Loading…
Loading…
Tender Value
₹52.9 L
EMD Value
₹1.1 L
Closing Date
23 Dec 2025, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TELECOM
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited. : Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- 1. Work of Supply, Installation, Testing and Commissioning of PDH/SDH, ADM/PD Mux and its associated equipments. OR 2. AMC of PDH/SDH, ADMs, PD Mux/Faulty Card of Mux Repair work and associated equipment. OR 3. Work of Excavation of Trench and Underground cable laying, Jointing of copper cable or OFC cable. OR 4. Trenching, Laying, Splicing and Testing of OFC Cables and Part Supply, Testing and Commissioning of SDH equipment. OR 5. Trenching, Laying, Jointing and Testing of 6 Quad/PIJF Cables including, Erection & testing of Emergency socket and part Supply, testing and commissioning of Repeater Equipments. OR 6. Trenching, Laying, Splicing/Jointing and Testing of OFC/6 Quad Cables, Erection & testing of Emergency socket and part Supply, Testing and Commissioning of SDH/Repeater E q u i p m e n t . NOTE A1: For the following equipment's a.SDH/STM/PDMUX/IPMPLS/VOIP b. Control equipment c. ISDN/IP based exchange d. CCTV/Video surveillance system e. Integrated security system f. Networking equipment g. Train information display board/Coach guidance system/IPIS/GPS CLOCKS h. secured communication system at level crossing gates i. VSAT J. MTRC 1. The equipment shall be procured from: a) If there is any RDSO approved source, then the equipment to be procured from the RDSO approved source or its authorized dealer/distributor b) If there is no RDSO approved source but there is TEC approved source, then the equipment to be procured from the TEC approved source or its authorized dealer/ distributor c) If there is no RDSO or TEC approved source then the equipment to be procured from the OEM or its authorized dealer/ distributor. 2. Make, Model Specification of the offered equipment along with OEM authorization if the tenderer is other than OEM shall be submitted along with the tender. 3. MOU with RDSO approved Source or TEC approved source or the OEM, covering Supply, installation, testing, commissioning of system including after sales support required during warranty period shall be submitted along with the tender.
21 conditions · 12 needing a document upload
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Associated telecom works for provision of RUB at KM 98/16-99/1 between LMN- DYP, Km 11/2-3 b/w BYHA-URPR, Km 37/8-9 and Provision of RUB for closure of LC- 61/C at KM 861/17-19, LC-77/C at KM 893/24-26 in ZBD-AYC, LC no. 70/C, 75/C, 103/C, 116/C & 119/C in DMW-ON sections of Lucknow Division.
106-Tele_Tender_09_25-26~NR
106-Tele_Tender_09_25-26
Open
Works - General
180 Days
Lucknow, Uttar Pradesh
₹0
₹1.1 L
23 Dec 2025
2 Dec 2025
9 Dec 2025
77 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 52,87,402.28 | ||
| — | 7100.00 | — | — | ||
| Laying of signaling /telecom / power cable of different cores as per Drg No (NR /S&T / Con /1.1/97C) and as per cable route plan approved by Railway through trenches, RCC pipe, DWC pipe, GI pipe etc. Meggering of cable should be done before and after laying. Cable will be made available at the store of concerned SSE/Sig or any other store N. Railway. Contractor has to transport it to work site at his own expenses. | — | — | — | 45,724 | |
| — | 97.00 | — | — | ||
| Supply of VF Transformers (2T/3T),1120/470Ohms as per RDSO Spec. No. IRS: TC-76- 2000 with Amnd. 1 or latest for emergency joints in 6-Quad Cable. INSPECTION: CONSIGNEE | — | — | — | 91,786.25 | |
| — | 36.00 | — | — | ||
| Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision3 with latest Amd. INSPECTION: CONSIGNEE | — | — | — | 88,364.52 | |
| — | 36.00 | — | — | ||
| Jointing of 4 / 6 quad/Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required forthe work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defector any damage is observed during jointing, the contactor has to redo the joint free of cost. | — | — | — | 47,598.84 | |
| — | 13.00 | — | — | ||
| Supply of thermo shrink jointing kit as per IRS TC 77/2012 Rev.3 with Amdt 1 & 2 latest amendments & provision of derivation isolation joint in quad cable & PIJF cable at LC gate, pump, houses, station cabins etc using thermo shrink jointing kit as per specifications, drawings and stipulations of tender documents. This includes all material required for making joints. INSPECTION: CONSIGNEE FOR SUPPLY PORTION | — | — | — | 1,28,207.56 | |
| — | 15.00 | — | — | ||
| Supply of apparatus case steel half with 'E' type locks and key ward No.42 as per drawing No. RDSO/S-11507 or latest. Handle should be atthe rate of one each per 4 Nos apparatus case. INSPECTION:CONSIGNEE | — | — | — | 2,68,882.35 | |
| — | 16.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of app. Case half as per Drg, No (NR/S&T/Con/2.8/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress ofwater in the base of location box. All material such as cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 87,824.64 | |
| — | 7100.00 | — | — | ||
| Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer in charge at site. Inspection: Consignee | — | — | — | 89,247 | |
| — | 7100.00 | — | — | ||
| Supply of 40 mm outer dia. PLB HDPE duct as per RDSO Spec. No. RDSO/SPN/TC/45/2013, Rev 2.0 or latest with all accessories (like couplers, bends etc) The material is to be procured from RDSO approved vendor. INSPECTION: CONSIGNEE | — | — | — | 4,26,497 | |
| — | 7100.00 | — | — | ||
| Laying of PLB HDPE pipe in trench/open space, fixing and clamping of HDPE pipe on wall or structure and sealing of the duct after laying with proper fixing material. All the accessories like couplers, end caps/plugs to be provided by the contractor within the same cost and its protective work as per direction of site engineer. | — | — | — | 71,994 | |
| — | 36.00 | — | — | ||
| Supply of OFC joint enclosure 24 fibers as per RDSO Spec. No. RDSO/SPN/TC/68/2014 Revision 1.0 or latest complete with all accessories (Sealing with mechanical clamp facility INSPECTION: CONSIGNEE | — | — | — | 56,539.8 | |
| — | 742.00 | — | — | ||
| Splicing/Dropping /Termination of each fibre/pigtail in the LIU/I0 Box/Terminal Joints through fusion splicing of termination of OFC cables. The fibres terminated shall be tested and the test report (Hard copy and soft copy) shall be submitted to the site Engineer for records. Each fibre shall be properly marked with necessary ferrules/tags. ( Inspection by Railway Site Engineer | — | — | — | 94,234 | |
| — | 18.00 | — | — | ||
| Supply & installation of jointing pit as per Railway requirement with cover and required trenching to ease out cable/duct(The Joint chamber should be the size of outer dia 1100 mm.Height-600 mm(2 piece of300mm) INSPECTION:CONSIGNEE FOR SUPPLY PORTION | — | — | — | 1,03,546.08 | |
| — | 5680.00 | — | — | ||
| Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No. NR/S&T/Con./1.1/97A or latest so as not to form a drain 0.3 mtrs. Wide & 1 mtr. Deep on both side of the station alongside the track. It shall conform to the safe distance as per signaling and cable plan in all type of soil. It also includes clearance of roots of trees & bushes. (15cm wide 30cm depth) | — | — | — | 3,01,664.8 | |
| — | 45440.00 | — | — | ||
| Supply and laying of 2nd Class bricks in the trench and laying as per DRG no. (NR/S&T/Con./1.1/97A) and as per instruction of the site Engineer INSPECTION: CONSIGNEE FOR SUPPLY PORTION | — | — | — | 3,14,899.2 | |
| — | 1340.00 | — | — | ||
| Horizontal direction drilling (HDD)/Trenchless digging/machine drilling without damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labors for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only aft er DWC/HDPE/GI pipe is laid in the bore." INSPECTION:CONSIGNEE. | — | — | — | 6,57,685.4 | |
| — | 80.00 | — | — | ||
| Horizontal Drilling by using manual pushing method (also called Moling) at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in Charge. Boring diameter should be at least 110mm. HDPE/GI pipe (make: TATA/Jindal or better) as per site requirements | — | — | — | 11,108 | |
| — | 8800.00 | — | — | ||
| Transportation of S&T materials by road as per the instruction of railway representatives at site. The work also include loading and unloading of the materials. | — | — | — | 1,68,872 | |
| — | 420.00 | — | — | ||
| Supply and fixing of G.I. pipe 75mm dia, 3mm thick as per spec no IS-1239, perforated at a distance of 20 CM or less of required length at culverts/ bridges/along the cuttings, suitably concreted at both ends as per approved drg. No.Drg. No.NR/S&T/CON/1-4/97 or at ASM office/other buildings suitably fixing it to the wall and at both ends. G.I. clamps of M.S. flats bolts and nut, to be supplied by the contractor. Inspection by- Consignee for supply portion. this includes transporting GI Pipe from any store of LKO Div, to site INSPECTION: CONSIGNEE FOR SUPPLY PORTION | — | — | — | 4,13,238 | |
| — | 500.00 | — | — | ||
| Supply of 10 PAIR PIJF (POLYTHENE INSULATED JELLY FILLED) 0.5MM DIA CABLE AS PER RDSO SPECN IRS-TC-41/97 WITH AMENDMENT 2 OR LATEST. INSPECTION: CONSIGNEE | — | — | — | 46,210 | |
| — | 500.00 | — | — | ||
| Laying of Quad Cable, PIJF cable of different sizes, power cable of different size in the excavated trench, inside GI, RCC and HDPE pipes. This includes loading/unloading &transportation of cables from the stores of railway as per the availability. Wherever several cables of different categories have to be laid in the same trench/path, the provision of separation of various cable should be as advised by the site incharge of the Railway. Empty cable drums to be returned by the contractor. The cable drums with unused cable at site to be returned by the contractor from site to Stores depot. The work is to executed asper the instruction of Railway Engineer. | — | — | — | 7,325 | |
| — | 10.00 | — | — | ||
| Supply of Thermoshrink jointing kit for 10/20/50pair Jelly filled cable conforming to RDSO Spec. No. RDSO/SPN/TC/57/2006 (Rev.0) (With latest amendment). INSPECTION: CONSIGNEE | — | — | — | 30,421.6 | |
| — | 10.00 | — | — | ||
| Jointing of 4 / 6 quad/Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. Inspection: Consignee | — | — | — | 13,221.9 | |
| — | 5.00 | — | — | ||
| Supply of Emergency socket box made of FRP material as per Spec. No. RDSO/SPN/TC/44/2002 INSPECTION: CONSIGNEE | — | — | — | 21,477.25 | |
| — | 5.00 | — | — | ||
| Supply of 6 pin Emergency socket SPECIFICATION NO: IRS:TC:42/87 with latest amendment INSPECTION: CONSIGNEE | — | — | — | 1,259.6 | |
| — | 5.00 | — | — | ||
| Fixing of Emergency socket box made of FRP material as per Spec. No. RDSO/SPN/TC/44/2002 Ver.2 (With latest amendment) at locations to be indicated by the engineer. Emergency Socket & Emergency socket box will be procured through separate schedule of this contract and issued to the contractor for execution). All other items shall be supplied/arranged by the contractor. | — | — | — | 4,023.35 | |
| — | 20.00 | — | — | ||
| "Supply of DP Box 20Pair with Krone Modules. INSPECTION: CONSIGNEE | — | — | — | 13,909.6 | |
| — | 20.00 | — | — | ||
| Installation of DP Box 20Pair. The work is to executed as per the instruction of Railway Engineer. | — | — | — | 695.8 | |
| — | 3.00 | — | — | ||
| Supply, installation & commissioning of maintenance free earth suitable kit as per RDSO specification RDSO/SPN/197/2008 and Drg No. SDO/RDSO/E&B/002 dated 19.09.2008 or latest with latest amendments. Earthing kit consisting of 1. Earthing electrode of 17 mm dia 3m long - 01 No. 2. MEEB (300mm X 25mm X 6mm) - 01 No. 3. SEEB (200mm X 25mm X 6mm) - 01no. 4. Earth Enhancing compound-30-35 Kg (minimum). 5. Multistrand Single core PVC insulated copper cable 35 sq mm as per IS:694 (Duplicated) used to connect MEEB to main earth electrode Min. 10 mtrs or as per site requirement. This includes:- provision of earth connection from MEEB to S&T equipment i.e. cable sheath, apparatus case, BPAC, Axle counter, IPS, Data logger etc. with PVC earth wire of Size 16/25 Sq mm. through copper lugs of suitable size. PVC earth wire shall be supplied by Contractor. Note: At certain locations, it may not be possible to achieve earth resistance of less than 1.0 ohm with one earth electrode/ pit due to soil resistivity. In such cases, provision of loop earth consisting of more than one earth pit shall be done for interconnection of two earth pits copper tape of size 25 X 2 Sq. mm shall be provided by the contractor. The number of pits required shall be decided based on the resistance achieved for the earth pits already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Supply by RDSO approved Firm. INSPECTION: RDSO | — | — | — | 81,658.29 | |
| — | 9.00 | — | — | ||
| Digital earth tester 4-Terminal, range 0-10/100 Ohm with Ni-cd rechargeable battery with accessories kit and other required accessories TEC spec no GR/TIE-10/01- April 2005 or latest. INSPECTION: CONSIGNEE | — | — | — | 52,222.68 | |
| — | 10.00 | — | — | ||
| Supply of Digital insulation Tester (Megger) 100 V, Motwani, Philips or equal to make. INSPECTION: CONSIGNEE | — | — | — | 77,290.7 | |
| — | 7.00 | — | — | ||
| Supply of Transmission Measuring Set(TMS) as per IRS Spec IRS:TC 43-87 orlatest with OEM Test certificate andaccessories similar to Aplab make Model2031A INSPECTION: CONSIGNEE | — | — | — | 1,33,055.72 | |
| — | 32.00 | — | — | ||
| Supply and installation of 4 wire DTMF based way station equipment complete as per RDSO specification No.IRS.TC 60/2007 and 4 wire control telephone with audio visual indication and reset button fitted on telephone conforming to specification No. IRS-TC 60/2007. This work also includes supply and wiring of power supply arrangements for way station equipment conforming to specification IRS.TC.72/97. [All the materials required for the work shall be supplied by the Contractor](installation of the equipment shall be done as per site requirement). INSPECTION: CONSIGNEE | — | — | — | 3,54,888 | |
| — | 8.00 | — | — | ||
| Supply of Gas Type Blow Lamp for Quad/PIJF Cable jointing with: (a) 2 Kg capacity of Gas Cylinder (b) 0.5 Mtr. Blow lamps Torch Pipe with burner made of Pure brass type with Nickle Chrome done on it, Fits most of the Standard size Burner having insulated holding handle on it. (c) On/Off High Pressure Gas Regulator. (d) ISI marked steel wire hose pipe mode for High Pressure Gass regulators Only. (e) Pressure Valve on Torch Pipe. (f) Jute Carry Bag with ZIP to hold blow lamp and its accessories up to 7 Kg. INSPECTION:CONSIGNEE | — | — | — | 29,453.2 | |
| — | 3.00 | — | — | ||
| Supply of Optical Time Domain Reflectometer for 1310/1550nm fiber with resolution of 60 Cms, dynamic Range of 314/29 dB with all accessories confirming to TEC Specification No. TEC Specification No G/OTD/02-03 March 2009.Make EXFO Model MAX 720C, AQ-7270+735022.Make Yokogawa Electric Co Ltd Japan or Similar. INSPECTION: CONSIGNEE | — | — | — | 4,29,132.99 | |
| — | 7.00 | — | — | ||
| Tool Kit consisting of Optical power meter (Fiber shot 9990V),Multimeter (Fluke101), Ethernet Crimping Tool (Standard Make) Console cable (Cisco= RJ 45-DB9), Wrist ripper (Standard Make), Universal Spanner Set (Taparia),Screw Driver Set (Taparia-7Pieces set),Cutting plier(Taparia), Wire Stripper, Industrial grade USB to Serial cable, Round Cutter, Cleaver, with all accessories or Similar. INSPECTION:CONSIGNEE | — | — | — | 1,46,724.69 | |
| — | 27.00 | — | — | ||
| Tools Kit for maintenance with small size canvas bag with following items :- 1)Combination Plier 8", 2) Long Nose Plier(Round Nose ) 6" , 3) Wire Striper Plier6" , 4) Screw Driver set ( 5 Piece) , 5) Hexa with frame 12" 6)Adjustable Spanner set 8" 7) Ball pin Hammer (200 gm) , 8) Side Cutting Plier6" 10) Soldering iron (Soldron make or similar) 11) Torch with cell (3 cell)(Eveready/ Geep or similar ), 12) Krone Tool (Krone make or similar) 13) Crimping Tool, 14) LAN Tester, 15) Wrapping and De Wrapping tool, 16) Visual Fault Locator, All Tool Item 1 to 9 of Taparia/Gedor/ Jhalani make or similar. INSPECTION:CONSIGNEE | — | — | — | 1,76,948.55 | |
| — | 176.00 | — | — | ||
| "Fabrication, supply and fixing of concrete cable marker as per RDSO drg. No. SDO/Cable Laying/020, dt.31.10.11. The marker shall be fixed at various places of cable route as per instruction of Eng. at site. INSPECTION:CONSIGNEE FOR SUPPLY PORTION" | — | — | — | 1,99,569.92 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_1.pdf
ATTACHMENT
ACSGCC22-231to6.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipno7-10.pdf
ATTACHMENT
TenderDocument0925-26Tresspass.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .