The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of tender document attached pertaining to his/their technical and financial eligibility. (As applicable
All requisite documents mentioned in clause 3.7 of tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
After opening of tender, any document/credential pertaining to technical, financial eligibility and available Bid Capacity constitution of firm etc. shall neither be asked nor be entertained/ considered under any circumstances and no claim or representation whatsoever from the tenderer in this regard shall be entertained. Scanned copy of the documents, uploaded by the tenderer shall be clear & readable. However Railway reserves the right to ask for any clarification on the documents/credentials already submitted by the tenderer along with the offer. ii)Tenderer may have to produce the original Documents in physical form at short notice whenever asked by Railway at any stage of tender evaluation process or even after finalization of tender. iii)In E-tender, all submissions of documents are to be uploaded on web-site. There may be last minute hic-cups and delay in uploading the Documents and payment of Earnest Money etc. Tenderer's/Prospective bidders are advised to upload their offer well in time. Railway will not be responsible for any delay/non submission of offer due to any reason whatsoever
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF DY.CPM/ELECT/GSU/DLI , DRM OFFICE, STATE ENTRY ROAD, NEW DELHI
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
Payment clause as per special conditions 100% payment will be done after successful supply, installation, testing andcommissioning of actual work done by the tenderer and on certification by the Railway representative. No part payment shall be made for supply of material.
Balance Electrical Work of Lighting and Power Supply arrangement for MSZ, JIND, ROK, BGZ, SNP and other Railway station of DLI Division under Amrit Bharat Scheme
30-R-DyCEE-GSU-DLI-26-27~NR
30-R-DyCEE-GSU-DLI-26-27
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹5.8 L
3 Sept 2026
3 Sept 2026
14 Sept 2026
175 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,89,81,825.85 | ||
| — | 5000.00 | — | — | ||
| Supply and recessing/fixing of PVC conduit pipe of 25mm size conforming to IS:9537 Part-III:1987 (or Latest version) with accessories junction box, bends etc. including making chase, plastering/clamping etc. as per site requirement conforming to IS 9537 (Part 3): 1983 or latest & as per Explanatory Note. | — | — | — | 1,65,000 | |
| — | 10000.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main as required including connections, testing and commissioning. Size = 1x1.5 sq.mm. & as per Explanatory Note . | — | — | — | 2,60,000 | |
| — | 9000.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning. Size = 1x2.5 sq.mm . & as per Explanatory Note . | — | — | — | 3,87,000 | |
| — | 3500.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning. Size = 1x4.0 sq.mm. & as per Explanatory Note . | — | — | — | 1,99,500 | |
| — | 500.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning. Size = 1x6.0 sq.mm. & as per Explanatory Note . | — | — | — | 47,500 | |
| — | 1500.00 | — | — | ||
| Supply, Fixing, testing & commissioning of following sizes FRLSH PVC insulated multi stranded copper (annealed) conductor single core cable conforming to IS 694 (or Latest Version) , and drawing in Laid (recessed /surface) PVC conduit pipe for wiring of point wiring / circuit wiring / sub main / main including connections, testing and commissioning. Size = 1x10.0 sq.mm. & as per Explanatory Note . | — | — | — | 2,19,000 | |
| — | 200.00 | — | — | ||
| Supply of Fan Rod of 900mm (1mm thick) or as per site requirement at Platform and new station building with High roof | — | — | — | 28,000 | |
| — | 400.00 | — | — | ||
| Supply, Fixing, testing & commissioning of ceiling rose, 3 plate conforming to IS : 371- 1999 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and as per Tech. Specification & as per Explanatory Note. | — | — | — | 30,000 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per Explanatory Note. Size = 3 Module | — | — | — | 3,450 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per Explanatory Note. Size= 4 Module | — | — | — | 9,800 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per Explanatory Note. Size= 6 Module | — | — | — | 10,700 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per Explanatory Note. Size= 8 Module | — | — | — | 13,300 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 conforming to latest relevant IS & as per Explanatory Note. Size= 12 Module | — | — | — | 20,500 | |
| — | 1600.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required as per IS, IE rules andsite requirement complete and conforming to CPWD General Specifications for Electrical Works Part-IInternal - 2023 conforming to latest relevant IS & as per Explanatory Note. 5/6 Amp Switch | — | — | — | 89,600 | |
| — | 80.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required as per IS, IE rules andsite requirement complete and conforming to CPWD General Specifications for Electrical Works Part-IInternal - 2023 conforming to latest relevant IS & as per Explanatory Note. 16 Amp Switch | — | — | — | 7,280 | |
| — | 200.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required as per IS, IE rules andsite requirement complete and conforming to CPWD General Specifications for Electrical Works Part-IInternal - 2023 conforming to latest relevant IS & as per Explanatory Note. 3 pin 5/6 A socket outlet | — | — | — | 21,000 | |
| — | 80.00 | — | — | ||
| Supplying and fixing following modular switch /socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required as per IS, IE rules andsite requirement complete and conforming to CPWD General Specifications for Electrical Works Part-IInternal - 2023 conforming to latest relevant IS & as per Explanatory Note. 6 pin 15/16 A socketoutlet | — | — | — | 11,600 | |
| — | 4.00 | — | — | ||
| Supply & testing of ISI markedwater cooled vertical typemonoblock submersible pumpspof capacity 5 HP, 2-3 stage, 380- 450LPM, 36-42 meter head, SSimpellar and copper rotor and suitable size ISI marked cable. | — | — | — | 1,59,307.96 | |
| — | 2.00 | — | — | ||
| Supply of 16 Meter height HighMast lighting system completewith raising loweringarrangement and suitableLantern Carriage for 09 Nos.LED light luminaries and controlgear including accessories likelightning conductor, Aviationneon light, integral drum winchcompensating disc head frame,power tool, manual tool, doubleframe with foundation bolts etc.Including casting of RCCfoundation as recommended byManufacturer and as perexplanatory note includingerection, testing andcommissioning. | — | — | — | 4,96,552.4 | |
| — | 2.00 | — | — | ||
| Design, manufacture, supply,installation, testing &commissioning of Outdoor typeTimer Control Panel suitable tooperate 3 phase 4 wire 415 VACsupply system for automaticswitching OFF & ON of allluminaries as per technicalspecification with followingaccessories : -- MCB (TPN) 63A. B/C 10 KA -1 No. -Timer withCM 40 Contactor chargeablecells/battery-1No. - ToggleSwitch - 1 No. | — | — | — | 19,527.36 | |
| — | 50.00 | — | — | ||
| Supplying and fixing one/two module stepped type electronic fan regulator on the existing modular plate switch boxincluding connections butexcluding modular plate etc. asrequired. | — | — | — | 17,317 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 2x18 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note | — | — | — | 2,33,000 | |
| — | 30.00 | — | — | ||
| Supply, installation, testing and commissioning of Heavy Duty, Powder coated Iron Stand for mounting of split AC unit. (Wall/Floor mounting as per site requirement) at all Amrit station with loading, unloading safety with testing of air-conditioner | — | — | — | 20,370 | |
| — | 400.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED down lighter, housing aluminum diecast, white powder coated and PMMA diffuser having system wattage less than or equal to 15-18Watt complete with all mounting arrangement, accessories complete confirming to CEE/NR's spec.No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No.PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 3,43,600 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED deep recessed down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15 Watt complete with all mounting arrangement, accessories complete confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note | — | — | — | 1,22,100 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaries 595x595 mm size, recessed mounting fitting (Tile type), as per IS : 10322 having system wattage less than or equal to 48 Watt, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement with suitable frame to avoid droping down of fitting of make Phillips, Bajaj, Havells or similar confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 3,53,700 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing and commissioning of 4-feet long surface mounting 36-Watt,5700K,CRI>80, LED Luminaire as per CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') orlatest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at TechSpec-II attached or latest, IS, IE rules and site requirement. Fitting shall be environmentally friendly,long life, corrosion resistant, impact proof IP 66 with PC housing & opal finish cover suitable for wetlocation similar to Make - Havells Model No. MAGNUM NEO or equivalent. Fitting shall be suitable foroperation on single phase 240Volt, 50 Hz AC supply & as per Explanatory Note. | — | — | — | 6,63,800 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing & commissioning of 25A, 2P 30mA RCBO AC type confirming toIS 12640-2 & IEC 61009-1: latest complete & as per Explanatory Note. | — | — | — | 1,10,138.5 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing & commissioning of 63A, 4P 30mA RCBO AC type confirming toIS 12640-2 & IEC 61009-1: latest complete & as per Explanatory Note. | — | — | — | 1,82,207.5 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED based highbay luminary with IP 66 having system wattage less than or equal to 150 Watt complete confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev-'3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note | — | — | — | 2,98,350 | |
| — | 18.00 | — | — | ||
| Supply, fixing, testing and commissioning of 150 watt LED based flood light luminary with cool white light, pressure die cast aluminum housing, IP 66 or better having system wattage complete confirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per Explanatory Note. | — | — | — | 1,35,846 | |
| — | 30.00 | — | — | ||
| Supply, Fixing, testing & commissioning of LT distribution board double door typemade up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 43 phosphatised powderpainted complete with neutral link, earth point, Din rail and prewired confirming to IS:13032, IEC60947 & IS/IEC:61439 or latest of make ABB, Siemens, L&T, Schneider, Legrand or equivalent withfollowing items of matching make to be fixed in distribution board, confirming to IS/IEC:60898-1:2002 or latest, IE rules and site requirement. It should be rodent entry proof. It should also includewell dressing and coding of circuit & as per Explanatory Note 63A DP RCBO 30 mA= 01 No.(Incoming) 6-32A MCB SP "C" Series = 09 Nos. (Outgoing) It should be rodent entry proof. It shouldalso include well dressing and coding of circuit IP2X terminal , reversible door with 180 degreeopening, cement spill protection, detachable gland at top and bottom and short link for MCBs. Itshould also include proper tagging on electrical wires/cables which clearly indicate the incomingpoint or source and outgoing point of wires/cables. | — | — | — | 1,64,475.9 | |
| — | 80.00 | — | — | ||
| Supply, fixing, testing and commissioning of 45 watt LED based street light luminarywith cool white light, pressure die cast aluminum housing, IP 66 or better having system completeconfirming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-Iattached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached orlatest & as per Explanatory Note. | — | — | — | 2,53,920 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing and commissioning of 90W LED based street light luminarywith cool white light, pressure die cast aluminum housing, IP 66 or latest complete confirming toCEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached &PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as perExplanatory Note. | — | — | — | 2,65,120 | |
| — | 10.00 | — | — | ||
| Supply, Laying, fixing and commissioning of LT straight through joints along with loop of cable of following sizes as per IS/IE rules and site requirement and satisfaction to the Railway representative. Size = 50-95 sq.mm conforming to IS:7093 or latest & as per Explanatory Note | — | — | — | 41,260 | |
| — | 10.00 | — | — | ||
| Supply, Laying, fixing and commissioning of LT straight through joints along with loop of cable of following sizes as per IS/IE rules and site requirement and satisfaction to the Railway representative. Size = 120-185sq. mm conforming to IS:7093 or latest & as per Explanatory Note | — | — | — | 46,490 | |
| — | 10.00 | — | — | ||
| Supply, Laying, fixing and commissioning of LT straight through joints along with loop of cable of following sizes as per IS/IE rules and site requirement and satisfaction to the Railway representative. Size = 240-400Sq. mm conforming to IS:7093 or latest & as per Explanatory Note. | — | — | — | 48,990 | |
| — | 500.00 | — | — | ||
| Supply, installation, testing and commissioning of Drainage pipe (25/32 mm size) per meter at all Amrit station with loading, unloading safety with testing of air-conditioner | — | — | — | 54,025 | |
| — | 3500.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size direct in ground including excavation((upto 75-100 cm depth and not lessthan 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required asper detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016)or latest & as per Explanatory Note. Upto 35 sq. mm | — | — | — | 13,33,500 | |
| — | 1000.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size direct in ground including excavation((upto 75-100 cm depth and not lessthan 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required asper detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016)or latest & as per Explanatory Note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 4,45,000 | |
| — | 1000.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size direct in ground including excavation((upto 75-100 cm depth and not lessthan 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required asper detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016)or latest & as per Explanatory Note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 4,70,000 | |
| — | 1000.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation((upto 75-100 cm depth and not less than 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per Explanatory Note. Above 185 sq. mm and upto 400 sq. mm | — | — | — | 5,21,000 | |
| — | 1500.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formationincluding excavation(upto 75-100 cm depth and not less than 55 cm wide & maintaining gap not lessthan 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc asrequired as per detail drawing approved by competent authority and conforming to IS 1255(Reviewed in 2016) or latest and explanatory note. Upto 35 sq. mm | — | — | — | 4,44,000 | |
| — | 1500.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formationincluding excavation(upto 75-100 cm depth and not less than 55 cm wide & maintaining gap not lessthan 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc asrequired as per detail drawing approved by competent authority and conforming to IS 1255(Reviewed in 2016) or latest and explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 4,71,000 | |
| — | 1000.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formationincluding excavation(upto 75-100 cm depth and not less than 55 cm wide & maintaining gap not lessthan 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc asrequired as per detail drawing approved by competent authority and conforming to IS 1255(Reviewed in 2016) or latest and explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 3,34,000 | |
| — | 500.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation(upto 75-100 cm depth and not less than 55 cm wide & maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest and explanatory note. Above 185 sq. mm and upto 400 sq. mm | — | — | — | 1,96,000 | |
| — | 8500.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on wall surface/underground already laid pipe as required. In case of any demolition of PCC, RCC,road, wall surface etc. the contractor should ensure repairing of the same on own expenses as persite requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in2016) or latest & as per Explanatory Note. Upto 35 sq. mm (clamped with 1mm thick saddle) | — | — | — | 5,10,000 | |
| — | 4000.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on wall surface/underground already laid pipe as required. In case of any demolition of PCC, RCC,road, wall surface etc. the contractor should ensure repairing of the same on own expenses as persite requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in2016) or latest & as per Explanatory Note. Above 35 sq. mm and upto 95 sq.mm (clamped with25x3mm MS flat clamp) | — | — | — | 5,72,000 | |
| — | 1500.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on wall surface/underground already laid pipe as required. In case of any demolition of PCC, RCC,road, wall surface etc. the contractor should ensure repairing of the same on own expenses as persite requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in2016) or latest & as per Explanatory Note. Above 95 sq. mm and upto 185 sq. mm (clamped with25/40x3mm MS flat clamp | — | — | — | 2,52,000 | |
| — | 1500.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size on wall surface/underground already laid pipe as required. In case of any demolition of PCC, RCC,road, wall surface etc. the contractor should ensure repairing of the same on own expenses as persite requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in2016) or latest & as per Explanatory Note. Above 185 sq.mm and upto 400 sq. mm (clamped with25/40x3mm MS flat clamp) | — | — | — | 3,73,500 | |
| — | 1200.00 | — | — | ||
| Supplying and installing following size of perforated Hot Dipped Galvanised Iron cabletray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspendersincluding G.I. bolts & nuts, etc. as required conforming to conforming to IS/IEC 61537:2006 & as perExplanatory Note. 150 mm width X 50 mm depth X 1.6 mm thickness | — | — | — | 9,34,800 | |
| — | 500.00 | — | — | ||
| Supplying and installing following size of perforated Hot Dipped Galvanised Iron cabletray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspendersincluding G.I. bolts & nuts, etc. as required conforming to conforming to IS/IEC 61537:2006 & as perExplanatory Note. 300 mm width X 50 mm depth X 1.6 mm thickness | — | — | — | 4,62,000 | |
| — | 150.00 | — | — | ||
| Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as perIS:3043 (latest version)to achieve earth resistance less than 5 ohms including construction ofmasonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400mmx 400 mm) on top, provision of earth plate, connections from earth electrode to switch gear/poleas per drawing & as per Explanatory Note. | — | — | — | 8,91,600 | |
| — | 1000.00 | — | — | ||
| Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per IS:3043 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) & as per Explanatory Note. | — | — | — | 1,54,000 | |
| — | 2000.00 | — | — | ||
| Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required as per IS:3043 (Latest version) and as per Explanatory Note | — | — | — | 1,10,000 | |
| — | 10.00 | — | — | ||
| Earthing with 600x600x3mm thick copper plate earth electrode as per IS 3043(Latest version), to achieve earth resistance less than one ohm, including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (Approx. size 600x600 mm) on top, watering pipe, connections from earth plate to top with 40x6mm copper stip in 50 mm dia pipe class 'B' provision of earth plate as per drawing and as per Explanatory Note. | — | — | — | 1,17,310 | |
| — | 100.00 | — | — | ||
| Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode confirming to relevant IS as per IS:3043 (Latest version), including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) conforming to CPWD DSR(E&M) 2025 & as per Explanatory Note. | — | — | — | 1,04,800 | |
| — | 200.00 | — | — | ||
| "Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less DirectCurrent (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long downrod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not lessthan 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD(Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed controland all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACsupply Ceiling Fan compliant to IS 374:2019 or latest fan i/c external connections with 1.5 sq.mmFRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1400mm, service value >= 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) conforming toCPWD DSR(E&M) 2025 item no. 9.2.4 & as per Explanatory Note. | — | — | — | 5,91,800 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing and commissioning of 1200 mm sweep AC ceiling fan, 230 VoltSingle phase 50 Hz, complete with capacitor, double ball bearing , shackle, canopy ,withoutregulator as per site condition and technical scope of work. (Make:- Havells, Bajaj, CGL, Usha). " Itshall also include the scope of supply and installation of safety cord of SS as per IS:302 Part 2 Sec-80. Dia & length of such cord shall be as per recommendation of OEM of fan and same shall beapproved by railway & as per Explanatory Note | — | — | — | 5,71,000 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing and commissioning of 400 mm sweep BLDC wall mounted fancomplete conforming to relevant IS/IEC standards & as per Explanatory Note. | — | — | — | 40,080 | |
| — | 15.00 | — | — | ||
| Supply, fixing, testing and commissioning of 250mm sweep fresh air fan completeconforming to IS 2312 & IS 302 or latest and other relevant IS/IEC standards and as per explanatorynote | — | — | — | 19,890 | |
| — | 40.00 | — | — | ||
| Supply, installation, testing and commissioning of single phase propeller typeexhaust fans sweep size 300 mm etc. including grounting of MS nuts, bolts and connection completeas per conforming to IS 2312 & IS 302 and other relevant IS/IEC standards & site requirement and asper explanatory note. Make Bajaj, Usha, Havells, Orient or equivalent | — | — | — | 1,08,960 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing and commissioning of 380mm sweep, 1400 rpm (approx)propeller type exhaust fan complete in all respect as specification and as per site requirement,including grouting of nut, bolts, washer and with the suitable fasteners conforming to IS 2312 & IS302 or latest and other relevant IS/IEC standards . Make Bajaj, Usha, Havells, Orient or equivalentand as per explanatory note | — | — | — | 1,34,840 | |
| — | 20.00 | — | — | ||
| Supply fixing testing and commissioning of Heavy duty wall mounted air circulator fan 600 mm (24 inch), 1440 RPM ,180 watt, Air delivery 270 cubic meter per minute, No of blade 3, single speed, suitable to work on 230 Volts 50 HZ, single phase IS 2312 & IS 302 or latest and other relevant IS/IEC standards & as per explanatory note. | — | — | — | 1,36,780 | |
| — | 40.00 | — | — | ||
| Cutting/removing of existing rail pole/ tubular pole/octagonal pole including overhead conductor, bracket, insulators, earth wire, guard wire etc. as per site requirement andinstruction of site In charge and after removal of material, it shall be handed over to site inchargeand stacked at suitable location. All materials are to be transported from site to Railway Store asdecided by Railway administration. Note: Measurement shall be done in items of number of polesdismantled & as per Explanatory Note | — | — | — | 47,840 | |
| — | 10.00 | — | — | ||
| Supply & erection of hot dip galvanized octagonal pole 5 Mtrs. long Single Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size 200 x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long (or as per site requirement) suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm double insulated weather proof cables confirming to IS 456 & other relevant IS/IEC standards & as per Explanatory Note. | — | — | — | 86,980 | |
| — | 50.00 | — | — | ||
| Supply & erection of hot dip galvanized octagonal pole 5 Mtrs. long Double Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size 200 x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long (or as per site requirement) suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm double insulated weather proof cables conforming to IS 456 & other relevant IS/IEC standards & as per Explanatory Note | — | — | — | 5,15,600 | |
| — | 20.00 | — | — | ||
| Supply & erection of hot dip galvanized octagonal pole 7 Mtrs. long Single Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size 200x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long (or as per site requirement) suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm double insulated weather proof cables conforming to IS 456 & other relevant IS/IEC standards & as per Explanatory Note | — | — | — | 3,23,980 | |
| — | 400.00 | — | — | ||
| Supply installation, testing and commissioning of Refrigerant Cu pipe 5/8 - 3/8 inch or 3/8 1/2 - 5/9inch dia as per site requirement i.e. on the basis of capacity of AC unit with all accessories insulation of both pipes with proper taping as per site requirement at all Amrit station with loading, unloading safety with testing of air-conditioner | — | — | — | 3,72,324 | |
| — | 50.00 | — | — | ||
| Supply, installation, testing and commissioning of all in one solar street lightingsystem with 05 mtrs high octagonal GI pole as per IS 2629/BSEN ISO 1461, 30 - watt solar streetlight should be tested as per IS 10322 part- 5 Sec- 3 or IEC 60598-2-3, 120- watt solar panel, lithiumionstorage battery 12.8 V /30 Ah complete with ingress protection IP67 complete & as perExplanatory Note. | — | — | — | 15,10,200 | |
| — | 8.00 | — | — | ||
| Design, Manufacture, supply, erection, testing & commissioning of the outdoor type LT Feeder Pillar , suitablefor 3 Phase, 4 wire 415 Volts, AC supply system comprisingwith : Incoming MCCB 4P 250Amp with adjustable thermalmagnetic release & 35KA B/C=01 No. Outgoing MCCB 4 Pole125 A 35 KA B/C - 02 Nos.Outgoing MCCB 4 Pole 63 A 35KA B/C - 06 Nos. OutgoingMCCB 4 Pole 32 A 35 KA B/C - 04 Nos. The feeder pillar shallbe complete with 250A CopperBus Bars for Phases and 125Afor Neutral as per drawingapproved by Railways andexplanatory note. Note: Designand mounting arrangement offeeder pillar shall be gotapproved from competentauthority. | — | — | — | 12,64,207.52 | |
| — | 50.00 | — | — | ||
| Supply, erection testing and commissioning of out door type distribution box havingIP 65 complete with 4 nos Aluminium bus bars 250A capacity fabricated with 14 SWG MS sheet steel,dust and vermin proof with anti corrosion treatment IS:13032, IEC 60947, IS/IEC: 61439 or latest &as per Explanatory Note. | — | — | — | 2,42,146.5 | |
| — | 10.00 | — | — | ||
| Dismantling of existing highmast tower complete with allaccessories and depositing thereleased material in the Railwaystore as decided by Railwayadministration includingtransportation of all the materialfrom site and as perexplanatory note | — | — | — | 2,22,343.1 | |
| — | 1.00 | — | — | ||
| Design, Manufacture, Supply,Installation, Testing &Commissioning of outdoor type500kVA, 11 kV/ 415 V Packagetype Sub- station complete withthree way RMU and as perexplanatory note | — | — | — | 29,60,262.12 | |
| — | 400.00 | — | — | ||
| Design, manufacture, supply,fixing, testing & commissioningof Single Sided LED typeSignage Board as per RBguidelines letter no. 2023/SD-II/22/07/02 dated 15.05.2023including connections with 2.5sq.mm PVC insulated multistranded FRLSH ISI markedcopper conductor cable and asper site requirement. NOTE:The signage board of differentsizes may be required. Priorapproval of message, color andsize shall be taken fromcompetent authority. | — | — | — | 6,65,484 | |
| — | 1000.00 | — | — | ||
| Design, manufacture, supply,fixing, testing & commissioningof Double Sided LED typeSignage Board as per RBguidelines letter no. 2023/SD-II/22/07/02 dated 15.05.2023including connections with 2.5sq.mm PVC insulated multistranded FRLSH ISI markedcopper conductor cable and asper site requirement. NOTE:The signage board of differentsizes may be required. Priorapproval of message, color andsize shall be taken fromcompetent authority. | — | — | — | 22,07,000 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT distribution board surface mountingdouble door out door type made up of CRCA sheet sheet with anti corrosion treatment and suitable,IP 43 phosphatised powder painted complete with neutral link, earth point, Din rail and prewiredconfirming to IS:13032 & IEC 60947 & IS/IEC:61439 or latest of make ABB, Havells, Siemens, L&T,Schneider, Legrand, C&S or equivalent with following items of matching make to be fixed indistribution board, confirming to & IS/IEC:60898-1 :2002 or latest, IE rules and site requirement. Itshould be rodent entry proof. It should also include well dressing and coding of circuit & as perExplanatory Note 63A 4P RCBO 100 mA= 01 No. (Incoming) 6-32A MCB SP ""C"" Series =18 Nos.(Outgoing)" It should be rodent entry proof. It should also include well dressing and coding of circuitIP2X terminal , reversible door with 180 degree opening, cement spill protection, detachable glandat top and bottom and short link for MCBs. | — | — | — | 4,68,560 | |
| — | 4.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of front operated double door typeweather proof feeder pillar body made of CRCA sheet sheet with anti corrosion treatment andsuitable having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the followingMCCB's fixed in it of make: Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming toIEC 60947 & IS/IEC:61439 or latest with digital measuring instrument & bus-bar arrangement and asper latest IS, IE rules and site requirement. It should be dust and vermin proof and powder coatingas per IS 13871-2021 (or latest version & as per Explanatory Note. 4P MCCB 250Amps 36 kA withadjustable thermal & fixed magnetic release = 01 No. (Incoming) 4P MCCB 125Amps 36 kA withadjustable thermal & fixed magnetic release = 02 No. (outgoing) 4P MCCB 63Amps 36 kA withadjustable thermal & fixed magnetic release = 04 No. (outgoing) | — | — | — | 5,63,916.16 | |
| — | 2.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of front operated double door typeweather proof feeder pillar made of CRCA steel sheet having IP 65 protection (MCCB - Incoming &MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Havells, Siemens, L&T,Schneider, Legrand or equivalent conforming to IEC 60947 & IS/IEC:61439 or latest with digitalmeasuring instrument & bus-bar arrangement and as per latest IS, IE rules and site requirement. Itshould be dust and vermin proof and powder coating as per IS 13871-2021 (or latest version) & asper Explanatory Note. a) 4P MCCB 400Amps 36 kA with adjustable thermal & fixed magnetic release=01 Nos. (Incoming). b) 4P 400 Amps on load change over switch (COS)=01 No. c) 4P MCCB250Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). d) 4P MCCB125Amps 36 kA with adjustable thermal & fixed magnetic release =04Nos. (Outgoing). | — | — | — | 8,47,462.5 | |
| — | 700.00 | — | — | ||
| Supply installation, testing and commissioning of 4 core 2.5 sq mm upto 1100Vgrade, PVC insulated, FRLSH ISI marked, multi stranded, copper conductor flexible cable conforming to IS:694 at all Amrit station with loading, unloading safety with testing of air- conditioner | — | — | — | 1,40,000 | |
| — | 40.00 | — | — | ||
| Supply erection testing and commissioning of Flexible LEDstrips IP 65 rating with optimum brightness & uniformity of light for perfect/coverage/ Facadel igthing of fixture size 5mtr with suitable driver. | — | — | — | 65,696.4 | |
| — | 25.00 | — | — | ||
| Supply, fixing, testing & commissioning of 63A, 30mA DP RCCB AC type, 10KA short circuit withstand capacity, for water cooler | — | — | — | 73,378.25 | |
| — | 100.00 | — | — | ||
| Supply & erection of 1A MCB in existing octagonal pole (IEC 60947) | — | — | — | 21,027 | |
| — | 500.00 | — | — | ||
| Supply & installation of safety wire of SS (IS:302 Part 2 Sec-80) for existing ceiling fan | — | — | — | 13,480 | |
| — | 2.00 | — | — | ||
| Shifting, dismantling & commissioning charges of LT panels, Transformers etc. | — | — | — | 97,008.18 | |
| — | 500.00 | — | — | ||
| Fabrication of MS stand/cabinets or any other MS structure - cutting, welding, riveting, nut bolts, primer & one coat paint | — | — | — | 60,500 | |
| — | 150.00 | — | — | ||
| Design, Manufacturing, supply,fixing, testing andcommissioning of single sided "3D" character Back lit LED typeSignage (station name board)as per CEE/NR Specificationno.CEE /NR/ 121-Elect /PS/2017 Rev 2 dated26.09.17.2017 and technicalscope of work. Note:-Static/Single sided board ofdifferent size and message arerequired. Prior approval ofmessage colour and size to betaken from competent authority | — | — | — | 3,59,242.5 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
IRSConditions2025Latest_compressed_compressed1.pdf
ATTACHMENT
ExplanatoryNotesFinal01.pdf
ATTACHMENT
IndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_4.pdf
ATTACHMENT
TECHSPEC-I.pdf
ATTACHMENT
TECHSPEC-II.pdf
ATTACHMENT
2025_06_24SeekingclarificationonapplicabilityofGCCCorrectionSlipNo_10.pdf
ATTACHMENT
correctionslip4.pdf
ATTACHMENT
correctionslip5.pdf
ATTACHMENT
correctionslip6.pdf
ATTACHMENT
correctionslip7.pdf
ATTACHMENT
correctionslip8.pdf
ATTACHMENT
GCC-2022ACS-2_13.12.2022.pdf
ATTACHMENT
GCC-2022.pdf
ATTACHMENT
GCC-2022ACS-I_July-2022.pdf
ATTACHMENT
2023_04_26RBCE_CE-I-CTIndianRailwaysStandardGeneralConditionsofContractApril-2022AdvanceCorrectionSlipNo_3ACS-311.pdf
ATTACHMENT
correctionslip9.pdf
ATTACHMENT
correctionslip10.pdf
ATTACHMENT
2026_03_13IndianRailwaysStandardGeneralConditionsofContractApril2022AdvanceCorrectionSlipNo_1111_compressed.pdf
ATTACHMENT
Specialcondition30-R.pdf
ATTACHMENT
30-Rtenderdocsigned.pdf
ATTACHMENT
ExplanatoryNotesFinal01.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .