| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.7 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹20.0 L+₹30,319 (1.54%)Rejected-Finance | L-2 | Rejected-Finance High Rates | |
| 3 | L-3₹25.7 L+₹6.0 L (30.2%)Rejected-Finance | L-3 | Rejected-Finance High Rates | |
| 4 | L-4₹26.5 L+₹6.8 L (34.5%)Rejected-Finance | L-4 | Rejected-Finance High Rates |
| Sl No | Description | Qty | Unit | MODI CORPORATION L4 | M/s Pratik Enterprise L1 | SAHYOG ELECTRIC L3 | Vending Services And Solutions L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of AC any type, make, capacity through water jet pump with cover by approved agenecy by accepting officer, the minor defect/ complaints of any type and nature such as rectification of faulty electric circuit, tightening of loose wiring & connection of Air Conditioners of any type and any capacity incl servicing complete all as directed. | 113 | Each Job | 240 ₹27,120 | 250 ₹28,250 | 100 ₹11,300 | 85 ₹9,605 Lowest |
| 2.00Srl Item No 1.00 Note :- (a) All T & P and labour team required to attend the complaint comprising of adequate trained electricians & helpers will be provided by the contractor daily as directed. (b) Rep of the contractor will remain present in complaint cell & responsible for receiving & attending the complaints from 0800 Hrs to 1600 Hrs daily, the time of lodging the complaint. (c) Cost of minor stores such as screws, clamps, insulation tapes, rapping tapes,bracket of ACs, nuts/bolts, nails of required size etc shall be deemed included in the quoted rate. (d) Complaints where complete replacement of circuit/ point wiring is required shall be measured under relevent item of this schedule. | |||||||
| 3.00 | S&F in repair sealed compressor unit for any make and any type of Air Conditioner, window/Split type, 1.5 ton capacity, by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, and fixing of new sealed compressor unit by connecting suction and discharge lines with gas welding/ brazing work including checking the leakeage in the system and tightening foundation nuts & bolts etc complete all as directed.
Note : Gas charging will be measured and paid for separately in respective item of this schedule. | 32 | Each Job | 9,300 ₹2,97,600 | 7,000 ₹2,24,000 | 8,200 ₹2,62,400 | 4,600 ₹1,47,200 Lowest |
| 4.00 | All as per Srl item No. 3 here-in-before but for air conditioner split type, 2 ton capacity, complete all as specified and directed. | 28 | Each | 9,700 ₹2,71,600 | 8,000 ₹2,24,000 | 9,600 ₹2,68,800 | 6,400 ₹1,79,200 Lowest |
| 5.00 | Supply & fixing in replacement of PCB circuit with remote control of Window/ Split AC 1.5 ton capacity of any make as existing complete all as specified and directed. | 30 | Each | 1,180 ₹35,400 | 900 ₹27,000 | 1,200 ₹36,000 | 890 ₹26,700 Lowest |
| 6.00 | S&F of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 175V to250V and output voltage stabilized between 215V to 240V with accuracy of +/-2.5% and of capacity 4 KVA including dismantling of old one and deposited to MES Store yard complete all as specified and directed. | 12 | Each | 2,500 ₹30,000 | 4,500 ₹54,000 | 3,000 ₹36,000 | 2,440 ₹29,280 Lowest |
| 7.00 | All as per Srl item No. 6 above but capacity 5 KVA complete all as specified and directed. | 9 | Each | 2,700 ₹24,300 Lowest | 5,555 ₹49,995 | 3,300 ₹29,700 | 3,145 ₹28,305 |
| 8.00 | Supply & fixing in replacement of PCB circuit with remote control of Split AC 2 ton capacity of any make as existing complete all as specified and directed. | 9 | Each | 1,480 ₹13,320 | 600 ₹5,400 Lowest | 1,600 ₹14,400 | 1,190 ₹10,710 |
| 9.00 | S&F in replacement of electric Blower Motor capacity 1/8 HP, 1100 RPM, SP 230V, 50Hz for indoor unit of Split AC 1.5 ton capacity including testing complete all as specified and directed at site. | 10 | Each | 1,480 ₹14,800 | 2,600 ₹26,000 | 1,800 ₹18,000 | 790 ₹7,900 Lowest |
| 10.00 | S&F in replacement of electric Blower Motor capacity 1/13 or 1/10 HP, 1450 RPM, SP 230V, 50Hz for indoor unit Split AC 1.5 ton capacity including testing complete all as specified and directed at site. | 12 | Each | 1,480 ₹17,760 | 2,700 ₹32,400 | 2,000 ₹24,000 | 730 ₹8,760 Lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
2 Aug 2025, 6:00 pmClosed
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
REPAIR/ MAINTENANCE OF AC, DEEP FREEZER, WATER COOLER AND COOLING APPLIANCES AND MISC E/M INSTALLATION WORK OF DG SET, RENEWAL OF OLD EARTHING AND OTHER CONNECTED ITEMS UNDER GE (MCTE) MHOW
2025_MES_718562_1
GE(MCTE)/MHOW/20(T) OF 2025-26
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (MCTE) Mhow
As per Tender Document
10 documents required · 10 mandatory
₹500
Yes
GE (MCTE) Mhow
₹66,000
Yes
18 Sept 2025
5 Jul 2025
4 Aug 2025
5 Jul 2025
2 Aug 2025
19 Jul 2025
Amount
Comprehensive maintenance of AC any type, make, capacity through water jet pump with cover by approved agenecy by accepting officer, the minor defect/ complaints of any type and nature such as rectification of faulty electric circuit, tightening of loose wiring & connection of Air Conditioners of any type and any capacity incl servicing complete all as directed.
Srl Item No 1.00 Note :- (a) All T & P and labour team required to attend the complaint comprising of adequate trained electricians & helpers will be provided by the contractor daily as directed. (b) Rep of the contractor will remain present in complaint cell & responsible for receiving & attending the complaints from 0800 Hrs to 1600 Hrs daily, the time of lodging the complaint. (c) Cost of minor stores such as screws, clamps, insulation tapes, rapping tapes,bracket of ACs, nuts/bolts, nails of required size etc shall be deemed included in the quoted rate. (d) Complaints where complete replacement of circuit/ point wiring is required shall be measured under relevent item of this schedule.
S&F in repair sealed compressor unit for any make and any type of Air Conditioner, window/Split type, 1.5 ton capacity, by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, and fixing of new sealed compressor unit by connecting suction and discharge lines with gas welding/ brazing work including checking the leakeage in the system and tightening foundation nuts & bolts etc complete all as directed. Note : Gas charging will be measured and paid for separately in respective item of this schedule.
All as per Srl item No. 3 here-in-before but for air conditioner split type, 2 ton capacity, complete all as specified and directed.
Supply & fixing in replacement of PCB circuit with remote control of Window/ Split AC 1.5 ton capacity of any make as existing complete all as specified and directed.
S&F of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 175V to250V and output voltage stabilized between 215V to 240V with accuracy of +/-2.5% and of capacity 4 KVA including dismantling of old one and deposited to MES Store yard complete all as specified and directed.
All as per Srl item No. 6 above but capacity 5 KVA complete all as specified and directed.
Supply & fixing in replacement of PCB circuit with remote control of Split AC 2 ton capacity of any make as existing complete all as specified and directed.
S&F in replacement of electric Blower Motor capacity 1/8 HP, 1100 RPM, SP 230V, 50Hz for indoor unit of Split AC 1.5 ton capacity including testing complete all as specified and directed at site.
S&F in replacement of electric Blower Motor capacity 1/13 or 1/10 HP, 1450 RPM, SP 230V, 50Hz for indoor unit Split AC 1.5 ton capacity including testing complete all as specified and directed at site.
Supply & fixing in replacement air filter for split type Air conditioner of capacity 1.5 TR/ 2 TR complete all as specified and directed.
Supply & fixing in replacement air filter washable of Nylon mesh suitable for window type air conditioner of capacity 1.5 TR complete all as specified and directed at site.
S&F in repair blower Motor 1/5 or 1/6 HP, 230V, AC, 50 Hz suitable for Air conditioner window type 1.5 ton capacity complete all as specified and directed.
S&F in repair Thermostat with regulating knob for AC window/ split type of capacity 1.5TR/ 2.0TR, working on SP, 230V, AC complete all as specified and directed.
S&F in repair evaporating coil assembly with copper tube for window type AC 1.5 TR capacity complete all as specified and directed.
S&F in repair condensing coil assembly with copper tube for window type AC 1.5 TR capacity complete all as specified and directed.
All as per Srl item No.16 but split Air Conditioner 2TR capacity complete all as specified and direted.
S&F in repair copper pencil strainer of similar specification as that of old one (Blue star/ Voltas/ Samsung/ Carrior for 1.5 TR capacity AC) complete all as specified and directed.
S&F in repair Aluminium/ PVC blade for blower motor for window type AC (1.5 TR capacity) complete all as specified and directed.
S&F in repair starting capacitor 40 mfd, working voltage 275 volts, 50 Hz, AC suitable for window type AC of capacity 1.5 TR/2.00TR or water cooler capacity 40/60 lit as per existing make complete all as specified and directed.
All as per Srl item No.20 above but for 60/80 mfd complete all as specified and directed.
S&F in repair running capacitor 36 mfd 440 volts, AC, 50 Hz, type SMRC suitable for AC (Capacity 1.5 TR / 2.00 TR) complete all as specified and directed.
All as per Srl item No.22 above but 45 mfd complete all as specified and directed.
Supply and Fixing in repair Metal clad plug top, 3 pin , 20 Amps, 230 volts complete all as specified and directed.
Supply and Fixing in repair single pole and neutral enclosure Box with metal clad plug and socket 20 Amps complete all as specified and directed.
Supply and Fixing in repair PVC front grill suitable for window type AC of any make any type complete all as specified and directed.
Supply and Fixing in repair three core, 2.5 Sqmm copper wire PVC insulated unsheathed, multistrand 1100V grade drawn through existing PVC conduit/ PVC flexible pipe complete with suitable size of copper lugs etc complete all as specified and directed.
All as per Srl item No.27 here in above but of size 4 Sqmm complete all as specified and directed.
Supply and Fixing in replacement of MCB, Single Pole 10 to 32 Amsp, 240 volts, 'B' series, 10 KA breaking capacity, complete all as specified and directed.
Supply and Fixing in replacement of MCB, Single Pole & Neutral, 240 volts, 'B' series, 10 KA breaking capacity, 32 Amp rating complete all as specified and directed
All as per Srl item No.30 but 40 Amps rating complete all as specified and directed.
Supply and Fixing in replacement of MCB, 3 Pole, 32 Amsp, 240 volts, 'B' series, 10 KA breaking capacity complete all as specified and directed.
Supply and Fixing in replacement of MCB, 4 Pole, 32 Amsp, 240 volts, 'B' series, 10 KA breaking capacity complete all as specified and directed.
M&L for Re-charging of refrigerant gas (R-22) for Air Conditioner of any type, and make but capacity as under after vaccuming dehydration, leak testing of the system as per standard practice testing for proper cooling effects and satisfactory performance complete all as specified and directed for the following capacity of AC:-
(a) AC 1.5 Ton capacity
(b) AC 2 Ton capacity
(c) AC 3 Ton capacity
Supply and fixing in repair relay, box type, for Air Conditioner window/ split type of cap 1.5 Ton.
Water Cooler S&F in repair sealed compressor unit of any make any type for water cooler cap 40 Ltr/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, and fixing new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc and checking the leakage in the system and tightening foundation nuts & bolts etc complete all as specified and directed. Note : Gas charging will be measured and paid for separately in respective items.
All as per item No.40 above but for water cooler Cap 60 Ltrs/hr. complete all as specified and directed.
Note for item No 40 to 41:- Cost of transportation from site to workshop and back will be deemed to be included in the quoted rate. GI Fitting damaged while taking out/fixing back water cooler will be replaced by the contractor at his own cost, the cost of which will be deemed to be included in the quoted rate.
S&F in repair relay current type, for water cooler of any capacity complete all as specified and directed.
S&F in repairs PVC outlet waste pipe for water cooler as per sample & connection complete all as specified and directed.
S&F in repair potential relay box type for water cooler of any capacity all as directed.
S&F in repair Over load protector assembly complete all as specified and directed.
S&F in repair rubber hose pipe of 25mm bore with clips for outlet tray of water cooler approximately 1.5m long as per sample kept in GE's office complete all as specified and directed.
S&F in repair PVC sheet rubber beading and lock for top cover of water cooler by screwing/welding MS sheet of top cover complete all as specified and directed.
S&F in repair float valve assembly 15mm bore of PVC rigid type complete with ball, fixed to water cooler with threaded GI/PVC nipple washer, check nut etc complete all as specified & directed.
S&F in repair PVC connection rigid type 450mm long 15mm bore, with adopter at both ends complete all as specified and directed.
M&L for replacement of old condenser, fins type with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified and directed.
Supply and fixing in repair condenser fan motor of cap 1/35 HP for water cooler with fan blade complete all specified and directed.
All as per Srl item No.53 above but of cap 1/83 HP with fan blade complete all as specified and directed.
All as per Srl item No.53 above but of cap 1/8 HP with fan blade complete all as specified and directed.
S&F in repair thermostat suitable for water coolers of any make and capacity complete all as specified and directed.
Supply and fixing in repair push type self closing tap brass chromium plated for water cooler complete with all accessories washers, rubber packing etc complete all as specified and directed.
S&F in repair steel tray alongwith rubber gasket, waste coupler and GI elbow with check nut of 32mm dia including necessary brazing work suitable for single tap water cooler of any capacity complete all as specified and directed.
S&F in repair 15 Amps Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
Refrigerator S&F in repair compressor for refrigerator of 165 ltr capacity and fixing new sealed compressor unit of existing make and capacity, brazing work, making the system leak proof, vacuumising and charging with by providing gas R-134 and testing complete all as specified directed.
RO System M&L for repair/maintenance of RO system (7 Ltr capacity) of any type and make including replacement of following defective parts:-
(a) Adopter AC to DC convertor for RO system.
(b) Solenoid valve for RO system.
(c) Solenoid filter cartridge for RO system.
(d) Precarbon filter cartridge for RO system.
(e) Post carbon filter cartridge for RO system.
(f) Memberane filter cartridge for RO system.
S&F in repair copper pipes for connection 1/2 bore including insulation complete all as specified and directed.
S&F in repair copper pipes for connection 5/8 bore including insulation complete all as specified and directed.
S&F in repair Bracket for fixing of Acs of any capacity and any make complete all as specified and directed.
Comprehensive Maintenance and servicing to DG set by OEM/ Authorized service centre once in a three month including attending faults on call basis for normal repairs including replacement of defective and worn out minor filters gaskets, V- belts, Engine oil, rubber hoses, worm drive clamps, nuts, bolts and cleaning of alternator with vaccum cleaner and attending faults of AMF panels etc, tappet settings if required and greasing of bearings of engine and alternator, checking of batteries, applying petroleum jelly to battery tereminals, adding distilled water checking the oil, coolent levels Auto Manual functions, contact points, timers of capacity 200 KVA DG set installed at 110 Single officers area Mhow complete all as specified.
Note:- (i) Spares required for maintenance will be measured and paid seprately under relevant items. (ii) Servicing to be carried out as per OEM specifications/ instructions (iii) The whole servicing shalll be carried out through OEM/ Service engineer whose certificate shall be produced to Engineer-in-Charge. (iv) Proper record & test results of the same shall be maintained as directed. (v) Work shall be carried out at site at different location.
All as per item No. 1 but capacity 180 KVA DG set installed at MAP Kodariya. complete all as specified.
All as per item No. 1 but capacity 160 KVA DG set installed at MAP Kodariya and HQ MCTE Mess, complete all as specified.
All as per item No. 1 but capacity 125 KVA DG set installed at FCTS Mhow complete all as specified.
All as per item No. 1 but but capacity 100 KVA DG set installed at HQ MCTE, complete all as specified.
All as per item No. 1 but but capacity 62.5 KVA DG set installed at MAP Kodariya, complete all as specified.
All as per item No. 1 but but capacity 30KVA DG set installed at WB-02, WB-27, GC Mess complete all as specified
Supply only Diesel filter element with 'O' ring suitable for 160 KVA to 200 KVA DG set compete all as specified and directed.
Supply only Diesel filter element with 'O' ring suitable for 125/ 100 KVA DG set compete all as specified and directed.
Supply only Diesel filter element with 'O' ring suitable for 62.5 KVA DG set compete all as specified and directed.
Supply only Diesel filter element as per OEM specification with 'O' ring suitable for 30 KVA DG set compete all specified.
Supply only air filter element as per OEM specification suitable for 180 to 200 KVA DG set compete all as specified and directed.
Supply only air filter element as per OEM specification suitable for 160 KVA DG set compete all as specified and directed.
Supply only air filter element as per OEM specification suitable for 125 KVA DG set compete all as specified and directed.
Supply only air filter element as per OEM specification suitable for 100 KVA DG set compete all as specified.
Supply only air filter element as per OEM specification suitable for capacity 62.50/ 30 KVA DG set compete all as specified.
Supply only Fan Belt as per OEM specification complete suitable for 180 to 200 KVA DG set compete all as specified.
Supply only Fan Belt as per OEM specification complete suitable for 160 KVA DG set compete all as specified and directed.
Supply only Fan Belt as per OEM specification complete suitable for 125 KVA DG set compete all as specified and directed.
Supply only Fan Belt as per OEM specification complete suitable for 100 KVA DG set compete all as specified and directed.
Supply only Fan Belt as per OEM specification complete suitable for capacity 62.50/ 30 KVA DG set compete all as specified.
Supply only Belt as per OEM specification for battery charging alternator complete suitable for 180 to 200 KVA DG set compete all as specified.
Supply only Belt as per OEM specification for battery charging alternator complete suitable for 160 KVA DG set compete all as specified.
Supply only Belt as per OEM specification for battery charging alternator complete suitable for 125 KVA DG set compete all as specified.
Supply only Belt as per OEM specification for battery charging alternator complete suitable for 100 KVA DG set compete all as specified.
Supply only Belt as per OEM specification for battery charging alternator complete suitable for capacity 62.50/ 30 KVA DG set compete all as specified
Supply only Rubber Hose pipe as per OEM specification set for water circuit with clamps complete suitable for 180 to 200 KVA DG set compete all as specified.
Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for 160 KVA DG set compete all as specified.
Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for 125 KVA DG set compete all as specified and as directed. Make:- (As per existing DG Set Make)
Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for 100 KVA DG set compete all as specified.
Supply only Rubber Hose pipe set as per OEM specification for water circuit with clamps complete suitable for capacity 62.50/ 30 KVA DG set compete all as specified.
Supply only Engine oil, multi grade premium Genuine oil 20W/ 40 as per manufacturer recommendations in DG sets complete all as specified and directed.
Supply and applying Petrolium Jelly (01 Kg plastic sealed container) complete all as specified and directed.
Supply and fill distilled water for topping up in lead acid batteries complete all as specified.
Supply and fill electrolyte as per OEM specification of suitable specific gravity for lead acid batteries in sealed container complete all as specified.
M & L for Battery leads as per OEM specification of PVC insulated, multistranded, copper conductor of size 70 Sqmm of 1.25 mtr long ach duly fixed with brass clamps, copper lugs suitable for DG set batteries installed at different locations complete including removal of extg unserviceable one complete all as specified.
M & L for battery teriminal brass clamps as per OEM specification including removal of extg unserviceable one compete all as specified.
M & L for disconnecting all electrical connections from DG set charging alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out the to work shop for rewinding including testing & commissioning complete all as specified.
Taking down turbo charger from engine of DG set of any capacity for servicing and replacement of turbo kit as per OEM specification complete all as specified.
M & L for water temperature guage including sensor and cable as per OEM specification complete as per sample including removal of extg unserviceable one complete all as specified.
M & L for dismantaling the radiator taking to work shop for overhauling & cleaning, de-scaling with acid, removal of leakage including soldering and welding, brazing as required and renewal of gaskets, nuts, bolts, mounting pads, drain out hoses pipe, clips, etc and refixing its original position for following capacities of DG set complete all as specified.
30 KVA DG set to 100 KVA DG set, complete all as specified
125 KVA DG set to 160 KVA DG set, complete all as specified
180 KVA DG set to 200 KVA DG set, complete all as specified
M & L for repair and calibration of FIP and injectors from OEM for petty repairs to make the FIP functional as per standard calibration procedure and norms including replacement of minor spares, gasket etc for smooth functioning of FIP and refixing its original position including testing at site for following capacities of DG set complete all as specified and as directed. Note:- A certificate to the effect that the calibration and repairs has been carried out by the authorised dealer shall be submitted by the contractor.
30 KVA DG set to 100 KVA DG set, complete all as specified
125 KVA DG set to 160 KVA DG set, complete all as specified
180 KVA DG set to 200 KVA DG set, complete all as specified
M & L for Repair/ overhauling of self starting/ Exciter system as per OEM specification of DG set including replacement of corbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 24 volts with necessary connections incluing testing and commissioing complete all as specified.
M & L for Repair/ overhauling of self starting system of DG set including replacement of corbon brushes, bearings, bushes, rewinding of armature and field coil etc and varnishing of capacity 12 volts with necessary connections incluing testing and commissioing complete all as specified and as directed.
M & L for repairing of battery charging alternator engine as per OEM specification mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, corbon brushes of capacity 24 volts including testing and commissioing complete all as specified.
M & L for repairing of battery charging alternator engine as per OEM specification mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, corbon brushes of capacity 12 volts including testing and commissioing complete all as specified.
M & L for AVR (automatic voltage regulator) control unit assembly as per OEM specification suitable for 30 KVA DG set to 160 KVA DG set including removal of extg unserviceable one compete all as specified.
M & L for AVR (automatic voltage regulator) control unit assembly as per OEM specification suitable for 180 KVA DG set to 200 KVA DG set including removal of extg unserviceable one compete all as specified and directed.
M & L for fuel steel braided pipe with benjo bolts and washers as per OEM specification etc of length 30 cm long including removal of extg unserviceable one compete all as specified.
M & L for fuel steel braided pipe with benjo bolts and washers as per OEM specification etc of length 45 cm long including removal of extg unserviceable one compete all as specified.
M & L for fuel steel braided pipe with benjo bolts and washers as per OEM specificationetc of length 60 cm long including removal of extg unserviceable one compete all as specified.
M & L for canopy hinges for auqastic doors with suitable bolts and nuts of DG set including removal of extg unserviceable one compete all as specified and directed by Engr-in charge.
M & L for Anti vibration pads with suitable bolts and washers including removal of extg unserviceable one compete all as specified.
M & L for carrying our repairs to AMF panel/ Auto and Manual of up to 200 KVA DG set at various instllation inclduing study, tracing out circuit, testing, repalcing all defective parts, rewinding existing power and control wiring with same cables including testing and commissioing complete all as specified and as directed. (Note:- Spares like Volt meter, CT, power contactor required for repair will be measured and paid under relevant items. complete all as specified
Supply only for digital type frequency meter 96 x 96mm flush/ square pattern as per OEM specification including removal of extg unserviceable complete all as specified.
Supply only for LED indicator lamps R, Y, B with holder 15mm screw type as per OEM specification including removal of extg unserviceable one complete all as specified.
Supply only for CT cast resin type of ratio 400/ 5 Amps of suitable VA burden as per OEM specification including removal of extg unserviceable one complete all as specified.
Supply only for CT cast resin type of ratio 200/ 5 Amps of suitable VA burden as per OEM specification including removal of extg unserviceable one complete all as specified.
S & F for CT cast resin type of ratio 100/ 5 Amps of suitable VA burden as per OEM specification including removal of extg unserviceable one complete all as specified.
S & F for Power Contactor as per OEM specification 415 Volt, 50 Hz AC suitable for DG set control panel/ AMF panel for following capacity of DG set including removal of extg unserviceable complete all as specified.
100 KVA DG set to 160 KVA DG set complete all as specified
180 KVA DG set to 200 KVA DG set complete all as specified
S & F for Time dealy relay as per OEM specification suitable for 30 KVA DG set to 100 KVA DG set including removal of extg unserviceable one complete all as specified and as directed.
S & F for Time dealy relay as per OEM specification suitable for 125 KVA DG set to 200 KVA DG set including removal of extg unserviceable one complete all as specified and as directed.
M & L for solinoid switch assembly 24 volts as per OEM specification suitable up to 200 KVA DG set including removal of extg unserviceable one complete all as specified and directed by Engr-in charge.
M & L for solinoid switch assembly 12 volts as per OEM specificationsuitable up to 200 KVA DG set including removal of extg unserviceable complete all as specified.
M & L for self starter assembly 12 volts as per OEM specification complete suitable up to 200 KVA DG setincluding removal of extg unserviceable one complete all as specified.
M & L for self starter assembly 24 volts complete suitable up to 200 KVA DG set including removal of extg unserviceable one complete all as specified.
M & L for electronic speed control unit assembly 12 volts as per OEM specificationsuitable up to 200 KVA DG set including removal of extg unserviceable complete all as specified.
M & L for electronic speed control unit assembly 24 volts as per OEM specification suitable up to 200 KVA DG set including removal of extg unserviceable complete all as specified.
M & L for SMPS (system main power supply) type control unit assemblyas per OEM specification suitable for 12 volts battery charger for including removal of extg unserviceable complete all as specified.
M & L for SMPS (system main power supply) type control unit assembly as per OEM specificationsuitable for 24 volts battery charger for including removal of extg unserviceable complete all as specified.
S & F for single phase preventer as per OEM specification suitable for operation on 415 Volts 50 Hz AC supply including removal of extg unserviceable one complete all as specified.
S & F for battery low maintenance lead acid of capacity 12 volts 180 AH with initial charging including removal of extg unserviceable one complete all as specified.
S & F battery low maintenance lead acid of capacity 12 volts 150 AH with initial charging including removal of extg unserviceable one complete all as specified.
M & L for welding MS pipe heavy duty 100mm dia suitable for exhaust manifold of DG set with necessary scraping cutting to size as required and painting with two coats silver paint over a coat of redoxide primer including removal of extg unserviceable complete all as specified
M & L for Engine complete overhauling of DG set capacity UP TO 200 KVA of Kirloskar/ Crompton Greaves makes by opening the top cover complete including dismatlling the engine head, cylinder liner and piston assembly, crankshaft assembly, radiater fan belt and radiator fan, gear assembly complete removing of engine side for repair/ replacement of parts i.e gasket, washer, 'O' ring all types etc including grinding polishing of crank shaft, head repairing and overhauling valve seat cutting and replacing, valve tapping, head assemble and testing of DG set after necessary repair with and authorised dealer fix at site reassembling of DG set and testing on full load upto entire satisfaction of Engineer in Charge all as directed (Note:- Spare parts will be measured and paid seperately under relevent items)
Supply only Piston assembly, complete all as specified
Supply only Piston ring set, complete all as specified
Supply only full engine gasket, complete all as specified
Supply only Main bearing set, complete all as specified
Supply only Main cylinder liner, complete all as specified
Supply only Main cylinder head copper sleeves, complete all as specified
Supply only Lock nut, compelte all as specified
Supply only Big end bearing, complete all as specified
Supply only Timing Belt, complete all as specified
Supply only benjo bolt, complete all as specified
Supply only Timing belt tension adjuster, complete all as specified
Supply only inlet valve, complete all as specified
Supply only Exhaust Valve, complete all as specified
Supply only head gasket, complete all as specified.
Supply only oil pump assembly, complete all as specified
Supply only Thrust washer, complete all as specified
Supply only Crank case gasket, complete all as specified
Supply only Head nozzle plug set, complete all as specified
S & F for pressure gauge 0 to 7 Kg/ Sqcm as per OEM specificationalong with sensor and cables for DG set including removal of extg unserviceable one complete all as specified
S & F for microprocessor based multifunction controller as per OEM specification suitable for DG sets operation of any capacity and showing the various parameters such as volt, ampere, frequency, RPM etc complete as per site requirment including removal of extg old unserviceable one, complete all as specified
S & F connecting and testing MCCB in existing DG set Panel of the following capacity, suitable for 415 volts, 50 Hz, with extended terminals type, inter locked to prevent opening when the Switch is in ON Position, connecting and testing complete including removal of exiting unsv complete all as specified.
(a) 4 pole 200 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu, complete all as specified.
(b) 4 pole 400 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu, complete all as specified
(c) 4 pole 160 Amps with thermal magnetic release breaking capacity 36 KA, Ics=100% Icu, complete all as specified
S & F connecting and testing open execution on load change over in existing DG set Panel of the following capacity, suitable for 415 volts, 50 Hz, 250 Amp, 4 pole with extended terminals type, interlocked to prevent opening when the Switch is in ON Position, connecting and testing complete including removal of exiting unsv complete all as specified.
Supply and fill genuine coolant in 5 ltrs plastic sealed container for topping up in Radiator of DG set located at different locations as directed by Engr-in-Charge complete all as specified.
M & L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to galvanized iron strep 32 x 6mm as earthing lead by mean of nut/bolt and washer of galvanized iron or steel drawn through 40mm dia light grade GI pipe as shown in electrical plate no 3 of SSR Part-I of 2009 including necessary excavation and earth work GI pipe 20mm dia light grade for watering PCC chamber with PCC cover in cement concrete 1:2:4 Type B1 (20mm graded aggregate), funnel, wire mesh, charcoal dust, salt etc, connected to panel board as indicated including testing complete all as specified.
M & L for disconnecting all electrical connections from Coupling and flywheel DG set alternator of any capacity from base plate by opening nuts & bolts keeping aside the alternator for inspection and taking out the to work shop for rewinding including testing & commissioning complete all as specified.
Rewinding of alternator field coil with super enamelled copper winding wire of class 'F' insullation as per existing size and gauge including heating, varnishing and testing of size up to 200 KVA complete all as specified.
Vending Services And Solutions (BID ID -3370475)
SAHYOG ELECTRIC (BID ID -3372460)
MODI CORPORATION (BID ID -3367541)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .