Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-Finance | L1 | Accepted-Finance Ist Lowest bidder | |
| 2 | L2₹3.0 L+₹540 (0.18%)Accepted-Finance FASHAS KHANA RAMPUR JANPAD RAMPUR UTTAR PRADESH | RAMPUR | RAMPUR | UTTAR PRADESH | L2 | Accepted-Finance IInd Lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Online Paper Not Submit as per Terms and Condition |
| Sl No | Description | Qty | Unit | CHAUDHARY CONTRACTOR L2 | FAGGU RAM & COMPANY L1 |
|---|---|---|---|---|---|
| 1.00Detail of Work | |||||
| 1.01 | Safe Removal and carriage of damage 01 No 11 KV I/C VCB, Damage 09 No Line Isolator, 01 Damage 33 KV VCB & 33 KV Damage Control pannel Single T/F from site of work to ESC SRE including loading and unloading at both ends. | 1 | Job | 10,250 ₹10,250 Lowest | 10,500 ₹10,500 |
| 1.02 | Safe carriage of 11 KV 1 No I/C & 1 No O/G VCB from ESC SRE to Site of work including loading and unloading at both ends. | 2 | No | 5,400 ₹10,800 Lowest | 5,500 ₹11,000 |
| 1.03 | Safely installation of 11 KV 01 No I/C VCB & 01 No O/G VCB and connection properly. | 2 | No | 10,000 ₹20,000 Lowest | 10,000 ₹20,000 Lowest |
| 1.04 | water level Earthing of VCB (1 No body & 1 No. neutral earthing) by boring of till water level minimum 60 Ft deep & fixing of G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 50x6 mm and copper strip at bottom of G.I pipe to the VCB providing of required charcoal & salt in the pipe | 2 | No | 25,500 ₹51,000 | 25,250 ₹50,500 Lowest |
| 1.05 | Civil work installation of New 11 KV O/G VCB. | 1 | Job | 25,500 ₹25,500 | 25,250 ₹25,250 Lowest |
| 1.06 | Safely Carriage of Line Isolator from ESC SRE to Site of work including loading and unloading at both ends. | 9 | NO | 750 ₹6,750 Lowest | 800 ₹7,200 |
| 1.07 | Safely Installation of Line Isolator and connection properly. | 9 | No | 1,550 ₹13,950 | 1,540 ₹13,860 Lowest |
| 1.08 | Safe carriage of 33 KV VCB (1 No), 33 KV Control Pannel for Single T/F (1 No) from ESC SRE to Site of work including loading and unloading at both ends. | 2 | No | 5,000 ₹10,000 Lowest | 5,000 ₹10,000 Lowest |
| 1.09 | Safely Installation of 33 KV VCB 800A, 750 MVA and making connection properly to C&R pannel through Control cable. | 1 | No | 10,000 ₹10,000 Lowest | 10,000 ₹10,000 Lowest |
Tender Value
₹2.9 L
EMD Value
₹3,000
Closing Date
2 Aug 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
EDC I Saharanpur
Various Electrical work in CM Nagar Sarjan Yojana in the area of EDSD Sarsawa under EDD Sarsawa
2025_PVVNL_1060305_1
99/W/EDC-I/SRE/2024-25
Open Tender
Electrical Works
Lump-sum
45 days
saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
SE EDC I SRE
₹3,000
Yes
4 Sept 2025
26 Jul 2025
2 Aug 2025
26 Jul 2025
2 Aug 2025
26 Jul 2025
Amount
Detail of Work
Safe Removal and carriage of damage 01 No 11 KV I/C VCB, Damage 09 No Line Isolator, 01 Damage 33 KV VCB & 33 KV Damage Control pannel Single T/F from site of work to ESC SRE including loading and unloading at both ends.
Safe carriage of 11 KV 1 No I/C & 1 No O/G VCB from ESC SRE to Site of work including loading and unloading at both ends.
Safely installation of 11 KV 01 No I/C VCB & 01 No O/G VCB and connection properly.
water level Earthing of VCB (1 No body & 1 No. neutral earthing) by boring of till water level minimum 60 Ft deep & fixing of G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 50x6 mm and copper strip at bottom of G.I pipe to the VCB providing of required charcoal & salt in the pipe
Civil work installation of New 11 KV O/G VCB.
Safely Carriage of Line Isolator from ESC SRE to Site of work including loading and unloading at both ends.
Safely Installation of Line Isolator and connection properly.
Safe carriage of 33 KV VCB (1 No), 33 KV Control Pannel for Single T/F (1 No) from ESC SRE to Site of work including loading and unloading at both ends.
Safely Installation of 33 KV VCB 800A, 750 MVA and making connection properly to C&R pannel through Control cable.
Safely installation of 33 KV Control Pannel for Single T/F and connection properly.
Structure Paints (Providing Paints & Labour) of 33 KV VCB 800A, 750 MVA
Safely Removal of Damage 33 KV Control Cable 4x2.5/2x2.25 sq.mm site to ESC SRE including loading and unloading at both ends.
Safely Carriage of 33 KV Control Cable size 4x2.5/2x2.5 from ESC SRE to Site of Work including loading and unloading at both ends.
Laying of 33 KV Control Cable 4x2.5 sq.mm
Laying of 33 KV Control Cable 2x2.5 sq.mm
Providing of Fire Extinguisher.
Providing of Fire Bucket with sand (03 No Bucket)
CHAUDHARY CONTRACTOR (BID ID -5393944)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .