| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | ₹13.7 L Quoted ₹14.5 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹18.0 L+₹3.5 L (24.2%)Rejected-Finance KHASRA NO 145 GROUND FLOOR NEAR JAIN MOHALLA JATO KI CHOPAL VILLAGE KHERA KALAN NEW DELHI 110082 | NORTH | DELHI | 110082 | ₹18.0 L+₹3.5 L (24.2%) | L2 | Rejected-Finance BEING NOT LOWEST |
| 3 | L3₹18.5 L+₹4.0 L (27.6%)Rejected-Finance RZF 498 MG MARG RAJ NAGAR II PALAM DELHI CANTT 110077 | NEW DELHI | DELHI | 110077 | ₹18.5 L+₹4.0 L (27.6%) | L3 | Rejected-Finance BEING NOT LOWEST |
| 4 | L4₹19.1 L+₹4.6 L (32.0%)Rejected-Finance H NO 31 DUPLEX MOTIAZ ROYAL FAME VILL CHAJJA MAJRA PO LANDRAN SEC 117 DISTT SAS NAGAR MOHALI PB PIN 140307 | S A S NAGAR | PUNJAB | 140307 | ₹19.1 L+₹4.6 L (32.0%) | L4 | Rejected-Finance BEING NOT LOWEST |
| 5 | L5₹21.4 L+₹7.0 L (48.2%)Rejected-Finance VILLAGE PO KOTHI TEH KALPA DISTT KINNAUR HP 172107 | KINNAUR | HIMACHAL PRADESH | 172107 | ₹21.4 L+₹7.0 L (48.2%) | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Apr 2024, 6:00 pmClosed
GE 863 EWS
GE 863 EWS C/O 56 APO
REPAIR MAINTENANCE OF EXTERNAL ELECTRIC SYSTEM LT PANELS AND OTHER CONNECTED WORKS AT KARCHAM AND POARI IN THE AREA OF AGE EM WE POOH UNDER GE 863 EWS
2024_MES_648206_1
GE 863/EWS-T-85 OF 2023-24REPAIR MAINTENANCE OF EXTERNAL ELECTRIC SYSTEM LT PANELS AND OTHER CONN
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KARCHAM, POARI AND POOH
AS PER NIT
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹40,000
Yes
27 Jun 2024
28 Mar 2024
26 Apr 2024
28 Mar 2024
19 Apr 2024
10 Apr 2024
28 Mar 2024 - 17 Apr 2024
Amount
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep and getting out in hard/dense soil for laying/jointing kit/repair of cable and erection of poles, complete, all as specified and directed
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm thick each layer in hard/dense soil,complete, all as specified and directed
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point, complete, all as specified and directed
M & L for Sand cushioning on under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable, complete, all as specified and directed
Supply and lay well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete, all as specified and directed
Supply and laying in replacement of GI pipe light grade 80mm bore, galvanized with all fittings laid in trenches for cable protection , complete, all as specified and directed
Supply and laying in replacement of GI pipe light grade 50mm bore, galvanized with all fittings laid in trenches for cable protection , complete, all as specified and directed
Taking out faulty U/G cable of any size by removing PCC covers or bricks of any specification for replacing the same with new LT U/G cable, complete, all specified and as directed
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 120 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 95 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 50 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 35 sqmm , 3.5 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 25 sqmm , 04 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 16 sqmm , 04 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 10 sqmm , 02 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
Supplying, laying in trenches /passing through tubing/pipes or laid under floors or through walls/ducts etc , jointing and testing , Low Tension,1100 Volts grade XLPE insulated, screened PVC bedded , galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminum conductor, cross sectional area 06 sqmm , 02 core, including both sides connection with and including cable lugs etc., complete all as specified and directed.
M&L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with topedge of the plate not less than 1.5m below normal ground level connected to GI earth strip 25x4 mm dia up to 7.5 meter from earth pit, protected by GI pipe light grade 40mm dia, 20 mm medium grade for watering with funnel , common salt, charcoal dust and connected to panel board by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 5 of SSR part I including necessary earth work and excavation in any type of soil, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type mix cover slab with 6mm dia MS bars at 100mm dia both ways with MS hook 6mm dia MS bars etc complete all as specified and directed.
Supply, fix in replacement of MCCB, 400 Amps, 4 Pole, 415 V, Adjustable type with breaking capacity 36 KA with spreader links,etc complete all as specified and directed.
Supply, fix in replacement of On load Change over 100 Amps, 4 Pole 415 V,etc complete all as specified and directed
Supply, fix in replacement of MCCB, 250 Amps, 4 Pole, 415 V, Adjustable type with breaking capacity 36 KA with spreader links,etc complete all as specified and directed.
Supply, fix in replacement of MCCB, 200 Amps, 4 Pole, 415 V, Adjustable type with breaking capacity 36 KA with spreader links,etc complete all as specified and directed.
Supply, fix and testing in replacement of MCCB 160 Amps, 4 Pole 415 V, Adjustable type with breaking capacity 25 KA with spreader links,etc complete, all as specified and directed.
Supply, fix and testing in replacement of MCCB 100 Amps, 4 Pole 415 V, Fixed type with breaking capacity 25 KA with spreader links,etc complete, all as specified and directed.
Supply, fix and testing in replacement of MCCB 63 Amps, 4 Pole 415 V, Fixed type with breaking capacity 16 KA with spreader links,etc complete, all as specified and directed.
Supply and errection in replacement of steel tubular swaged pole ,09 M long, type 410-SP-31, complete with CI base plate, finial taper plug, bolts, nuts and screws etc including, complete, all as specified and directed Note : Necessary excavation and earth work, PCC foundation, coping, disposal of surplus soil, Painting inside with black bitumen paint and out side shall be measured and paid separately on relevant items of Sch 'A'
Restringing only ACSR conductor of any type/ size on existing LT poles, etc including binding on to insulators with and including aluminium wire, complete, all as specified and directed .
M&L in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts, washers, welding , bending cold or hot or hot drilling holes for bolts, washers in any shape or size as indicated or directed incl one primer coat, one under coat & one finishing coat, complete, all as specified and directed
Supply, fixing and stringing in replacement of ACSR conductor of any type/ size on existing LT poles, etc including binding on to insulators with and including aluminium wire, complete, all as specified and directed.
S & F in replacement of pin type, porcelain vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height, 65mm dia for 1100 Volts grade, complete, all as specified and directed.
S & F in replacement of shackle type porecelain vitreous white brown or green insulator for working pressure 1100 volts of 90mm dia and 75mm height incl galvanised steel straps of 31x3 mm size, insulator bolt 12 mm dia,washer & nuts, complete, all as specified and directed.
S & F in replacement of PVC line phase separators for over head line LT conductor of any size suitable to withstand 1100 volts to maintain the required spacing between 5 conductors, complete, all as per site requirement and all as directed
S & F in replacement of Stay assembly Diameter of stay rod of not less than 20 mm, 215cm long with threaded end with suitable size of nuts & washers complete with accessories including staybows with nut bolt & washer of 14mm dia, 40cm long and stay grips & thimble of suitable size as shown in electrical plate No. 1 SSR Part-I, complete, all as specified and directed. Note:(i) Rate are deemed to be inclusive of streching, tieing and tightening of stay assembly for poles including tieing frame for stay wire. (ii) Exacavation, returning filling, removal for stay wire assembly upto 2.5 mtrs including Ropes are deemed to be included in quoted rates. (iii) Ladders of any size,T&P (any type), Labour Safety equipments as required at site for working on PCC pole of 9Mtrs height is deemed to be inclusive of quoted rates. (iv) Stay clamp/stay wire will be measured & paid saperately.
M&L in replacement Loop type insulator, vitreous porcelain, white, brown or green of Large size, with overall dimensions 140mm, clearance of hole 25.5mm, including nut bolts & washers of suitable length and thickness, complete, all as specified and directed.
M&L in repair galvanised stay wire 7/4mm for stay assembly to be fixed between stay assembly and stay clamp on PCC/MS steel pole, complete, all as specified and directed.
M & L for Plain cement concrete (1:2:4) type B1 using 20mm well graded stone aggregate as in pedestal / coping of pole and in Road cuttings including form work If necessary,complete, all as specified and directed.
M & L for PCC 1:3:6 type C2 (using 40mm well graded stone aggregate) in foundation, filling and mass concrete,complete, all as specified and directed.
M & L for Aluminium painting to Steel tubular Street light pole for 5.5 mtr from top towards bottom and next 0.45 mtr Navy Blue and next 1.10 mtr white and 0.45 mtr Synthetic enameld paint yellow & black colour (Tiger cross) on Coping and writing pole No with white paint inside of black circle above the Navy blue painting and aluminium painting to GI bracket / pipe etc.and sticking of reflector stricker red in colour on the Poles at the height of 1.5 metre above the copping, complete, all as specified and as directed.
Supply and fixing in replacement of Busbar chamber 100 Amp with suitable thickness aluminium busbars, 4 way, 415 volts, 50 Hz, Wall mounted type incliuding suitable fastners, etc complete all as specified and directed Make : Indoasian/Havells/L&T/Standard
M&L for taking proper shut down and servicing the LT panel board of any type ( indoor/Out door) make complete with removal of dust reconnection of all incoming and outgoing cable with proper gland replacemnet of all nut, bolts and washers, repalcement of control wiring including insulation tapping with colour coding replacement of burned aluminium bus bars, fixing of LT panel front and back door covers on hinges complete with cutting, welding, grinding etc and providing porper locking arrangements etc all as speciified and directed by Engineer in - charge. Note : (a) Cost for replacement of minor spares like thimble, porcelain unsulator, busbar sleeve, cable sleeve, etc are deemed to be included in the quoted rates. (b) The rates shall be deemed to be included for replacement of worn out rusted, Channels, hinges, bolts, split pins and cable lugs, cable glands and neoprene gasket to all doors including raising of foundation to 300cm height etc.
M&L for Painting LT panel of any type or size with two coats of synthetic enamelled grey paint with brush of suitable size including preparation of old painted surface after taking shut down of that panel complete all as specified and as directed.
M&L for any type of road cutting upto 300mm deep & 300mm wide for laying GI pipe for protection cable complete all as specified and as directed.
Net Contract Sum will be after deducting Sch Of Credit of Rs.74108.75.00
chankaya solutions
MRITUNJYA ASSOCIATES
Dharm Singh Contractor
M/S Gopal Singh
SANTOSH KUMAR
M/S Shamsher Negi Dewa
M/S Gulab Singh
PRITPAL SINGH
M/S SHIV NATH ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .