Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹99.2 L+₹2.0 L (2.08%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹99.4 L+₹2.2 L (2.24%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹99.7 L+₹2.5 L (2.58%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹1.0 Cr+₹3.4 L (3.48%)Rejected-Finance PAYYOOR KOTTARATHI HOUSE POST AMAYUR KOPPAM PALAKKAD KERALA 679303 | PALAKKAD | KERALA | 679303 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
28 Nov 2020, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
CERTAIN MISC B R WORKS AND DAY TO DAY MAINTENANCE OF E M SECURITY INFRASTRUCTURE INCLUDING OTHER MISC E M WORKS AT AFS SULUR
2020_MES_391889_1
8377/E8
Open Tender
Miscellaneous Works
Item Rate
304 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹2.0 L
Yes
2 Jan 2021
2 Nov 2020
30 Nov 2020
2 Nov 2020
28 Nov 2020
23 Nov 2020
2 Nov 2020 - 21 Nov 2020
Amount
SCHEDULE A BOQ
Taking down Chowkats or frames with shutters(Without taking off shutters from the frames) not exceeding 1.5 Sq. M each complete all as specified and directed.
Taking down Chowkats or frames with shutters(Without taking off shutters from the frames) exceeding 1.5 Sq. M each but n exc 4 sq.m each complete all as specified and directed.
Resecuring without taking down chowkhats or frames (without taking off shutters from the frames) not exc 1.5 sqm each
Resecuring without taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each.
Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, se-cured with nails or brads in section area 6 sq.cm but not exc 13 sq cm including taking down exisiting one
Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling & fixing in opening as per specificatioon and drawing
5mm thick rubber beading strips of entrance doors having width exc 3CM to not exc 5CM to arrest entry insects including taking down existing one complete all as specified and as directed
150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified.
Taking down /Checking of shutters of any size iron/aluminium mongery, pelmet box, door spring etc. requiring joinery/wood work and carrying out minor repairs such as tightening of screws/nails, fixing glass panes, minor adjustment of joinery door etc., including petty repairs material like screws/nails, plug etc to make it functional complete all as specified and as directed by Engr-in-Charge. The quoted rates shall be included the following aspect:- (a) Removing damaged/unserviceable existing builders hard ware and re fixing with new one. Supply only new one of builder hard ware materials shall be measured and paid separately (b) Easing and adjusting the shutter before re-fixing if found required. (c) Finishing the window frame and shutter with two coat of enamel paint. (d) The rate for re-fixing in another building in the same camp is also included.
Note for item No 12 : (a) Replacement of unserviceable builder hard work and pelmet box will be measured and paid for separately.
(b) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate.
(c) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts for supply only items here-in-after shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Supply only wooden pelmet boxes/curtain rods in position by using rawl plugs/wooden gutties fixed with MS holder clips complete incl tightening of screws etc complete in all respect length of each pelmet n exc 2.50 mtr long
Supply only 200mm extruded aluminum alloy handles, fabricated type, anodised
Supply only aluminum handles cast type anodised 150 mm long
Supply only 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed
Supply only 40 mm dia cupboard knobs fixed with nut, screw and washer of brass polished
Supply only Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm.
Taking down shutters from the frames exceeding 1.0 Sq. M each but n exc 2 sq.m each complete all as specified and directed.
Taking down shutters exc 1 sqm but n. exc 2.0 sqm and refixing in the same location complete all as specified and as directed.
Flush shutters,30mm thick, solid core construction, with particle board core and ply wood face panels, commercial type on both sides, complete all as specified and directed.
75mm long medium weight, stainless steel, butt hinges all as specified and directed.
75mm long medium weight, stainless steel, butt hinges fixed as in repair and welded to metal frame n exc. 2.5 cm in length and n exc 6 mm of metal thickness.
30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taken down existing one complete all as specified and as directed by Engineer-in-Charge.
Easing of door shutters for easy closing/opening and tightening of hinges or changing the position of hinges, adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed by Engineer-in-Charge, Size of door upto 2 Sqm single leaf or double leaf.
Easing of window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments complete all as specified and directed by Engineer-in-Charge, size of window upto 1.5 Sqm.
Repair to ends of chajjas/ parapets by removing old concrete, loose material & cleaning of the reinforcement and finishing the surface in cement mortar 1:3 , finished fair & even and making good with existing finishes all as specified and directed. Note: Rate quoted by the tenderer shall be deemed to inclusive of double steel scaffolding and foam work.
Complete removal of existing treatment of any type/description such as distempering work, internal oil emulsion etc from internal surfaces of walls & ceiling with mechanical means/grinder, then applying one coat or more coat minimum 1 mm thick of Birla Putty on wall of internal surfaces of walls/ceilings as required for desired smoothness and levelling of surfaces by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving surface finish all as directed
Preparation of plastered or un plastered old surfaces of walls, Chajja, balcony, facia etc. by brooming down or steel wire brushing scrapping down, smoke shoots moulds, mass efforescent salt, treating oil and greasy spots ect and applying one coat of cement based paint complete all as specified and directed.
Preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
Dismantling/taking down old existing unserviceable cement plaster loose/unsound weaken cement concrete of any description and in any position from existing external/internal surfaces of wall, roof, chajja etc
M&L for cleaning and removing all corrosion scales, rust etc using emery / wire brush and finally cleaning using rust remover & cleaning agent that is one part chloride and sulphate free liquid, rust remover material with corrosion inhibitors and dispersing agents having specific gravity of 1.18 and the coverage shall be 5 – 6 m²/ L, of Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
M&L for drilling hole in RCC/Bricks structures using drilling machine up to a depth of 15 mm and 18 mm dia, removing dust, etc by vacuum cleaner and blowers, providing and fixing of heavy grade GI pipe nipple 15 mm dia, 75 mm long, @ 1.0 mtr c/c in both direction and injection cement slurry mixed with liquid integral waterproofing compound confirms to IS 2645-2003, having specific gravity 1.06 , chloride content: Nil as per IS 2645-2003 & carboxylated styrene butadiene copolymer latex concrete bonding agent and cement modifier of Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex having specific gravity of 1.01 and Cementations based plasticized grout admixture, @ 1 % by weight of cement for neat cement through nipple and closing ends Non-Shrink Fast Setting Hydraulic Cementitious Product after injecting the chemicals mixed with cement slurry complete all as specified and directed complete all as specified and directed by Engineer-in-Charge. Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
M&L for applying 15-20 mm layer by Sprinkling sand particles on the final layer of saturant making mechanical key, over which applying Single component, fiber reinforced cementitious repair mortar which is reinforced with specially designed bean shaped, thixotropic synthetic fibers for exceptional resistance to cracking for a thickness of 12mm-50mm .Cement and sand can be used for matching the surface, water ratio of which shall be 0.16, 28 days compressive strength shall be 50 MPa,mixed density shall be 2.25 kg/ltr, and tensile strength for 28 days shall be more than >4MPa. Make of product STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
M&L for applying epoxy bonding agent for proper bonding between old surface with micro-concrete/new surface and fixing shuttering around the structural members to be retrofitted. The bonding agent shall be a two component solvent free epoxy supplied as ready to use at site. The product shall have a minimum pot life of 30 Min at 35°C and . It shall develop a minimum compressive strength of 65 MPa and a bond Strength of 3 MPa. Make of epoxy bonding agent : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
M & L for curing of the surface using Concrete Curing Compound low viscosity emulsion which incorporate a special alkali reactive emulsion breaking system. It shoud be non-penetrating continuous filmcomplies with the internationally recognized ASTM C309 standards including all tools and tackels complete all as specified and directed by Engineer-in-Charge @ coverage of 7.4 - 8.6 m² /litre /coat. Product should have daylight Reflectance of 70% as per ASTM E - 1347 Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
M&L for filling blow holes and repair the cracks using cementitious crack sealer 100% solid, solvent free, high performance,non-slumping, three component consisting of an epoxy resin, hardener cracks should be opened and filled in v-groove manner.Sealer should have density of 1.64-1.68 gm/cc , comprehensive strenghth @7 days -70 - 80 MPA Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
Providing and applying 40 to 50 mm thick, corrosion resistant non-shrink free flow, cementitions one component micro-concrete like of Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex, using having compressive strength 50 Mpa at 28 Days, epoxy bonding agent of Make : STP LIMITED. having mix density of 1.1kg / Litre, compressive strength 65 N/mm2 7 days, Bond strength 3Mpa at 7days, having an over lay time of 3hrs at 30°C pouring of micro concrete into the form work using suitable arrangement or if required using pumping device for uniform flow of micro–concrete. The side shuttering can be removed after 3days and the bottom shuttering after 7 days ensuring proper bond between the micro concrete and existing concrete substrate etc. complete including all tools and tackles as specified and directed.Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
Applying two coats of 1mm thickness waterproofing and protective coating on walls and floors ,etc. The waterproofing system should comply with ASTM C836, ASTM D6083, ASTM D4541 having Hardness Shore 'A' scale of 50.Adhersion to substrate 0.4 Mpa,tensile strength(ASTM D412) 1.4 MPa Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
Providing and applying two coats of single part elastomeric acrylic water based coating for walls based on high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides. The coating should have excellent flexibility to cover hairline cracks (upto 0.5 mm), UV resistant, microbial resistance, low dirt pickup with elongation at break of 135%, tensile strength of 1.1 N/mm2, Hardness Shore A scale of 80 Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
M&L for form work to sides and soffits of lintels, beams, columns, shelves, chajjas including overhangs etc for fair finished flat surface, complete all as specified and directed by Engr-in-charge
M&L for MS TMT bars 8mm dia and over as in reinforcement cut to length, bent to shape required including cranking bending spirally for hooping for columns, hooking ends & binding with and including MS annealed wire not less than 0.9mm dia complete all as specified and directed by the Engineer-in-Charge
The work (Item 36 to 45 of BOQ) shall be carried out through authorized and qualified applicators of the any following manufacturer only. The contractor shall submit MOU before commencement of work. Make : STP Limited or Equivalent in M/s Sika India Pvt Ltd, M/s Fosroc Chemicals, M/s Thermex
(a) A guarantee certificate for two years shall be submitted by the contractor on completion of work as specified.
(b) The unit rate quoted for item 36 to 45 of BOQ is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
(c) The defect liability period for the work shall be 05 (Five) years from the certified date of completion of work.
(d) Unit quoted rate shall be inclusive of all material, labors, tools and plants, scaffolding and working upto approx 7.5 mtr height from natural ground level.
(e) Adoption of necessary safety arrangement like safety belts. ropes. helmets, netting etc. which are required for safety of working at height exceeding 3 to 25 mtr height shall be mandatary and cost of same is deemed to be inclusive in unit quoted rates.
2 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with L-type or J type or cranked hook bolt all as spd including taking down existing sheet any type/description complete all as specified and as directed
Cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts and making good desmantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required.
Mild steel work angle, bars, flat iron for fencing , wall ties, hold fasts, clamps, handles, straps and similar small articles conforming to Fe-410-o or Fe-310-O complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass exc 0.5 sqm each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm each pane complete all as specified and directed.
Complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/ grinder, then applying wall care putty of minimum thickness 1mm on internal surfaces of walls/ceilings as required for desired smoothness and levelling of surfaces in two by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving apply Two coats of plastic emulsion all specificed and as directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further surface finishes. Please note that the further surface finishes work will start only after approval of the prepared surface from the Engineer-in-Charge .
Preparation of old plastered or unplastered surface of ceiling brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spotsand applying one coat of white wash complete all as specified and directed.
Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
Preparation of old decorated surfaces of walls by using pressure washer, remove all dirt & dust ,applying one coat of wall care putty and applying two coats of premium oil bound distemper of required shade complete all as specified and directed by Engineer - in - Charge. Note:- Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
Preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion weather proof paint complete all as specified and as directed. Note:- Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damage portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed by Engineer-in-Charge
Repair of leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damage soil waste pipes or fittings of any shape, specification and size, making good to the damage portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and specifie by the Engineer -in- charge
Note for item No 64 & 65 :- (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case lakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as direct by the manufacturere specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
Glazed ceramic coloured tiles 450 x 300 mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado, laid over and including backing coat with cement mortar 10 mm thick in CM 1:3 complete complete all as specified and directed. Note : The Unit rate is demend to be included for : (a) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Joint free non skid coloured ceramic tiles 7 mm to 8mm thick (Square/rectangular) area of each tile exceeding 0.09 Sqm but n exc 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles , laid over and including cement screed bed 15 mm thick in CM 1:4 complete Note : The Unit rate is demend to be included for : (a) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Taking down the existing locking system, contains any number of levers repalcing the strucked/damaged levers, applying oil to all parts and making functional properly and refixed in position complete all as specifed and as directed
Mortice lock brass 4 levers vertical type of size 100mm fixed as in repair
100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
Fixed in repair 300 mm long aluminium alloy ,anodisd ,sliding door bolt with hasp,stable (bolt type) and fixing of clips sheet ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed
250 mm long aluminium alloy ,anodisd ,sliding door bolt with hasp,stable (bolt type) and fixing of clips sheet ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed .
Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor 150mm Including taken down existing one complete all as specified and as directed by Engneer-in-Charge
Factory made UPVC three track sliding Window frame having 2 tracks for glass shutter and 1 track for mosquito sash made of upvc profile section of size 73mm x 42mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm). Sliding glass shutter shall be made of UPVC section of size 55mm x 33mm and sliding wire mesh shutter shall be made of UPVC section of size 40mm x 22mm. All section of the frame, sash, transom & mullion, as applicable, shall be duly reinforced with G/J/U/O shape galvanised mild steel section of required thickness considering structural / wind load requirement. System shall be provided with the suitable upvc bead for glazing of the system & fitted with inner & outer EPDM seal gaskets. Clear Glass of Saint Gobain / Modiguard make with thickness of 4mm and stainless steel wire cloth of 0.19mm nominal dia. All welded joints are to be neatly trimmed & feature grooved/raised nib finish so make the finished product free from all sharp edges & burrs. All the corner / mullion / transom joints of the frame and sash shall be mitered cut & fusion welded without any mechanical joining. System shall have adequate drainage mechanism to permit the escape of water from horizontal member beneath each sealed unit. System is to be provided with proper operating & locking hardware mechanism. Window locking system will be either both side push lock system or semi-circle locking system in centre. Complete window shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using quality fasteners & silicon glue is applied to fill up the crevice between wall and window frame for leak proof installation including taking existing one complete all as specified. Note: - The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
Factory made UPVC Ventilators design will be like top part fixed with exhaust fan provision and bottom part with fixed louver strips.Ventilators frame made of upvc profile section of size 45mm x 43mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm). Wherever required /specified, system shall havev the fix mullion of size 45mm x 60mm having outer wall thickness of 2.0mm(+/- 0.2mm). All section of the frame,transom & mullion shall be duly reinforced with G/J/U/O shape galvanised mild steel section of required thickness considering structural / wind load requirement. System shall be provided with the suitable upvc bead for glazing of the system & fitted with inner & outer EPDM seal gaskets. Pinhead Glass with thickness of 4mm required for fixed & louvers strips. All welded joints are to be neatly trimmed & feature grooved/raised nib finish so make the finished product free from all sharp edges & burrs. All the corner / mullion / transom joints of the frame shall be mitered cut & fusion welded without any mechanical joining. System shall have adequate drainage mechanism to permit the escape of water from horizontal member beneath each sealed unit. System is to be provided with proper operating & locking hardware mechanism. Complete ventilator shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using quality fasteners & silicon glue is applied to fill up the crevice between wall and ventilator frame for leak proof installation including taking existing one complete all as specified. Note :- The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws including dismantling of existing roof sheet complete all as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of existing roof sheetas specified
Note for Pre-painted coloured Galvalume roofing :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
12mm thick toughened glasss frameless partition, with option of swing and sliding doors with all necessary to patch fittings and bottom insert like corner connection and side connector and bottom insert to the floor about 15 to 30mm or done with aluminium profile 12mm depth complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
Removal of existing treatment, cleaning the existing surface with wire brush and by using pressure washer, removal all dirt and dust completely, including preparation and applying two coats of cement base paint over a coat of primer on external surfaces of wall complete all as specified and as directed. Note:- Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying two coat oil bound distemper complete all as specified and as directed.
Preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying two coats of exterior emulsion paint complete all as specified and as directed.. Note:- Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
Resecuring or easing & adjusting without taking down shutters of exc 1 Sqm but n exc 2 Sqm each
Repair to doors by supply and fixing middle rail of second class hard wood 35 mm thick including making of grooves and fixing new middle rail by replacing defecting rail using fevicol and wooden pinning. Size of lock/middle rail shall be 150 mm wide and shall be treated with two coats of painting over primer complete all as specified and directed by Engr-in-charge.
Providing and injecting chemical for post constructional Anti TermiteTreatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same all as specified and directed.
Repairing existing aluminium door/windows, area of shutter not exceeding 3 sqm each, in following steps, complete (a) Taking down shutter from the frame (b) Replacement of jointing cleats, glazing clips, rubber packing, snap beading, screws etc complete to make the shutter fully functional (c) Re-fixing the shutter in same location after carrying out repairs (d) Cleaning the glass
Applying silicon sealent on joints of wall,cill jambs roof etc including taking down existing one complete all as specified as directed
6mm thick frame less bevelled edge mirror fixed with steel stud as per direction of Engineeer-in-charge including taking down all as specified and as directed.
M&L false ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board (Lake & Hill) all as per Everest regular T-2430 or equivalent (Make-Ramco/Charminar/Armstrong). including dismantling.
Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Note for item No 96 : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Vitrified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting/dado. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Note for item No 98 : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Preparation of old painted wooden surface of any description and applying one coats of synthetic enamel paint using mechanical means, not otherwise described over 10 cm width or girth, complete all as specified and directed.
Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint using mechanical means over 10 cm width or girth, not other wise described complete all as specified and as directed.
Note for item No 100 & 101 :- (a) All synthetic enamel paint, shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
100mm long medium weight fixed as in repair and welded to metal fram n exc. 2.5 cm in length and n exc 6 mm of metal thickness.
Material and Labour for Granite work (of any type) 18 to 20mm thick (table rubbed and polished including round edge) in steps, jambs, pillars, windowcills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade over and including 15mm thick screed bed in cm 1:4 including dimantling existing one complete all as specified and directed by Engineer-in-Charge. NOTE : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Factory made UPVC casement door frame made of UPVC profile section of size 60mm x 58mm (wxh) having outer wall thickness of 2.0mm(+/-0.2mm) and 3 box multi chamber construction.The shutter of outward openable door shall be made of size 78 x 60mm (shutter of inward openable door shall be made of size 71 x 60mm) having outer wall thickness of 2mm(+/-0.mm). Doors will have 6mm thick partical board . Wherever required/specified, system shall have the fix mullion of size 72mm x 60mm having outer wall thickness of 2.00mm(+/- 0.02mm) . All sections of the frame ,saash,transom , & mulion shll be duly reinforced with G/J/U/O shpe galvanised mild steel section of required thickness considering structural / wind load requirement. All the corners/mullion / transom joints of the frame & sash shall be mitred cut & fusion welded without any mechanical joining. All welded joints are to be neatly trimmed and feature grooved/raised nib finish so as to make the finish product free from all sharp edges and burrs. System shall have adequate drainage mechanism to permit the escape of water from horizontal meber beneath each sealed unit.System shall be provided with the suitable uPVC beads for glazing of the system with specified/required single /IGU Glass, duly cut at correct degree & fitted with K & O type inner and outer EPDM weather seal gaskets . System is to be provided with proper operating and locking hardware mechanism as per system. Complete door shall be fixed in to the existing pre finished aperture, by drilling and fixing through the outer frame using high quality fastners & silicon glue is applied to fill up the crevice between wall and door frame for lek proof installation including taking existing one complete all as specified. Note : The contractor will have to submit 5 years warranty certificate for upvc profile and 1 year warranty certificate for hardwares.
12mm thick toughened glass for doors including polished by machine on edges including stainless steel clips/hinges, stainless handles (02 Nos), floor spring double action complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
250 mm mild steel ordinary rat rail rod pattern spring including roller and roller plate including taking down existing one all as specified and directed.
Repair to doors by supply and fixing bottom rail of second class hard wood 35 mm thick including making of grooves and fixing new bottom rail by replacing defecting rail using fevicol and wooden pinning. Size of bottom rail shall be 200 mm wide and shall be treated with two coats of painting over primer complete all as specified and directed by Engr-in-charge.
Repair to doors by supply and fixing Top rail of second class hard wood 35 mm thick including making of grooves and fixing new top rail by replacing defecting rail using fevicol and wooden pinning. Size of stiles/ top and freeze rails of size 100 mm wide and shall be treated with two coats of painting over primer complete all as specified and directed by Engr-in-charge.
Applying two coat of synthetic enamel paint over a coat of pink primer of any description over 10 cm width or girth including preparation of new wooden surfaces complete all as specified and directed.
Note for item No 117:- (a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Attending unserviceable/ non functional street light complaints (for street light/perimeter lights/high mast light/flood light etc of any type/size fitted on poles/walls/post/pillers etc) by deploying technically qualified and experinced techinicians to find out defective/taking out unserviceable parts such as electronic driver, pvc insulated copper conductor cable for connecting street light fittings etc and repairing by changing the defective parts including minor repair to cable connection/loose connection, screws,nuts & bolts and insulation tap to insulate the LT joint etc and testing complete all as specified and as directed for domestic area of old kalpa colony, new kalpa colony, Mehra colony, MAP qrts, Akash enclave, Gulmohar enclave, Kiran enclave, MES colony, AFWWA, various connecting roads and other facilities such as shoping complex/ various institutes/ messes/ play ground, complete perimeter etc located in complete domestic area and technical area at AF Station Sulur
Note for item No 125 : The following items are deemed to be inclusive of quoted rate :-
(a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) 'Supply only' items to be delivered/ supplied to AGE E/M store yard as per qty asked by Engineer-in-Charge with in one calender month from the date of commencement of contract and these items will be issued from AGE E/M store yard for attending unserviceable/ defective street light complaints.
(c) Contractor or his Authorised Representitive has to inspect all Street/ Security Lights on Daily basis at their own arrangement between 7.00 PM to 9.00 PM and maintain the record in Register which will be put up to Engineer-in-Charge/ JE on the very Next day.
(d) A Joint Inspection for Serviceability of all Street/Security Lights will be carried out from 7.00 PM to 9.00 PM on every MONDAY by Engineer-in-Charge/ JE (E/M)/ User alongwith Contractor or his authorised Representitive and Nos. of unserviceable Street/ Security Lights to be entered in a Register for preparing Weekly.
(e) Contractor has to arrange own moveable Generator of suitable capacity for repairing and testing of the Street/ Security Lights, defect rectification of Cables, etc. and to check the serviceability after repair. No Electricity shall be provided by the Department on this account.
(f) Quoted Unit Rate shall deemed to be inclusive of attending any breakdown of Street/ Security Lights during night. Contractor has to arrange Electrician and Helper and all necessary T&P and Equipments to remove the breakdown. Fault will be intimated through Telephone/ SMS.
(g) In case of any delay in attending the complaint more than 12 hrs after handing over routine/urgent work, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(h) The penalty shall be applicable to the contractor if the delay is noticed by the Engr-in-Cahrge more than twelve hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge shall handover the slip containing specification of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the complaint immediately and shall report to Engr-in-Charge with in 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine / urgent works from the executive. If the nature of job is such that the work cannot be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more then twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 50/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 56 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforceabove as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt. The decision of the Accepting Officer is this regards shall be final and binding.
(j) Contractor has to ensure serviceability of all Street/ Security Lights of DOMESTIC & TECHNICAL AREA on Daily basis in any Weather Condition at their own arrangement.
(k) Contractor shall provide conveyance to the deployed labour for maintaining the services without any extra cost to department.
(l) Vehicle mounted ladder for maintaining services shall be provided by the contractor at no extra cost to department.
(m) Materials required for the repairing of the lights shall be measured and paid separately under respective item(s). But labour required for taking down, dismantling, repairing and replacing parts and reinstalling and testing the street lights fittings shall deemed to be included in the rate quoted.
(n) Necessary T&P, Safety Belt, Vehicle, Aluminium Ladder, etc. will be arranged by the Contractor and Cost for the same shall deem to be included in the Quoted Unit Rate.
(o) All safety measures and provn of all safety devices, first aid box etc shall be provided by the contractor. Contractor will be solely responsible for full safety of the persons deployed for providing the services and department will have no liability for any type of accident/injury of any type. Unit rate quoted will be deemed to include the cost of the same and no extra payment shall be made on this part.
(p) All type of T & P, PVC insulation tapes, minor nuts/ bolts/ washers etc required for maintaining the services shall be provided by the contractor without any extra cost to department.
(q) Attending and repairing complaint for one light of any type shall be measured and paid as one Job.
(r) Earth work (if necessary at Site) for removing of any Cable Fault will be Measured and Paid under respective Items.
(s) The contractor shall maintain a record of all urgent work at and if the work is repeated due to poor workmanship, he will be liable to repair the same without any extra expenditure to the Govt.
(t) Contractor shall provide contact details of his responsible person(s) for any emergency.
(u) Any Materials replaced which are not specified in SCHEDULE OF CREDIT will be deposited to MES STORE YARD without any extra Cost to the Department.
Supply only PVC insulated Copper Conductor Cable 1.5 Sqmm, 3 Core Round Flexible for connection of Street Light Fitting, complete all as specified and as directed. Make : Havells/ Plaza/ Polycab
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 10 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 20 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 36 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 45 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 76 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
Supply only electronic Driver with input voltage 220 to 240Volt and output voltage suitable for LED light fitting of capacity 160 watt, complete all as specified and as directed. Make:- Philips, Bajaj, CG
M&L for disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 25/ 35 sqmm 3.5 core size of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
Cleaning vegetation around the LT pole completely root out from soil and clean the surface one mtr around the pole of street lights. Note : Removing of accumulated earth depth upto 15cm cleaning / Cutting the grass with hand operated petrol/ kerosene driven grass cutting machine and removing the grass waste to outside MD land is deemed to be included in quoted rate.
Supply and fixing in replacement of power contactors 63 Amps, 4 pole, 415V, including taking down old item. Make : Cat No 412556 of Legrand or equivalent of L&T/ Siemans
60W LED inverter Flood light with inbuilt real time clock (RTC) for auto ON/ OFF feature, emergency light output, shall have maximum 1.5 – 2 hours battery back up with Li-ion battery at inverter load in case of power failure, system lumen not less than 100 lumen, initial lumen at battery mode will reduce to 15-20%. Housing made up of pressure dicast aluminium body with Top maintainable and front cover clear toughened glass, with IP 66 and IK05 protection, open and short circuit protection, reverse polarity protection, high voltage cut off at 300V + 10V and 5 KV internal surge protection, PF > 0.95, THD < 10% and Driver Efficiency > or = 85%. CRI > or = 70. Make :- Halonix Model No - HLFLD-ML30-60-CWL-INV-RTC-DIMM or equivalent of Philips/ Bajaj.
Note for item No 158:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Prepairing the painted steel surfaces of existing LT steel tubular pole including cross arms, clamps MS flats, steel light bracket if any etc and applying one coat of aluminium paint(above ground/coping level) not exc 8 mtr long including painting of strips of height 0.3mtr each (three nos sky blue and three nos white), writing pole no with black paint with letters/figures 7.5 cm high and tightening of cross arms, clamps and street light brackets complete all as specified and directed.
Connector suitable for fixing of Cable of size Cross sectional area 25 Sqmm to 10 Sqmm armoured/PVC for preventing of Short Circuiting of Cable in Junction Boxes, complete all as specified and as directed.
Supply of IP 66 Pole Mounted street lighting Junction Box 160x240x120 mm made of Polycarbonate, supplied with 1 No. 6A 10KA SP MCB, 1 No. 63A 4P FR Polyamide color coded RYBN Terminals Block, 1 No. each of Earth & Neutral Terminal mounted on 35mm DIN channel and fitted inside Enclosure alongwith Pole Mounting bracket, pole clamp & hardware made of Stainless Steel 304. The Junction Box enclosure Cover should have 2 nos Polycarbonate Hinges with SS 304 Hinge pin, for Cover not to detach from Base on opening and should be properly tightened to base with Polycarbonate screws having sealing gaskets of extruded silicon rubber. The Polycarbonate enclosure should have properties Flame Retardant UL94V0, UV, Glow Wire test 960 Deg C, Impact IK08, Halogen free & RoHS compliant, Glow Wire Test for 960⁰ C. Type test reports from NABL lab in India along with Polycarbonate manufacturer batch test certificate should be submitted. Make of junction box shall be as per make mentioned in list of makes in PS.
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth for laying of cable and not exceeding 10 Sqm on plan for poles, struts, stays etc. and not exceeding 1.5 m in depth and getting out complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material to a distance not exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtr above the starting point.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Protection to cable with one layer of Fly ash bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable.
XLPE insulated, screened, PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 10 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 16 Sqmm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note for item No 170 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 10 sqmm to 16 sqmm Make : Reychems, Densons, M Seal
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Supply and fixing 90 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs upto max 2 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-90-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Note for item No 181 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Removing ,errecting steel swaged tubular pole 8.5/9 mtr long, bracket for fixing street light and refixing the same including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) for foundation of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed by Engr-in-chrage.
Preparing surfaces by removing exisiting faded sky blue and white straps on PCC poles and applying a coat of sky blue/white straps painting with synthentic enamel paint, each sky blue/white straps of 30 cm height up to 1.5 mtr from top of PCC coating, writing pole no with white paint on black base of PCC pole by sentensile measure including applaying one coat of synthetic enamel paint to clamps/cross arm/street light GI bracket fixed on pole complete all as specified and as directed.
Preparing the existing painted steel surface and painting with one coat of aluminium paint on cross arms, clamps, MS flat and street light brackets if any on Steel / RCC pole for Double cross Arm for three Phase 4 wire system.
Single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down existing one all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No : 408584 to 408595 or equivalent. of Schnieder (Multi -9)/ Siemens/L&T (Hegar).
XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
XLPE insulated,screened ,PVC Bedded, galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 Sqmm3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 25 sqmm to 35 sqmm Make : Reychems, Densons, M Seal
Supply and fixing in replacement of TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ Schneider/ ABB.
Supply and fixing 60 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, should have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs upto max 2 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-60-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Note for item No 191 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Supply, transporting to site, errecting and fixing in position, steel tubular swaged poles of 9mtr long type 410 SP- 31 IS-2713 marked complete with CI/ MS base plate, finial taper plug, bolts, nuts, washers and screws as specified, drilling of necessary holes including painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and black bituminous paint on steel surface embeded in conrete externally and throughout internally and painting 03 nos of band /strips with fluorescent , PO box red synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and number of poles all as specified & directed by Engineer-in-Charge. Note :- Earth work excavation, PCC foundation, coping will be measured and paid separately.
M&L for providing cement concrete 1:4:8 (40mm grade aggregate type D2) including necessory form work for pole foundation complete all as specified and directed by Engr-in-Charge .
M&L for providing cement concrete 1:3:6 (40mm grade aggregate type C2) including necessory form work for pole foundation complete all as specified and directed by Engr-in-Charge .
M&L PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in pole coping complete as directed.
Disconnecting of burnt/ damaged cables from panels/ junction boxes etc, cutting out the burnt out ends, making new end joints by supply and fixing new aluminium lugs/ insulation tapes etc and reconnecting using new nuts/ bolts/ washer etc and restoring three phase and neutral in the junction box complete all as directed for the 10/16 sqmm 4 core size of LT underground armoured cables. Note :- Earth work required for extending the incoming/ outgoing cable in junction box/ panel board etc shall be deemed to be included in the unit rate quoted.
Power contactors 40 Amps, 4 pole, 415V, including taking down old item. Make : Cat No 412553 of Legrand or equivalent of L&T/ Siemans
The GUI shall able to measure voltage, current, power factor, active power, apparent power, metering cumulative active energy, metering cumulative apparent energy. The scheduling which could be defined from the GUI running locally in smart device. GPRS communication between panel and could server and an option in panel for RF communication between panel and individual street lights for futuristic expansion. Wireless local control for field staff to on/ off panel in case of GSM failure. The panel should be capable of sending following alerts :- (a) Phase wise over current/ short circuit. (b) Phase wise over voltage. (c) Group failure of lights. (d) No output supply. (e) Tampering of door. (f) Over voltage and under voltage protection for contractors and smart device. (g) Low power factor detection. (h) Under load and over load detection. (j) GSM network down alert. (k) RTC and NVM failure. (l) In built astronomical timer. (m) MCB tripping to be monitored on web application.
The GUI should also support Google Maps overlay for live status monitoring of panel. Support for COAT (Configuration over the air) and FOTA (firmware over the air), live instaneous load update, total monthly/ weekly/ daily power consumption, on time and saving info, configuration for SMS and email for alert and reporting complete all as specified and directed including the following :- (a) MCCB TPN 63 amps capacity 16 KA 415 Volts – 01 No (Incoming) with separate SPD of 40 KV capacity. (b) Resin cast CT’s 100/ 5A- Set of 3 (c) Multifunction digital meter class 1 accuracy feeding information to GPRS controller. (d) GPRS controller module for dual communication with additional power back up upto 48 hrs. (e) Astronomical type timer switch of appropriate load. (f) Switch 6 Amps capacity with operation between automatic mode/ manual mode/ timer mode/ off mode. (g) Line contactor, AC 3 duty, 3 phase, 415 Volts, 50 Hz, 32 Amps- 02 No (h) MCN TPN 32 Amps capacity – 02 (Outgoings) (j) Terminal block suitable for 100A rating with brass contracts for INPUT/ OUTPUT termination. (k) Anti tampering micro switch – 01 No (l) Control wiring & control MCB of 6 Amps and power wiring of toggle switch, indicators/ protection circuits contactors, gateway/ relay with 1.5 sqmm multi strand copper cable (for control wiring) and of appropriate size for power wiring, incl lugs and ferrules – 01 Job as per circuit design complete all as specified and directed. (m) Indicators for automation mode, timer mode, on mode, phase indicators, by pass mode to be provided such that they are visible from outside.
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note for item No 202 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tsested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
T C KARUNANITHI
PRIYA ENTERPRISES
eurekaenterprises
pk janardhanan
LAKSHMI ELECTRICAL ENTERPRISES
Neptune Engineers and Builders
KUMAR AGENCIES
SUPER COOL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .