Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC L1 Rate Satisfactory | |
| 2 | L2₹25.5 L+₹37,540 (1.49%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-Finance Greater Than L1 | |
| 3 | L3₹27.5 L+₹2.4 L (9.47%)Rejected-Finance | L3 | Rejected-Finance Greater Than L1 | |
| 4 | L4₹38.9 L+₹13.8 L (54.9%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Greater Than L1 | |
| 5 | L5₹43.5 L+₹18.4 L (73.2%)Rejected-Finance | L5 | Rejected-Finance Greater Than L1 |
| Sl No | Description | Qty | Unit | Shree Ayyappa Engineering L2 | M/s S.D Construction Co L4 | tulsani associates L1 | Shining Star Electricals L5 | PREETI ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Receiving complaints daily basis from JE incharge lodged by the user/occupaints of security/street light/ concern external electrical supply nature, rectification of the fault as over detailed by JE inchagre/ AGE E/M to rectify the fault with regard to complaints lodged and refexing of fitting and fixture to there original position as desmentled complete as as directed at site to the entire satisfaction of Engineer-in-Charge.
Note : (i) Any complaint which is left out/unattendent 1 to 2 days by the electrician by any reason. (ii) Rate quoted shall be deemed to include the cost of minor spares not cattered for in the subject CA (such as bracket, clamp, nut, bolt, led light with connecting accesseries etc) (iii) New material/ stores provided for completeing the job shall be majored and paid for separately under relevent item of sch 'A' at supply issue resolve such as cable loose/ disconect connection complaint deemed including this rate. (iv) contractor shall provided the all type of T&P Veh, ladder and safety items such as electric proof shoes and hand gloves, body harness to electrican for attending and rectification the internal/ external electric complaint (v) contractor shall provided the complaint regester and complant slip serially numbered in duplicate as per sample. The rate of such items included in this item (vi) Any un-attended complaints not done in specified time limit. the contractor shall penalty Rs. 500/- on each complaints per day. | 800 | Each complaints | 80 ₹64,000 Lowest | 100 ₹80,000 | 80 ₹64,000 Lowest | 500 ₹4,00,000 | 100 ₹80,000 |
| 2.00 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m in depth and getting out in hard/dense soil for laying of cable trenches all as specified and directed by Engineer-in-Charge. | 150 | CUM | 300 ₹45,000 | 250 ₹37,500 | 270 ₹40,500 | 200 ₹30,000 | 100 ₹15,000 Lowest |
| 3.00 | All as per item No.2 here-in-before but in hard dense soil | 30 | CUM | 400 ₹12,000 | 350 ₹10,500 | 320 ₹9,600 | 200 ₹6,000 | 150 ₹4,500 Lowest |
| 4.00 | Returning filling in, including spreading, levelling, watering and well ramming in layer not exc 25cm all as specified by Engineer-in-Charge. | 100 | CUM | 50 ₹5,000 | 50 ₹5,000 | 40 ₹4,000 | 200 ₹20,000 | 30 ₹3,000 Lowest |
| 5.00 | Removal of surplus soil (excavated soil) to distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point and all specified by Engineer-in-Charge. | 30 | CUM | 100 ₹3,000 | 200 ₹6,000 | 60 ₹1,800 | 200 ₹6,000 | 45 ₹1,350 Lowest |
| 6.00 | M&L for providing dry river sand / crush stone dust for cushioning to UG cable including punning down of sand in layers all as specified.
Note :- Cushioning will be measured and paid after punning down. | 50 | CUM | 1,500 ₹75,000 | 1,450 ₹72,500 | 850 ₹42,500 Lowest | 2,000 ₹1,00,000 | 1,000 ₹50,000 |
| 7.00 | Supply and laying factory cast, unreinforced precast concrete cable cover factory made embossed the mark “LT CABLE” class LV type1 flat size 250x150x40 mm laid in trenches as specified and as directed by Engineer-in-Charge. | 3,000 | Each | 26 ₹78,000 | 24 ₹72,000 | 19 ₹57,000 Lowest | 35 ₹1,05,000 | 25 ₹75,000 |
| 8.00 | Supply laying and testing cable XLPE insulated screened PVC beded,galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 50 sq mm 3.5 core. Including taking down old unserviceable cable any size by dismantling of all electrical connection etc all as specified and diercted by Engineer-in-Charge. | 100 | RM | 400 ₹40,000 | 500 ₹50,000 | 396 ₹39,600 | 300 ₹30,000 Lowest | 390 ₹39,000 |
| 9.00 | All as per item No 8 here-in-before but of size 25 sq mm 4 core. | 350 | RM | 258 ₹90,300 | 300 ₹1,05,000 | 257 ₹89,950 | 200 ₹70,000 Lowest | 300 ₹1,05,000 |
| 10.00 | All as per item No 8 here-in-before but of size 16 sq mm 4 core. | 250 | RM | 200 ₹50,000 | 275 ₹68,750 | 196 ₹49,000 | 150 ₹37,500 Lowest | 195 ₹48,750 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Aug 2025, 6:00 pmClosed
Gaurav Tiwari, IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REP MAINT OF STREET LIGHT TIMERS POLES LT UG CABLE CABLE JOINT SEARCH LIGHTS HIGH MAST LIGHTS ALL TYPE FLOOD LIGHT FOCUS LIGHT AND DECORATIVE LIGHTS AND ACCESSORIES INCLUDING EARTHING AND SOLAR STREET LIGHTS SOLAR PLANT SOLAR WATER HEATER
2025_MES_719149_1
GE/LONAVLA/8334/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (NAVY) LONAVLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
₹80,000
Yes
11 Nov 2025
8 Jul 2025
8 Aug 2025
8 Jul 2025
6 Aug 2025
23 Jul 2025
8 Jul 2025 - 22 Jul 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .