tank etc. Complete all as directed. Make : CG. (Loc. : Kalina) Note : Spares and lubricant shall be measured and paid separately as supply only under respective items here-in-after.
Supply only Air Filter Element,
Supply only L.O. filter cartridge
Supply only Hose Radiator
Supply only 'V' Belt,
Supply only Fuel Filter Element,
Supply and filling of Engine oil 15W40 to top-up/ refilling of all DG set of various capacity, model & location as mentioned here-in-before as per the standard practice Make: SERVO / Castrol / HP / Valvoline.
Supply and filling of Coolant suitable for DG set Make : CASTROL / SERVO / PUROKOOL / K-Kool
Supply and fixing of glass wool insulation (50mm thick), duly wrapped over the exhaust pipe (80 - 100 mm dia) of generating set including cladding over the insulation with aluminium foil tape complete all as directed. Note : Length of exhaust pipe shall be taken into account for measurement.
Material and labour for Painting of DG sets after cleaning the body surface of engine and alternator by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of synthetic enamel paint by spray paint incl rewriting existing SM No/MES No of 15/60/100 KVA capacity all as directed by Engineer-in-Charge
Supply and Fix battery, 12 Volt, 100 AH, of size XP 1800, Make : Exide or Amaron.
Supply and Fix battery, 12 Volt, 150 AH, of size XP 1500, Make : Exide or Amaron.
Material and labour for Earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to GI earth leaed 32 x 6 mm dia and including galvanised earth lead wire 4 mm dia, 7.5m long, by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel with provision of charcoal & common salt packed upto minimum 150 mm all around the earth plate, and protected by 15 mm bore light grade galvanised iron pipe and connected to control board / panel / equipment complete all as shown in electrical plate No.3 of MES schedule Part I with PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, MS angle iron frame of size 50mm x 50mm x 5mm, cast iron cover with locking arrangements, GI 20 mm bore medium grade pipe and CI funnel with wire mesh for watering arrangement including necessary excavaion and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge.
Supply and laying for cable in floor/walls or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core all as specified and as directed
All as per Item No. 99 described here-in-before but of size 70 Sqmm 3.5 Core.
All as per Item No. 99 described here-in-before but of size 95 Sqmm 3.5 Core.
Material and labour for repairing of AMF panel suitable for 100 KVA DG set, including replacement of main contactor 200 Amps - 01 No auxiliary contactor LED lights etc including internal wiring and all spares if required etc complete all as directed by Engineer-in-charge
joshua construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .