Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹28.8 LAccepted-AOC | L-1 | Accepted-AOC BEING LOWEST | |
| 2 | L-2₹32.4 L+₹2.8 L (9.48%)Rejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L-2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L-3₹33.8 L+₹4.2 L (14.1%)Rejected-Finance | L-3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
18 Aug 2020, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIRS TO INTERNAL ELECTRIFICATION AND EXTERNAL ELECTRIFICATION, STREET / LED LIGHT, DISTRIBUTION BOX, FEEDER PILLAR AT ASTE AND VISHWA VIHAR UNDER GE (AF) MARATHAHALLI BANGALORE.
2020_MES_364595_1
GE (AF) MARATHAHALLI / 8842 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) MARATHAHALLI
Class E and above with Category b (I)
7 documents required · 7 mandatory
₹500
Yes
GE (AF) MARATHAHALLI
₹76,000
Yes
GE (AF) MARATHAHALLI
18 Dec 2020
27 Jul 2020
20 Aug 2020
27 Jul 2020
18 Aug 2020
30 Jul 2020
28 Jul 2020 - 30 Jul 2020
30 Jul 2020
Amount
Taking down carefully Unserviceable Copper / Aluminium Point Wiring of any type batten or conduit, surface or concelaed (Light, Fan, Socket or power) complete including removing material from site and making good the disturbed surfaces of walls, roofs etc to match the existing Complete all as directed by Engr-In-Charge. Note: Taking down of Fittings and Fixtures shall be measured under respective Items Separately.
Taking down carefully Unserviceable Sub main wiring of any size and type batten or conduit, surface or concelaed including removing material from site and making good the disturbed surfaces of walls, roofs etc to match the existing Complete all as specified and as directed. Note: Taking down of Fittings and Fixtures shall be measured under respective Items Separately.
Material and Labour for Point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly Complete all as specified and as directed for One LIGHT / FAN / EXHAUST FAN / SOCKET point controlled by One, One way switch 5/6 Amps.
Material and Labour for Point wiring complete with 1.5 Sqmm Single core PVC insulated unsheathed FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non- metallic rigid PVC conduit of 20 mm dia and all conduit accessories (surfaced/concealed in walls/ceilings/floors/roof) and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor connected to common earth dolly in existing mild steel terminal boxes with new 3mm thick hylem sheet top cover for housing switches, socket outlets, fan regulators with frame concealed in walls top cover fixed with brass screws and cup washers etc, Complete all as specified and as directed. for One 5/6A Socket Point Controlled by One Switch on Same Board with 5/ 6 Amps Switch Complete all as specified and as directed.
Material and Labour for Casing / Caping wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable including PVC Cassing and capping of size 25mm including complete with all accessories / fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly Complete all as specified and as directed for One LIGHT / FAN / EXHAUST FAN /SOCKET point controlled by One, One way switch 5/6 Amps.
Material and Labour for Point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable including PVC concealed conduit of 25 mm dia or higher, medium grade complete with and including all PVC conduit accessories / fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting / chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly Complete all as specified and as directed for One 15/16 Amps Socket Outlet point on independent board controlled by one, one way 15/16 Amps switch.
Material and Labour for Caping / Casing wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed copper conductor cable with and including all accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated copper conductor cable, unsheathed and connected to common earth and earth dolly Complete all as specified and as directed for One 3/5 pin, 15/16 Amps socket outlet point on independent board controlled by one, one way 15/16 Amps switch.
Supply and Fixing Switch piano flush type, single pole, one way 230 volts 5 Amps Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Socket outlet 2 in 1, 3 pin, 5/6A 240 volts Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Switch Socket Outlet 2 in 1, 3 pin, 15/16 amp flush type 240 volts Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Switch Piano Flush type, Single pole, One way 230 volts 15 / 16 Amps Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing Ceiling rose, 3 terminal / PVC / polycarbonate, isolated body Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Bell push flush type, Single pole, one way, 5 Amps, 240 V Complete all as specified and as directed.
Supply and Fixing in repairs Bell Ding Dong, flush type, Single pole, one way, 5 Amps, 240 V Complete all as specified and as directed.
Supply and Fixing in repairs Switch Socket Combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type with fuse and neon indicator, 240 volts Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing Switch socket combination 2 -in-1, 3 pin/5 pin, 5 Amps 240 volts Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Modular Switch with One module, flush type, Single pole, one way 230 volts 5 Amps Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Modular Switch with One module, flush type, Single pole, two way 230 volts 5 Amps Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Bell push, modular type, two module Single pole, one way, 6 Amps, 240 V Complete all as specified and as directed.
Supply and Fixing in repairs Modular type socket outlet two module combination 2 -in-1, 2 pin / 3 pin, 5 Amps 240 volts Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Modular Switch with One module, flush type, Single pole, one way 240 volts 16 Amps Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Modular type socket outlet two module combination 2 -in-1, 2 pin / 3 pin, 6 Amps / 16 Amps 240 volts Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Modular type Fan step regulator, 120W - 2 module Complete all as specified and as directed. Make: Havell`s / Anchor / Legrand
Supply and Fixing in repairs Stepped type Electronic Fan regulator Socket type 400W including the removal of switch board panel and making the provision for fixing etc Complete all as specified and as directed.
Supply and Fixing in repairs MCB DB SPN 4 way, Horizontal, Double door, 240 V, AC, 50 Hz, with sheet metal enclosure for MCB DP as Incomer and SPN MCBs as Out going, IP-43 protection conforming to IS-13032, universal mounting with copper bus bar 200 Amps, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides fixed on surface of walls of concealed Complete all as specified and as directed. Make: Legrand Cat No. 6077 10 or equivalent in standard/ L&T/ Havells
Supply and Fixing in repairs MCB DB SPN 8 way, Horizontal, Double door, 240 V, AC, 50 Hz, with sheet metal enclosure for MCB DP as Incomer and SPN MCBs as Out going, IP-43 protection conforming to IS-13032, universal mounting with copper bus bar 200 Amps, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides fixed on surface of walls of concealed Complete all as specified and as directed. Make: Legrand Cat No. 6077 11 or equivalent in standard/ L&T/ Havells
Supply and Fixing in repairs MCB DB SPN 12 way, Horizontal, Double door, 240 V, AC, 50 Hz, with sheet metal enclosure for MCB DP as Incomer and SPN MCBs as Out going, IP-43 protection conforming to IS-13032, universal mounting with copper bus bar 200 Amps, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides fixed on surface of walls of concealed complete all Complete all as specified and as directed. Make: Legrand Cat No. 6077 12 or equivalent in standard/ L&T/ Havells
Supply and Fixing in repairs MCB DB TPN 4 way, horizontal, double door, 240 V, AC, 50 Hz, with sheet metal enclosure for MCB DP as incomer and SP MCBs as out going, IP-43 protection conforming to IS-13032, universal mounting with copper bus bar 200 Amps, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides all Complete all as specified and as directed. Make: Legrand Cat No. 6077 15 or equivalent in standard/ L&T/ Havells
Supply and Fixing in repairs Vertical MCCB DB double door, TPN 8 ways including MCCB TPN 25 KA 125 Amps - 01 No with suitable bus bar including taking out existing DB, removing cable / wires and reconnecting the cable / wires with suitable size lugs complete all as specified and directed. Make: (i) Legrand Cat No: 5077 52 for DB or / Havell`s / L&T / Standard. (ii) Legrand Cat No: 4200 06 for MCCB or / Havell`s / L&T / Standard.
Material and Labour for Sub main wiring complete with two runs of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4.00 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor and connected to common earth dolly drawn through and including 20 mm non- metallic rigid PVC conduit and conduit accessories (surfaced/concealed in walls/ceilings/floors/roof) etc all as specified and directed. Note: 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one running metre Complete all as specified and as directed.
Material and Labour for Sub main wiring complete with two runs of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor and connected to common earth dolly drawn through and including 20 mm non- metallic rigid PVC conduit and conduit accessories (surfaced/concealed in walls/ceilings/floors/roof) etc all as specified and directed. Note: 2 runs of PVC FRLS cable, one run of earth continuity conductor cable and one run of PVC conduit shall be measured as one running metre Complete all as specified and as directed.
Material and Labour for Cutting chases not exc 10 cm girth, pinning in making good to facing where required and pointing in CM (1:3) to ends or edges of landing, steps, chills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc; and making good Complete all as specified and as directed.
Supply and Fixing MCB SPN 40 Amps rating, 'C' series, 10 KA breaking capacity, 240V, 50 Hz AC Complete all as specified and as directed. Make: Legrand Cat No. 4086 17 or equivalent in standard/ L&T/ Havells
Supply and Fixing MCB SP 6 to 32 Amps rating, 'C' series, 10 KA breaking capacity, 240V, 50 Hz AC Complete all as specified and as directed. Make: Legrand Cat No. 6032 31 - 37 or equivalent in standard/ L&T/ Havells
Supply and Fixing in repairs MCB TPN 40/63 Amps rating, 'C' series, 10 KA breaking capacity, 415V, 50 Hz AC Complete all as specified and as directed. Make: Legrand Cat No. 6033 25 or equivalent in standard/ L&T/ Havells
Supply and Fixing in repairs MCB TP 63 Amps rating, 'C' series, 10 KA breaking capacity, 415V, 50 Hz AC complete all as specified. Make: Havells Cat No. DHMCCTPF063 or equivalent in standard/ L&T/ Legrand
Supply and Fixing in repairs energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser complete with and incl 10W LED Complete all as specified and as directed. Make: Havells Code : LHEOAOP7UZ6W010 or equivalent in HPL/Philips.
Supply and Fixing in repairs 1 x 14W light fitting, Lumiline LED tube with Box type fitting, Two feet 10W Complete all as specified and as directed. Make: Havell`s Cat Part No.LHEXBQP7PN1W009 or Equivalent in CG / Philips
Taking down old unserviceable T5 28Watts light fitting, Supply and Fixing Lumiline LED tube with Box type fitting, 4 feet, 18 watts Complete all as specified and as directed. Make: Bajaj Cat no- BCLSB 18 WH or Equivalent in CG/Philips.
Taking down unserviceable 1x36watts tube rod Supply and Fixing linear LED T8 tubular lamp 18W with extruded aluminium/PC body and PC diffuser complete with inbuilt driver incl making necessary connections in the existing fittings to suit the LED tube Complete all as specified and as directed. Make: BajaJ Cat No- BLRB 18W CWc or equivalent in Havells/Philips.
Taking down unserviceable 1x20 watts tube rod, Supply and Fixing linear LED T8 tubular lamp 10/15 W with extruded aluminium/PC body and PC diffuser complete with inbuilt driver in repalcement of old u/s 1x20watts tube rod incl making necessary connections in the existing fittings to suit the LED tube Complete all as specified and as directed. Make: BajaJ Cat No- BLRB 15W CWc or equivalent in Havells/Philips.
Taking down old unserviceable 1x28W light fitting for repairs, Supply and Fixing T5 LED tube, 4Ft of 15 Watts along with driver and making all necessary connections in the existing fittings and refixing the same back to its position Complete all as specified and as directed. Make: Bajaj Cat NO- BLTB 15W CWC or equivalent inHavells/CG/Philips.
Taking down old unserviceable Ceiling/wall fittings of 1x11W/20W of any type, Supply and Fixing LED fitting of 8 watts - Square surface mounted LED flat panel down light, PDC aluminum housing and PMMA diffuser makes it a robust Luminaire alongwith 8W LED lamp Complete all as specified and as directed. Make: Bajaj cat no-BGSLO sleek surface 8W WH SQ or equivalent in Havells/Philips.
Taking down unserviceable 1x11 W mirror light fitting, Supply and Fixing Aesthetically designed linear mirror light, 10W provided with a high output PMMA diffuser for glare free light and making all connections Complete all as specified and as directed. Make: Havells code-LHFOECF1OZ1W011 equivalent in CG/ Philips.
Taking down old unserviceable wall mounted decorative fitting of any type, Supply and Fixing Decorative wall light fixture made up of Polycarbonate, complete incl 5W LED lamp Complete all as specified and as directed. Make: Havells, Code - LHDL02160099 or equivalent.
Taking down old unserviceable 20 W CFL, Supply and Fixing LED lamp 10 watt Complete all as specified and as directed. Make: Havells Code -LHLDEBUEML8Z015 or equivalent in CG/Philips.
Taking down old unserviceable 11/15 W CFL, Supply and Fixing LED lamp 5 watt Complete all as specified and as directed. Make: Havells Code -LHLDEROEMK8X003 or equivalent in CG/Philips.
Taking down old unserviceable 11 W CFL Supply and Fixing CFL lamp 11watt pin type 2 pin Complete all as specified and as directed. Make: Havells Code -PHCS*#011 or equivalent in CG/Philips.
Taking down Ceiling fan / Exhaust fan, sealing the cable ends ,dismantling the fan blade and keeping in safe custody Complete all as specified and as directed. Note: Servicing of fans and Spares will be measured and paid separately under relevant items of this schedule.
Material and Labour for preperation and painting of ceiling fan complete, at site with synthetic enamel paint by spraying painting including filling cavities with filler,one coat after cleaning Complete all as specified and as directed.
Hanging Only Ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost Complete all as specified and as directed.
Material and Labour for Servicing the Ceiling / Exhaust fan of any size by Cleaning, Oiling, greasing & assemble the fan properly including replacing the rusted bolts, cater pins, rubber wheel bearing washers, bushes etc., and tightening all the bolts, nuts,screws, clamps etc Complete all as specified and as directed.
Supply Only GM bush suitable for Ceiling fan 1200 / 1400 Sweep Complete all as specified and as directed. Make: Crompton Greaves / Bajaj / Usha
Supply Only Ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans of 1200 / 1400 Sweep Complete all as specified and as directed. Make: SKF / NBC / TATA or equivalent.
Supply Only 2.5 MFD Capacitors for the fan in position Complete all as specified and as directed.
Supply Only 4 MFD Capacitors of the fan in position Complete all as specified and as directed.
Material and Labour for dismantling the defective Exhaust fans motor taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, "O" rings and other petty items required for making motor functional Complete all as specified and as directed.
Material and Labour for dismantling the defective Ceiling fans motor taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional Complete all as specified and as directed.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 16 to 25, Sqmm 3.5 core Complete all as specified and as directed. Make:- 3M Code- HSLA - 2/4C or equivalent in Densons.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 35 to 50, Sqmm 3.5 core Complete all as specified and as directed. Make:- 3M Code- HSLA - 2/4C or equivalent in Densons.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 150 to 185 Sqmm, 3.5 core Complete all as specified and as directed. Make:- 3M Code- HSLA - 2/4C or equivalent in Densons.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 95 to 150, Sqmm 3.5 core Complete all as specified and as directed. Make:- 3M Code- HSLA - 2/4C or equivalent in Densons. Note for ser item No. 58 to 61: (i) Earth work excavation, Sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule.
Material and Labour for Fault location of LT UG cables by using measuring instruments and rectification of the same by using epoxy cable joints of suitable size of cables and testing the phase contuinity of the cable Complete all as specified and as directed. Note: Cable joint kit and Excavation / earth work shall be measured and paid seperately.
Supply and Fixing in repairs MCCB TPN 415 volts 50 HZ AC suitable for current carrying capacity 250 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA Complete all as specified and as directed. Make: Cat Part No Havells IHLANF0250 or equivalent in standard/ L&T/ Legrand
Supply and Fixing in repairs MCCB TPN 415 volts 50 HZ AC suitable for current carrying capacity 200 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA Complete all as specified and as directed. Make: Cat Part No Havells IHLANF0200 or equivalent in standard/ L&T/ Legrand
Supply and Fixing in repairs MCCB TPN 415 volts 50 HZ AC suitable for current carrying capacity 100 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA Complete all as specified and as directed. Make: Cat Part No Havells IHLASF0100 or equivalent in standard/ L&T/ Legrand
Supply and Fixing in repairs MCCB TPN 415 volts 50 HZ AC suitable for current carrying capacity 63 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA Complete all as specified and as directed. Make: Cat Part No Havells IHLASF0063 or equivalent in standard/ L&T/ Legrand
Supply and Fixing in repairs MCCB TPN 415 volts 50 HZ AC suitable for current carrying capacity 32 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA Complete all as specified and as directed. Make: Cat Part No Havells IHLASF0032 or equivalent in standard/ L&T/ Legrand
Material and Labour for preperation of old painted Post top poles 3 metres height 50 mm dia of any description and applying two coats of synthetic enamel paint Complete all as specified and as directed.
Excavation in trenches in Soft / loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient Complete all as specified and as directed.
Returning filling including Spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick Complete all as specified and as directed
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils Complete all as specified and as directed.
Material and labour for River Sand Cushioning to cables with a layer of sand 8CM before and 15CM after laying the cable Complete all as specified and as directed. Note :- Sand shall be measured after punned down.
Material and Labour for Brick protection cover on cable with sub class 'B' bricks, across in trenches laid dry and flat adjacent to each other Complete all as specified and as directed
Material and Labour for G.I. tubing medium grade of size 50mm bore for protection of cables to be laid under roads, crossings / culverts Complete all as specified and as directed.
Taking out old unserviceable UG cable, supply and laying 10 sqmm, 2 core LT UG cable grade PVC insulated, PVC sheathed armoured, heavy duty, in trenches/ walls/poles/passing through pipes with multistranded aluminium conductor including lugs/ thimbles/ ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable, supply and laying 25 sqmm, 3.5 core LT UG cable grade PVC insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable, Supply and laying 50 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable, Supply and laying 95 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed. Note for ser item No 79 to 82: (i) Earth work excavation, sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule.
Supply and Fixing in repairs Metal clad switch socket Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20 Amps and fixed concealed in walls Complete all as specified and as directed.
Supply and Fixing in repairs 1100 Volts grade heavy duty cable with PVC insulated stranded aluminium conductor 10 Sqmm 2 Core served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulated hanger not more than 1 mtr a part including 4mm suspension wire, one twin core cable flat or circular Complete all as specified and as directed. Make: Finolex / Plaza / Kalinga / Universal
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure Complete all as specified and as directed.
Material and Labour for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth strip 25x3 mm by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., Complete all as specified and as directed. Note: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Material and Labour for Earthing complete with copper plate electrode electrode 600 mm x 600 mm x 3.15 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to Copper earth strip 20x3 mm by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., Complete all as specified and as directed. Note: (i) The unit rate includes earth wire and protection pipe up to (maximum 7.5 metre from earth plate) earth point/test point. (ii) Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Taking down perished / dishaped, horizontal / vertical aluminimum conductor of any size and Supply and Fixing GI strip of size 25 x 4 mm fixed to wall with insulator to over head tank / Storage shed or any other indicated situation Complete all as specified and as directed. Note: The quoted rate deemed to include for Scaffloding / Cradles etc ., including necessary execution of work and protective measures Complete all as specified and as directed.
Supply and Fixing in repairs LED decorative post top lantern fitting 25W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection Complete all as specified and as directed. Make: Havells Cat No: LHEVBHP7PN6K025 or BLPTSP 25W NW LED of Bajaj or equivalent model in Crompton Greaves Ltd/ Philips
Supply and Fixing in repairs PVC terminal boxes of size 255 x 200 x 100mm, to pole by means of mild steel clamps with hinged door, bolts and nuts, provn for cable entry for incoming and outgoing including MCB SP 20 Amps-01 No 10KA and 3 way Epoxy connector-01 No and making all necessary connections duly fixed with clamps on pole and including cable glands threaded type IP55/IP65 made of polymide with lock nut Complete all as specified and as directed. Make: Sintex:- GSJB-2520 or Equivalent in Hensel
Material and labour Plain cement concrete (1:4:8) type D2 using 20 mm graded stone aggregate as in foundations of filling and mass concrete and coping for poles including necessary from work Complete all as specified and as directed.
Material and Labour for Plain cement concrete (1:3:6), type C1, using 20mm graded stone aggregate as in coping, bases of electric poles including necessary form work and finishing the exposed concrete surfaces of concrete even and fair Complete all as specified and as directed.
Supply and Fixing in repairs LED Street light fittings 1 x 45 W Versatile Pressure die cast aluminium housing, heat resistance toughened glass with acrylic cover, IP-66 protection complete with inbuilt driver with all accessories and including connecting up Complete all as specified and as directed. Make: Havell`s Cat Part No: Endura City Light Platinum LHETAXU7PN6J045 or its equivalent in Philips / Bajaj / Crompton & Greaves.
Supply and Fixing in repairs IP68 LED Fountain Light, LED Pool Under water Light Piscina, 3W, 12VAC LED Landscape Spot lamp LPL-A-3W-12V including making of water proof connections Complete all as specified and as directed. (Make:- Piscina or Equivalent in CG / Philips.
Supply and Fixing in repairs LED Street light fittings 1 x 90 W Versatile Pressure die cast aluminium housing, heat resistance toughened glass with acrylic cover, IP-66 protection complete with inbuilt driver with all accessories and including connecting up Complete all as specified and as directed. Make: Havell`s Cat Part No: Endura Cityliner LHETBXU7PN6J090 or its equivalent in Philips / Bajaj / Crompton & Greaves.
Supplying and Fixing in repairs Street light LED driver unit suitable for 30 to 45 watts Complete all as specified and as directed. Make: Bajaj or equivalent in CG/Philips.
Supplying and Fixing in repairs Street light LED driver unit suitable for 70 to 150 watts Complete all as specified and as directed. Make: Bajaj or equivalent in CG/Philips.
Supply Only 5 KVAR Capacitor (MPP, Heavy duty) 440 volts with inrush current Limiting Coil Complete all as specified and as directed.
Supply Only 10 KVAR Capacitor (MPP, Heavy duty) 440 volts with inrush current Limiting Coil Complete all as specified and as directed.
Supply Only 7 KVAR Capaitor duty contactor Complete all as specified and as directed.
Supply Only Add on Auxiliary contact Block 4 NO Complete all as specified and as directed.
Supply and fix 36 W LED, high efficacy 2 x 2 recess LED flat panel with high brightness LED for glare free homogenous illumination including LED Driver all as specified and directed. Make: Crompton (Polaris I) Cat No : LCLRN-36-FO-CDL / Equivalent Cat No of Bajaj/HPL
Maintenance of storage type electric water heaters (Geyser) of 25 ltrs capacity, comprising the following tasks complete all as specified and directed by Engr-in-Charge. (a) Inspection taking down, opening (dismantling), descaling, brushing, cleaning of storage tank. (b) Examine water tightness of storage tank after cleaning. (c) Carry out operation of all stop cocks, pressure reducing valves etc., to ensure free movement of the working parts. (d) Replacement washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow/vent pipes and remove blockages obstructions if any. (f) Check and correct earth continuity of electrical items. (g) Check maintain and refit thermostats and test its functioning. (h) Checking and adjustment of pressure reducing valve. (j) Checking of dead weight type High pressure release valve (HPRV) by removing dead weight portion cleaning the seat and ensuring that the vent hole is not blocked/choked. (k) Visual examination of fusible plug (l) Descaling of the immersion type heating element and cleaning with diluted hydrochloric acid or "clear pedette" solution and testing before refitting. (m) Checking functioning of neon lamp/indicator lamp. (n) Replacement of the rubber/PVC gaskets to ensure water tightness. (o) Testing of geysers after repairs and maintain a proper register and put up to Engr-in-Charge after completion of each job. Note : (i) During the currency of the contract period, if after doing the job any complaint is noticed then the intimation will be conveyed to the contractor over telephonic message and the contractor has to rectify the defects within 24 hours of receipt of complaint. (ii) Necessary register shall be maintained in this regard and put up to Engr-in-Charge after completion of each complaints. (iii) The spares will be measured and paid separately.
Maintenance of storage type electric water heaters (Geyser) of 50 ltrs capacity, comprising the following tasks complete all as specified and directed by Engr-in-Charge. (a) Inspection taking down, opening (dismantling), descaling, brushing, cleaning of storage tank. (b) Examine water tightness of storage tank after cleaning. (c) Carry out operation of all stop cocks, pressure reducing valves etc., to ensure free movement of the working parts. (d) Replacement washers and glands of all taps and ball valves to ensure water tightness. (e) Inspect overflow/vent pipes and remove blockages obstructions if any. (f) Check and correct earth continuity of electrical items. (g) Check maintain and refit thermostats and test its functioning. (h) Checking and adjustment of pressure reducing valve. (j) Checking of dead weight type High pressure release valve (HPRV) by removing dead weight portion cleaning the seat and ensuring that the vent hole is not blocked/choked. (k) Visual examination of fusible plug (l) Descaling of the immersion type heating element and cleaning with diluted hydrochloric acid or "clear pedette" solution and testing before refitting. (m) Checking functioning of neon lamp/indicator lamp. (n) Replacement of the rubber/PVC gaskets to ensure water tightness. (o) Testing of geysers after repairs and maintain a proper register and put up to Engr-in-Charge after completion of each job. Note : (i) During the currency of the contract period, if after doing the job any complaint is noticed then the intimation will be conveyed to the contractor over telephonic message and the contractor has to rectify the defects within 24 hours of receipt of complaint. (ii) Necessary register shall be maintained in this regard and put up to Engr-in-Charge after completion of each complaints. (iii) The spares will be measured and paid separately.
Supply only new heating element suitable to existing model and make of storage type geysers, 2 KW Dual clip type / triangle type / round type with rubber gasket suitable for geysers up to 25 / 50 Ltr capacity Complete all as specified and as directed. Make: Theeta / Elteck or equivalent
Supply Only new heating element suitable to existing model and make of storage type geysers, 1.5 KW Dual clip type / triangle type / round type with rubber gasket suitable for geysers up to 25 / 50 Ltr capacity Complete all as specified and as directed.. Make: Theeta / Elteck or equivalent
Supply Only thermostat clip type (Range 30o C to 80o C and acting at 70o C) for geysers up to 50 Ltrs Complete all as specified and as directed. Make: Elcon or equivalent
Supply Only 15mm bore PVC connections with brass nuts 600mm in length suitable to connect GI pipe 15 mm dia to hot / cold water outlet of geyser Complete all as specified and as directed. Make: Kohinoor or eqivalent
Supply Only 15mm bore PVC connections with brass nuts 650mm in length suitable to connect GI pipe 15 mm dia to hot / cold water outlet of geyser Complete all as specified and as directed. Make: Kohinoor or eqivalent
Supply Only pressure release valves suitable for geyser upto 50 litres capacity type as per existing pressure valve Complete all as specified and as directed.
Supply and Fixing Indicating lamps green / red suitable for geysers upto 50 litres Complete all as specified and as directed.
Supply and Fixing FRLS PVC insulated copper flexible cable, 2.5 Sqmm, 3 core, PVC sheathed, 1100 volts grade Complete all as specified and as directed.
Taking down unserviceable plug top and Supply and Fixing new plug top 3 pin 15 amps, 230 volts Complete all as specified and as directed.
Material and labour for arresting the leakage in inner tank of geyser, any size / make complete with brazing work and leak test and servicing etc Complete all as specified and as directed.
Supply and Fixing Non return valve of size 15mm bore Complete all as specified and as directed.
GKR and CO
SREE VARU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .