| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.1 LAccepted-AOC H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | 1 | Accepted-AOC Lowest Bid | |
| 2 | 2₹19.7 L+₹82,220 (4.35%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | 2 | Rejected-Finance Not Lowest Bid | |
| 3 | 3₹20.2 L+₹1.3 L (7.05%)Rejected-Finance | 3 | Rejected-Finance Not Lowest Bid | |
| 4 | 4₹20.5 L+₹1.6 L (8.33%)Rejected-Finance E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 4 | Rejected-Finance Not Lowest Bid | |
| 5 | 5₹21.3 L+₹2.4 L (12.8%)Rejected-Finance PLOT NO 46 SECTOR PH I 03 GREATER NOIDA UP 201306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201306 | 5 | Rejected-Finance Not Lowest Bid |
Tender Value
₹23.6 L
EMD Value
₹47,240
Closing Date
31 Jan 2022, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT-10
GENP-69/2021-22 REPAIR AND MAINTENANCE OF WATER SUPPLY INSTALLATION PUMPS MOTOR BOREWELLS LT PANELS MOTORIZED VALVES DOZING PUMPS CHLORINATION AND TESTING OF WATER AT RV AND HV AREA UNDER GE AF PALAM DELHI CANTT
2022_MES_499124_1
GENP-69/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹47,240
Yes
15 Feb 2022
3 Jan 2022
1 Feb 2022
3 Jan 2022
31 Jan 2022
18 Jan 2022
Amount
Taking down defective self priming recirculation pump set of any type and make pentair of capacity 3.5 HP Three phase by unscrewing the foundation bolts, disconnecting from water connection and electric motor, opening for inspection in presence of Engr-in-Charge and carry out repair at site such as replacement of ball bearing ,check nuts ,impeller,greasing ,gland,bush,casing gasket,nut bolt , washers etc and re-fixing, re-connecting in position, testing and commissioning complete all as specified and as directed by Engr-in-Charge.
Taking down defective self priming recirculation electric motor of make pentair of capacity 3.5 HP from electric mains, isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump, opening of motor including transporting to the workshop for rewinding of motor, cutting ,removing of burnt winding, cleaning and winding of motor with copper enameled wire of same gauge and turn of existing winding , varnishing, baking , reassembling , relpacement of bearings and transporting back to the site & re-connecting same to foundation including replacement of nuts, bolts washers etc. of suitable size, testing and commissioning complete all as specified and directed by Engineer-in-charge. .
Supply only for Alam (K2 SO4) for swimming pool for purifying the existing water complete all as specified and directed by Engineer-in-charge.
Supply and fixing under water light with housing water proof LED light fittings with driver, LED-NP 300S,round light 16 W/ 12 V PAR 56 144 LEDs and necessary fixing arrangement like new iron frame suitable to base of new fitting fixed to concrete wall and easily remove and fixing the fitting for future repair work including taking down existing unserviceable light fittings of any type in swimming pool complete. Make Emaux Cat Part No 88045366 or its equivalent in Halbert.
Taking down existing LED light fitting any type in swimming pool and carry out repair work such as broken parts of LED light frame,Unsv LED bulb1W/12 V, Suitable LED driver etc and refixing the light fitting in old position including necessary fixing arrangement like new iron frame ( 04 Nos) suitable to base of fitting fixed to concrete wall and easily remove and fixing the fitting for future repair work complete all as specified and directed by Engineer-in-charge . Note :- Only LED driver and LED light shall be measured and paid separately.
Supply and fixing in replacement of LED driver upto18w/12v, suitable to under water light with housing water proof LED light fittings complete all as specified and directed by Engineer-in-charge .
S&F in replacement of PVC vacuum hose pipe 30 mtr length of 50mm dia suitable for connection of existing pipe for cleaning the swimming pool complete all as specified and directed by Engineer-in-charge. Make –Emaux/Halbert
S & F in replacement of chemical testing kit for PH & chlorine of water complete all as specified and directed by Engineer-in-charge. Make –Emaux Model No HC023/ of its equivalent in pentair
M&L for cleaning of sediments on bottom surface and side walls of Swimming pool with the help of sweeper machine and cleaning with brush, acid, alum etc and wash out entire surface area complete all as specified and directed by Engineer-in-charge. Note:- Sweeper machine for cleaning shall be provided by the department free of cost.
Supply and fixing in repair PVC pipe 75 to 90 mm including elbow, socket, Nipple, tee , all as per site requirement complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair PVC pipe 110 to 160 mm including elbow, socket, Nipple, tee, reducer socket all as per site requirement complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair union suitable to PVC pipe 75 to 90 mm complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair union suitable to PVC pipe 110 to 160 mm complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair Aqua seal valve suitable to PVC pipe 75 to 90 mm complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair Aqua seal valve suitable to PVC pipe 110 to 160 mm complete all as specified and directed by Engineer-in-charge
Supply only for TCCA -90 Spa chlorine granuals 50 KG drum white powder granual or trichloroisocyanuric acid (C3O3N3CL3) for swimming pool water purification for maintain the quality of water complete all as specified and directed by Engineer -in -charge. Make : Halbert/Declibec TCCA-90.
S&F in replacement of Standard curved poly Bristle wall brush 18 Inch complete all as specified and directed by Engr-in-Charge. Make : Halbert/Emaux/Pentair.
S&F in replacement of Leaf Skimmer of suitable size for swimming pool water cleaning complete all as specified and directed by Engineer -in -charge. Make : Halbert/Emaux/Pentair.
S&F in replacement of 250mmx30mmx1 mtr white over flow grating single pin lock system complete all as specified and directed by Engineer -in -charge. Make : Halbert/Emaux/Pentair.
M&L for Copper sulphate for colouring the water complete all as specified and directed by Engineer -in -charge. Make : Halbert/Emaux/Pentair.
S&F in replacement of SP Series side mount filter valve of 6-way two inch dia complete all as specified and directed by Engineer -in -charge. Make : Halbert/Emaux/Pentair.
Supply and fixing of LED building light luminare 50 W LED Street light (Rodeo Series) Powder coated finish, Pressure die cast aluminium housing (New Shape) type complete with acrylic cover and including suitable fittings and fixtures GI bracket, nut ,bolt etc complete including taking down existing unservicable 90W bldg lights. Cat Part No SSK-ST-50W (S) Make Syska or its equivalent in Havells/philips.
Supply and fixing LED Beam/Flood lights COB Series luminare 100 W Powder coated finish, Pressure die cast aluminium housing type complete with acrylic cover and including suitable fittings and fixtures GI bracket, nut ,bolt etc including taking down existing halogen light fitting complete. Cat Part No SSK-BLS-COB-120W Make Syska or its equivalent in Havells/philips.
Supply and fixing LED Flood lights Range luminare 90 W Powder coated finish, Pressure die cast aluminium housing type complete with acrylic cover and including suitable fittings and fixtures GI bracket, nut ,bolt etc including taking down existing halogen light fittings complete. Cat Part No SSK-BLS-CF-90W Make Syska/ Havells/philips.
Excavation in trenches not exc 1.5 meters wide and not exc1.5 meters deep for pipe line in any type of soil & getting out all as specified and as directed by Engineer-in-Charge
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thickness all as specified and directed by Engineer-in-Charge.
Removing excavated soil from site to a distance not exc 50 meters away and depositing where directed not exc 1.5 meter from the starting point all as directed by Engineer-in-Charge
Taking up CI/DI water main including all fitting with spigot socket ends and lead/tyton joints including burning out lead joints and recovering lead for 80 mm bore pipe.
All as per item No 28 above but 100 mm bore.
All as per item No 28 above but 150 mm bore.
Supply, laying, jointing and testing cast iron pipe with spigot socketed ends centrifully cast, class LA, tyton joints conforming to IS-1536-1976 laid in trenches of 80 mm bore all as specified and directed by Engineer-in-Charge.
All as per item No 31 above but 100 mm bore.
All as per item No 31 above but 150 mm bore.
M&L for 150 mm ductile iron pipe with spigot and socket ends, centrifugally cast, class k-9 (IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc all as specified and directed by Engineer-in-charge.
M&L for 100 mm ductile iron pipe with spigot and socket ends, centrifugally cast, class k-9 (IS-8329-2000) with tyton joints in any length laid in trenches or fixed on pillars etc all as specified and directed by Engineer-in-charge.
Material and labour in repair run lead joint including jointing material for cast iron pipe of 80 mm bore.
Material and labour in repair run lead joint including jointing material for cast iron pipe of 100 mm bore.
Material and labour in repair run lead joint including jointing material for cast iron pipe of 150 mm bore.
Taking up or down 15mm bore GI tubing with fittings including cleaning for removal all as specified and directed by Engineer-in-Charge.
All as per item No 39 above but 20 mm bore.
All as per item No 39 above but 25 mm bore.
All as per item No 39 above but 40 mm bore.
All as per item No 39 above but 50 mm bore.
All as per item No 39 above but 80 mm bore.
Supply, laying, jointing & testing Galvanized iron tubing medium grade with all fittings fixed to walls and ceiling or laid in floor/trenches of 15 mm bore.
All as per item No 45 above but 20mm bore.
All as per item No 45 above but 25mm bore.
All as per item No 45 above but 40mm bore.
All as per item No 45 above but 50mm bore.
All as per item No 45 above but 80mm bore.
Supply & fixing in replacement of gun metal gate valve with iron wheel head screwed both ends for 15mm bore iron pipe all as specified and directed by Engineer-in-Charge.
All as per item No 51 above but 20mm bore.
All as per item No 51 above but 25mm bore.
All as per item No 51 above but 40mm bore.
All as per item No 51 above but 50mm bore.
Supply and fixing in replacement of cast iron sluice valves, class-I, ISI marked, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets for 80 mm bore complete.
All as per item No 56 above but 100 mm bore pipe.
All as per item No 56 above but 150 mm bore pipe.
Material and labour in repair for Cast Iron specials such as tees of any size and radius, collars, tapers, tail pieces, caps and plugs upto 200 mm bore.
Supply and fixing in repair GI Fittings reducers, tee, elbow, socket, nipple, plug, reducer socket, reducer elbow, unions and other connected accessories of size 15mm to 40mm all as specified and as directed by Engineer-in-charge.
Disconnecting existing defective electric motor of any make capacity of motor upto 5 HP from electric mains isolating the connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump, opening of motor for inspection in presence of Engr-in-Charge & carrying out minor repairs at site and re-assembling the motor after repair, refixing in position re-connecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed.
All as per item No.61 here-in-before but capacity of motor 30HP to 50HP.
Material and labour for rewinding of electric motor of capacity upto 5 HP, 3 Phase with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, varnishing ball bearing MS shaft etc. complete and testing at site on full load after re-installation to the satisfaction of Engr-in-Charge.
All as per item No 63 here in before but motor 30 to 50 HP 3 phase of any type and size.
Taking out defective centrifugal pump set upto 5HP single/3 phase by unscrewing the foundation bolts, disconnecting from water connection, and disconnecting from electric motor, opening for inspection in presence of Engr-in-Charge and transported to contractor's workshop repair the pump including replacement of unserviceable housing gasket -1 set, gland packing, greasing, nut bolt with washer and refixing, re-coupling in position, testing and commissioning complete including replacement of nuts, bolts, washers etc. all as specified and as directed.
All as per item No 65 here-in-before but 30 to 50 HP 3 phase of any type and size.
Supply, fixing, connecting, testing and commissioning of MCCB 315 Amps, breaking capacity 35KA, three phase, 415 volts fixed in existing panel including necessary modification for new MCCB conforming to relevant IS including all jointing and connecting material including dismantling of existing MCCB complete all as specified.
All as per item No.67 here-in-before but 200 Amps, breaking capacity 36 KA complete.
All as per serial item No. 67 here-in-before but 125 Amps, breaking capacity 16 KA.
All as per serial item No. 67 here-in-before but 63 Amps, breaking capacity 16 KA.
All as per serial item No. 67 here-in-before but 32 Amps ( Borewells) breaking capacity 16 KA..
Disconnecting and Lifting out of existing submersible pump set from borewell capacity upto 7.5 HP alongwith their column pipe and submersible cable from bore well from any depth and lowering after repair complete all as specified and directed by Engineer-in-charge
Material and labour for rewinding of submercible pump of capacity upto 7.5 HP, 3 Phase with super enameled PVC insulated copper winding wire of suitable gauge as per existing including cleaning of rotor, slots, all winding/insulation material, bearing etc. complete and testing at site on full load after re-installation to the full satisfaction of Engr-in-Charge.
M&L for servicing of submersible pump set including replacement of thrust plate shaft sleeve, spacer, impeller - 04 Nos, SS shaft - 01 No, stud 4 Nos and filling of water and making it water tight complete all as specified and as directed by Engineer-in-charge
S&F in replacement of GI column pipe 50mm bore heavy duty class 'C' with GI flanged and drilled at both ends duly threaded and welded of 3 mtr long alongwith cut for passing the submersible cable including bolts, nuts, washers and rubber insertions packing complete all as specified and directed by Engineer-in-charge.
All as per item No 75 above but 80mm bore.
S&F in replacement of PVC insulated and sheathed submersible cable, flat, three core copper conductor cable of size 4.0 Sqmm 1100 volts grade conforming to IS-694/1990.
All as per above item No 77 here-in-before but cable size 6.0 sqmm 1100 volts grade
S&F in replacement of water proof joint for submersible cable suitable for size 4/6 Sqmm 3 core complete.
Supply , installation, testing and commissioning of pressure pumpset 1 HP with automatic pressure kit with switches the pump on and off based on turning on and off of the tap etc including taking down exisinting unserviceable pump set complete.
M&L for 100 mm bore Cast Iron non return valve without by pass arrangement confirming to IS-5312 Part-I, PN 1.0 including nuts, bolts, washers and gaskets including taking out old UNSV NRV complete.
M&L for 150 mm bore Cast Iron non return valve without by pass arrangement confirming to IS-5312 Part-I, PN 1.0 including nuts, bolts, washers and gaskets including taking out old UNSV NRV complete.
Material and Labour in replacement of Cast Iron foot valve flanged type including nuts bolts washers and rubber for 150 mm bore pipe confirming to IS-4038 complete.
Taking down PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross sectional area upto 25 Sqmm including cleaning properly for re-use all as specified and directed by Engineer-In-Charge.
All as item No 84 above but cross sectional area 50 to 95 sqmm.
All as item No 84above but cross sectional area 120 to185 sqm.
Fixing only PVC insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross sectional area upto 25 sqmm with proper clamping (minimum 3 Nos clamp per RM) all as specified and directed by Engineer-In-Charge.
All as item No 87 above but cross sectional area 50 to 95 sqm
All as item No 87above but cross sectional area 120 to185 sqm
Taking up or down Electric motor and pump of 30 HP to 50 HP of any make or type after disconnecting from all the misscelenious items such as NRV, reducer, CI-Tee, Pipelines etc and electric connection as all required at site including dimantling and taking out old rusted steel/iron channel/ foundation, vibration pad after taking all safety measures including all lifting work,welding work if any, cutting and supply and fixing vibration pad in six numbers and one steel/iron channel/motor foundation of size suitable for motor and pump of 30 HP to 50 HP,fixing the motor and pump of above said capacity and fixing all connecting items including NRV, reducer, CI-Tee, Pipelines with all minor work such as cutting, welding, electric connection ,nut, bolts, gland, flange etc of any size and make all as specified and directed by Engr-in-charge,
Supply on ALTOCH GP high strength Granular disinfectant for chlorination of water in 45 Kg PVC drum.
M&L for drilling and flushing of existing borewells of size 300mm bore, depth upto 200 mtr with drilling suitable DTH machine including surging and flushing the bore at a pressure of 7 Kg/ Sqcm complete with compressed air and flushing the sand, mud etc from the bore well with compressor complete. Note :- The rate for disconnecting and lifting out of existing submerssible pumpst from borewell upto 10 HP capacity along with their column pipe and submerssible cable from borewell from above depth and lowering after flushing and drilling existing borewell shall be deemed to be included in the quoted rate of this item.
M&L for Maintenance and servicing of standby DG Set including necessary repair of alternator (conforming Battery charging through alternator), draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , check & clean air cleane, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator ,filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the unsericeable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, replacement of battery charger, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM , oil pressure, oil temp., coolant temp. voltage, frequency , load current, battery charging , fuel consumption etc for 125 KVA DG Set. Make – Kirloskar installed at RV area pump house. Note :- The rate for all repair / replacement of above mentioned items shall be deemed to be included in the quoted rate of this item. DHPP will be issued by dept for testing .
Opening the pressure filter 1200mm dia installed at swimming pool equipment room removing the old filter media, removing all the scaling deposited on the surface area of filter assembly by using wire brush and cleaning the filter with HCC, refilling new filter media of various silica grade as reqd at site, re-assembling the filter assembly and apply one coat of good quality paint on the outer surface area of filter assembly and testing for leakage of proper functioning and testing complete all as specified and directed by Engr-in-charge
Supply & fixing in replacement of valve pit cover/ Sump manhole cover made out of MS frame 40x40x6mm thick angle iron with and including 3mm thick MS top cover with locking arrangement and painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed by Engineer-in-charge.
M&L for chemical and bacteriological analysis and potability of water obtained from Delhi Jal Board & borewells from Sriram Test House/ MCD approved micro engineering and testing lab and submitting the report in duplicate complete all as specified and as directed by Engineer-in-charge.
S&F in replacement self priming recirculation motor pump set complete of capacity 3.5 HP/ 3.30KW-RPM-3000, Head-14 mtrs induction motor type of swimming pool as per existing make & model complete all as specified and directed by Engineer-in-Charge
Supply and fixing in repair auto timer clock as per existing complete all as specified and directed
Supply and fixing in repair single phase preventor VSP-2 / VSP-1 complete all as specified and directed by Engr-in-Charge. Make : Minilac/ L &T/ Lagrand
Material & Labour for painting to existing centrifugal motor & pumping set complete including base frame with super enameled paint of existing colour coat by spray painting and writing of SM/MES No with white paint, 30 to 50 HP capacity all as specified
All as per item No 101 above but upto 5 HP capacity complete all as specified and directed
Servicing of liquid chlorine dosing system, any make, any type/capacity complete including replacement of chlorine dosing pipe upto 2.5 mtr length for each plant including servicing of motor, washing of chlorine tank with descaling agent and re-commissioning testing of plant complete all as specified and directed
Supply and fixing in repair starter ON/OFF indicator lamps (R,G) complete all as specified by Engineer-in-charge
Supply and fixing in repair Automatic pressure control switch suitable for pressure pump of capacity upto 1.0 HP complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair air tank of capacity 8L suitable for pressure pump of capacity upto 1.0 HP complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of unsv display board for showing details of pump houses and borewells as provided by Engineer -in-charge made out of white PVC sheet of size 1.5mtrX1mtr including GI angle frame and GI sheet cover to the frame and fixing of 2 nos LED tube light fittings 20 watts, connecting electrical supply to the frame including round steel pole minimum 10 feet long of suitable dia for erection on ground with PCC complete all as specified and as directed by Engineer-in-charge.
M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gape between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
Sumit Enterprises
VAISHAKHA CONSTRUCTION
PRASAD ELECTRICALS
Shri Kanchan Engineers
Commercial Traders
M/S Anand Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .