Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.4 L+₹2.2 L (16.4%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L2 | Rejected-AOC L2 | |
| 3 | L3₹18.4 L+₹5.1 L (38.6%)Rejected-AOC H NO 279 SHAHEED NAGAR AGRA | AGRA | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
18 Nov 2021, 6:00 pmClosed
GE Bharatpur
Kanjoli line Bharatpur
Repair maint fo DG Sets Pump Sets Cleaning of OH tanks, UG Sumps open walls at various location of RMS Dholpur under GE Bharatpur
2021_MES_472326_2
8070/E8
Open Tender
Civil Works
Item Rate
270 days
GE Bharatpur
As per tender document
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹32,000
Yes
22 Feb 2022
25 Oct 2021
20 Nov 2021
25 Oct 2021
18 Nov 2021
3 Nov 2021
26 Oct 2021 - 27 Oct 2021
Amount
Taking out submersible pump set of capacity 40HP/30HP 3 Phase 415 volt AC supply alongwith column pipes from the bore well by disconnecting electric connection, disconnecting the motor from pump dismantling the motor & over hauling the same by repairing/ replacing defective part as ordered & re-assembling including M&L for replacing worn- out nuts bolts washers complete, connecting /coupling the motor with pump & with column pipes & lowering the same after repairing, making the connecion complete all as specified and directed. Note: Spares required to be replaced shall be measured separately as supply only.
Supply only spare parts for above 40HP submersible pump against item No 01 of existing make. 2.01 Hook bolt
Motor Bush
Rubber Bush
SS Bush
Stud with nuts & bolts
Neck Ring
Impeller
Top/Bottom bearing bush
SS Rooter sleeves
Thrust Plate
SS shaft
Bowl Bush
Diffuser CI/Steel Note:- Fixing of item No 2.01 to 2.14 shall be measured and paid under item No 01.
M&L for rewinding the submersible Motor 40HP/30HP with super enamaled copper winding wire of suitable gauge & superior class of insulation including insulation paper sleeves thimbles etc & testing.
Cleaning of RCC overhead reservoir of 75,000 GLN capacity at 18 Mtr staging including draining out water. Removing, Mud, Slit/dust from Tank. Washing & rubbing with gunny bags & cleaning with fresh water & Bleaching powder including writing the date of cleaning etc by synthetic enamal paint complete all as specified and directed. (a) All necessary ladder and scaffolding arrangement shall be made by the contractor. (b) All kind of safety equipments shall be arranged at site by the contractor. (c) In case of damage of any outlet pipeline/control valves during operation shall be borne by the contractor (d) Disturbed portion if any shall be made good as per existing by the contractor. Note:- Quoted rate shall be deemed to be inclusive of above provition.
Cleaning of Masonry /RCC under ground sump of 50000 GLN capacity, Located at Gundrai pump house No 1, including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder two times (iv) writing the date of cleaning etc by synthetic enamel paint
Cleaning of Masonry /RCC under ground sump of 25000 LTR capacity loacted at Cadets hostel area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder two times (iv) writing the date of cleaning etc by synthetic enamel paint
Cleaning of Masonry /RCC under ground sump of 25000 GLN capacity loacted at Kesarbagh Sump House area including the following works: (i) draining out water with the help of monoblock pumpset (pumpset shall be managed by the contractor) (ii) Removing, Mud, Slit/dust from sump by manually & rubbing & cleaning with gunny bags etc (iii) washing with fresh water & Bleaching powder two times (iv) writing the date of cleaning etc by synthetic enamel paint
Dismantling electric motor of centrifugal pump 3 phase for 440 volt 30 HP and rewinding of motor with super enameled copper wire of same guage & turn including material, varnishing, re-assembling, testing & commissioning /complete all as directed. Note: Spares shall be measured & paid separately for dismantling of pump set partially or complete shall be paid accordingly.
Supply only spare parts for above Centrifugal Pump of 30 HP at item No 08 of existing make. 09.01 Ball bearing SKF/NBC (6309)
Pump shaft with Key
Coupling Key
Gland Plate (Set of two)
Suction/Discharge stud/Nuts/ Bolts
Gland Bush (Gun metal)
Coupling rubberised
Foot valve 80mm GI or CI heavy grade as per existing. Note:- Fixing of item No 9.01 to 9.08 shall be measured and paid under item No 08.
M&L for rewinding the Submersible pump Motor 5HP/7.5HP with super enamaled copper winding wire of suitable guage & class of insulation including insulation paper sleeves thimbles etc & testing.
Supply & fix in repairs MCCB 125Amp Four Pole (25KA) in existing panel board.
Opening of DG set 82.5KVA water/air cooled (Kirloskar) by unscrewing nuts, bolts and servicing of DG set with checking, draining and changing of Engine oil and Coolant, checking and changing of V-belts, greasing and oiling of all relevant parts and topping up, Cleaning the inner body of Fuel tank and Radiator etc by removing sludge etc and reassembling the DG set after repair and replacement of unserviceable parts of DG set including repair of control panel, opening of alternator, water pump, starter motor for cleaning, servicing and refixing. Checking and servicing of Battery and testing complete in all respect complete all as specified and directed. Note: Spares required to be replaced shall be measured & paid separately complete all as specified and directed.
Supply only following spare parts for item No. 12 of existing make. :- 13.01 Air cleaner element
Water hoses including clamps complete all as specified.
Fuel filter element.
Lubrication oil filter
Fuel Pipe
Piston & Rings
Fan belt.
Head Gasket
RC Joint, Set of O Rings, Set of Joints
Valve Pair, Valve seal and Valve guide
Battery 150 AH (Type Flat Bed, Maintenance Free) Make :- Exide/ Amaron/ Luminous
Oil Pipes including clamps complete all as specified
coolant in one/two ltrs packing complete all as specified and directed.
Supply only distilled water in one/two ltrs packing.
Supply & filling oil of recommended grade (DF-4, 15 W 40) Make Servo or equiralent complete all as specified and directed. Note:- Fixing of item No 13.01 to 13.15 shall be measured and paid under item No 12 .
Supply and fixing of the following spare parts of FASD starters: 14.01 Contactor switch 25Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Contactor switch 40Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Contactor switch 70Amp capacity, with 380-415V coil, ML model of L&T or equivalent
Start/Stop push button toggle switch
Starter relay 415V, 40Amp or above upto existing capcity range
Multi controller/single phase preventer & timer switch relay in single box capacity ranging from 7.5HP to 40HP make L&T, cat part No CS94824D000 or equiralent make as specified in Appx 'B'
GI Foot valve 40mm heavy type
Copper lugs of size 16 to 25sqmm
Aluminium lugs of size 50 to 120sqmm
M&L for rewinding of monoblock pumpset of 3.0 to 5.0 HP installed at Cadets hostel area after dismantling all connections and transporting to workshop and replaceing spares, cutting burnt out winding and rewinding suitable copper super enamelled conductors on primary stator and re-installing at existing loaction complete set all as specified and as directed.
Supply and fixing in replacement of old unserviceable Direct Online Starter of capacity 7.5HP suitable for monoblock pumpsets installed at cadets hostel area complete set all as specified and as directed. Make L&T, cat part No SS96211 equiralent make SIEMENS ENGLISH ELECT,GE, HAVELLS INDIA LTD, ABB.
S & F in Replacement fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for 30 to 40 HP (Rating / Capacity of starter should be 1.5 times more than that of Submersible Motor pump of capacity 40HP) submersible motor pump including first filling of oil in oil chamber (If Required) and testing complete (Make : L&T, Cat Part no CS90908) equiralent make SIEMENS ENGLISH ELECT,GE, HAVELLS INDIA LTD, ABB.
S & F in Replacement fully automatic star delta starter comprising of voltmeter 0-500 V and ammeter 0-100 Amps, single phase preventor, over load relay and timer housed in single MS sheet powder coated enclosure suitable for 7.5 to 10 HP (Rating / Capacity of starter should be 1.5 times more than that of Submersible Motor pump of capacity upto 10HP) submersible motor pump including first filling of oil in oil chamber (If Required) and testing complete Make :L&T, Cat Part No SS95983 or equiralent make SIEMENS ENGLISH ELECT,GE, HAVELLS INDIA LTD, ABB.
Labour only for servicing APFC panel board and checking all the contact terminals and capacitors, repairing the terminal wire circuits, tightening all kind of nuts and bolts, screws atc, cleaning inside the chamber, enclosure etc, checking the connection of CT coil from panel to main incoming source and repairing in case of any fault in connections all as specified and as directed. Note: Replacement of Spares shall be measured and paid separately as supply only.
Supply only and testing at site of the following accessories of APFC panel: 20.01 Cylidrical series capacitors, KVAr rating 2, 440V, 3Ph, heavy duty, make L&T, cat part No LTCOH or equivalent make mention in Appx B.
Cylindrical series capacitors, KVAr rating 5, 440V, 3Ph, heavy duty, make L&T, cat part No LTCOH or equivalent
Cylidrical series capacitors, KVAr rating 10, 440V, 3Ph, heavy duty, make L&T, cat part No LTCOH or equivalent
VAF + PF meter accuracy class 1.0. 0.5, input voltage measurement range 50 - 520 VAC (P-P), Aux supply 80-300 VAC/DC, CT secondary side 1A/5A, Flush mounting 96x96, CT/PT programmable, Para meters VLL, VLN, A, F, PF, On Hrs, RPM, Apeak etc with RS485, Cl-1, Make L&T, Cat Part No WL4110110000 or equiralent make as specified in Appx 'B'
Supply and fixing in repair 40mm GI water tubing IS-1239 marked, medium grade, including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion. Note:- excavation earth work will be measured and paid saperatly.
Supply and fixing in repair 20 mm GI water tubing IS-1239 marked, medium grade, including all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed portion. Note:- excavation earth work will be measured and paid saperatly.
M & L for Painting of existing motor and pumpset centrifugal type 30HP,monoblock pumpset,mounting channels of pumpset of any size after complete removing old paint and Painting of MS sheet cover fabricated on open well No 1, 2 and 3 at Gundrai after preparation ,painting of sluice valve/NRV/Air Release valveand one x sigle coat primer and applying spray painting of two coat synthetical enamel paint of approved colour etc without disturbing anyother parts of the complete set all as specified and as directed.
M&L for providing angle iron support under the NRV at Well No 2 including, cutting, bending, fabrication, welding, and one coat anti corrosive primer and one coat synthetic enamel paint complete set all as specified and as directed.
M&L for painting of existing GI/CI pipeline of any size and type at Kesarbagh sump house, pump house No 1, 2 and 3 at Gundrai, bore well pump house at India lake, delivery pipe of UG sump monoblock pumpsets located in 6 x hostels etc after preparation of surface with sand paper and one x coat of anticorrosive primer and applying one coat synthetic enamel paint of black colour complete without damaging other partscomplete set all as specified and as directed.
M&L for replacing gland packing by dismantling Gland plate and stud, cleaning inside the packing house etc for suitable size of 150mm sluice valve, leakage testing and obtaining OK result from complete set all as specified and as directed.
M&L for greasing on motor and pumpset nipples , replacing burnt gland packing of any size and of centrifugal/monoblock pumspset of any size and capacity including leakage and damiging testing and obtaining OK result complete set all as specified and as directed.
M & L for neoprene rubber / Leather gasket minimum thickness 8mm suitable for tightening the GI flange or any othe joints of 100mm dia with nuts and bolts complete set all as specified and as directed.
Demolition of old PCC foundation any type and size including removal of anchor bolt and removing debris from site at safe place as eco friendly manner all as specified and complete set all as specified and as directed.
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) work for pumpset platform and other misc pedestal supports complete including form work etc complete set all as specified and as directed.
S & F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M & L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 400cm x 60cm x 20mm thick computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanetly, including all kind of securing, welding, assembling with proper allignment and height with fine look, PCC, cement work including stone pillar up to required hight, excavation if required, LED tube light fittings 1 x 20Watt, including connecting wires as required and switch independent one way 5Amp with well finish of weather proof suitable for exposing at all weathrs complete set all as specified and as directed.
Supply only Calcium based high strength granular Chlorination chemical water disinfectant, a white free flowing granular material which is free of Foreign materials, concentration of Chlorine content should be between 60 to 70 percentage stability, Altoch GP/Puri-chlor. complete set all as specified and as directed.
Taking out Serviciable/unserviciable GI/CPVC column pipe 40/50 mm dia x 3 mtr long both end flanged or threaded any type and stored at one place and re-installig after repairing or devolpment of bore well complete set all as specified and as directed.
M & L for Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water with the help of suitable pneumatic boring compressor at Gundrai and Kesarbagh whereever directed complete set all as specified and as directed.
Supply and fix in repairs 40 HP submersible motor at gundrai bore well all as specified and complete set all as specified and as directed. Make - Kirloshkar/KSB/CG NOTE- Contractor shall test run motor by deputing sutiable from OEM in front of engineer-in-charge till achiving satishfactory result. Note:- Old U/S motor shall be deposited in MES store yard.
Supply connect fix and test submersible cables copper conductor PVC insulated over all sheathed flat flexible complete set all as specified and as directed. ISI marked- conforming to IS-694, 1100 volts grade complete of following sizes:- 36.01. 10 sqmm 3 core
16 sqmm 3 core
M & L for dismantling existing broken valve pit complete with corroded MS sheet cover including removal of all material and construction of valve pit chamber, brick masonry all as specified in drg No TD/2004/26 sheet 1/3 to 3/3 for sluice valve including plastering, PCC in foundation excavation and earth work, MS sheet cover (3mm thick) with locking arrangement, painted with two coats of anticorrosive paint over one coat of primer of following sizes:- 37.01 1000mmx 950mm x 1000mm As per drawing No TD/2004/26 Sheet No 1/3, 2/3 & 3/3
1200 mmx 1200mmx 1000mm
Labour only to attend break down of motor pumpsets & CI/GI pumping and distribution line any size and type including excavation , taking out of pipes, valves, replacement of damaged portion, repair of pipeline leakages, including welding if required, replacement of joints/gasket/packings and all kind of water supply related complaints on daily basis as per the directions during contract period complete complete set all as specified and as directed. Note: (i) Each Breakdown in pumping line of size 50mm dia to 150mm shall be counted as one job (ii) Breakdown of any three in distribution line below the size of 50mm shall be counted as one job. (iii) Welding , jointing and refixing/addn/altn of size and length shall be included in rate. (iv) No vehicle shall be provided by the MES for conveyance of the pipe ftr and helpers.
Supply and fix in repair submersible pump set of 40HP capicity, head more than 250mtr dischage 5000LPM including mounting accessories, GI clamp, channels, rubber gasket hanging rope made up of SWR or nyion water proof rope of suitable dia etc and fabrication if andy at gundrai bore well all as specified and directed. Make- Kirloshkar/KSB/SG Note- Contractor shall be test run the pump set by deputing suitable technician from OEM in front of engineer-in-charge till achiving satisfactory result. Note:- Old U/S Pump set shall be deposited in MES store yard.
S & F new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road ay light fitting with hight power LED as source of capacity 60 watts with suitable drivers and included 10KV SPD etc and connecting with 4.0 sqmm aluminium conductor PVC insulated twin core weather proof cable etc. fixing to wall pole with and including bracket made out of GI pipe of suitable dia light grade not less than 1.5 mtr long, bent to shape, fixed to pole/ wall in any position with flat iron clamps of size 50 x 6mm including taking down old unserviceable street light fitting of any type and capacity complete set all as specified and as directed. Make:- Crompton Cat part No LSTP-60-CDL for equivalent model of Phillips/Bajaj/Havells.
Supply and fix DOL Starter of capacity 5HP suitable for three phase motors complete with on off push buttons and over current relay. Make :- Legrand/ L&T or equivalent make as specified in Appx 'B'.
Rewinding 5HP motor of lifting pumpset by using super enamelled copper conductor wire soild in nature, grade 1 quality, incl dismentling/assembling and transporting etc. and reflxing after repairing and replacing of UNSV parts such as housing/nuts bolts etc
Excavation in trenches in any type of soil n.exc 1.5 M wide and n.exc 1.5 M in depth for taking out / laying of pipe lines and getting out forming bottom surfaces to required gradients complete all as specified and as directed.
Returning, filling in and including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed
Removing excavated surplus materials to a distance not exceeding 50 Mtrs and deposited where directed at a level not exceeding 1.5 Mtr .Above starting point complete all as specified and directed.
M&L for rewinding and repair of burnt out 0.5HP pump from the mounting of lower tank incl transporting to workshop, transporting back to its original location and mounting, refitting, testing etc complete set all as specified and as directed. Note:- Rate including replacement of all kind of spare parts such as ball bearing, impeller housing, diffuser, valute casing and delivery assembly, suction assembly, all kind of the works deemed to be including in each job
PD GUPTA AND COMPANY
abhinav and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .