Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC | ₹47.8 L Quoted ₹49.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹50.0 L+₹60,639.29 (1.23%)Rejected-AOC PO VIKRAMKHAND ROAD LANE NO 05 HOUSE NO 16 ASSAM 788007 | CACHAR | ASSAM | 788007 | ₹50.0 L+₹60,639.29 (1.23%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹50.0 L+₹65,292.08 (1.32%)Rejected-AOC | ₹50.0 L+₹65,292.08 (1.32%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹50.1 L+₹70,194.74 (1.42%)Rejected-AOC | ₹50.1 L+₹70,194.74 (1.42%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹50.2 L+₹87,629.19 (1.78%)Rejected-AOC | ₹50.2 L+₹87,629.19 (1.78%) | L5 | Rejected-AOC Beign L5 |
| Sl No | Description | Qty | Unit | M/S TAPAN KUMAR RAY L6 | ABDUL AUDUD L9 | MS AFTAB LASKAR L7 | m/s builders and suppliers L5 | Bhuiya Construction L10 | MAGADH TRADING L3 | M/S SUBHAM ENTERPRISE L2 | M/S MOLOY KUMAR DEY L1 | SHRI YOUNUS KHAN L4 | M/S R A ENTERPRISE L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00B & R Division Items | |||||||||||||
| 2.00 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. | 29.3 | Cum | 155 ₹4,541.5 | 170 ₹4,981 | 300 ₹8,790 | 155 ₹4,541.5 | 1,200 ₹35,160 | 152 ₹4,453.6 | 158 ₹4,629.4 | 150 ₹4,395 Lowest | 160 ₹4,688 | 162 ₹4,746.6 |
| 3.00 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. | 11.21 | Cum | 310 ₹3,475.1 | 300 ₹3,363 Lowest | 307 ₹3,441.47 | 305 ₹3,419.05 | 700 ₹7,847 | 305 ₹3,419.05 | 312 ₹3,497.52 | 300 ₹3,363 Lowest | 333 ₹3,732.93 | 312 ₹3,497.52 |
| 4.00 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. | 5.68 | Qtl | 190 ₹1,079.2 | 165 ₹937.2 Lowest | 400 ₹2,272 | 190 ₹1,079.2 | 800 ₹4,544 | 185 ₹1,050.8 | 192 ₹1,090.56 | 180 ₹1,022.4 | 194 ₹1,101.92 | 192 ₹1,090.56 |
| 5.00 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. | 706 | Sqm | 53 ₹37,418 | 54 ₹38,124 | 48 ₹33,888 Lowest | 60 ₹42,360 | 55 ₹38,830 | 52 ₹36,712 | 55 ₹38,830 | 50 ₹35,300 | 56 ₹39,536 | 52 ₹36,712 |
| 6.00 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed. | 0.3 | Cum | 554 ₹166.2 | 562 ₹168.6 | 555 ₹166.5 | 558 ₹167.4 | 565 ₹169.5 | 552 ₹165.6 | 555 ₹166.5 | 550 ₹165 Lowest | 560 ₹168 | 560 ₹168 |
| 7.00 | Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. | 55 | Sqm | 114 ₹6,270 | 122 ₹6,710 | 118 ₹6,490 | 115 ₹6,325 | 125 ₹6,875 | 112 ₹6,160 | 115 ₹6,325 | 110 ₹6,050 Lowest | 118 ₹6,490 | 120 ₹6,600 |
| 8.00 | Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. | 86 | Sqm | 114 ₹9,804 | 122 ₹10,492 | 118 ₹10,148 | 115 ₹9,890 | 125 ₹10,750 | 112 ₹9,632 | 115 ₹9,890 | 110 ₹9,460 Lowest | 118 ₹10,148 | 120 ₹10,320 |
| 9.00 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. | 2 | Each | 345 ₹690 | 358 ₹716 | 350 ₹700 | 345 ₹690 | 360 ₹720 | 342 ₹684 | 348 ₹696 | 340 ₹680 Lowest | 348 ₹696 | 355 ₹710 |
| 10.00 | Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. | 2 | Each | 345 ₹690 | 358 ₹716 | 350 ₹700 | 345 ₹690 | 360 ₹720 | 342 ₹684 | 348 ₹696 | 340 ₹680 Lowest | 348 ₹696 | 355 ₹710 |
Tender Value
₹47.1 L
EMD Value
₹94,200
Closing Date
6 Mar 2026, 6:00 pmClosed
GE SILCHAR
Office of the GE Silchar Masimpur Cantt
SPECIAL REPAIRS TO BUILDING NOS T-51 OF SUPPLY POINT ASC LT UG CABLE AND CONNECTED WORK FOR SEC A AND REVENUE WORK AT AIZAWL UNDER GE SILCHAR
2026_MES_752357_1
8104A/E8
Open Tender
Civil Works
Item Rate
180 days
Aizawl
Class D Category a i and other criteria as per NIT and Tender Doc
8 documents required · 8 mandatory
₹500
GE Silchar
₹94,200
Yes
23 Apr 2026
12 Feb 2026
9 Mar 2026
12 Feb 2026
6 Mar 2026
27 Feb 2026
12 Feb 2026 - 20 Feb 2026
B & R Division Items
Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed.
Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified.
Taking down Chowkats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified.
Taking down existing bitumen felt mastic flooring including cement mortar bedding and cleaning the surface, and removal outside MoD land, complete all as specified and directed.
Excavating in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loose type of soil complete all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as specified.
Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as specified.
Excavating in post holes each n exc 0.5 cum, getting out, in soft /loose soil, ramming earth filling or borken rubble mixed with earth around in layers nexc 25 cm watering and removing ssurfaces soil to distance nexc 50 m and making good surfaces all as specified and directed.
M&L for Hardcore broken stone of gauge n exc 63mm deposited spread and levelled in layers n exc 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:4:8), Type D2 using 40 mm graded stone aggregate as in foundations, sub-base,filling and mass concrete complete all as specified.
M&L for providing 100 mm thick plain cement concrete (1:4:8) type D-2 using (40mm graded stone aggregate) as in Sub base of floor rough surface complete all as specified.
M&L for plain cement concrete 1:3:6 type C2 (40mm graded aggregates) in foundation filling and mass concrete complete all as specified & as directed .
M&L for providing 75 mm thick plain cement concrete (1:3:6) type C-2 using (40mm graded stone aggregate) as in Sub base of floor, flooring, pavings ad similar work complete all as specified.
M & L for 75mm thick plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid in panels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed.
M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in bed blocks, coping , cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed.
M&L for PCC type B-2 1:2:4 (Using 40mm graded aggregate) as in surface channel and drain complete all as specified & directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends for etc complete all as specified and directed.
Material & labour for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. completed all as spd and directed.
M&L for 50mm thick PCC type B-1 1:2:4 (Using 20mm graded aggregate) complete all as specified & directed.
M & L for providing and laying 25mm thick mastic flooring conforming to IS 1195-1978 on concrete surfcae incl hacking & cleaning the surface.The propotion of mixing of bitumen ,lime stone powder,coarse & fine aggregate ,bitumen IS 702(85/25)(15%),Coarse aggregate (15%),Fine aggregate (60%)& lime powder (10%)shall confirm to IS 1195-96with all necessary equipment all as specfied and as directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B-0, (Using 12.50 mm graded agg.) as in floors all as specified and directed.
Material and labour for precast autoclaved acrated concrete bricks (AAC) block masonary with 150mm thick with grade -I, AAC block of density 551 to 650kg/cum conformimg to IS-2185 (Part -III) i super structure above plinth level upto floor V level with RCC bend at sill level and lintel level with approved block laying polymer modified adhesive mortar complete all as spd and directed. Note : RCC bend and reinforcement shall be measured and paid separately
Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed.
Use and waste formwork to sides and soffits of floor or roof beam, beam hunching, girder, lintels, cantilever, shelves including supports etc for rough finished flat surfaces of concrete complete all as specified and directed
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete all as specified and directed.
Material and labour formwork to,rough finished surfaces of flat concrete, chullah hoods, chajjas,troughs and similar items including edges,etc complete all as spd and directed.
Material and labour for providing Reinforced Cement Concrete (Nominal mix) (1:1.5:3) type A1 using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc all as specified and directed.
Material and labour for providing Reinforced Cement Concrete (Nominal Mix) 1:1.5:3 type A1 using 20 mm graded aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
Material and labour for providing Reinforced Cement Concrete (Nominal Mix) 1:1.5:3 type A1 using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5 m complete all as specified and directed.
Material and labour for providing Reinforced Cement Concrete (Nominal Mix) 1:1.5:3 type A1 using 20mm aggregate as in slab supported on walls , beams, and column in floors, roof, landing, balconies, canopies, deck slab and in shelves and like etc comlpete all as specified and directed.
Material and labour for providing Reinforced Cement Concrete (1:1.5:3) type A1 using 20 mm graded aggregate as in Chajjas etc all as specified and directed.
M & L for 10mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L for 6mm to 8mm dia and over TMT bars, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M & L for Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed
M & L for brickwork with subclass 'B' or locally available best quality old size bricks, straight or curved on plan exc 6 m mean raduis, built in CM (1:6) complete all as specified and directed.
M & L for half brick work in cement mortar (1:4) straight or curved on plan to any radius with locally available Subclass ‘B’ old size best quality bricks all as specified .
Material and labour for 12 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair complete all as specified.
Material and labour for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair complete all as specified.
Material and labour for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using of extra cement complete all as specified. Note:- WPC shall be measured and paid separately.
Material and labour for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair with using of WPC complete all as specified. Note:- WPC shall be measured and paid separately.
Supplied only integral waterproofing compound etc complete all as spd and directed.
M & L Non Skid ceramic tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry as specified
M & L Glazed ceramic coloured tiles in vertical surface size 450mm x 350mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed.
Material and labour for chequered cement concrete tiles 250mm x 250mm x 22mm thick,set, jointed and pointed in neat cement slurry in floors, with mixture of grey and white cement in equal including 15mm thick screed bed or bedding layers of cement mortar (1:6) complete all as specified & directed.
Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Supply and fix Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-240 complete all as specified and directed.
Supply and fix 5 mm thick mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe 290 grade E-165 complete all as specified.
Supply and fix mild steel screw bolts (machine made) of 11 mm to 15 mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt exceeding 10 cm but not exceeding 15 cm complete all as specified.
S/F bands, straps,clamps,cleats & small articles, supports or stays for rainwater,ventilating pipes, including bolts etc conforming to Fe-290 Gde-E-165 all as specified and directed.
S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 165x60mm for door and window frames with one or more rebates including hinges, lock strike plate, shock absorber, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, lugs as in hold fast with locking arrangements, complete all as specified.
S&F 2nd class hard wood glazed and skeleton door shutters 35 mm thick open rebated and prepared to receive glass, guage etc (withoput sash bars), edge of framing plain chemfered ro rounded fitted with cut and mitred beds for securing glass etc size of members of shutter as specified in SSR Part I section 8 clause 8.20(a) complete all as specified and directed.
S&F for 2nd class hardwood, 30mm thick, glazed and skeleton shutters, open rebated and prepared to received glass, guaze etc (with sash bars) edge of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc.
S & Fixed in repairs second class hardwood plain, solid, straight chowkats and frame, wrought framed rebated in the solid rounded or chamfered put togather with glass, pinned at joints all as speificed and replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store complete all as specified.
S & F 30 mm thick Second class Hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, complete all as specified.
S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified.
Supply and fix 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixedcomplete all as specified.
Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed .
Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix 200 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix eaves gutters 110 mm bore PVC (SWR) Pipe single socketed in any length with rubber ring joints, fixed in wall complete all as specified.
Material and labour for pre-painted designer false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600 mm x 600 mm with main runner 38 mm x 24 mm and wall angle 24 mm x 24 mm using 4 mm thick High Pressure Non Asbestos Fibre Cement prepainted decorative board (E-Board Classic) in a grid of GI system duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450 mm from the adjacent wall, Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610 mm c/c,so as to form 600 mm x 600 mm grid and painted with two coats of acrylic emulsion paint of approved shed /make over a coat of cement primer before installing it on the grid complete all as specified . Make: Everest Industries Ltd or equivalent as per IS 14862.
M & L for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed.
Material and labour for applying two coats of cement base paint over one coat of primer on plastered surfaces of walls including preparation of new or previously untreated surfaces all as specified and directed
Material and labour for preparation of new wall surfaces and applying two coats of oil bound distemper (white or tinted) over a coat of 1 mm thick wall putty over a coat of alkali resistance primer complete all as specified.
M & L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Prepartation of old painted steel surfaces over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying two coat of Synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
E & M Division items
Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed.
M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover suitable for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch.
M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One ceiling fan point controlled by one, one way switch 5 Amp.
M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One exhaust fan point controlled by one, one way switch 5 Amp.
M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit concealed of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board.
M&L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit concealed type of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board.
M&L for point wiring with FRLSH stranded copper conductor 4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit concealed type of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings.
S&F modular switch 1 way 6A/10A, 1 Module complete all as specified and directed.
S&F modular switch 1 way 16A/20A, 1 Module complete all as specified and directed.
S&F modular socket 6A/10A, 2/3 pin combined 2 module complete all as specified and directed.
S&F modular socket 16A/20A, 2/3 pin combined 2 module complete all as specified and directed.
S&F ceiling rose surface bakelite with three terminals all as specified and directed
S&F electronic fan regulator modular type stepped type (5 steps) 120W, 230V, 2 module, ISI marked duly connected up complete all as specified and directed
S&F modular metal flush box 3 module with white cover plate with frame ISI marked complete all as specified and directed
S&F modular metal flush box 6 module with white cover plate with frame ISI marked complete all as specified and directed
M&L for submain wiring with two single core 10.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid Conduit concealed with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 6.0 sqmm PVC insulated FRLSH unsheathed multi strand copper conductor earth wire connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing incl taking out old existing submain wiring complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length.
Supply & Fix LED betten plastic type fitting of capacity 20W, operating on 230V, 50Hz, AC Supply having luminous efficacy of not less than 125 lumens/watts, CCT 6500K, P.F>0.9, 2.5 KV surge protection, 4-feet long, housing made out of extruded alluminium with decorative end caps elegently designed complete all as specified.
Supply & Fix enviromental friendly bldg security street light, LED luminaire 25 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr-in–charge.
S&F plastic body exhaust fan 300 mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and as directed.
S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook complete all as specified and directed.
S&F sheet metal enclosure powder coated three phase and neutral DB for fixing of MCBs, 4 way double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
S&F MCB TPN of capacity 63 Amps , 240 V, 10 KA 'B' curve complete all as specified and directed.
S&F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed.
Supply & fix earth continuity conductor or main earthling lead fixed to wall on battenor recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required copper earth strip 20mm x 3 mm with saddles/ fasteners/ insulators and fixing screws etc including taking down old one complete as specified and directed.
material & labour in replacement of test terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 nose 8mm die 25mm long hexagonal lead screws including taking down old one complete all as directed.
Meterial & labour 40mm bore galvanised steel tubing light grade fixed on the top of the roof with socked/clamps or by welding etc for fixing single point air termination rod for lightening conductor support as required at site including taking out of the existing old rusted pipe complete as specified and directed.
Supply & fix in replacement of air termination single pointed aluminium rod 12mm dia 300mm long for lightning protection complete as specified and directed.
Supplying laying jointing and teting GI tubes 80mm bore light grade with all fittings and fixed to walls or laid under road for passing cables or used as pole for installation of LED post top lantern complete including dismantling old one complete all as specified and directed.
Supplying laying jointing and teting GI tubes 50mm bore light grade with all fittings and fixed to walls or laid under road for passing cables or used as pole for installation of LED post top lantern complete of size 50mm including dismantling old one complete all as specified and directed.
Supplying laying jointing and teting GI tubes 40mm bore light grade with all fittings and fixed to walls or laid under road for passing cables or used as pole for installation of LED post top lantern complete of size 40mm including dismantling old one complete all as specified and directed.
Supplying laying jointing and teting GI tubes 25mm bore light grade with all fittings and fixed to walls or laid under road for passing cables or used as pole for installation of LED post top lantern complete including dismantling old one complete all as specified and directed.
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 10 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 10 sqmm 2.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 25 sqmm 4.0 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 35.0 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 50 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 70 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 95 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors conforming to IS-7098 (ParI)-1988, 1100 volts, grade cross sectional area 120 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. Note :-(Excavation and earth work, bricks, sad cushioning and GI Pipe will be measured and paid separately under respective items)
S & F in repairs MCCB 4 pole 25 KA 100 amps 415 Volts 50 Hz with thermal magnetic release setting fixed to panel board with necessary arrangment including nuts bolt lugs etc complete all as specified and directed.
S & F in repairs MCCB 4 pole 16 KA 63 amps 415 Volts 50 Hz with thermal magnetic release setting fixed to panel board with necessary arrangment including nuts bolt lugs etc complete all as specified and directed.
Material and labour as in replacement for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25mmx4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Taking out old existing earthing and M & L for new earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed.
Taking out old existing earthing and M & L for new earthing with copper earth plate of size 600mm x 600mm x 3.15 mm thick buried directly in ground not less than 2.25 metre below ground level earth plate paced on all side with charcoal mixed with salt to a thickness of 150mm in layers, connected by copper strip of size 20mm x 3 mm thick, soldered and riveted to earth plate copper earth strip will be protected by using 40mm bore GI pipe ( light grade). The earthing includes PCC pit chamber, RCC pit cover and frame , watering pipe 20 mm bore, funnel with wire mess with necessary earth work including disposal of of surplus soil to a distance not less than 50 metre complete all as specified and shown in electrical plate No 3 of SSR Part I -2009 complete as specified and directed.. Note- Main earthing lead form earth plate to test point & up to 7.5 metre to be provided. The cost for the same shall be deemed to be included in the above quoted rate
M & L plain cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as used for foundation of errection of pole, filling in repair of road cuttings etc complete all as specified and directed.
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge. Note : Thickness of sand cushioning after punning down will be measured.
M&L for bricks sub-class 'B' laid in trenches in flat style (width portion in horizontal shape) for cable protection complete all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.15 MB
8104A-TP.pdf
Tender Documents • 0.51 MB
BOQ_842674.xls
BOQ • 0.43 MB
8104A-SchOfCreditformat.pdf
Additional Documents • 0.04 MB
Amdt-TP.pdf
PDF • 0.55 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .