Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.2 Cr+₹20.2 L (10.2%)Rejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹2.2 Cr+₹20.2 L (10.2%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹2.2 Cr+₹20.4 L (10.4%)Rejected-Finance CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹2.2 Cr+₹20.4 L (10.4%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹2.3 Cr+₹32.0 L (16.3%)Rejected-Finance 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹2.3 Cr+₹32.0 L (16.3%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹2.5 Cr+₹55.4 L (28.2%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹2.5 Cr+₹55.4 L (28.2%) | L5 | Rejected-Finance Not lowest |
| Sl No | Description | Qty | Unit | SHRI GANESH ENTERPRISES L1 | GEPS PROJECTS L4 | Sant Construction Co. L6 | R D Bansal L5 | Shree Ayyappa Engineering L7 | BHARAT ELECTRICAL TRADERS L3 | MAHESH KUMAR SINGLA CONTRACTOR L9 | SAGGI ELECTRIC COMPANY L2 | saradhi construction combines L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Disconnecting the electric supply, removing the HT and LT cable connections of the defective Power transformer, 132/11 KV of 8000KVA capacity, outdoor type, any make, taking down from platform with the help of crane suitable for lifting upto 50Ton or using lifting jacks, loading into low bed trailer of minimum 50 Ton load capacity and transporting the same carefully to MES store yard for necessary auction purpose, taking all necessary precautions to avoid possible damage during transit complete all as specified and as directed.
Note : Hire charge for heavy duty crane, hydra and Trailer, charges for loading / unloading and transportation are deemed to be included in quoted rate. Any damage to the transformer by the contractor during dismantling, transporting shall be made good without any extra cost to government. Decision of Accepting Officer shall be final and binding. | 1 | EACH JOB | 3,00,000 ₹3,00,000 | 1,50,000 ₹1,50,000 | 2,50,000 ₹2,50,000 | 85,000 ₹85,000 | 4,00,000 ₹4,00,000 | 50,000 ₹50,000 Lowest | 1,49,999 ₹1,49,999 | 2,43,000 ₹2,43,000 | 5,00,000 ₹5,00,000 |
| 2.00 | Supply, installation, testing and commissioning of Power transformer for 132/11 KV SYSTEM AT MRS Power Transformer step down, outdoor type of capacity 8.0 MVA (8000KVA) 132 KV/11 KV, 3 phase, 50cycles AC with On Load Tap Changing arrangements with remote control panel operation) on 132 KV sides to vary secondary voltage from +5% to (-) 15% in steps of 1.25% (16 steps/17 Position), impedance 8.35% at normal / common tap No 7 including suitable marshalling box and HV terminals 3 Nos outdoor bare bushings with sockets and LV terminals connectors to connect the transformer with HT XLPE Power cable of size 300 sqmm x 3 core with copper conductor and LV additional Neutral with one number solid porcelain type out door bushings with sockets on the transformer lid for earthing purpose complete in all respects with standard accessories and fittings conforming to IS-2026 primary side delta and secondary side star complete all as specified and as directed. The salient features of the transformer shall be as below: - | 1 | EACH JOB | 1,90,00,000 ₹1,90,00,000 Lowest | 2,25,00,000 ₹2,25,00,000 | 2,50,00,000 ₹2,50,00,000 | 2,47,00,000 ₹2,47,00,000 | 2,50,00,000 ₹2,50,00,000 | 2,14,00,000 ₹2,14,00,000 | 2,72,58,500 ₹2,72,58,500 | 2,08,78,560 ₹2,08,78,560 | 2,49,00,000 ₹2,49,00,000 |
| 2.01(i) Transformer shall be DYN 11 vector group oil immersed naturally cooled, doubled wound electrolytic copper winding core type, Radiator cooled MS tank complete with first fill of transformer oil as per IS-335 with ONAN cooling system. The temperature of oil shall not rise 55 degree centigrade of winding. Transformer shall be painted with two coats of synthetic enamel paint. (ii) Rating and diagram plate. (iii) Earthing terminals - 2 Nos. (iv) Lifting lugs. (v) Thermometer pocket. (vi) Air release hole with plug. (vii) Oil filling hole with plug on & incl. conservator with drain valve and plug. (viii) Plain type oil indicator on one side of conservator with minimum and maximum oil level marking. (ix) Dehydrating breather - 01 No (x) Oil conservator with drawn valve and plug. (xi) Sampling valves, top and bottom. (xii) Under base with flat treaded bi-directional rollers. | ||||||||||||
| 2.02(xiii) Drain cum bottom filter valve with plug. (xiv) Top filter valve with plug. (xv) Explosion vent with diaphragm and equalizer pipe (pressure release device). (xvi) Jacking lugs and hauling holes. (xvii) Inspection cover. (xviii) Detachable radiators with shut off valves between radiators and tanks. (xix) Radiator with air release hole and plug. Oil drain hole with plug and lifting eye all as per manufacturer's standards. (xx) 150mm dia oil temperature indicator stem type with SCADA compatability. (xxi) Double float Bucholtz relay with two sets of contacts and isolating valves. (xxii) 150mm dia winding temperature indicator with maximum indicating pointer and resetting device with SCADA compatability. (xxiii) 100mm dia magnetic oil level gauge with low level alarm. | ||||||||||||
| 2.03(xxiv) Terminal arrangements. (xxv) Suitable wheels (width distance should be as per Broad Gauge rails). (xxvi) Marshalling box. (xxvii) Neutral Grounding Resister suitable for 8.0 MVA transformer in out door floor mounted enclosure suitable for 45 Degree centigrade Ambient temperature and temperature rise 300 Degree centigrade all as approved by GE. (xxviii) Indoor type Remote Tap Changer Panel (RTCC) with Automatic Voltage regulator and necessary indications. (b) On Load Tap Changer (OLTC), out door design weather proof, oil immersed, high speed, non inductive transition type employing, snap switches combining both selector and diverter duties housed in a self contained single compartment and mounting externally on transformer at suitable place. On load tap changer shall have following components: - | ||||||||||||
| 2.04(i) High torque electric motor suitable for 450V 3 phase 50 cycles AC supply including connected cabling. (ii) Motor drive and energy accumulator. (iii) Motor isolating device with over load protection. (iv) Raise, lower control for local operation. (v) Local / remote control selector switch. (vi) Raise / low limit switch. (vii) Retainer switch. (viii) Stepping Relay. (ix) Anti - condensation heater with switch. (x) Inter locking between manual and electric operation. (xi) Main isolating switch with set of fuses. (xii) Insulated terminal board (with connector) for transformer tap leads. (xiii) Mechanical tap position indicator with handle. (xiv) Tap changing operation counter, (xv) Rating plate. (xvi) Driving mechanism chamber locking arrangement. (xvii) Un-drilled gland plate for cable entry. (xviii) Terminal strips. | ||||||||||||
| 2.05(xix) Drain cum filter valves. (xx) Hormonic filter for 3, 5, 7th harmonics with K factor for 8 MVA transformer (xxi) Suitable size of Neutral CT shall be provided (xxii) Provision of connection for moisture sensor,H2 Gas sensor and NIFPS (Nitrogen Injected Fire Protection System) shall be provided. (xxiii) OSR (Oil Surge Relay for OLTC protection). (xxiv) Ladder for climbing top of the transformer. NOTE: (a) Single limb IMPULSE TEST AND HEAT RUN TEST shall be carried out at Manufacturers factory or approved laboratory and the rate for the same is deemed to be included in the quoted rate. (b) Transformer shall be inspected by inspecting officers nominated by Chief Engineer R&D at manufacturers factory and all test pertaining to IS: 2026 shall be carried out. | ||||||||||||
| 2.06(c) Site testing: Insulation resistance, oil temperature alarm trip, Winding temperature alarm and trip, Bucholtz relay alarm and trip, Low oil level alarm, testing of annunciation systems by auxiliary relay tripping of transformer, Polarity marking and phase sequence, Ratio test, dielectric strength and filtration if required should be carried out. (d) Control cables and Bus -duct shall be measured and paid separately. (e) Foundation and civil works as per manufacture's recommendation. | ||||||||||||
| 3.00 | M & L for Earthing complete with Copper earth plate electrode 600mm x 600mm x 3.15mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to copper earth strip 50 x 6mm, copper earth strip shall be protected by suitable dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate filling of soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 50mm thick RCC cover (1:2:4) type B1 mix with 8mm dia nominal reinforcement @ 75mm c/c both ways etc complete all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point, including testing on completion, complete all as specified and as directed. | 2 | EACH SET | 50,000 ₹1,00,000 | 36,000 ₹72,000 | 65,000 ₹1,30,000 | 58,000 ₹1,16,000 | 38,500 ₹77,000 | 30,000 ₹60,000 Lowest | 35,000 ₹70,000 | 72,090 ₹1,44,180 | 80,000 ₹1,60,000 |
| 3.01NOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. Copper earth strip above 7.5m will be measured and paid seperately | ||||||||||||
Tender Value
₹2.9 Cr
EMD Value
₹3.7 L
Closing Date
7 Apr 2026, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
SPECIAL REPAIRS REPLACEMENT OF POWER TRANSFORMER 132 11 KV 8 MVA CAPACITY AGAINST BER AT MRS, RCI, HYDERABAD UNDER GE I RND RCI HYDERABAD
2026_MES_755795_1
84051
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RCI Hyderabad
Class B
category b(iii)
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER I RND RCI HYDERABAD
₹3.7 L
Yes
12 Jun 2026
10 Mar 2026
9 Apr 2026
10 Mar 2026
7 Apr 2026
31 Mar 2026
EACH JOB
EACH JOB
EACH SET
RUNNING METRE
EACH SET
RUNNING METRE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
84051Tender.pdf
Tender Documents • 1.06 MB
BOQ_846560.xls
BOQ • 0.48 MB
84051Postponmenet.pdf
PDF • 0.24 MB
84051Postponement.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .