ELECT.GEN.
12 conditions · 1 needing a document upload
The contractor shall submit copy of valid Electrical Contractor License as per Clause No. 45 IE Rule 1956 along with the offer. The offer will be summarily rejected in absence of valid Electrical Contractor License.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
12 conditions · 6 needing a document upload
The registration of contractors working under Railway departments with ESIC is mandatory (if applicable as per current Law / Act)
In case a tenderer is participating as Sole Proprietor in a tender, it is mandatory for him to submit an undertaking on suitable stamp paper to this effect clearly mentioning PAN number also along with tender document at the time of submission of tender.
The tenderer may submit scanned copy of partnership deed if applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor shall ensure all precautions during digging work close to Rly signaling, telecom electrical cables etc. Penalties to be imposed for damages to any cable as per Railway board letter no. 2021/Tele/5(2)/3- Part(1)/(3425647) dtd 12.06.2023
Electrification work in connection with MMR-IGP: Coach watering pipelines (in make shift arrangement) and other allied facilities at Devlali, Nashik, Kherwadi, Kasbesukene, Odha.
BSL-L-W-T-83-2026~CR
BSL-L-W-T-83-2026
Open
Works - General
6 Months
Jalgaon, Maharashtra
₹0
₹92,300
16 Sept 2026
16 Sept 2026
28 Sept 2026
101 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 46,16,265 | ||
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of Point wiring for light, fan, exhaust fan in PVC casing capping with 2x2.5 sq. mm. FRLS multistranded PVC copper wire alongwith all accessories, running earth and and finishing of the surface after rewiring etc. (NK=4, DVL=4, ODHA=4, KW=4, KBSN=4)" | — | — | — | 11,340 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of 6 Amp. 3 pin universal plug socket complete with switch and point wiring in PVC casing caping with 2x2.5 sq mm FRLS multistranded PVC copper wire alongwith all accessories, running earth etc. on Separate Switch board. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 3,355 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of 6 A 3 Pin universal plug socket complete with switch, wiring and earth connection, to be provided in Existing light/fan board. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 690 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of 6 A 3 Pin Plug socket complete with switches and point wiring with 2x2.5 sq.mm FRLS copper conductor and copper earthing wire- 4 Nos plug in each board complete. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 3,715 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of 15 A 3 pin universal plug socket with switch alongwith independent point wiring in PVC casing capping with 2x4 sq. mm. FRLS multistranded PVC copper wire alongwith all accessories, running earth etc. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 2,760 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Submain from switch board to single phase DP switch / DP one circuit meter comprising of 2x4 sq.mm. PVC insulated FRLS 1.1KV multistranded wire & one running earth of 2.5 sq.mm. copper conducting PVC insulation green colour of 1.1 KV grade on rigid PVC casing caping with all accessories. (NK=15, DVL=15, ODHA=15, KW=15, KBSN=15)" | — | — | — | 13,500 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Mains with 2x1.5 Sq.MM FR Copper PVC insulated wire laid in provided conduit/ Trunking/ inside pole/Bus-bars or any other places. (NK=15, DVL=15, ODHA=15, KW=15, KBSN=15)" | — | — | — | 4,575 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of PVC Flexible pipe 1/2 Inch (NK=10, DVL=10, ODHA=10, KW=10, KBSN=10)" | — | — | — | 900 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of teakwood /PVC Main Board with electronic KWH meter 5-30 A cap.230 V,50 hz. Single phase duly wired with FRLS multistranded PVC copper wire with MCB,cutout, neon indication & earth connection etc. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 10,075 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of 2x20 Watts LED surface/suspended water proof industrial luminaries with polycarbonate housing and diffuser (NK=3, DVL=3, ODHA=3, KW=3, KBSN=3)" | — | — | — | 22,440 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of 2Ft 1x9 watt LED tube with accessories complete. (NK=3, DVL=3, ODHA=3, KW=3, KBSN=3)" | — | — | — | 7,410 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Lighting Circuit Board, Double Door Powder coated with locking arrangement consisting 32 A DP ELCB/RCBO as I/C and 6 Nos x 6 A SPMCB and 2 Nos x 20A O/G SPMCB Complete. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 31,225 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of 7 Mtr high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation.(Along with 2 pole RCBO 6A, with 30 mA sensitivity). (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 76,370 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of LED street Light Roadway fittings in aluminium PDC housing, toughened glass cover with IP66 protection, Wattage-72 watts, input voltage-240 volts ac, 50Hz. Complete. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 55,000 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of BLDC Super efficient electrical Ceiling Fan 1400 mm sweep (56') 260-280 RPM, Services value 7.7 input voltage 140-285 V. Power consumption 26 W to 30 W. Air delivery 270 CMM or more, 3 blades with double ball bearing with regulator of electronic step type and down rod 300-600 mm as per requirement, canopies, shackle. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 19,720 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Heavy Duty single phase Exhaust Fan of 380 mm size sweep,1440 RPM duly wired with 3 core flexible copper wire and fixing arrangement, hardware etc. complete. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 19,995 | |
| — | Breakup for | details. | — | ||
| "Supplying, erecting, testing and commissioning of minimum three & above star rated centrifugal water pump (monoblock), 415 V, three phase, 50 Hz, A.C. supply of 9.375 kW/ 12.5 HP with discharge 1320/600 lpm for head of 25/52 m and 80 mm suction/65 mm delivery pipe on provided CC foundation (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 6,81,360 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Sluice Valve 75-80 mm dia. As per specification. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 74,030 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Non return Valve 75-80 mm dia. As per specification. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 81,850 | |
| — | Breakup for | details. | — | ||
| "Supplying and installing cast iron foot valve ball type/flat type of size 80 mm dia with strainer for negative suction as per specification (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 34,990 | |
| — | Breakup for | details. | — | ||
| "Supplying and erecting ISI mark GI pipe 75/80 mm dia 'C"" class position with accessories complete. Specification (NK=50, DVL=50, ODHA=50, KW=50, KBSN=50)" | — | — | — | 3,23,750 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing and commissioning of GI C- class Bend 100-65 mm dia. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 12,550 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of M.S. Suporting clamps for 100 mm dia GI pipe (NK=4, DVL=4, ODHA=4, KW=4, KBSN=4)" | — | — | — | 9,280 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Borewell Submersible pump set alongwith wet type squirrel cage induction motor Head 83-180 mtrs, discharge 320-120 LPM Max, 10 HP, 2'' Outlet, ISI mark, 5 star rated with all accessories (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 7,04,730 | |
| — | Breakup for | details. | — | ||
| "Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.C.Submersible/ centrifugal pump set upto 20 HP consisting of Star Delta starter having relay range 13-21 Amp, S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof encloser with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase inbalance etc. (NK=4, DVL=4, ODHA=4, KW=4, KBSN=4)" | — | — | — | 2,89,800 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Heavy duty Sluice Valve 50 mm dia. as per IS specification. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 47,810 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Heavy duty Non Return Valve 50 mm dia. as per IS specification. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 45,340 | |
| — | Breakup for | details. | — | ||
| "Supply and erecting ISI mark "" C "" Class (Heavy Duty) GI pipe of 50 mm dia. with coupling/accesories. (NK=50, DVL=50, ODHA=50, KW=50, KBSN=50)" | — | — | — | 2,41,000 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of GI C- class Bend 50mm dia. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 6,690 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of M.S. supporting clamps for 50 mm dia GI pipe (NK=4, DVL=4, ODHA=4, KW=4, KBSN=4)" | — | — | — | 5,260 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Flat Flexible Copper cable, 3 core X 4 sq.mm for submersible pump & starter connection. (NK=358, DVL=358, ODHA=358, KW=358, KBSN=358)" | — | — | — | 3,20,410 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of Pump guard Current operated type Should have protection against dry run, single phase, over load, over voltage, under voltage, reverse phase protection etc. (OR ) pump up to 20 HP three phase suitable to operate in 415 volts 50 HZ AC supply. (NK=3, DVL=3, ODHA=3, KW=3, KBSN=3)" | — | — | — | 41,790 | |
| — | Breakup for | details. | — | ||
| "Supply, fabrication, fixing and erection of MS Work of miscellaneous size and for cable tray etc. including painting complete. (NK=50, DVL=50, ODHA=50, KW=50, KBSN=50)" | — | — | — | 25,000 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of maintenance free earthing as per RDSO specification no. RDSO/PE/SPEC/ PS/0109-008(REV '0') with improved earthing enhancing compound and exothermic welding (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 1,50,130 | |
| — | Breakup for | details. | — | ||
| "Supply, fabrication, laying welding and connection of GI Flat/Strip of size 25x3 mm from earth pit with GI nut Bolt suitable size. (NK=11, DVL=11, ODHA=11, KW=11, KBSN=11)" | — | — | — | 8,195 | |
| — | Breakup for | details. | — | ||
| "Supply, erection, testing & commissioning of GI Wire 8/10 SWG (NK=11, DVL=11, ODHA=11, KW=11, KBSN=11)" | — | — | — | 6,270 | |
| — | Breakup for | details. | — | ||
| "Supply & erection of FRP junction box of suitable size having terminals and 1x16 A Cut out with Two Nos of entry glands. (NK=5, DVL=5, ODHA=5, KW=5, KBSN=5)" | — | — | — | 21,350 | |
| — | Breakup for | details. | — | ||
| "Supply of 4 core 25 sqmm armoured XLPE Cable. (NK=200, DVL=200, ODHA=200, KW=200, KBSN=200)" | — | — | — | 2,44,000 | |
| — | Breakup for | details. | — | ||
| "Trenching & refilling of LT/HT/ Various sizes of PVC / XLPE cables- Along the Road (Size - 900mm x 300mm) (NK=30, DVL=30, ODHA=30, KW=30, KBSN=30)" | — | — | — | 34,650 | |
| — | Breakup for | details. | — | ||
| "Digging of cable trench 300/450 mm x 1000 mm in RCC/PCC/hard soil & refilling as per specification and requirement at the site. (NK=20, DVL=20, ODHA=20, KW=20, KBSN=20)" | — | — | — | 40,100 | |
| — | Breakup for | details. | — | ||
| "Transportation, Laying, Installation, terminating, testing and commissioning of LT/HT cable of sizes 10 sqmm to 400 sqmm in existing trench, pipe or on structure. (NK=50, DVL=50, ODHA=50, KW=50, KBSN=50)" | — | — | — | 7,750 | |
| — | Breakup for | details. | — | ||
| "Erection,testing and commissioning of cables other than trench i.e.Wall/Truss including clamp, GI wire and hardware (NK=150, DVL=150, ODHA=150, KW=150, KBSN=150)" | — | — | — | 54,000 | |
| — | Breakup for | details. | — | ||
| "Supply & laying of GI pipe Class B, ISI marked under road /Clamping with erecting pole or wall as per technical specification & drawing for passing cable. (NK=5, DVL=5, ODHA=5, KW=5, KBSN=5)" | — | — | — | 5,050 | |
| — | Breakup for | details. | — | ||
| "Supply,installation, testing & commissioning of HDPE Pipe 110 mm Nominal Dia as per IS-4984-1995. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 5,000 | |
| — | Breakup for | details. | — | ||
| "Supply and laying of RCC half round pipe 150 mm ID & 1 mtr length. (NK=30, DVL=30, ODHA=30, KW=30, KBSN=30)" | — | — | — | 16,200 | |
| — | Breakup for | details. | — | ||
| "Supply and laying of RCC Hume Pipe of size 6""(150mm) dia 2 mtr. Length. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 3,775 | |
| — | Breakup for | details. | — | ||
| "Supply, erection of RCC Type cable route marker with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 4,990 | |
| — | Breakup for | details. | — | ||
| "Supply & Erection of RCC Warning Cover and refilling the cable trench in an approved manner. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 4,730 | |
| — | Breakup for | details. | — | ||
| "Supply of all material,excavation and casting of cement concrete foundation/concreting in ratio 1:3:6 for above work. (NK=2, DVL=2, ODHA=2, KW=2, KBSN=2)" | — | — | — | 61,280 | |
| — | Breakup for | details. | — | ||
| "SETC of LT Panel Outdoor type with closing door power coated consisting 1x125 A 4 Pole MCCB incomer, 4x63 A 4 Pole MCCB, 2x32 A 4 Pole MCB, 2x32 DP MCB outgoing with copper busbar,multi-function meter and complete associated accessories. All MCCB are Microprocessor based. (NK=1, DVL=1, ODHA=1, KW=1, KBSN=1)" | — | — | — | 7,20,085 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022dt.27.04.2022.pdf GCC 2022
ATTACHMENT
ACS1to6ofGCC.pdf
ATTACHMENT
ACS7to10ofGCC_1.pdf
ATTACHMENT
ACS11toGCC2022_1.pdf
ATTACHMENT
Tenderdocument832026.pdf
ATTACHMENT
GCCApril2022dt.27.04.2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .