| 1 | L1₹38.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹43.9 L+₹5.2 L (13.4%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹46.7 L+₹8.0 L (20.7%)Rejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹48.0 L+₹9.2 L (23.8%)Rejected-Finance KASHIJORA P O BENAPUR DIST PASCHIM MEDINIPUR | BENAPUR | PASCHIM MEDINIPUR | WEST BENGAL | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
1 Nov 2023, 6:00 pmClosed
MAJOR M K TADAV, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
SPECIAL REPAIRS TO SPORTS SECTION BUILDING (P-30) AND DHOBI GHAT (P-43 AND P-44) AND PROVISION OF STABILIZER, FLAME PROOF FITTINGS, MOTORS AND PREPAID METER AT AF STN SALUA UNDER GE (AF) KALAIKUNDA
2023_MES_621155_1
C/8897/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹96,000
Yes
16 Nov 2023
30 Sept 2023
2 Nov 2023
30 Sept 2023
1 Nov 2023
14 Oct 2023
Amount
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete to receive roof treatment all as specified and as directed.
Demolation of cement concret(reinforced) Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing of debris from premises complete all as specified and as directed.
Taking out of old damaged unserviceable tarfelt or membrane of any description including screed bed or bedding layer and removing of debris from premises and cleaning roof surfaces by brushing etc and washing down with water and removing dirt, dust etc complete to receive roof treatment all as specified and as directed.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling with cement mortar (1:4) with using WPC as per manufacturers instruction over two coast of primer mixed of Latex and cement @ 1:4 (by weight) in the grooved portion and extended upto 100 mm both sides of groove complete all as specified and as directed.
M&L for 40 mm thick (Average) cement concrete type B-0, 1:2:4 using 12.5 mm graded aggregate as in roof padding, levelling course or similar work in order to maintain proper slope and camber finished the surface fair and even complete all as specified and as directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 (to be laid when concrete is still green) with water proofing compound for roof as per Manu-factuerer’s Instructions, complete including ponding test for 72 Hrs all as specified and as directed. (Note : WPC will be measured and paid separately)
M & L for Brushing neat cement slurry with 3.0kg of cement per sq. metre over the existing concrete(Roof) surface (To be applied where no levelling course/roof padding applied, before laying screed bed)
M & L for one coat of cold bitiminous primer (IS 3384) @ 0.25 Ltr/sqm apply evenly including cleaning of surfaces complete all as specified and direcetd
M&L for laying APP based polymeric membrane minimum weighing 3.5Kg/sqm and mimimum 3mm thick reinforced with polyster non woven fabric (weighing. not less than 160 gms/sqm) laid on primed surface by torch application complete all as specified and direcetd. The overlaps shall be minimum 100 mm on the transverse direction and 75mm on longitudinal direction.
M&L for one coat of aluminium paint @ 0.11 kg/sqm over the APP modified membrance including preparation of surfaces.
M&L for PCC 1:2:4 type BO using 12.5 mm graded aggregate as in haunching. Kerb in roof, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, or similar work complete all as specified and as directed.
M & L for RCC M-25 design mix concrete with using 12.5mm graded stone aggregates as in chajja, balcony, landing etc.; , all as spd and directed
Use and waste of form works (steel plate stiffened with steel angles, steel pipe scaffolding telescopic or otherwise) to sides and soffits of floor or roof beam,lintels, cantilevers, shelves including support, overhangs etc for rough finished surface of concrete complete all as specified and as directed.
Use and waste of form works (steel plate stiffened with steel angles, steel pipe scaffolding telescopic or otherwise) to chajjas etc .for rough finished surfaces of concrete complete all as specified and as directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Materials and Labour for rendering 5mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 10mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, at any height and safety measures complete all as specified and directed. Note: - (Water proofing compound will be measured and paid separately)
Supply only Liquid water proofing compound conforming to IS: 2645 - 2003 specification complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:6 on other than fair faces of brick work surfaces finished even and smooth without using extra cement complete all as specified and as directed., at any height and safety measures complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on fair face of concrete surfaces as in ceiling, chajja, shelves etc. finished even and smooth with out using extra cement at any height and safety measures complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls, and applying two coats acrylic distemper on wall ,over and including with a coat of 1.5 mm thick white wall care putty premium quality over and including a coat of primer new plastered or unplastered surfaces on wall, complete all as specified and as directed.Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M&L for preparing old decorated plastered or unplasterd surfaces of wall including cornices, pilasters and other wall features etc by brooming down or steel wire brushing/sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat acrylic distemper on old surfaces complete all as specified Make;Berger (Bison)/J&N(Jensolin)/Asain Piants(Tractor)/Nerolac(Beauty)
M & L for preparation of newly plastered surfaces of ceiling and applying three coat of white wash on new surface at any height and safety measures complete all as specified and directed.
Material and Labour for applying two coats of cement-based paint, white or tinted to new plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces at any height and safety measures complete all as specified and directed.
M&L for preparing old decorated plastered or unplasterd surfaces of ceiling including cornices, pilasters and other ceiling features etc by brooming down or steel wire brushing and sand paper, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and removing extra wall papdi ,peel off wall papdi by sand paper at any height and safety measures and making good with putty as per existing thickness and applying one coat of white washing on ceiling all as specified and directed
M&L for complete removal of existing treatment from walls and applying two coats of cement-based paint, white or tinted to old plastered surfaces on walls including priming with alkali resistant priming paint and including preparation of surfaces at any height and safety measures complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of green
Materials and Labour for, Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 018 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Non - skid Ceramic tiles, coloured, 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,conforming to IS 15622, Grade B II, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:4),complete all as specified and directed.
Materials and Labour for, Digital glazed ceramic coloured tiles, 450 X 350 X 7mm thick, conforming to IS 15622, Grade B III, on vertical surface of wall such as dados,skirting etc, set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
M&L Machine cut Kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 20 mm thick screed bed or bedding layer of cement mortar (1:4), complete all as specified and directed.
All as per BOQ Item No 31.00 here-in-before but as in risers of steps, skirting, dado, pillar ect.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
Taking down chowkats of frames wth shutters (without taking out off shutters from the frame) exc 1.5 sqm and n exc 4.00 sqm each including hold fasts and removing the same from site complete all as specified and as directed. (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete.)
S&F Anodised aluminium frame for doors,windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified
S&F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F 140mm (Overall length of cover plate ) Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in bottom body of the door complete all as specified and as directed.
S&F double action concealed type floor springs (hydraulically regulated) made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel top cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S&F exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
S&F aluminium Mortice lock, 4 lever, vertical type, size 100 mm
Supply and Fix, steel ventilator with top hung shutter including hinges, steel peg stay, complete, dovetailed or welded, including making good disturbed surfaces as per existing specfication complete all as specified and directed.
S&F 3 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 4.8 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Supply and Fix, factory made solid panel Plain PVC door shutter 30 mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded prelam PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail: Panelling of both sides plain PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, fixed to door frame complete all as specified and directed.
Supply and Fix, solid PVC door frame of size 50 mm X 47 mm made out of 5 mm Prelam PVC sheet reinforced with MS square tube, fixed in opening all as specified and directed.
S & F 20mm bore PVC coated MS conduit drapery rods, suitable for door/widows curtain with incl necessary fancy type dooms as approved by GE, and fitted to each end, brackets and fixed to wall complete all as specified and directed.
S & F pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, size 125 mm X 60 mm, Profile C, single rebate or more including hinges, mortar guards, lock strike plate, shock absorbers complete all as specified and as directed.
Materials and Labour for plain cement concrete (1:3:6) type C0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, filling of pressed steel door frame, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
S & F 35 mm thick, factory made, panelled shutters (two panels) with lock rail and panel of 12 mm thick veneered particle board, Grade -I, Type -I (solid core, general purpose), designation (SO GP-I) conforming to IS 3097 supplied and fixed to chowkhats. The size of style and rail as per IS 1003 (Part I) kiln seasoned and chemically pressure treated complete all as specified and as directed.
M & L for 35 mm thick,Factory made , glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed by the Engineer-in-Charge.
S&F 150mm long mild steel ordinary quality rat rail rod pattern spring including roller plate complete fixed to steel surfaces including necessary welding complete all as specified and directed.
S&F 150mm aluminum extruded aluminium alloy handles (fabricated type) anodised of mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S&F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S&F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F 4 mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in square not exceeding 0.5 sqm in each pane complete all as specified and as directed.
Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed.
All as per BOQ Item No 59.00 here-in-before but of one coat on old steel surfaces.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for 50mm thick PCC 1:3:6 type C1 with using 20 mm graded stone aggregate as in plinth protection laid in panels with 10mm joints at 3m interval and corner, finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
M&L for filling joints of depth 50mm with bitumastic mix with 80/25 bitumen and coarse sand mixture. 1:3 by weight
S&F 1000 ltrs IS marked multilayer rotational moulded polythytene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with and including 25mm PTMT ball valves high pressure with polythene float and nut with and including dismantling exsiting one complete all as specified and directed .
Taking up or down, steel tubing 15 mm bore, and connection including cleaning for re-fixing or removal from site of work complete all as directed.
Taking up or down, steel tubing 20 mm bore, and connection including cleaning for re-fixing or removal from site of work complete all as directed.
Materials and Labour for galvanized steel tubing, medium grade, 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed.
Materials and Labour for galvanized steel tubing, medium grade, 15 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor, complete all as specified and directed.
Refixing old steel tubing and connections 15mm bore in new or old position (wall, ceiling , floors) etc complete all as specified and as directed.
Refixing old steel tubing and connections 20mm bore in new or old position (wall, ceiling , floors) etc complete all as specified and as directed.
Supply and Fix in repairs , stop valves, cast copper alloy , fancy type, chromium plated, screwed down, high pressure with long shank and cup (concealed type), screwed both ends for steel pipe of for unions, 15 mm bore, complete all as specified and directed.
Supply and Fix in repairs , stop valves, cast copper alloy , fancy type, chromium plated, screwed down, high pressure with long shank and cup (concealed type), screwed both ends for steel pipe of for unions, 20 mm bore, complete all as specified and directed.
S&F in repairs PVC ball valve 20mm dia high pressure of PTMT with aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and directed .
S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed.
S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant and including CP jet nozzle for EWC incuding connection to GI pipe line complete complete all as specified and as directed by Engineer-in-Charge.
S&F in repairs Vitreous China urinals, half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S & F of 15mm size PVC connections with PTMT nuts of length 450mm complete all as specified and directed.
M&L in repairs Cast iron floor trap for 100 mm dia outlet, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4)
S&F in repairs Tubular towel rail, 20mm dia, D type, 60cm long between flanges
Taking down eaves gutters and rainwater pipes (any size or pattern), soil waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, fixed to walls incuding mild steel clamp @ 1metre C/C complete all as specified and directed by Engineer- in- charge .
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and directed by Engineer- in- charge
S&F in repairs CI cowl 100mm dia complete all as specified and as directed.
S&F in repairs CI P or S trap with horn 50mm dia complete all as specified and as directed.
Supply and Fix in repairs, bib tap, cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule,15 mm bore and fixed, complete all as specified and directed.
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in any kind of soil.
Removing excavated material ( Soil) n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M&L for cement concrete ( 1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified
M&L Brick work with flyash bricks old size bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:4 complete all as directed.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work surfaces finished even and smooth without using extra cement complete all as specified and as directed.,
Forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc..
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep & getting out in soft / loose soil all as specified
M&L for 50mm thick PCC 1:2:4 type B2 with using 40 mm graded stone aggregate as in sub base to floor finished rough to receioved the top layer complete all as specified and directed by Engr-in-Charge.
M&L for hardcore of gauge n,exc 63 mm, deposited, spread and levelled in layers n,exc 15 cm thick,watered and rammed to a true surface complete all as specified.
M&L for machine pressed precast concrete interlocking paver block of any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade laid over 50 mm thick sand cushion complete all as specified and approved by Engineer-in-Charge.
Dismantling Wrought Iron or Mild Steel Work, viz. Mild Steel Flat Iron, Mild Steel Bars, Bends, Straps and Similar Work including Mild Steel Bolts, Nuts, etc., fixing to RCC Fencing Posts, Struts, etc. complete all as specified and as directed.
Supply and fixing framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barried iron doors, ladders, framed balusters, walk ways, railings, and similar work conforming to FE.290.Gde-E-165
S&F Welded steel wire fabric supplied and fixed complete to wood or steel members, Weight per square metre n.exc 4.00kg
M&L for 40 thick PCC 1:2:4 type B1 with using 20 mm graded stone aggregate as in floor laid in panels finished even and smooth with using extra cement , complete all as specified and directed by Engr-in-Charge
M&L for 25 thick PCC 1:2:4 type B1 with using 20 mm graded stone aggregate as in floor laid in panels finished even and smooth with using extra cement , complete all as specified and directed by Engr-in-Charge
Plastic dividing strips, 38mm width and1.5mm thick and inserted in position, conform to design
Plastic dividing strips, 22mm width and1.5mm thick and inserted in position, conform to design
Material and labour for mild steel TMT bar 10mm dia over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooping end binding with mild steel wire not less than 0.9 mm all as specified.
S&F TMT reinforcement bar, conforming to Fe-500, 5mm dia and upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as binding with and including mild steel wire (Annealed) not less than 0.9mm dia or securing with clips all as specified.
M&L for precast RCC (1:2:4) type B-1using 20 mm graded stone aggregate as in cover slab for manhole, set in cement mortar (1:4) complete all as specified.
S&F TMT reinforcement bar, conforming to Fe-500, 6 to 8mm dia cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with chips.
Materials and Labour for plain cement concrete (1:2:4) type B0 using 12.5 mm graded aggregate in lintels up to 1.5m clear span, cills, filling of pressed steel door frame, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles throating,and roof padding as directed including necessary from work complete all as specified and directed.
Demolition and breaking up drain pipes 100mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar
Material and labour for 100mm bore DWCPE pipes laid and jointed complete with collars
M&L Cement Concrete (1:3:6) Type C2 (40mm Graded Stone Aggregate) Bed for Drain Pipes of Bore 100mm including Packing under and Haunching against the Sides of Pipes after they are laid in Foul Condition and Testing, complete all as specified and as directed.
Taking down carefully point wiring for one light, socket or power etc incl all fittings such as switches sockets, holders, light fittings, fan requlators etc and making good the disturbed surface of wall, ceiling etc including seperating serviceabel light fittings, switches etc and keeping in safe custody for reuse and removal of unserviceable materials from site complete all as specified and directed.
M & L for concealed point wiring complete with 1.5 sq mm FRLS,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC insulated 1.5 sq mm copper conductor for earth continuity (Green Colour) and connected to common earth dolly and including pressed steel terminal flush boxes made out of 1.6 mm thick MS sheet or modular metal flush boxes conealed in wall and laminated sheet cover of 3 mm thick for housing the switches, socket outlet, regulator, etc. all as specified and directed by Engineer-in-Charge.,all as specified and directed by Engineer-in-Charge for one light point controled by one one way 5/6 Amp switch Note:- (a) Cost of PVC conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface, box and cover plate are deemed to be included in the quoted rate.
All as per BOQ item No 115.00 here-in-before but for one fan point controled by one one way 5/6 Amp switch
All as per BOQ item No 115.00 here-in-before but for one 5 pin socket outlet 06 Amps on independent board (but Not below the switch board of light points in the same vertical plane)
All as per BOQ item No 115.00 here-in-before but for one 5 pin socket outlet 06 Amps on same board
All as per BOQ item No 115.00 here-in-before but for one bell point controled by one bell push switch
All as per BOQ item No 115.00 here-in-before but for one power pointt using by 2.5 sq mm copper conductor cable with 2.5 sq mm PVC insulated single core copper cable for earth continuity conductor, on independent board
Supply & fixing switch piano flush button AC 230 V single pole 5/6 Amps one way.
Supply and fix switch socket combination 6 Amp 5 pin flush type as specified and directed.
Supply & fix switch socket outlet combination, multipurpose 5/15 Amps flush type universal all as specified and directed.
Supply & fix bell push flush type 5 Amps
Supply & fixing call bell SP 230 volts Ding dong type
Supply & fixing ceiling fan regulator,electronictype,step type 5 variable speed AC, 230 volts all as directed by Engineer-in-Charge
Supply and fixing for sub main wiring with two run of single core FRLS 4 Sqmm PVC insulated unsheathed stranded cable copper conductor drawn in including through PVC conduit with all fittings including 4.00 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC concealed conduit complete all as specified and as directed by Engr-in-Charge including taking out complete existing sub main wiring with conduit. Note : (i) Two run of single core cable 4 sq mm and one run earth wire 4 sqmm and one run of PVC conduit will be measured as one length.
Supply and fixing for sub main wiring with two run of single core FRLS 6 Sqmm PVC insulated unsheathed stranded cable copper conductor drawn in including through PVC conduit with all fittings including 6.00 sq mm PVC insulated unsheathed single core copper conductor as earth wire and including PVC concealed conduit complete all as specified and as directed by Engr-in-Charge including taking out complete existing sub main wiring with conduit. Note : (i) Two run of single core cable 6 sq mm and one run earth wire 4 sqmm and one run of PVC conduit will be measured as one length.
S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 200 amps rated copper busbar, 8 way Double door enclosure made up of CRCA sheet steel, RAL powder coated, IP 43,IK09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with and electrically connecting up complete all as specefied and directed. by Engr-in-charge
S&F MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S&F MCB SPN 240 volts 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge .
S & F in repair LED street lights nominal power 35 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 3000, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S&F LED 20 Watt tube light fitting (T8 type), single/double side connection type including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2100, lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, life span of minimum 50000 working hours complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed:
Supply and Fix, Heavy Duty Exhaust Fan, 300 mm sweep with louvers(steel), 1400 RPM, Single Phase, 230 V, 50 Hz, and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 0.50 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan with and including cutting holes of adequate size and making good the disturbed surfaces as per existing, suitable for fixing exhaust fan for complete all as specified and directed by Eng in Charge.
Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 3.0 mtr deep below ground level) with top edge of the plate not less than 2.4 mtr below ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pit in hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Marconite, (4 bags of 25 Kg each ), construction of inspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 20 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately (Note : (i) Contractor shall use low reisistivity fresh agriculture soil , mixed with 04 bags Marconite (25 Kg each bag) for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 04 x Bags of marconite deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. (v) Contractor has to submit test report of earthing after completing the earthing. (vi) Bentonite clay should be Conf to IS 6186: 1986. (vii) The cost of Copper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. (viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (viiii) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (ix) Cost includes removal of excavated soil upto a distance of 100 mtrs.
M & L for concealed point wiring (flame proof) complete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red Colour use for Phase & Black Colour use for Neutral),drawn into and including stove enamelled steel conduit of suitable size and conduit accessories fixed on wall, floor, roof etc. and including provision of PVC insulated 1.5 sq mm copper conductor(FRLSH) for earth continuity (Green Colour) and connected to common earth dolly and including pressed steel terminal flush boxes made out of 1.6 mm thick MS sheet concealed in wall including sheets for housing switches, socket outlet etc.,all as specified and directed by Engineer-in-Charge for fan/light point controled by one one way 5/6 Amp switch Note:- (a) Note :- Cost of Steel conduit, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. (b) Accessories shall be suitable for flame proof wiring
Supply & fixing switch flame proof rotary type with termination box in LM 6, 16 A , single pole 250 V.
Supply and fixing LED light fitting 1x16/20 Watt flame proof, CMRI certified recommended for gas /vapor group of II A & III B, Zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holder, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size
Supply and fixing of wall mounted fan of size 300 mm complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output Voltage stabilizer at 230 V with accuracy of + 2.5% and of capacity 4.0 KVA incl connection, installation and testing complete all as specified and as directed.
Supply testing installation of 1 Hp self priming monoblock pump with and including 25 mm bore GI pipe (Class 'B') of 3 mtr length for inlet & out let both, head range 6-56 m, discharge range 4200 L/h-640 L/h, 220 V including fixing in position complete all as specified and directed.
Supplying and fixing smart single phase four wire energy meter BIS 16444 2015 (Reaffirmed 2020) marked in existing meter board/ floor panels having current range 10-60 Amp, 240 Volts , accuracy class 1.0
SUMAN CONSTRUCTION
NATIONAL CONSTRUCTION CO
M/S Tapan Sur
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .