Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.7 LAccepted-AOC | 1 | Accepted-AOC being lowest and reasonable | |
| 2 | 2₹29.7 L+₹1.6 L (5.73%)Rejected-Finance | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹32.4 L+₹4.4 L (15.6%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹32.8 L+₹4.8 L (17.0%)Rejected-Finance | 4 | Rejected-Finance Not being the lowest bidder | |
| 5 | 5₹35.9 L+₹7.8 L (27.9%)Rejected-Finance NO 18 8 254 26 RAKSHAPURAM SAIDABAD POST HYDERABAD 500 005 | HYDERABAD | HYDERABAD | TELANGANA | 500005 | 5 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹40 L
Closing Date
22 Jan 2020, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIRS REPLACEMENT OF INTERNAL ELECTRIFICATION DISTRIBUTION SYSTEM INCLUDING FITTINGS AND FIXTURES AT RESIDENTIAL AREA UNDER GE I RND RCI HYDERABAD
2019_MES_309884_1
8532
Open Tender
Electrical and Maintenance Works
Works
335 days
GE I R AND D RCI
MES enlisted Class D category b i Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
Yes
7 Feb 2020
27 Dec 2019
27 Jan 2020
27 Dec 2019
22 Jan 2020
10 Jan 2020
Amount
Taking down copper/aluminium point wiring from surface/concealed conduit for light, fan, socket, bell or power complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc., removing materials from site or for refixing and making good disturbed surfaces of walls, floors, etc., to match with the existing complete all as directed.
M&L, Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5Sqmm (nominal area) multistranded with copper conductor drawn through in existing PVC conduit concealed in walls/floors/ceilings/roofs etc., with and including modular metal flush boxes made out of 1.6mm GI sheet with modular plate and frame for mounting of switches, socket outlets, regulators etc., complete including provision of FRLS PVC insulated unsheathed 1.5Sqmm copper conductor as earth continuity conductor and connecting to common earth dolly and making good disturbed surfaces to match with existing complete all as specified and directed for the following:-
One light/fan/bell point controlled by one, one way switch, 5/6Amp
One light point controlled by two, two way switch, 5/6Amp
One socket outlet, 3 pin, 5/6Amp, on independent board controlled by one way switch.
One socket outlet, 3 pin, 5/6Amp, controlled by one way switch on same board with other switches.
All as per item No. 2 above but with 2.5Sqmm FRLS cable for 5pin 15Amp socket outlet on independent board with 2.5Sqmm FRLS cable for the earth continuity conductor.
All as per item No. 2 above but with 4Sqmm FRLS cable for 20Amp AC socket outlet on independent board with 4Sqmm FRLS cable for the earth continuity conductor.
M&L, Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5Sqmm (nominal area) multistranded with copper conductor drawn through and including non metallic rigid PVC conduit, medium grade, of minimum 20mm dia (ISI marked) and conduit accessories concealed in walls etc., with and including modular metal flush boxes made out of 1.6mm GI sheet with modular plate and frame for mounting of switches, socket outlets, regulators etc., complete including provision of FRLS PVC insulated unsheathed 1.5Sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for the following:-
Note: Quoted rate shall deemed to include cost of making chases and making good to match with existing surfaces.
One light/fan point controlled by one, one way switch, 5/6 Amps
One socket outlet, 3 pin, 5/6Amps, on independent board controlled by one way switch.
One socket outlet, 3 pin, 5/6Amps, controlled by one way switch on same board with other switches.
All as per item No. 5 above but with 2.5Sqmm FRLS cable for 5pin 15Amp socket outlet on independent board with 2.5Sqmm FRLS cable for the earth continuity conductor.
All as per item No. 5 above but with 4Sqmm FRLS cable for 20Amp AC socket outlet on independent board with 4Sqmm FRLS cable for the earth continuity conductor.
S&F, Modular Switch 1 way 6Amps, 1 Module, ISI Marked complete all as specified and directed.
S&F, Modular Switch 2 way 6Amps, 1 Module, 240V, ISI Marked complete all as specified and directed
S&F, Modular Switch 1 way 16Amps, 1 Module, 240V, ISI Marked complete all as specified and directed.
S&F, Bell push modular type, one module 6Amp, ISI Marked complete all as specified and directed
S&F, Modular Socket, 6Amps - 2/3 pin combined, 2 Module, ISI Marked complete all as specified and directed.
S&F, Modular Socket, 6/16Amps - 2/3 pin combined, 2 Module, ISI Marked complete all as specified and directed.
S&F, Modular step type fan regulator, 100W, 2 module complete all as specified and directed.
S&F, Ceiling rose, surface type Bakelite, three terminal 65x50mm, ISI marked complete all as specified and directed.
S&F in repairs, CRCA sheet metal enclosure with metal clad plug and socket single phase with a two pin and earth plug & socket suitable for surface/flush mounting, 240V, 20Amp capacity controlled by and including one No 20Amp MCB SP 10KA complete all as specified and directed. Make: Legrand, Schneider, IndoAsian, L&T, C&S, Seimens
S&F in repairs, surface/wall mounting LED tube light fitting 1 x 9Watt LED batten indoor luminaire fixed on and including round PVC/bakelite blocks(2Nos) complete set with all accessories and LED tube rod and connecting electrically with twin core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Havells CAT No. LUMILINEBS9WLED830SPCWH or equivalent in Philips / Wipro
S&F in repairs, surface/wall mounting LED tube light fitting 1 x 20Watt LED batten indoor luminaire fixed on and including round PVC/bakelite blocks(2Nos) complete set with all accessories and LED tube rod and connecting electrically with twin core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Havells CAT No. LUMILINEBS20WLED840SPCWH or equivalent in Philips / Wipro
S&F in repairs, factory made sheet metal enclosure distribution board (MCB DB) SPN 8Way, with 100amps rated copper bus bar, neutral link and earth bar, metal door, powder coated, suitable for use on 240V, 50Hz supply, IP 43 IK 09 protection, MCBs used as out going, making good disturbed surfaces to match with existing complete all as specified and directed. Make: Legrand CAT No 5076 11 or equivalent in Siemens/L&T/IndoAsian/C&S as approved by GE
S&F in repairs, MCB, SP, 6 to 32Amps, 10KA, 240volts, ISI marked complete all as specified and directed. Make: Legrand Cat No 4085 87 to 4085 95 or equivalent in Siemens / L&T / IndoAsian / C&S as approved by GE
S&F in repairs, MCB SPN, 40Amps, 240volts, 10KA, ISI marked complete all as specified and directed. Make: Legrand Cat No 4086 18 or equivalent in Siemens / L&T / IndoAsian / C&S as approved by GE
M&L in repairs, Sub main wiring with 2 single core 6Sqmm 1100 Volts grade, FRLS PVC insulated, unsheathed cable, copper conductor, multistranded drawn through and including rigid PVC conduit, medium grade of minimum dia 25mm along with accessories concealed in walls etc, including provision of FRLS PVC insulated 6sqmm copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. Note:1. Two runs of cable, one run of earth continuity conductor and one run of PVC conduit shall be measured as unit length. 2. Quoted rate shall be deemed to include cost of making chases and making good disturbed surfaces to match with existing.
Taking down existing KWH meter and keeping in safe custody, refixing the same at a later date as directed including necessary electrical connection from main to KWH meter and KWH meter to outgoing DB complete all as directed.
M&L in repairs, Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to GI wire 4mm dia as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed.
Note: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:2:4 type B-1 using 20mm graded stone aggregate, 50mm thick cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 15mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II.
M/s ANUSHA ENTERPRISES
Brite electricals
M/S DIVIJA BUILDERS
saradhi construction combines
M/S VASU ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .