| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹58.1 L+₹15.7 L (37.0%)Rejected-Finance | L2 | Rejected-Finance Other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
10 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
PROVISION OF CERTAIN EM SANCTIONED WORKS AT NCC ENCLAVE AND AF STN GORKHPUR
2021_MES_472252_2
8786/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per tender Documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹90,000
Yes
4 Dec 2021
21 Oct 2021
11 Nov 2021
21 Oct 2021
10 Nov 2021
28 Oct 2021
60 days
Amount
S&F iron removal filtration plant with capacity 68 cubic meter / 15000 GPH during normal flow rate designing of water filter maximum limit during monsoon, plant with the limit for portable use as per IS 10500 complete all as per specified and directed. Make: RMCO Model No. Ferrotrear Vir 101530FC or equivalent of other specified make TECHNICAL SPECIFICATION:-IRON REMOVAL FILTER -68000 LPH /15000 GPH:- Vertical, Single deck and multigrade , Shell:-2650 mm dia x 2000 mm SOH with thickness body , Dish end & bed plate 8 mm x 10 mm x 10 mm (i) Frontal (face) pipe line will be fabricate from 150 mm ERW pipe (medium). (ii) Valves in frontal pipe line ,butter fly valves flange less finish suitable to mount between two flanges (wefer-leve ) -150 mm (iii) Filter media (sand & gravels) 207 CFT /5.9 Cum (iv) Under bade plate system with strainer double nut type PVC strainer 530 Nos (v) Oxidation chamber Vertical single deck (vi) Shell-1200 mm dia x1500 mm SOH (vii) Thickness of body, Dish end & bed plate 6mmx8mmx8 mm. (viii) Mno2 compound 52 cft /1.4 cuM (ix) Air compressor 5 HP 21 CFM -Model DH -10 (x) Pressure gauge with fittings 02 sets for raw and filter water
Supply and laying iron pressure pipe 100mm dia centrifugally cast (spun) with flange end cast Class “K-7” with internal metallic zinc coating and external blade bitumen complete all as specified and directed.
S&F DI fitting for 100 mm bore DI flanged pipe such bend (any type radius and angle) taper any type, (straight bends, increasing, decreasing or double socket etc.) complete all as specified and directed.
S&F cast iron sluice valve of size 100 mm dia class PN- 1.0 confirming to IS-14846 flanged and drilled hole having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling or mass concrete complete all as specified and directed.
M&L for brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or on concrete surface in CM 1:4 finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for hard core of broken stone or boulders gauge n exc 63mm deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor concrete complete all as specified and directed.
M&L for 40mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in hard standing, surface finished even and smooth without using extra cement complete all as specified and directed
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for preparation new plastered surface wall and applying two coat of cement base paint over one coat of alkali resistant primer complete all as specified and directed.
Cutting of cast iron pipes of 100 mm bore in position for insertion of new tees, branches etc including diverting due to residual water in pipes complete all as specified and directed.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note:-(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, shall be measured and paid separately.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 2.5 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 2.5 sqmm conductor cable, 1 No 1.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
S&F switch piano, flush type 15 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, flush type, 2 in 1, 3 pin 5 & 15 Amps, 230 Volts, multipurpose complete all as specified.
S&F sheet metal enclosure distribution board SPN 2 ways complete all as specified and directed.
S&F MCB SPN 20 to 40 Amp 240 volts 10 KA breaking capacity 'C' curve complete all as specified and directed.
S&F, installation, testing of electric Water heater storage type geyser (with powder coated metal body) of capacity 25 litres suitable for single phase 230 Volts, AC, 50Hz, BEE 5 star rating complete with all mounting arrangement, Hot & Cold water connection pipe, 3 pin plug top etc as required at site complete all as specified and directed. Make: Model New shakti 150743- 25L of make Bajaj or equivalent in V-Guard/Havells/ Racold Note:- Any disturbed surfaces of wall will be matched with existing colour surfaces. complete all as specified.
S&F GI tubing, 15 mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors properly fixed in concealed to wall/tile surface and making / matching good the surface as the existing colours, materials complete all as specified and directed.
M&L for making hole in brick wall n.exc. 25mm in dia, pinning in, making good to facings where required and pointing in cement mortar 1 :3 for concealed water tubing and making good the disturbed surfaces of wall and color matching complete all as specified and directed.
M&L for cutting/opening/threading of existing steel water tubing of size upto 25mm dia for and including insertion of tee reducer for branch connection of 15mm bore pipe all as reqd and as directed.
S&F brass non return valve heavy duty (ISI marked) for any type/make and capacity of Geyser suitable for 15mm bore pipe complete all as specified and as directed.
S&F bib tap 15mm bore, chromium plated fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F angle valve 15mm bore, cast copper alloy, chromium plated with long shank and cup screwed down, high pressure, with crutch of butterfly handle, screwed both ends for iron pipes or for unions complete all as specified and directed.
Taking out old existing LT UG cable of any size from trench and relaying of LT cable after repair in trench including taking out and refilling sand and bricks complete all as specified and directed. Note:- Earth work will be measured and paid separately under relevant item.
Surface dressing n.exc. 15 Cm deep in soft / loose soil incl removal of brick / stone pieces, herbs, shrubs & vegetation and tree cutting in surrounding areas of installation complete all as specified and directed.
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for concealed point wiring for one light/fan point controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. Note:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
All as per item No. 32 above but for one 5 Amps socket point controlled by one 5 Amps switch on same board.
All as per item No. 32 above but for one 5 Amps socket point controlled by one 5 Amps switch on independent board.
All as per item No. 32 above but for one bell point controlled by one 5 Amps bell push.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type 240 volt complete all as specified and directed.
S&F bell push, flush type 5 amp, single pole, one way 240 volt complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
S&F Call bell ding dong, AC single pole 240 volts complete all as specified and directed.
S&F lamp holder polycarbonate insulated body with back plate suitable for batten fittings complete all as specified and directed.
Taking down old unserviceable light fittings conventional type from wall surface / ceiling or any position and making good the disturbed surfaces all as specified and directed.
S&F 10 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:-Havells Cat part No. ENDURA LINE ARNE OBS10WLED865SPCWH or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS20WLED865S PCWH or equivalent in Bajaj / CG.
S&F recess mounting LED luminaire of size 2'x2' white 34/35/36 watt, 230 volts for ceiling with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. Make:- Havells Cat part No. PLUTONEO2X2PLR34W LED840S or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F 15 watt highly efficient down light with efficacy of 100 lm/W with its IP44 rating, light fitting complete all as specified and as directed. Make:- Havells Cat part No. ENDURAHODLR15W LED 840MOD or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED flood light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:- Havells Cat No. ENDURA CITYLITEPLATPLUSSL35W LED 757SASYBOPC or equivalent iin Bajaj/ Philips/ CG/ WIPRO
S&F ceiling fan complete with all electronic fan regulator and accessories of capacity 230V, 1200 mm sweep, BEE 5 star rating complete all as specified and directed. Make: Havells, Model No. ES 50 Premium 5 or equivalent in Bajaj/ Crompton.
S&F exhaust fan single phase 230/240 volt AC 450mm sweep, with painted louvers, metal body, including cutting holes of suitable size in wall, grouting of nuts and bolt etc if required for fixing fan and making good to match the existing surface and making connection with twisted copper flexible wire 23/0.0076mm complete all as specified and directed. Make: Havells/Bajaj/CG.
Taking down old unserviceable MCCB DBs / MCB DB / Main Switches, complete all as specified and as directed. Note: Any disturbed surfaces of wall will be matched properly as the existing colour surfaces.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates all as specified & directed.
Taking down old unserviceable MCBs/ MCCBs/ Isolators, complete all as specified and as directed.
S&F MCCB, 4 pole, 125 Amps, 16 KA current rating with adjustable thermal and magnetic setting conforming to IEC-609472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TP, 25 to 63 Amps, 'C' curve, 10 KA breaking capacity, 415 volts complete all as specified and directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
Taking down carefully old and unserviceable sub main wiring of 2/3 runs or main-wiring of any size of aluminium conductor cable from any position including wood batten, PVC conduit, steel conduit, PVC Casing capping etc including making good disturbed surface of wall ceiling etc complete all as specified and directed.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 1.5 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 1.0 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 1.5 sqmm conductor cable, 1 No 1.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 6.0 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 6.0 sqmm conductor cable, 1 No 4.0 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
S&F PVC casing & capping of size 25 mm run in wall / ceiling surface for existing telephone cable / Lan cable complete all as specified and directed.
Disconnecting, taking down & removing carefully the existing ceiling fan, and hanging/fixing the repaired fans in position, connecting to existing electric sources and testing at site to the entire satisfaction of the department complete all as specified and directed. Note:- (i) The replacement of defective/ nonfunctional parts shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item here-in-after. (iii) The rates for above items are deemed to include transportation charges from E/M store yard to workshop and vice versa.
M&L for servicing / overhauling the ceiling fan by thoroughly cleaning the bearing, shaft, stator, rotor & applying the lubricant / grease to the bearing including applying one coat of super enameled varnish over the winding to improve the insulation value complete all as specified and directed.
Taking out & removing old burnt-out winding and rewinding of motor of ceiling fans 1200/1400 mm sweep of any description and rewinding of fan motor with appropriate size super enameled copper wire approx 200 gram including insulating material such as illumines paper, letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of the department. Make of winding wire: Atlas/Finolex/ Devi Dayal
M&L for painting of existing fans of any description (ceiling fan) with applying one coat of synthetic enamel paint (White) by spray machine including preparation of existing decorated surfaces of fans including engraving MES No. of fan in capital letters of height not less than 20 mm on fan body all as specified and directed.
M&L for dismantling and installation of existing split type AC 1.5TR / 2TR capacity in the location as directed including provision of 45x45x5mm angle iron frame work for mounting of out door unit , fixing of indoor unit after servicing with the following:- (i) Fixing of condenser unit with one number compressor and blower / fan housed in cabinet shell of weather proof factory made unit. (ii) Fixing of wall mounted evaporator unit housed in PVC cabinet including blower and supply air grill. (iii) Fixing of refrigerant piping made out of copper of 3/8" for discharge line and 5/8" for suction line duly insulated for required length as per site. (iv) Preparation of angle iron frame for condensing unit and painting with two coats of bituminous paint over a coat of primer as per site requirement. (v) PVC pipe for the drain water removal from the room Note : Extra refrigerant pipe will be measured and paid separately other than retrieved against removed one
S&F suction and discharge copper tubing 3/8" and 5/8" for split type AC including provision of insulation on the tubing complete all as specified and directed.
M&L for PVC insulated flexible multistranded copper cable 3 core 2.5 sqmm complete all as specified and directed
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
S&F 40mm bore GI pipe, light grade with all fittings laid in trenches, road crossing and fixed to walls, on poles etc for cable protection complete all as specified and directed.
Boring of holes horizontally for laying of 50 mm dia pipe (minimum depth 1200mm from top level) under road, Pavement, hard standing complete all as specified and directed.
Supply, laying and testing 70 Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve including taking out old cable complete all as specified and directed Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
M&L for earthing with Galvanised iron earth plate electrode 600x600 mm and 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal GL) with top of earth plate not less than 1.5 mtr below GL connected to GI earth lead wire of size 4 mm dia connected to earth plate electrode by means of GI nuts, bolts and washers of galvanised iron or steel protected with and including 15 mm dia med grade ISI marked GI pipe upto a length of 7.5 mtr long as shown in electrical plate No 5 of MES Sch Part-I with and including PCC 1:3:6, C-1 pit with cover or RCC 1:2:4 B1 reinforced with welded steel wire fabric not less than 4 kg per Sqm watering arrangement within 20mm dia GI med grade pipe ISI marked, GI funnel with GI mesh, filling with mixture of common salt and charcoal necessary excavation and earth work in soft/loose soil including connected to earthing test point, and main switch/DB, testing and commissioning complete all as specified and directed. Note: (i) GI earth wire with GI pipe protection upto 7.5 mtr shall be deemed included in the item.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or chases or buried in ground or drawn in conduit pipe fixed to pole or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and install and testing split type air conditioner of capacity 2.0 Ton, 5 star rating inverter type for working on 230 volt, SP, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface with existing surface and providing water pipe upto ground level complete all as specified and directed. Make : Carrier/Voltas/Bluestar/Hitachi/LG
S&F automatic voltage stabilizer for low and high voltage correction equipped with electronic transistorized relay suitable for operation single phase, AC, 50 HZ complete with Voltmeter, indicators and designed for input voltage 130 to 300 stabilized between 215 V to 220 V of capacity 5KVA (not less than 17 amp) complete all as specified and directed. Make : BLUE BIRD/Microtek /V Guard/ Logicstate
S&F 3 watt LED study light fitting 3 watt natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:-Havells/Bajaj/ Philips/ CG/ WIPRO
S&F prismatic cold water inlet pipe (connection) 450mm long with brass union and rubber washers complete all as specified and directed.
S&F hot water outlet pipe (connection) PVC wire coated with CP brass nut, bolt rubber washer for hot water supply complete all as specified and directed.
M/s Sinha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .