Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹69,200Qualified Make: BPE
Model: BPE 1kva Line INteractive 7 ah 2 nos battery 2 years AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE 1kva Line INteractive 7 ah 2 nos battery 2 years | L1 | Qualified | |
| 2 | L2₹76,000+₹6,800 (9.83%)Qualified Make: BPE
Model: BPE & UPS 1000V 1ST FLOOR SHOP 2 BELOW HOTEL BARBAREEK ANJALI MAWLONGHAT EAST KHASI HILLS MEGHALAYA 793002 | EAST KHASI HILLS | MEGHALAYA | 793002 | Make: BPE
Model: BPE & UPS 1000V | L2 | Qualified | |
| 3 | L4₹78,000+₹8,800 (12.7%)Qualified Make: Artis
Model: Artis PS-600VA 28 A 28 A AJANTA COMMERCIAL CENTER ASHRAM ROAD INCOME TAX AHMEDABAD 380014 INCOME TAX AHMEDABAD CITY GUJARAT 380014 | AHMADABAD | GUJARAT | 380014 | Make: Artis
Model: Artis PS-600VA | L4 | Qualified | |
| 4 | L5₹79,980+₹10,780 (15.6%)Qualified Make: microtek
Model: TGE PRO1000+ 548 C 254 CHANDRODAYA NAGAR DEVPUR RAJAJIPURAM LUCKNOW LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | Make: microtek
Model: TGE PRO1000+ | L5 | Qualified | |
| 5 | L6₹80,000+₹10,800 (15.6%)Qualified Make: zebronic
Model: zebronic) (Zebronics UPS ZEB-U1200) 2 SHAH MARKET KATPIECE GALI BOMBAY BAZAR KHANDWA MADHYA PRADESH 450001 | EAST NIMAR | MADHYA PRADESH | 450001 | Make: zebronic
Model: zebronic) (Zebronics UPS ZEB-U1200) | L6 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
7 Aug 2018, 11:00 amClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 As per GeM Catalogue. Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC
50 Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP 20 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year 1 year
3 Years Warranty for Line Interactive UPS 2 Years 2 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for Yes Yes
No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Daulat Ram Bhardwaj 785005
5 AIR FORCE HOSPITAL ROWRIAH JORHAT ASSAM-785005 20 15
367616
GEM/2018/B/52077
Line Intractive UPS with AVR
15 days
Assam
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 20 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/800 As per GeM Catalogue. Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC | - | - | - |
| 50 Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP 20 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year 1 year | - | - | - |
| 3 Years Warranty for Line Interactive UPS 2 Years 2 Years Installation and commissioning instructions Yes - CONSTRUCTIONAL Type of enclosure ABS - AC out put for Yes Yes | - | - | - |
| No 1/4 printer (not through inverter) Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Yes - Dry heat Test at 45 Yes - 2/4 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date - - Name Of Lab - - Address of Lab - - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Daulat Ram Bhardwaj 785005 | - | - | - |
| 5 AIR FORCE HOSPITAL ROWRIAH JORHAT ASSAM-785005 20 15 | - | - | - |
Exempted
7 Aug 2018
23 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_367616.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .