| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-Finance MES WORKS SITE CARNICOBAR ANDAMAN NICOBAR ISLAND PIN 744301 | CARNICOBAR | NICOBAR | ANDAMAN AND NICOBAR ISLANDS | 744301 | L1 | Accepted-Finance Admitted | |
| 2 | L2₹30.2 L+₹90,137.40 (3.08%)Accepted-Finance | L2 | Accepted-Finance Admitted | |
| 3 | L3₹30.8 L+₹1.5 L (5.21%)Accepted-Finance | L3 | Accepted-Finance Admitted |
Tender Value
₹26.8 L
EMD Value
₹53,600
Closing Date
28 Mar 2023, 6:00 pmClosed
GE (I) Campbell Bay
GE (I) Campbell Bay, Army land, Campbell Bay, Great Nicobar-744302
SPL REPAIR TO BUILDING NO P-50 AND P-61, SPL REPAIR/REPLACEMENT OF ROOF SHEET DOOR WINDOW OF 02 IN NUMBER OF PUMP HOUSE AND SPL REPAIR TO STAGING FOR OHT NEAR DSC LINE AND LADDER OF OHT NEAR HADR AT INS BAAZ UNDER GE (I) CAMPBELL BAY
2023_MES_578731_2
8052/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) Campbell Bay
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (I) Campbell Bay
₹53,600
30 Mar 2023
14 Mar 2023
30 Mar 2023
14 Mar 2023
28 Mar 2023
15 Mar 2023
Amount
Demolition of Plain Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame), n.exc 1.5 Sqm each complete all as directed.
Taking down chowkats or frame with shutters (without taking off shutters from the frame), exc 1.5 sq. m but n.exc 4.0 sq. m each complete all as directed.
Supply and fixing of Anodised aluminium frame for Partitions, doors, windows ventilators and grill with one or more rebates including joining cleat for fixing etc. Complete all as specified complete all as specified and directed.
Supply and Fixing of Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, mortice lock ,hinges, anodized aluminium snap beading, screws etc .complete all as specified and directed.
Supply and Fixing of Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
S&F of 5.5 mm thick Sheet Glass, ordinary quality and glazing with rubber packing where ever required complete all as specified and directed.
Supply and Fixing of Anodised aluminium grill any size 10 mm thick complete with frame or channel section including all necessary fittings complete all as specified and directed.
Supply and Fixing of 200 mm long Aluminium, anodized, barrel tower bolts of extruded section complete all as specified and as directed.
Supply and Fixing of 150 mm long Aluminium, anodized, barrel tower bolts of extruded section complete all as specified and as directed.
12mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws
Supply and fix alluminium alloy, anodized sliding door bolts 250 mm long with hasp and staple (bolt type) with fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy, ISI marked and fixed complete all as specified and as directed by the Engineer-in-Charge
S&F 140 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and as directed by the Engineer-in-Charge
M&L 100mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) laid in floor sub base cement concrete complete all as specified and as directed by the Engineer-in-Charge
M&L for 75mm thick PCC type C-2, 1:3:6 (40mm graded stone aggregate) laid in plinth protection/ floor sub base cement concrete surface even and smooth without using extra cement.
M&L for 75mm thick PCC type D-2, 1:4:8 (40mm graded stone aggregate) laid in floor sub base cement concrete surface even and smooth without using extra cement as in path complete all as specified and as directed by Engineer -In-Charge.
Material & labour for PCC 1:2:4 type B2 (using 40 mm graded aggregate) in foundation and mass concrete for angle iron post completed all as specified and as directed.
M&L 40 mm thick cement concrete 1 : 2 : 4 type B-0 (using 12.5mm graded crushed stone aggregate) laid in base, cement concrete surface even and smooth w/o using extra cement.
M&L for RCC M30 (Design Mix) using 20mm graded aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as directed.
M&L for RCC M30 (Design Mix) using 20mm graded aggregate Columns, pillars, piers, posts and struts complete all as directed
M&L for RCC M30 (Design Mix) using 20mm graded aggregate Roof Beams, tie beams cantilevers, bressummers, lintels over 1.5m span, slabs supporting to tanks complete all as directed
M&L for Formwork flat to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as directed
M&L for Formwork in square, rectangular or polygonal to sides of pillars, posts, struts, piers, columns and stanchions complete all as directed
M&L for Formwork flat to soffits of slabs and beams, similar work; complete all as directed.
M&L TMT bars 10 mm dia and over, cut to length bent to shape required incl cranking, bending, spirally hooping for columns and binding with MS wire (annealed) not less than 0.90mm dia wire etc complete.
All as per item No 26 above but 8 mm dia TMT bars as in stirrups complete all as specified and as directed by Engineer- In-Charge.
M&L for Pre-cast cement concrete block masonry type B1, 1:2:4, (using 20mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed by the Engineer In charge
M&L for 15 mm thick rendering in CM (1:4) on external surfaces surfaces finished even and smooth without using extra cement complete all as specified directed.
M & L for Glass diving strips 3mm thick, 38mm wide strip for internal floors complete all as specified
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including disconneting GI pipes inlet and outlet, refixing again after erection of staging complete including all fittings and fixtuires. (Cleaning repairing, etc. measured separately) of exc 4000 lts and n.exc 5000 ltrs complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for height upto 10m complete all as specified and as directed.
Ditto all as per item No.32 above but height exc 10m but n.exc 20 m.
S&F Mild steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. in cluding cleats, brackets, etc. complete and similar work conforming to Fe-290 Gde E-165 for height upto 10m complete all as specified and as directed.
Ditto all as per item No.34 above but height exc 10m but n.exc 20 m.
M&L for MS screw bolts (machine made) with hexangonal or squre head at one end screwd other or screwd end fitted with wishers and one hexogonal or square nut exc 5cm long emmbedded into concrete portion all as directed.
M & L for forming Contraction (Dummy) joints 65mm deep X 10mm wide, filled with cealing compound grade 'B' for path/ plinth/ external flooring complete all as specified
Complete removal of existing treatment on surfaces of walls complete all as specified and as directed by Engineer-In-Charge.
M&L for applying two coats of oil bound distemper on surfaces of walls over a coat of chalk whiting primer including preparation of surfaces complete all as specified and as directed by Engineer-In-Charge.
M&L for preparing of new surfaces and applying two coats of anti-fungal exterior emulsion paint over a coat of anti fungal primer on external surfaces of walls and ceilings/ chajjas projections complete all as specified & as directed by the Engr-in-Charge.
Removing excavated/ demolished material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified & as directed by the Engr-in-Charge
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F Steel work as in tubular trusses including special shaped washers etc, complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St 240 complete all as specified.
Material & labour for Applying two coats of synthetic enamil paint over a coat of red oxide zinc chrome primer on new surfaces of any description width exc 10 Cm complete all as specified and as directed.
ditto all as per item No.47 above but ht exc 10mtr and n.exc 20mtr complete all as specified and as directed.
Taking down old unserviceable point wiring and Material and labour for point wiring 1.5 sq mm FRLS Copper cable 1100 volt grade drawn in and including stove enamelled steel ERW conduit not less than 19mm dia including spacers, saddles, screws etc & 1.5 sqmm PVC insulated copper earth wire including connected to flame proof switches/sockets etc on independant all as specified and directed. Make of Wire : Polycab / Finolex / Plaza / Havells or equivalent
Taking down unsv point wiring and M&L for Point wiring with 1.5 Sq mm single core copper conductor FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid FRLS PVC rigid conduit and its accessories of suitable size, heavy grade ISI marked concealed on walls /roof and MS pressed steel terminal boxes of 1.6 mm thick of suitable size duly painted with red oxide metal primer including fixing/grouting sunken/ surface and making the adjacent surfaces smooth through POP work & painting as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for : a) One light point controlled by one switch. Make of wire : Polycab / Havells / Plaza / Finolex or equivalent Make of Conduit & its connected accessories : Modi / Sudhakar / Pressfit / Prestoplast or equivalent
(b) One socket 5 Amps on independent board.
Supply & Fix Switch piano, flush type single pole, one way 5 Amp complete all as directed
Supply & Fix Switch socket combination 2 in 1, 5 Amps flush type complete all as directed
Supply & Fix Ceiling rose PVC/ Polycarbonate insulated body with three terminals complete all as directed
Supply and fix surface mounting 20 W LED Tube light fitting nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70.The luminaire should have a color temperature of 6500K and CRI>83. pre wired connection up to tube light fitting with connecting up with copper 2 core flexible cord of minimum size 1.0 Sqmm and white in colour.The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The total power consumption should not exceed 20W (including driver) including taking down old unserviceable fittings any type including round block complete all as specified and as directed. Make : Phillips / Bajaj / CG / Wipro or equivalent
Supply & Fix Sheet metal enclosure for DB’s Single pole and neutral, double door 240V, 4 way with 100 Amps rated bus bar. Make : Legrand / L&T / Havells / Standard or equivalent
Supply & Fix MCB SP 6 to 32 Amps 10 KA. "C" Series Make : Legrand / L&T / Havells / Standard or equivalent
Supply & Fix MCB DP 32 Amps 10 KA. "C" Series Make : Legrand / L&T / Havells / Standard or equivalent
Supplying, laying or fixing, GI water tubing, medium grade, of size as shown below confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, flanges etc laid in tenches / floors or fixed to walls / ceiling / roof etc including testing GI tubing with fittings / connections, in trenches / celiling /walls/roofs 80 mm dia bore complete all as specified and as directed :- Make: Bansal / Jindal / Tata
Supply and fixing of Sluice valves PN 1.6 of size 80mm complete all as specified and as directed.
Supply and fixing of Non Return valves of size 80mm in the incomer line complete all as specified and as directed.
M&L for cleaning of RCC OHT 50000 Litres (inside) by dewatering the complete tank, removing the sediments settled at the bottom of tank, scraping with the help of shovels, hard brushes and physical cleaning of tanks (Reservoir) by de-scaling/brooming silt and sludge and other deposits from inner side (bottom of dome), collecting and taking them out with the help of manual labour and depositing at a distance not exceeding 50m and making the tank clean and washing properly with bleaching powder mixed with water (1:10) and applying two coats of white wash both internally and externally and writing the date of cleaning, due date of cleaning and capacity of tank in paint (white letters on black back ground) and the inner ladder with two coats of black synthetic enamel paint of exterior quality over a coat of red oxide primer and including removing of any vegetation growth on and around the tank complete all as specified and directed at site for following capacities:- Note:- (a) Work is to be executed at 18 to 25m height for ser No.1(a) (b) All necessary T&P, labours and materials will be arranged by the contractor
Taking down old unserviceable cable and M&L for XLPE insulated, armoured heavy duty underground electric cable with stranded aluminium conductor, 1100 volts grade of cross sectional area 10 sqmm 2 core laid in trenches / fixing on walls / poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed. Make : Polycab / Finolex / Gloster / Havells or equivalent
M & L HDPE Double Wall Corrugated (DWC)pipes,ISI marked,with outer diameter 50 mm and inner diameter 38 mm conforming to IS-14930 Part-II including necessary pipe fittings such as couplers,end caps,bends,clamps etc laid in trenches/on wall for cable protection complete for cable protection complete all as specified and directed by Engr-in-charge.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed.
Removing excavated materils (soil) not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed.
Supply & Fix Switch piano, flush type single pole, one way 5 Amp
Supply and fixing LED light fitting 1x8 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete including removal of old unserviceable one all as specified and directed Make : Bajaj / Shyam / Sudhir or equivalent
S&F sheet metal enclosure factory made double door for DB 240 volts with 200 amps rated bus bar SPN 4 way including removal of old unserviceable one complete all as specified and as directed. Make : Havells / L&T / Legrand / ABB or equivalent
S&F in repairs MCB SPN-20 amps, 'C' curve, 240 volts Make : L&T / Legrand / Havells / ABB or equivalent
S&F in repairs MCB SP 5 to 32 amps, 'C' curve, 240 volts. Make : L&T / Legrand / Havells / ABB or equivalent
M&L Sheet metal enclosure weather proof for mounting over wall / floor including locking arrangement for housing of 4 Way SPN DB & switches complete including removal of old unserviceable one all as specified & directed
M&L flameproof exhaust fan of 300 sweep complete all as specified & directed Make : Sudhir / Shyam / Bajaj / CG or equivalent
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of of suitable size, 3 Phase 4 wire system Indoor type 2 mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 120 Sqmm 3.5 Core in and out(Panel board shall have sufficent space to accommodate spare cables also) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 2 mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 type C1, consisting the following provisions:-
Design, fabrication, supply and errecting connecting and testing totally enclosed LT Cubical panel board of of suitable size, 3 Phase 4 wire system Indoor type 2 mm ,double door front and back openeing type sloped canopy(Hood) on top extended 100mm all-around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable up to 120 Sqmm 3.5 Core in and out(Panel board shall have sufficent space to accommodate spare cables also) , incoming and outgoing feeders duly marked on revited plates etc, CPRI approved factory made fabricated out of 2 mm thik CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy power coated mat finish of SIEMENTS GREY structral RAL 7032 shade colour, built in industrial type locking arrangement on front and back and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on angle iron frame of 50x50x6mm thick duly painted and embeded in PCC 1:3:6 type C1, consisting the following provisions:-
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized GI wire 4 mm dia (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 5 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reingorcement, watering funnel 15mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion.
Note : An amount of Rs 24,894.00 towards Schedule of Credit shall be deducted to arrive the Contract sum.
M/S G S GREWAL
bansal construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .