Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC WZ 88A JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹10.4 L+₹2.8 L (36.2%)Rejected-Finance | L2 | Rejected-Finance Rejected |
Tender Value
₹11 L
EMD Value
₹22,000
Closing Date
31 Aug 2022, 6:00 pmClosed
GE AF Subroto Park
GE AF Subroto Park c o 56 APO
REPAIR AND MAINTENANCE OF GEYSERS AND SOLAR WATER HEATER AND OTHER CONNECTED WORK IN THE AREA OF WAC (U) AND CAMERO UNDER GE (AF) SUBROTO PARK
2022_MES_543672_1
GE/SP/ TOKEN-33/2022-23
Open Tender
Civil Works
Item Rate
180 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE AF Subroto Park
₹22,000
Yes
13 Oct 2022
5 Aug 2022
7 Sept 2022
5 Aug 2022
31 Aug 2022
19 Aug 2022
Amount
Supply & fixing in replacement the following unserviceable spare parts for Water Storage Heater (Geyser) of capacity 25/50 Ltrs of any make & model installing inside of Subroto park and rectifying all the defects as mounted and fitted on wall with nut & bolts and re-fixing to its original postion after repair and making geyser satisfactory functional complete all as specified and directed by Engineer-in-charge (a) Geyser assembly including rubber seal,screw as per existing model
(b) Heating element 2000 watt 240 volts AC including seal, washers
(c) Heating element 1500 watt 240 volts AC including seal, washers
(d) Steel tank 50 ltrs as per existing model
(e) Steel tank 25 ltrs as per existing model
(f) Copper tank 50 ltrs as per existing model
(g) Copper tank 25 ltrs as per existing model
(h) MS Sheet bottom cover in two pieces duly painted with 2 coats of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete.
((i) MS sheet top cover in two pieces duly painted with 2 coat of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete.
(j) MS Sheet outer cover duly painted with 2 coat of synthetic enamel paint over one coat of primer suitable for 50 /25 ltrs capacity as per existing model complete.
(k) Thermostate (temperature control device) for 25/50 ltrs capacity geysers.
(l) Indicating lamp with cable(Red/Green) for 25/50 ltrs capacity geysers as per existing model complete.
(m) 3 core flexible copper cable of size 2.5 sq mm 1100 V grade.
(n) 3 core flexible copper cable of size 4 sq mm.
(o) Metal clad plug top 20/25 amps 230 Volt, Single Phase.
(p) Metal clad socket 20/25 amps 230 Volt, Single Phase.
(q) Single pole and neutral enclosure with a two pin and earth plug and socket 240 V complete with one single pole MCB 20 amps.
(r) MCB SP 6-32 amps 230 Volt c series 50 Hz Single Phase.
(s) Socket outlet 3 pin 16 amps piano type 230 V flush type.
(t) Switch piano type 16 amps 230 V single pole.
(u) PVC plug top 3 pin 16 amps suitable for 230 volts AC supply.
(v) PVC gang box suitable for one switch /socket 16 Amps complete with screw and necessary arrangement complete all as specified and directed by Engr-in-charge.
(w) 450 mm long flexible hot water connection pipe with two Nos union suitable for 15mm bore iron pipe complete all as specified and directed by Engr-in-charge .
(x) 600 mm long flexible hot water connection pipe with two Nos union suitable for 15mm bore iron pipe complete all as specified and directed by Engr-in-charge.
(y) Pressure release valve brass chromium plated screw with 15mm bore iron pipe and suitable for 50/25 ltrs geyser complete all as specified and as directed by Engineer-in-charge
(z) Safety valve brass of cast alloy of screw with 15mm bore iron pipe & suitable for 50/25 ltrs geyser complete all as directed.
(aa) New glass wool as per existing density for geyser of any capacity make & model complete all as specified and directed by Engineer-in-charge.
(ab) 15mm bore non-return valve of brass chromium plated connected to iron pipe or other fittings complete all as specified and as directed by Engineer-in-charge Notes for Srl Item No 1 to 28 (a) Contractor will provide well experienced and well conversed men power against these items including Sunday & Holidays from 0900 to 1700 hrs . (b) Electrician should be 10th passed having 4 year experience in the trade or ITI holder in the relevant trade having proper knowledge for repairing work of geyser items.(c) All T&P required for repair work shall be provided by contractor at own arrangement to trade men & helpers (d) All complaints should be attended with in 24 hours. Panelty charges for non attending complaints within 24 hours shall be Rs. 500/- per day. The cost of man power shall be deemed to be included in the unit rate of respective items. (b) Contractor shall submit the attendance register and documents of said man power duly verified by Engr-in-charge at the time of payment.
M&L for Removing existing paint from the steel surface of geyser of 50/25 ltrs capacity and applying two coats of synthteic enamel spray paint complete all as specified and as directed by Engineer-in-charge.
M & L in replacement for 15mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M & L in replacement for 20mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M & L in replacement for 25mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M & L in replacement for 32mm bore Medium grade GI tubing with all fittings and fixed complete to walls and ceilings or laid in floors including MS clamps / raddling complete all as specified and as directed.
M&L in replacement Sub main wiring complete with non metallic rigid PVC insulated fire retardent grade unsheathed 1100 volts grade multistranded copper conductor cable 2 run of 4 sqmm single core conforming to IS-694 with copper conductor drawn through and including suitable dia PVC conduit, conduit fittings and accessories concealed in walls, roofs and floors alongwith 1 run of 4 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor. Note :- 3 runs 4 sqmm cable incld PVC conduit shall be measured as one unith length.
S&F in replacement to hose pipe for solar panel to hot water tank as per dia and thickness suitable for solar heating system of cap 200/300/400/500 LPD by clamping/tightening properly for leak proof joint complete all as specified and directed
M&L for repairing of the leakage of solar hot water tank of capacity 200/300/400/500 LPD by taking down removing insulation carefully complete and taking to workshop for necessary repair by soldering /welding including replacementhing density (48kg/m3) and K value 0.03W/mk to witn stand temp. upto 250 degree celcius and insulation materials injected of thickness 100mm and refixing of its original position for satisfactory functioning of the unit complete all as specified and directed.
S&F in Repalacment of self priming monoblock pump set of cap. 0.5 HP single phase 220 Volts. +/_ 6% speed 2780 RPM complete.
S&F in Repalacment of broken/rusted steel hot water SS(20 SWG)tank (inner and outer tanks)of capacity suitable for 200 LPD solar water heater including high density (48 kg/M3 ) and K value 0.03 W/mK to with stand temp. upto 250 degree celcius and insulation material injected PUF insulation of thickness 100 mm complete all as specified and as directed by Engr-in-Charge.
All as per item No. 39 here in above but suitable for capacity 300 LPD
All as per item No.39 here in above but suitable for capacity 400 LPD
All as per item No. 39 here in above but suitable for capacity 500 LPD
S&F in replacement triple layers rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) with capacity 1000 litres for make up water of solar water heater complete all as specified and directed .
S & laying in replacement triple layer Hot water pipe duly (GI) insulated with glass wool and aluminium clading 15mm bore with connected accessories complete all as specified and directed
S & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 20mm bore with connected accessories complete all as specified and directed
S & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 25mm bore with connected accessories complete all as specified and directed
S & laying in replacement Hot water pipe duly (GI) insulated with glass wool and aluminium clading 32mm bore with connected accessories complete all as specified and directed
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 32mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 25mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 20mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal gate valve with iron wheel head screwed both ends for iron pipe and fixed for 15mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement Gun Metal angle valve with screwed both ends for iron pipe and fixed for 15mm bore pipe with connected accessories complete all as specified and directed.
S&F in replacement NRV 32mm dia made out of brass complete all as specified and as directed by Engineer-in-charge.
S&F in replacement MS dead flange for plate collector of solar water heater panels as per existing size with gasket along with connected accessories complete all as directed
S&F in replacement gasket for flate plate collector of solar water heater as per existing size along with connected accessories complete all as directed.
S&F in replacement float valve for 15mm dia along with connected accessories complete all as directed
M&L for rewinding of blower motor single phase 230 V of air curtain of any make,door opening size and air velocity with super enamelled copper winding wire including replacement of bushes, testing for noise free operation and refixing at its existing location complete all as specified and as directed.
S&F in replacement of blower unit/aluminium alloy fans as per existing for air curtain any make,door opening size and air velocity complete all as specified and directed .
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 32mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of Aluminium foil of thickness 26 SWG on the distribution GI pipe lines of 25mm bore size including all fixing accessories etc complete all as specified and as directed by Engineer-in-charge
S&F in replacement of toughened glass 6mm thick suitable for existing solar flat plate collector of any size complete all as specified and as directed by Engineer-in-charge
M&L for point wiring complete with 2.5 sqmm single core PVC insulated unsheathed cable 100 volts grade FRLS IS-694 multi stranded copper drawn through and including non metallic rigid PVC conduit fittings not less than 20mm dia and conduit accessories concealed in walls roofs and floors etc including terminal boxes fabricated with 1.6mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3mm thick fixed with cadmium plated iron screw for housing the switch socket outlet 3 pin 15 amps and including provn of 2.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continity conductor and connection to common earth dolly complete incld taking down old u/s.
Dismantling,shifting of water storage heater of any make & model from one location to another location and refixing the unit with gutties/fasteners, cutting wall/concrete incl arrangement of required T&P, fixing of extra pvc flexible multistranded copper conductor of suitable size, connection of hot water pipe and GI piping and making good distributed surface all as specified and directed by Engineer-in-Charge
M&L for comprehensive maintenance of existing solar flat plate of cap 200/300/400/500 LPD collector of indirect heating system comprising of inspection descaling brushing and cleaning of collector panel riser tubes header tubes heat absorber tubes connecting pipes and examining of water tightness of the same after acid wash cleaning and descaling and repairing of leakage if any using welding / brazing, drain out the water from panel and tank repeating two to three times to get dirty water out etc complete all as specified and as directed by Engineer-in-charge. NOTE : - Servicing of solar water heater shall be carried once in every two months. All the comprehensive maintenance work will be carried out through original authorized manufacturer of collector panel of solar water heating system only
S&F in replacement to unsv heating element of cap 3 KW suitable for solar water heater system of cap 200/300/400/500 LPD as per existing.
S&F in replacement to unsv thermostate suitable for solar water heater system of cap 200/300/400/500 LPD as per existing.
M&L for Painting of steel surfaces of solar water heater system incl tank, frames etc with two coats of super enameled synthetic spray paint over a coat of primer after preperation of old surface and making good complete all as specified and directed.
NAVYUG VYAPARI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .