| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.3 CrAccepted-AOC NEW NO H 98 1 PERIYAR NAGAR ERODE 638 001 | ERODE | TAMIL NADU | 638001 | ₹17.3 Cr Quoted ₹18.7 Cr | 1 | Accepted-AOC 1st Lowest bidder |
| 2 | 2₹19.4 CrRejected-AOC R MUTHUSAMY BROTHERS INDUSTRIAL COMPLEX T S NO 6 2 PALLADAM ROAD TIRUPPUR 641 604 | TIRUPPUR | TIRUPPUR | TAMIL NADU | 641604 | ₹19.4 Cr | 2 | Rejected-AOC 2nd Lowest bidder |
| 3 | Rejected-Technical SAKTHI MAHAL NO 63 PERUNDURAI ROAD ERODE 638 011 | ERODE | TAMIL NADU | 638011 | - | - | Rejected-Technical NOT ACCEPTED |
Tender Value
₹17.2 Cr
EMD Value
₹8.7 L
Closing Date
18 Jan 2024, 3:00 pmClosed
Superintending Engineer
Office of the Superintending Engineer PWD Buildings C and M Circle Madurai
Providing Compound wall, Additional ground level seating gallery, Sthapathy works, Museum, Canal, Canal Cleaning work, Internal and Externals lightings to Jallikattu arena at Keelakarai village in Madurai District
2024_PWD_408374_2
17/2023-2024
Open Tender
Civil Works - Buildings
90 days
Keelakarai village in Madurai District
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8.7 L
5 Mar 2024
11 Jan 2024
19 Jan 2024
11 Jan 2024
18 Jan 2024
11 Jan 2024
Amount
Clearing light jungle etc.
Earthwork Excavation for foundation to full depth in all soils and sub soils to full depth as may be directed except in rock requiring blasting but inclusive of shoring strutting and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15 cm thick well rammed and consolidated depositing the surplus earth within the compound in places shown by the Executive Engineer with initial lead and lift and leveling the same etc., complete complying with standard specification drawings.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling Gravel in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five M- sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick, well rammed, consolidated and curing etc. complete complying with standard specification
Supplying and erecting steel shuttering including necessary supports for plane surfaces in foundation and basement for reinforced cement concrete works such as column footing, plinth beam, grade beam, stair case step, bed block etc. which require only normal strutting using M.S. sheets of size 90cm x60cm BG 10 gauge of stiffened and welded with mild steel angles etc. complying with standard specification. (The payment for centering shall be made only after the concrete is laid).
Supplying and erecting, centering for sides and soffits including supports and strutting upto 3.29m height for plane surfaces as detailed below in all floors with all cross bracings using mild steel sheet etc. complete
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc
Plane surface such as RCC square or rectangular column, top and bottom slab of sunshade, boxing sill slab etc.,
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
Brick work in following Cement Mortar 1:6( One cement and six M-sand) using best quality Fly Ash Bricks 230 x 110 x 75mm including finishing, curing, etc., complete complying with standard specifiction.
For Foundation and Basement
For Superstructure in Ground floor
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and filling in foundation, basement, etc with filling stone dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Providing and laying in position, standardised concrete Mix M-20 Grade in accordance using 20mm with IS:456-2000, and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cum') 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation & Basement
For Superstructure Ground floor
Supplying, fabricating and placing in position M.S. or R.T.S. reinforcements grill for RCC works as per the design given including cost of steel and black binding wire etc., complete complying with standard specification
Plastering with Cement Mortar 1:5 (One cement and Five P- sand), 12 mm thick in all floors including finishing neatly curing etc. complete complying with standard specification.
Paving the floor with best quality matt finish vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M- sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works
Paving the floor with best approved quality Leather polished Granite Stone Slabs 1200mm x 600mm, 16mm to 18mm Thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M-sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification
Ornamental Border work 4" width and Double Coping with Cement Mortar 1:5 (One cement and Five P-sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with ready mixed plastic Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting New iron work for doors, windows and ventilators using iron bars, window, grills weld mesh screen in open courtyard entrance gate etc., with two coats synthetic enamel paint of approved quality and colour over the existing priming coat in all floors. The rate is inclusive and scaffolding charges etc., complete complying with standard specifications.
Supply of (1200mm dia) NP3 class RCC pipe conformed to IS 458/2003 including cost of pipe as a finished work including all other incidental charges including loading unloading,transport and delivery in good condition at work site etc. as directed by the departmental officers,as per standard specfications.
Rough stone dry packing for side revetment using new rough stone for apron and revetment including stacking the rough stone for premeasurement,cost of new stones,wedges for filling the gaps,finishing neatly etc.complete complying with std specification and as directed by departmental officers.
Supply and fixing ofChain link fencing - 2" x 2" using 10 Gauge Galvanised Iron Wire (of all sizes) and as directed by the departmental officals.
Pointing to random rubble masonry with cement mortar 1:4 ( one cement and four M sand ) complete complying with standard specification.
Columns sthapathy Work: Providing sthapathy work for following size of concrete column, brick pillar, border works Upanan, kambu patham, kandam, kabokatham, sthapathy work, oppapida sthapathy work cost of materials including scafolding charges, centering, decentering, labour charges cleaning debris that retrained after works transportation as applicable and all other incidental charges and as directed by the departmental officers.
Column 750mm Dia x 6.00 mtr height
Column 330mm Dia x 3.00 mtr height
Column 900 x 900 mm-10 ft
Brick pillar 600mm Wide x 11.5m Height
Column 450 x 450 mm - 8ft height
Brick pillar 600mm Wide x 7.20 m Height
Sthapathy Doom Work: Providing following size of dome over the concrete column and slab which is made of cement concrete M 25 and covered with Autoclaver Aerater Concrete block works in cement mortar 1:3 to approved height as per drawing dome covered in sthapathy design such as Upanan, patham kambu, kandam kambu, elthakam, melapadam, vedikai kambu etc the rate is including cost of all materials plastering sthapathy work, border work, centering, decenterling work, labour charges, cleaning debris that retrained after works transportation as applicable and all other incidental charges and as directed by the departmental officers.
Providing border sthapathy works arranged at parapet wall, outer wall, sunshade, windows, doors etc., as directed by the departmental officers the rate includes providing architectural design in border cost of all material sthapathy work, border work, centering, decenterling work, labour charges, cleaning debris that retrained after works transportation as applicable and all other incidental charges and as directed by the departmental officers.
Roof border
Koduvai border
Heavy work window border (for large size)
Heavy work window border (for small size)
Window border
Border for door opening
Facia border
Box type facia border (0.45 x 0.60m)
Box type border (1.80 x 1.20m)
Supplying and fixing Ornamental jally work with size of 600mm x 600mm including cost of mould, finshing, curing, lifiting, transport charge, labour & finishing position charge etc.complete complying with standard specification.
Supplying and Fixing of Wood, Plastic, Composed board Louvers 100mm x 50mmx 3mm thick including labour charges and as directed by departmental officals
Providing granular sub-base - III Plant mix by close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 250 mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
Providing and laying Prime Coat over WBM/WMM surface using 7Kg of Bitumen Emulsion (SS1) per 10 sqm for preparatory to another bituminous construction over it including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per Clause 502 of MORTH Rev-5
Providing and laying Tack Coat over WBM/WMM surface (treated with primer) using 2.50Kg of Bitumen Emulsion (RS1) per 10 sqm for preparatory to another bituminous construction over it including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per Clause 503 of MORTH Rev-5
Providing and laying 50mm consolidated thick bituminous macadam using 0.20 cum fo 26.50-13.20mm, 0.43 cum of 13.20-2.36mm and 0.08 cum of 2.36mm & below size IRC metal with 37 Kgs of VG30/ VG40 bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory / Pneumatic Roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher / 9m paver finisher, Vibratory / Pneumatic roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 504 of MORTH Rev-5
Providing and laying Bituminous Concrete to 40 mm thick using 0.13 cum of 19.00-9.50mm, 0.17 cum of 9.50-2.36mm and 0.26 cum of 2.36 and below with 50.30 kgs of VG30/ VG40 bitumen for premixing per 10sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 40mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory / Pneumatic Roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher / 9m paver finisher, Vibratory / Pneumatic roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
Supplying and fixing of Pvc Pipe of 75mm dia having working pressure of 4 kg /sq.cm as directed by departmental officals.
Supplying, spreading and mixing red earth, sand and farm yard manure for plantation etc.complete complying with standard specification.
Making of lawn with germen grass truffing including forking the ground top, dressing with sludge manure of fertilizers etc., and as directed by the departmental officals.
Supplying and planting Border Plants inclduing digging holes in earth, refilling the same with manure, working etc.and as directed by the departmental officals.
Fundamass
Alumendass
Singapore Expora
Mini Ehora
Mini Nanthiya Vattaiya
Supplying and planting For Trees inclduing digging holes in earth, refilling the same with manure, working etc.and as directed by the departmental officals.
Earthwork excavation in all classes of soil except soft disintegrated rock not requiring blasting and hardrock requiring blasting and depositing on bank with all leads and lifts as per SS20B, including cost of all labour, equipments and all incidential charges such as baling our water, providing and maintaining necessary cofferdams, sheeting, shoring bracing and their subsequent removal, removal of all logs, stumps, grubs and other deleterious matter and obstructions, trimming bottom of excavation backfilling, and clearing the site and disposal of all surplus materials etc., complete as per relevant standard specification for FOUNDATION OF ABUTMENTS, PIERS & RETURN WALL. as per section 300 of MORT&H Specifications (Fifth Revision -2013
Depth 0m to 2m
Depth 2m to 3m
Depth 3m to 4m
Filling behind Abutments and return wall with clean gritty gravel including cost and conveyance of gravel to worksite, laying, handling charges and filling in layers, tamping under optimum moisture content to get the maximum density including watering, with all leads for water and all other incidental charges etc., complete. as per CI.710.1.4 & Appendix 6 of IRC :78-2014
Plain Cement Concrete of grade M15 Nominal Mix using 40mm ISS size HBG graded metal including cost and conveyance of all materials to site including cost of cement at site including cost of formwork, soft water, labour charges for mixing, transporting, laying and curing concrete , working at depths , tools and plants and including all other incidental charges etc; complete as per relevant standard specifications, for LEVELLING COURSE.Under footing as per 2100 of MORT&H Specficaton (Fifth Revision-2013)
Vibrated Cement Concrete of grade M20 Nominal Mix using 40mm ISS size HBG graded metal including cost and conveyance of all materials to site including cost of cement at site including cost of formwork, soft water, labour charges for mixing, transporting, laying and curing concrete , working at depths , tools and plants and including all other incidental charges etc; complete as per relevant standard specifications, for SUBSTRUCTURE OF ABUTMENTS, RETURN WALL AND PIERS BELOW SILL LEVEL. as per Section 1500,1700 & 2200 of MORT&H Specficaton (Fifth Revision-2013)
Vibrated Cement Concrete of grade M20 Nominal Mix using 40mm ISS size HBG graded metal including cost and conveyance of all materials to site including cost of cement at site including cost of formwork, soft water, labour charges for mixing, transporting, laying and curing concrete , working at depths , tools and plants and including all other incidental charges etc; complete as per relevant standard specifications, for SUBSTRUCTURE OF ABUTMENTS, RETURN WALL AND PIERS ABOVE SILL LEVEL. as per Section 1500,1700 & 2200 of MORT&H Specficaton (Fifth Revision-2013)
Vibrated Reinforced Cement Concrete of grade M30 design mix using 20mm ISS size HBG graded metal including cost and conveyance of all materials to site including cost of cement at site including cost of formwork, soft water, labour charges for mixing, transporting, laying and curing concrete , working at depths , tools and plants including all other incidental charges etc; complete as per relevant standard specifications, for DIRT WALL CUM BED BLOCK OVER ABUTMENTS AND BED BLOCK OVER PIERS.as per Section 1500,1700 & 2200 of MORT&H Specficaton (Fifth Revision-2013)
Vibrated Reinforced Cement Concrete of grade M30 design mix using ISS size HBG graded metal including cost and conveyance of all materials to site including cost of cement at site including cost of formwork, soft water, labour charges for mixing, transporting, laying and curing concrete , working at depths , tools and plants including all other incidental charges etc; complete as per relevant standard specifications, for deck slab and safty kerb as per Section 1500,1700 & 2200 of MORT&H Specficaton (Fifth Revision-2013)
Supply and fabrication of Fe-500 steel required for all RCC items of works involved in the schedule, including cost of steel at site and cost of fabrication labour charges for cleaning the rods straightening,cutting,bending,tying grills, including over laping to the required length wherever necessary and providing to the reinforcement placing the reinforcement in position as specified in the drawings including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges , etc., complete. as per Section 2706 of MORT&H Specficaton (Fifth Revision-2013)
Supplying and fixing Teakwood Entrance Door with a size 5.40m x 2.60 m with four leaves as per the design approved by the departmental officers. The outer frames are one horizontal and three verticals of size 150x100mm scantlings. Shutter frames are 100x50mm scantlings. The shutter shall have 2.40m hight with two panels having 1/3 at bottom and 2/3 at top. The panels shall be 40mm thick Teakwood planks. The shutter shall have 4 leaves of equal size and openable. etc., complete complying with standard specification.
Supplying and fixing Solid core Particle board flush shutter of nominal thick of 35 mm with Teak ply on both sides and with T.W. lipping alround conforming to IS 2302 including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200 x 12 mm aluminium tower bolt 2 nos. 150x12 mm aluminium tower bolts 1no. 250 x 16 mm aluminium aldrops, 2 nos.200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. (Single leaf)
Supplying and fixing Solid core Particle board flush shutter of nominal thick of 35 mm with Teak ply on both sides and with T.W. lipping alround conforming to IS 2302 including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200 x 12 mm aluminium tower bolt 2 nos. 150x12 mm aluminium tower bolts 1no. 250 x 16 mm aluminium aldrops, 2 nos.200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. (Double leaves)
Supplying and fixing of Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc.,
Providing and fixing Acoustic Wall Panelling (equivalent to Armstrong) in channelled wood works perforated panels of width 192mm, thickness of 15mm and length of 2400mm or as per required by the Departmental Engineer made of a high density fibre board with minimum 725 kg./m3 density substrate with a laminated facing as per the approved shade and finish and a melamine balancing layer on the reverse side. The boards shall have a special peforation pattern where the visible surface has a "Helmholtz" fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be "tongue-and-grooved" to receive special clips for installation. The back of the perforated panel shall have sound absorbing non woven acoustical fleese having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips provided by Armstrong and approved by the Engineer-in-Charge.
Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the water proof ply wood 19mm thick board over the country wood planks. with necessary screws and fevicol giviing neat finish. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmental Officers. The water proof ply wood and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.
Supplying and fixing the Wall Panelling with the following specification fixing horizontally and vertically in position of wall. Fixing the WPC 10MM thick board . with necessary screws and fevicol giviing neat finish. The surface will be finished with necessary design as directed by the Departmental Officers. The rate inclusive of all materials, labour power and conveyance of materials to the work site, loading & unloading etc., and as per drawing and design by the Departmental Officers.
Supplying, Fabricating, erecting and fixing Hilux (or) equivalent Board FALSE CELING upto a ceiling height of 4.50 m from floor level using Hilux board Perforated sheet 10mm thick.
Supplying and fixing 8mm thick Calcium Silicate Board Designed and Perforated for False Ceiling etc. and as directed by the departmental officals.
Supplying, Fabricating, erecting and fixing VOX FALSE CELING upto a ceiling height of 4.50 m from floor level, in the design pattern as directed by the departmental officers.
Providing Cornice Work for Gyp Board False Ceiling etc. and as directed by the departmental officals.
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work).
Providing Ornamental decorative Art paint works in wall surface with two coats of best approved first quality of following paint over the priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Ultima Painting
Acralic Painting
Supplying & Fixing Antique finish photo frame including approved Photos. The rate is inclusive of laying, conveyane, all other Tools and Plants involved in the work charges and all other incidental charges etc.,complete complying with standard specfication and as directed by the departmental officer. The materials quality,brand, colour, shade should be approved approved by the Executive Engineer before use on works).
Sun Board
Fibre Rock Arts
Flex Arts
Foam Sheet Details
Canvas Art
Artificial Grass
Manufacturing and supplying of Book Racks - 6 Level 1200W x 600D x 2350H: 1. Double Body with following sizes. 2. Body:- Side panels, Frame & Cross L bracket are made using 0.8 mm CRCA (IS:513). The assembly consists of 2 tie rods, 4 fixing brackets and 2 turnbuckles in each body. The tie rods are fixed in a shape of 'X' The tie rods are made of 4mm diameter rods of MS while fixing brackets are made of 2mm thick CRCA IS:513 Grade. 3. Under structure is made of 0.8m CRCA (IS:513). 4. Shelves:- Shelves used are 10 bend panel made of 0.8mm CRCA (IS:513). Shelf panels are placed on shelf support and then fixed using bolt and nuts from below. Standard configuration. consists of 6 loading levels formed by 5 no of adjusted shelf for each main and add on unit uniformly Distributed Load Capacity per each shelf is 80 Kg maximum. 5. Finish:- All MS sheet metal and metal frame components are powder coated with epoxy polyester powder to the minimum thickness of 45 microns. 6. Stackability: The add-on units can be stacked width wise to form a bank of racks having common side panel up to 4800W. 7. Shelf Back Stiffener:- At the rear side of the shelves back stiffeners are provided. These act as separators between front & rear books made of 0.8mm Thick CRCA (IS:513). 8. Label Holder:- It is an aluminium extrusion of length 596mm for double body bookrack, fitted on to front of body. The Paper is 300GSM matt finish, to be inserted into the aluminium extrusion. The length of paper is 596mm for double body bookrack. In Addition necessary suitable bushes should be provided as per requirement. The shape, colour, shade and size are as per design as instructed by the departmental officers concern. The rate includes cost of all materials, fabrication, transports and other incidental charges, including fixing in position and excluding GST etc., complete
Manufacturing and supplying of furniture Conference Hall: 1. SEAT REST ASSEMBLY: The seat rest assembly is 1.5±0.1 cm thick. flat plywood measured as per QA method described in OCP-QLTA-P14-18 and in-situ moulded with polyurethane foam & upholstered with polyester fabric and enclosed by an injection moulded cover. The Seat has an auto-tip up feature making it stay in upright position when not in use enabling clear row passage. The seat profile has a large waterfall edge to help the users get necessary comfort in popliteal region. Seat size: 45.0 cm. (W) x 50.5 cm (D) x 13.8 cm (T) Approx..2. BACKREST ASSEMBLY: The backrest assembly is made up of 1.2±0.1cm thick flat plywood measured as per QA method described in OCP-QLTA- P14-18 upholstered with polyester fabric and enclosed by an injection moulded back cover. The back foam is designed with contoured back support for extra comfort. High back size: 48.7 cm. (W) x 76.9 cm (H) x 12.5 cm (T) Approx.3. HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam for Seat and Back is moulded with Density = 45 +/- 2kgs/m³ 4. LEG FRAME ASSEMBLY: The leg frame assembly is fabricated from M.S. tube 6.0±0.03cm x 4.0±0.03cm x 0.2±0.016cm thick welded with grouting member. It is black powder coated ( DFT 40-60 microns) & grouted to the floor using anchors.5. ARM REST ASSEMBLY: The arm rest is made up of black integral skin polyurethane with 65+/-10 Shore 'A' hardness and reinforced with M.S. insert fixed with leg frame. The arm rests are scratch and weather resistant. Te armrest is available in two options with and without cup holder. 6. ARM REST CLADDING: The armrest cladding is made up of 0.9±0.1 cm thick Plywood & upholstered with polyester fabric. The cladding is fixed to Aisle Side panel Only. All in between panels will not have armrest cladding
Supplying and fixing of Door Closer etc. complete and complying with standard specification.
Providing, Stitching & Fixing up of Window Curtain in required sizes in two layers consisting of Crush Cloth and Black out type cloth having the following specification: Crush Cloth: The Crush Cloth should be made of 100% Polyester fabric. It should be of design crush & size of 1.2 meter width and 1.30 height should have minimum weight of 1 kg. for 4.5 meter length. Black out Cloth: The Black out Cloth should be made of 100% Polyester fabric. If considered 1.2 meter width then it should have minimum weight of 1 kg. for 3.77 meter length. Complete job to be carried out as per the specification and direction of Engineer-incharge.
Supplying of Books -350nos including printing works, binding works, transportion complete and complying with standard specification.
Supplying and fixing of Toughened Glass Door using 12mm thick Glass panel with necessary fixtures and Hatching the glass partitons as directed by the departmental officers. The rate includes cost of Glass panel, fixtures, connecting clamps, breackets and hatching materials, conveyance charges, loading and unloading charges etc., complete.
Supplying and fixing of Toughened Glass Partition using 12mm thick Glass panel with necessary fixtures and Hatching the glass partitons as directed by the departmental officers. The rate includes cost of Glass panel, fixtures, connecting clamps, breackets and hatching materials, conveyance charges, loading and unloading charges etc., complete.
Supplying and fixing of Toughened Glass Partition with Teak wood Frame using 12mm thick Glass panel with necessary fixtures and Hatching the glass partitons as directed by the departmental officers. The rate includes cost of Glass panel, fixtures, connecting clamps, breackets and hatching materials, conveyance charges, loading and unloading charges etc., complete.
Supplying and Fixing of Murals Works.Including Moulding Charges, transportation, Loading and Unloading etc..,Complete as per Standard Specification and as directed by departmental officers
Copper Metal Finish 15.5' x 7.5'
Fibre Metal Finish 6' x 6'
Fibre Metal Finish 6' x 9'
Hero Stone Sculptures
Aeruthaluvuthal Sculpture
Recla Race - Bull cart
Bull Dance
Sindhu Samaveli Sculpture
Supplying and fixing in position of following decorative object etc., Complete as per Standard Specification and as directed by departmental officers
Fibre Bull
Bull with player
Bull Game Raid
Tamilnadu Map of size 0.90 x 1.80 mtr
Casting. Moulding, and fixing of Muthamizh Arignar Kalaignar Brass statue With Pedestal Perch type work of 5'5" crafted by skilled approved artisans. The statue should be moulded by using best quality brass and finished smooth. Necessary pivotal provisions are to be provided in the bottom of the statue to fix it over the peedam and also to have rigidity. The base provided with ornamental mural works consisting of architectural embellishments like, peetas, padmas, pillers, pilasters, bodhikas, kapotams, koodu, sikaram and other ornamental cornice works and also necessary creepers, murals and sculptures. The rate is inclusive of cost of all materials, Labour charge, conveyance of material to site, Tools and Plants, scaffolding charges involved in the works, Power consumption charges and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. Since this is special nature of work the required quantity of wastage also included in the rate. (The material naterial quality, brand, colour, shade and shape should be got approved by the Engineer in charge and competent authority before use on works). (Special Work
Supply & Fixing Steel roof Truss with Continuous sandwich PUF Continuous sandwich PUF panels 50mm thick either as single piece, prefabricated, modular, factory made units which consist of an insulating layer of rigid polyurethane foam between two layers of metal sheets, comprises of PUF bonded between two sheets of Pre-coated GI sheets of 0.5mm thick to produce straight-to-finish panels with all necessary fixtures to complete the work in all respect. The rate Is Inclusive of design, shop drawing preparation ,submission for approval etc., and also inclusive of any other incidental charges such as lifting using cranes, labour charges for erection, cost of all materials involved and as directed by the departmental officers
Supplying and fixing of Doughened Glass Partition using 20 mm thick Glass panel with necessary fixtures and Hatching the glass partitons as directed by the departmental officers. The rate includes cost of Glass panel, fixtures, connecting clamps, breackets and hatching materials, conveyance charges, loading and unloading charges etc., complete.
Paving the floor with best approved Panacherise Carpet Tiles of size 480 x 480 x 3mm with machine cut edges laid over a Adhesive bed of 2mm thick other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification
Supplying and Fixing Door Carving using 19mm thick plywood Covered OST sheet with alround teak wood ornamental beeding and melamine polishing.including labour charges,Transportation,Cutting Charges,Loading and unloading etc., complete as per standard specification and as directed by the deparment officers
Supplying and Fixing Teak wood ornamental Door Carving and Latex polishing.including labour charges,Transportation,Cutting Charges,Loading and unloading etc., complete as per standard specification and as directed by the deparment officers
Supplying and Fixing Teak wood melamine sheet and melamine polishing.including labour charges,Transportation,Cutting Charges,Loading and unloading etc.,complete as per standard specification and as directed by the deparment officers
Supply and fixing of 65 mm (21/2") GI pipe (Class 'B')of 6 mt. Length with suitable Single arm extended at a angle of 45 degree from the 6Mtr. pole upto 1mtr. of 25mm dia GI Pipe (Class 'B') duly welded with removable top bracket with 300mm x 300mm x 6 mm MS base plate duly welded at the bottom with concreting with construction of Masonary pedestal with SMC Junction box fire proof shock proof with suitable clamp of box size 275X150X100mm to house 6A SP MCB protection control at a height of 2mtrs. above ground level, with door and with lock and key arrangements and with supply and fixing of 1No. of 48W LED street light fitting Philips/Crompton/ Havells make luminaire in a
Supply and fixing of 2Nos of 200W LED Flood light Fitting (Crompton Pluto Neo / Eq) made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection of System efficacy ≥ 110/120 LPW, 10KV SPD mounted on the existing 6 mtrs height pole or wall with suitable SMC box and 1.5 sqmm (22/0.3) PVC unsheathed copper wire of 1100V grade with necessary connection complete.(DATA-2).
Design, supply, erection, testing and handing over of 16mtr High Mast structure (Philiphs/Bajaj/Eq) with continuously tapered hot dip galvanized steel polygonal sides sections with telescopic strip joints to a total height of 16 meters capable of sustaining the maximum wind pressure at the erection site with single flange base plate secured welded in the bottom of the base mast section with vertically movable hot dip galvanized lantern carriage and accessories such as electrical junction box brackets for providing 12Nos. of 400W flood light luminaries with control gear box complete head frame assembly, Pulley drive, stainless steel wire rope single/double drum self lubricating winch arrangement suitable for raising and lowering the luminaries carriage ring flexible multi core power cable and necessary high tensile hot dipped galvanized foundation, bolt & nuts along with washers and anchor plates and templates including supply and fixing the following accessories in the Mast.
(a) Design and casting of suitable foundation with 1:2:4 mix RCC concrete with 30 cm projection above the ground level with 1 meter width x 1 meter length and 2 meters depth with necessary galvanized foundation bolts nuts and washers and dump plate enclosing the bolts for the High Mast considering the safe soil bearing capacity at site - 1 set
(b) High powered power tool complete with hand held control panel and motor with push button type remote control switch suitable for 3 phase 415 V 50 Hz for raising and lowering of the lantern carriage complete to operate all fittings mounted in the base to couple with winch - 1 set
(c) Feeder pillar box comprising 0.90m x 0.45m x 1.20m floor Alu frame with 63A TPN main switch 1 No, 63A fuse unit 3 Nos, 63A power contactor with automatic timer arrangements & reversing starter for 3 phase motor-1Set.
(d) Neon aviation obstruction light (Bajaj BJAOL (2) / equivalent -1 No
e) 2 Nos of special GI earth electrodes with copper plate 300 x 300 x 3mm and copper flat (1" x ¼") interconnection as per ISS complete with earth connection -1 set.
(f) Hot dip galvanized lightening arrestor -1 No
(g) Flood light luminaries of specially heavy type water proof Dust proof integral luminaries fitting provided with 400 W LED Light fitting Crompton / Philips make or equivalent with 400W LED bulb with drives, Alglas coated reflectors, with cable connection etc., complete as per standard specification -12Nos (DATA-3).
Supply and fixing of 25 litres capacity 1000W automatic electric water heater with copper container with glass wool / Puf insulation with MS powder coated shell (VENUS/RACOLD) with ISI mark suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing work. (DATA-12)
assembly, Pulley drive, stainless steel wire rope single/double drum self lubricating winch arrangement suitable for raising and lowering the luminaries carriage ring flexible multi core power cable and necessary high tensile hot dipped galvanized foundation, bolt & nuts along with washers and anchor plates and templates including supply and fixing the following accessories in the Mast.
(a) Design and casting of suitable foundation with 1:2:4 mix RCC concrete with 30 cm projection above the ground level with 1 meter width x 1 meter length and 2 meters depth with necessary galvanized foundation bolts nuts and washers and dump plate enclosing the bolts for the High Mast considering the safe soil bearing capacity at site - 1 set
(b) High powered power tool complete with hand held control panel and motor with push button type remote control switch suitable for 3 phase 415 V 50 Hz for raising and lowering of the lantern carriage complete to operate all fittings mounted in the base to couple with winch - 1 set
(c) Feeder pillar box comprising 0.90m x 0.45m x 1.20m floor Alu frame with 63A TPN main switch 1 No, 63A fuse unit 3 Nos, 63A power contactor with automatic timer arrangements & reversing starter for 3 phase motor-1Set.
(d) Neon aviation obstruction light (Bajaj BJAOL (2) / equivalent -1 No
e) 2 Nos of special GI earth electrodes with copper plate 300 x 300 x 3mm and copper flat (1" x ¼") interconnection as per ISS complete with earth connection -1 set.
(f) Hot dip galvanized lightening arrestor -1 No
(g) Flood light luminaries of specially heavy type water proof Dust proof integral luminaries fitting provided with 400 W LED Light fitting Crompton / Philips make or equivalent with 400W LED bulb with drives, Alglas coated reflectors, with cable connection etc., complete as per standard specification -12Nos (DATA-3).
Supply and fixing of 400A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double break on suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD-730).
Supply and fixing of 400 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only. (SD-742).
Supply and fixing of Vertical type 8 way triple pole neutral MCCB distribution board in sheet steel enclosure double door type with metal door with IP 43 - IK 09 protection with 160A 4 pole MCCB as incoming and 6Nos 63A TP MCB as outgoing and 2Nos 32A TP MCB as outgoing with suitable MS cable entry box on suitable angle iron frame on wall with earth connection only. (Higher End) (DATA-7)
Supply and fixing of Vertical type 8 way triple pole neutral MCB distribution board in sheet steel enclosure double door type with metal door with IP 42 protection with100A 4 pole MCB as incoming and 1No 63A TP MCB, 4Nos 32A TP MCB & 9Nos 6 to 32A SP MCB as outgoing as outgoing as outgoing with suitable MS cable entry box on suitable angle iron frame on wall with earth connection only. (Higher End) (DATA-8).
Supply and run of 5 core 4 Sq.mm multicore Industrial Copper Cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with painting of suitable colour (DATA-9).
Supply and run of 4 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 14 SWG TC wire with painting of suitable colour. (SD-62).
Supply and run of 5 core 6 Sq.mm multicore Industrial Copper Cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with painting of suitable colour (DATA-10).
Supply and fixing of SMC box of suitable size with 2/4 way connector with necessary connections complete. (DATA-11).
Supply, fabrication, erection and comissioning of 400A capacity dust and vermin proof cubical panel board size of 7' X 1' X 6' made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interior switch with bus bar chamber complete with
1" x 1/2" tinned cu. Flat for 3 phase, 1 " x 1/4" tinned cu flat for neutral, 1" x 1/8" tinned cu flat for earth connections with bus bar insulators. The following tinned Cu flat should be used for interconnection between busbar and switches: 1" x 1/2" tinned cu. Flat for interconnection of 1No 400A incoming switch to bus bar, 1" x 1/4" tinned cu. Flat for interconnection of 1No 250A Outgoing switch,1" x 1/4" tinned cu. Flat for interconnection of 4Nos 200A Outgoing switches to bus bar, 1" x 1/8" tinned cu. Flat for interconnection of 2Nos 125A Outgoing switches to bus bar and no.8 SWG copper conductor for interconnection of 2Nos 63A Outgoing switches to bus bar.
A separate chamber on top of one side should be provided with multi function meter to display Line & Phase Voltage, Phase Current, Power Factor and Frequency with one set of LED pilot lamp, fuse holder with suitable HRC fuse for each phase with suitable CT coil arrangements. The panel should be fabricated as per relevant IE rules & CEIG specification for accommodation of 10 Nos 3 phase switches and supply & fixing of the following switches.
1. 400 A TPN switch disconnector fuse units interior only with HRC fuses double break - 1No 2. 250A TPN switch disconnector fuse units interior only with HRC fuses double break - 1Nos 3. 200A TPN switch disconnector fuse units interior only with HRC fuses double break - 4Nos 4.125A TPN switch disconnector fuse units interior only with HRC fuses double break - 2Nos 5. 63A TPN switch disconnector fuse units interior only with HRC fuses double break - 2Nos
In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylum sheet separators, and properly earthed by tinned solid copper flat as I.E rules CEIG sepecifications.The earth bus with two runs of 1" x 1/8" tinned copper flat must be run all round the panel to provide double earth connection. The panel should be painted with two high quality enamel paint over one coat of red oxide primer, the cable size, capacity of switch, location etc., should be marked with white paint and 2 Nos. metallic danger board affixed complete with mounting on base channel 3"x1½"x½" iron frame work support complete. (The TPN switches should be L&T / Siemens make only) (DATA-22)
Supply and fixing of 3 Phase 400A aerial fuse unit for 3 Nos 400A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps (DATA-13)
Supply and fixing of brass cable gland for 3 1/2 x 70 sqmm PVC armoured LTUG cable with earth connection (SD-189).
Supply and fixing of brass cable gland for 3 1/2 x 120 sqmm PVC armoured LTUG cable with earth connection (SD-191).
Supply and fixing of brass cable gland for 3 1/2 x 240 sqmm PVC armoured LTUG cable with earth connection (SD-194).
Supply and laying of 3 1/2 x 70 sq.mm PVC armoured aluminium LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good (SD-207).
Supply and laying of 3 1/2 X 120 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good (SD-209).
Supply and laying of 31/2 X 240 Sq.mm PVC armoured aluminium LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good (SD-212).
Supply and clamping of 31/2 X 240 Sq.mm PVC armoured aluminium LTUG cable on post or on wall with MS Clamps (SD-230).
Supply and providing cable end termination of 31/2 X 240 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete (DATA-14).
Supply, Erection, Testing and Commissing of 1.5TR (4500K.cal/hr) ABS plastic split type inverter AC units with copper coil Conforming to IS.1391(part-2) with AMT 1 to 2 fitted with Rotary compressor operating on non-CFC refrigerant suitable for wall mounting expect power consumpition norms suitable for operation on 230V, 50Hz single phase AC supply with star rating of 5 as per BEE specification and capable of performing the funtions of
1) Cooling
2) Dehumidifying
3) Air circulating
4) Filtering
The installation work for the above split type AC units inculds the following
1. Mounting/fitting indoor and outdoor units at their respective locations.
2. Laying refrigerant pipe line of required length connection not exceeding 4 meters distance and both units after drilling hole/holes in the wall if required. Thickness of the copper tubing shall not be less than 0.8 mm.
3. Insulating the suction pipe with expanded polythylene foam 5 mm tubing.
4. Laying 25 mm dia flexible PVC drain pipe to throw out the condensate water being formed with in indoor unit.
5. Leakage testing the entire system gas in the unit.
6. Charging refrigerant gas in the unit.
7. Suitable electric wiring to be provided with 2.5 sq. mm PVC insulated copper wire between indoor units upto 6 mtrs length and up to switch with in 3 meters of the location of indoor unit (Carrier/Bluestar/O'General/Daikin) (SR).
Supply and Installation of 4 KVA Electronic Voltage stabilizer (V-guard make model ID4 Ace 5540) with input voltage range 140-280V and output voltage range 200-240V with high and low voltage cut of 3 min time delay relay with demonstration (SR)
Supply and Fixing of MS stand for fixing Outdoor unit (SR)
Supply and Laying of 5/8" and 3/8" copper pipe (Extra beyond 3 meters supplied with AC unit) (SR).
Supply and fixing of 1" PVC water drain pipe line on wall with suitable clamp and insullation as required (SR).
Supply of 1 No 250 KVA diesel generator set 0.8 P.F, 3 ph, 415v / 420 volts, 50 c/s, 1500 RPM as detailed below.
A. Engine: Water cooled diesel engine suitable for generator application with a shaft output of 310 BHP suitable at 1500 RPM under NTP conditions as per BS 5514-DIN-6271/IS 10002/ ISO - 3046 The engine shall comprise the following standard scope of supply : (Make Kirloskar Green/Eq)
1) Dry type Air cleaner. 2) Expansion bellow. 3) Radiator, radiator fan and mounting. 4) Air to air charge cooler.
5) Exhaust gas turbo charger. 6) Lube oil cooler and lube oil filter. 7) Fuel filter (pre and micro) 8) In-Line mono-block fuel injection pump with governor and fuel feed pump. 9) Electronic governor. 10) 24V battery charging alternator.
11) 24V Volt electric starter motor. 12) Engine test certificate. 13) Residential Muffler. 14) Fly wheel with Housing 15) Exhaust silencer.
Safety system of Engine: The engines shall trip for the following conditions with Visual alarm device. 1. Low lubricating oil pressure. 2. High water temperature. 3. Vee - belt failure and over speed.
The following visual indicator should also be provide Low Battery Indication.
The Engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load.
B. Alternator:
Alternator capacity of 250KVA/200KW, AC 3 phase, 50HZ, 415 Volts, 0.8 P.F, 4 wire self excited, self regulated designed to run at 1500 RPM under NTS conditions conforming to BSS 5000 / IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate. (Make : Kirloskar Green / Equivalent)
3) STANDARD CONTROL PANEL:
The Standard control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connecting incoming and outgoing leads having been made on the control panel.
1) Micro processor based integrated Generator controller unit : Kirlosker & Cummins Equivalent
2) DC Ammeter 0 - 10A (make : AE / Meco / IMP / Equivalent)
3) Stop push button, Red Mush room head (make : Teknix / Esbee / Kaycee / Equivalent) with 1 No + 1NC, 10A, 230V
4) Battery charger 24 DC, 10A (make : Cotmac / NHP / Equivalent)
Notes : This will be in addition to the battery charging alternator fitted to the Engine.
5) Indicating Lamp 2 Nos (Green) LED type, 24V DC for LOAD ON (make : Teknic / Esbee / Altos / Equivalent)
7) Toggle switch 6A - 2 Nos (Make : Kaycee, Salzer / Esbee / Equivalent)
8) Fuses with fuse link 2A, 4A & 10A - 10 Nos (make : Elmex / Phonix / Connect well / Equivalent)
9) Control Terminals 4.0 sqmm - 36 nos (make : Elmex / Phonix / Connect well / Equivalent)
10) No Elements 6A - 2 Nos (make : Teknic / Esbee / Equivalent)
11) Speed POT 5K, ohm 3W (make : Pankaj / Potel / Equivalent)
12) Plug in type relays with base 24v DC, 1 C/0 - 7 Nos (make : OEN / PLA / Equivalent)
13) Relays with Base 230 VAC, 5A (make : OEN / PLA / Equivalent)
14) MCB / Fuse 1 pole, 32A, B-curve, 10KA / 32A (make : Schneider / ABB / Legrand / Equivalent)
15) Hooter, Electronic Solid state 24V DC (make : Mimic / Acme / Hella / Equivalent)
16) ECD card ESD 5200 series / Equivalent (make : Kirlosker / Cummins / Equivalent)
17) Control cables 1.5 / 2.5 / 4.0 sqmm Cu. Mulltistranded - 1 set (make : Finolex / RR / Polycab / Equivalent)
18) GCU connectors 2 way, 4 way and 24 way with mate in lock - 1 set (make : Molex / Minifit / Equivalent)
19) Mating plugs - 1 set (make : AMP / TPK / TYCO / Equivalent)
20) Current transformer 400/5A, CL 1.5VA - 3 Nos (make : Kappa / AE / IMP / AMOL / Equivalent)
21) HRC fuse Base HB 800 and fuse link HN 400A - 6 Nos. (make : L&T / C&S / Siemens / ABB / Equivalent)
22) Power contractor 4P AC duty with wide band coil, 2 No + 2 NC auxillary contacts - 2 Nos. (make : L&T / C&S / GE / Schnieder / Equivalent)
23) Suitable BUSBARS - 1 set for 400A
Note : 1. The control panel should be complete with necessary fuses, cables, labels, other accessories with neutral isolation arrangements.
2. The engine should trip for the following conditions with Audio and Visual annunciation
a. Low lubricating Oil pressure b. High water / coolant temperature c. Engine over speed d. Low fuel level e. Engine under speed
f. Low water / coolant level in radiator g. Under voltage h. Over voltage i. Under frequency j. Over frequency
3. Audio and visual indication arrangements for : a. Low lubricating Oil pressure b. High water / coolant temperature c. High canopy temperature
d. Low Battery voltage e. Charging alternator failure f. Low fuel level
4. Two line display parameter for :
a. Engine status b. Engine oil pressure c. coolant temperature d. Canopy temperature e. Fuel level indication f. Battery voltage g. Battery cranking voltage h. Engine rpm. i. Main voltage (phase - Neutral, phase - phase) j. Main frequency
k. Main voltage (phase - Neutral, phase - phase
l. Generator current (Amps) m. Generator frequency n. Power factor o. KVA p. KVAR q. KWHr r. KW
5. The controller has data login facility for 50 faults recorded & option for RS232 / RS485 for remote monitoring / BMS Integration
d) ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC machines to maintain dimensional accuracy of hole within 0.1mm powder coating done after seven-tank surface preparation process of sheet metal.
Canopy panel and doors shall have inside lining of FIRE-RETARDANT 64kg/m density mineral wool of 100mm thickness as acoustic material. Four hinged doors shall be provided to canopy. The average sound level at 1 Mt. distance shall be less than 75DBA average or as per CPCB norms.
SURFACE TREATMENT - PAINTING
The enclosure shall be suitably treated for degreasing, de-rusting and posphating. The canopies are passed through seven-tank treatment thoroughly.
ADDITIONAL FEATURES OF CANOPIES
Canopy fabricated on CNC machines with dimensional accuracy of 0.1mm so as to increase its durability. Special designed supporting rips / structures are used in canopies so as to give studiness and to reduce the vibrations of the DG sets if any.
WORLD CLASS COOLING PACKAGE :
Canopies shall have cooling package for which it can also perform at 45 deg c / ambient temperature. No grounding required on the ground, only a level surface capable of with standing the DG weight. Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. The Gen set frame shall also be provided with hooks for unloading.
TEMPERATURE RISE INSIDE THE CANOPY :
Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well with in 5-7 deg centigrade.
e) BASE FRAME :
Base frame should be fabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure on it. The supply of Gen set includes loading, unloading and transportation charges.
f) FUEL TANK :
460 Lts. Integral Built in Fuel Tank shall be fabricated out of 14 SWG CRCA MS sheet and its part of base frame. It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. Supply of Diesel to run and test the generator at full load for 8 hours.
g) BATTERY :
2 Nos 12 V 180 AH battery.
h) Supply of maintenance manual books with engine and alternatore parts list.
i) Supply of tools required for the maintenance and operations of the Generator set.
J) Mounting of starting batteries of ½" thick hylem sheet base with suitable angle iron frame work support on the floor by the side of generator set to conform to latest CEIG conditions.
k) Supply and laying of annunciation cable of suitable capacity and length between engine and the control panel of the generator set (SR)
Supply and Installation of exhaust piping with suitable MS pipe to extend outside the Generator room with necessary thermal insulation (SR)
Supply, fixing, testing and commissioning of Samsung/ LG Make 98 inches Digital Signage (on wall with suitable wall mount accessories) with following specifications; 4K UHD 3840 x 2160 (16:9) Native Resolution, 450-500nits Brightness, 30,000-50,000 hours LED lifespan, 24/7 operation, Landscape & Portrait Display Orientation, Built-in speakers, Multiple connectivity options, ADA-compliant, TAA-compliant, Commercial grade 4K UHD LCD panels specifically designed for secure facility applications. [BIS, CE, FCC Certifications must] (MR)
Supply, fixing, testing and commissioning of P4 PRO OUTDOOR WALL DISPLAY of Screen Size – 6720 mm x 3840 mm (22ft x 12.6 ft) P4Pro LED Outdoor wall display with Screen Resolution i.e 1680 x 960 Design Latest Product with Specifications Pixel Density 62500 Pixels/m2 or more pixelpitch 4 mm to 4.8 mm as per brand pixel configuration SMD 3 in 1 LED Package LED Chipset Nation Star or Kin Light Weight per sqm, 25 -35 kg or less Unit case, 960x690 mm MS Cabinet. Optical Parameter Brightness 5000nit or more Brightness Uniformity 97% or more Contrast Ratio 6000 or more Viewing Angle – Horizontal 160 º or more Viewing Angle – Vertical 130ºor more Colour Temperature, 3,500- 9000 Bit Depth Minimum 14bit or more Power Consumption – Max 700 (W/m²) or less Refresh Rate 3,840HZ or more Operational Parameter Working Temperature20º C or less , 50ºC or more Working Humidity 10% RH 99% RHIP Rating Front IP65 IP Rating Back IP65 Led Lifetime 100,000 hours Global Certification CELVD UL/ETL IEC 60950/CB FCC EMC ROHS, LED Controller LED Controller to make Screen Working OEM. Including Pole type outdoor stand etc LED screen Make : Long Vision – Nation Star LEDModel: P4 PRO/ Eq.(MR)
Supply, fixing and configuration of Control system with following specifications; Synchronous display with control PC by DVI, 30-120 HzFrame update frequency, 1920-3840 Hz Screen Refresh Frequency, 16 bitsGamma Correction, Composite Video/ S- Video/ DVI/CATV Input supports,Control Distance @ UTP CAT5E 100m, @ Multimode Fiber 500m and @ Single Mode Fiber 10km, Dot by dot, Module by module, cabinet bycabinet Brightness Correction, operating temperature -10deg. to 40deg.celsius, operating humidity 10% to 80% RH. [BIS, CE, FCC Certifications must] (MR)
Supply, fixing, testing and commissioning of 3 phase15kVA Stabilizer with power rating 6kVA to 2000kVA Input voltage range 240V-480V, Nominal Voltage 400V, Output Voltage Accuracy + or - 1%, Line Frequency variation47Hz-53Hz, Digital/ Analog Control, response time 10ms Digital Display forDate & Time, Input Voltage, Output Volate and Current, Programmable features such as HV cut-off set.LV cut- ff. O/L trip set and time delay set, Aircooled for 5kVA to 1000kVA and above oil cooled. Automatic switch offagainst under/over voltage. Over-Load & Short- Circuit single phasing. Class C type secondary surge protection.(MR)
Supply, Installation, testing and Commissioning of 400 mm Dia Pole 15 feet Clearence 5” x 5" Sq Frame 3” x 3” Sq Pipe Support Frame2” x 2” Sq Side upport Frame4” x 2 Sq Led Support Frame Acp Sheet, RCC Concrete Foundation Rod 40mm” 5 feetFoundation Bolt – 5 MS Plate 2”x2” 25 mm. (MR)
Independent Inverter Large cassette Unit
Supply , installation , testing & commissioning of 4.0 TR cassette type inverter air-conditioning unit with indoor unit comprising of cooling coil, evaporator fan and motor controls, insulated drain pans enclosed in cabinet and 4.0TR outdoor unit complete with compressor, condenser fan & motor and enclosed in powder coated sheet metal cabinet unit suitable for operation on 415V +/-10%V, 50Hz, ac supply with microprocessor control including following accessories 1. filling of R410A refrigerant gas 2. 6core 1.5 sqmm control cable from indoor to outdoor unit. (Carrire / Blue star make / Eq)
VRF AC Arrangements
Supply of Blue Star make VRF-V Plus type Outdoor unit capable of delivering 100% capacity at 43 deg. C ambient temperature which is very unique to Blue Star VRF V Plus system. It can work non-stop even at 56 deg. C ambient temperature & Part load operation maximum efficiency.
Capable of working between 320V - 460V.
Temperature control with + 0.5°C or - 0.5°C accuracy to ensure uncompromised comfort Condenser coil made of helical inner-grooved copper tubes for maximum heat transfer efficiency.
Refrigerant-cooled heat sink ensures reliable operation even at ambient temperatures as high as 56°C.
with Special BLDC type fan motor of 30% more efficient than conventional motors and gives flexible capacity control with a unique fan speed control design logic Large sized accumulator, Economy mode and silent mode operations with 100% inverter Compressors
28HP VRF ODU (SR)
24HP VRF ODU (SR)
Supply of VRF Indoor units as specified.
Wall Mounted Split Indoor Units
2.0 TR Split Unit
Four way Large Cassette type Indoor Units
4.0 TR Fourway large Cassette type Unit
Supply of Refnet joints (SR)
REFRIGERANT PIPING :
41.3mm (Quotation)
SIVA ENGINEERING COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf