Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-Finance | ₹1.3 Cr | L1 | Accepted-Finance being L1 |
| Sl No | Description | Qty | Unit | KAKOLIL TRADE AGENCIES L1 |
|---|---|---|---|---|
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | ||||
| 1.10 | All kinds of soil. | 124.82 | cum | 500 ₹62,410 |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. | 26.59 | cum | 100 ₹2,659 |
| 3.00 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. | 75 | cum | 1,000 ₹75,000 |
| 4.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 500 | sqm | 10 ₹5,000 |
| 5.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | ||||
| 5.10 | 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 46.97 | cum | 10,000 ₹4,69,700 |
| 5.20 | 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 15.53 | cum | 9,000 ₹1,39,770 |
| 6.00Centering and shuttering including strutting, propping etc. and removal of form work for: | ||||
| 6.10 | Foundations, footings, bases for columns | 5.2 | sqm | 400 ₹2,080 |
Tender Value
₹57.0 L
EMD Value
₹1.1 L
Closing Date
12 Jan 2026, 3:00 pmClosed
EE,CD-III,APWD,Prothrapur
O/o EE,CD-III,APWD,Prothrapur
Construction of Faecal Sludge Treatment Plant FSTP of capacity 5KLD at Chouldari under AE II CD III APWD Prothrapur.
2026_APWD_21312_1
NIT No.09/EE/CD-III/2025-26
Open Tender
Civil Works - Others
240 days
chouldari
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹1.1 L
20 Jan 2026
2 Jan 2026
13 Jan 2026
3 Jan 2026
12 Jan 2026
3 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for:
Foundations, footings, bases for columns
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M30 grade with minimum cement content of 350 kg /cum
All works above plinth level upto floor V level
Concrete of M30 grade with minimum cement content of 350 kg /cum
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
G.I. pipes
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500- 600mm)
12 mm cement plaster of mix:
1:4(1 cement: 4 fine sand)
12 mm cement plaster finished with a floating coat of neat cement of mix:
1:4(1 cement: 4 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade:
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade:
Two or more coats on new work
Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge.
Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade
Providing and laying hollow cement concrete block walling 200mm thick consisting of hollow block size 400x200x200mm of mix 1:3:6 (1cement: 3 coarse sans : 6 graded stone aggregate 20mm nominal and down size) lain in cement mortar 1:6 (1 cement : 6 coarse sand).
Providing and fixing precoated galvalume(PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel everest industries Ltd.,JSW steel lts. Jundal India Lts. or equevalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping luminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing filter media with 2 to 12mm stone chips laid for sludge drying bed including carriage, filling all complete.
Construction of Faecal sludge treatment plant (FSTP) of capacity 5KLD at Chouldari under AE-II, CD-III, APWD, Prothrapur. Sub Work:- Providign IEI, EEI, machinery & equipments and DG set.
AbstractC Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required
Supplying, Installation, Testing and Commissioning of 28W BLDC Ceiling Fan (1200 mm), Sweep ISI Marked without regulator with all accessories etc as required, Make: Havells Model No. Efficiencia DX BLDC or its equivalent etc., as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying of Exhaust Fan (Non Metallic Type) 250 mm sweep with accessories etc as equivalent to Havells Model Venti Air DX or its equivalent as required
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) Upto 450 mm sweep
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including onnections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Supplying of LED 9W Bulb in the existing Batten Holder LED 9W Bulb as Similar to Philips Cat : 85395200 or its equivalent make as required.
Supplying, Installation, Testing and Commissioning of CRCA housing Box type Luminaries suitable for T8 LED Tube (1 x 18 / 20W) as equivalent to Bajaj Model No. BLRB - DB 118 or its equivalent make as required
Supplying of 20 W LED Tube light with polycarbonate housing designed for high performance as equivalent to Bajaj: Model No. BLRB 20W LED or its equivalent make as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required a) Single Pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way, Double Door
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2 mtr, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok) Note: Proof / Test Certificate should be enclosed)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
AbstractD Supplying of 65mm Dia B Class G.I Pipe of Length 6 Mtrs (Standard legnth) having welded 40mm Dia B class G.I Bend pipe at the top to fix Street light fitting and 1 No. 300mm x 300mm x 6 mm base plate at the botton for grouting in the contrete foundation including providing of cable entry pipe of size 50mm dia B class G.I pipe etc. as required
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. (a) Above 4.5 metre and upto 6.5 metre
Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 2 x 1.5 sq. mm
Supplying and fixing of SMC Junction Box of Size 140 mm x 140mm x 95mm ( inside ) suitabily embeded on the cement concrete collar and providing and fixing 1 No. 63 amps Four pole heavy duty SMC connector and 6 Amps SP MCB inside the SMC box including connection etc as required.
Supplying and fixing of 30w LED street light fitting similar to Luker make product code LSTE-30 on the existing street light pole i/c connection etc as required.
Supplying and Laying of following one Number Double walled corrugated high density polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS: No. 14930 Part I & II complete with necessary HDPE fitting for protection of 1.1 KV grade directly in ground at the depth of 50 cm i/c excavation & refilling the trench etc as required. a)50 mm outer dia and 38 mm inner dia
Supplying and Laying of following one Number Double walled corrugated high density polyethylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS: No. 14930 Part I & II complete with necessary HDPE fitting for protection of 1.1 KV grade directly in ground /clamping on wall surface etc as required. a)50 mm outer dia and 38 mm inner dia
Supplying of following sizes of XLPE insulated Heavy duty armoured aluminium conductor UG Cable of 1.1 KV Grade conforming to IS: 7098 (part-I) and IS No. 1554 (part-I) 1988 as applicable Make: CCI/ GLOSTER/ Havells/ Polycab/ Finolex. a) 16 Sqmm x 4 Core (M.S)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL or DWC pipe as required.
a) Upto 35 sq. mm
b) 25 Sqmmx 3 .5Core
Supplying and making end termination aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
a)4 x 16 Sqmm ( 28 mm)
b) 3.5x 25 Sqmm ( 28 mm)
Provision for External service connection from the electricity department
AbstractE Supply, Erection/construction, installation, testing, commissioning and satisfactory trail runs of advance fully automatic (Having micro processer-based control unit with IOT/intranet/internet web access, remote monitoring capabilities 5KLD capacity faecal sludge treatment Plant (FSTP) of any suitable open technology being adopted anywhere in india for primary, secondary & tertiary/any other treatment of faecal effluent meeting the standards prescribed by the MOEF & CC, Gol/CPCB/ANPCC as amend to date with treatment/reuse/safe disposal of sludge. The work including all civil, plumbing, mechanical, electrical & Instrumentation works along with spares wherever required as approved by Engineer in charge including 3 years of operation & amintenance of FSTP including deputation of technical manpower for testing, operation & monitoring/suervision of plant.
Supplying, Installation, Testing and Commissioning of 10 KVA Diesel Generator Set with Water Cooled, Electric Start Diesel engine directly coupled with AC alternator 03 Phase, 415 Volts, 50 Hz @ 0.8 p.f, self excited, self regulated designed to run at 1500 rpm mounted on common base frame, standard control panel, integral fuel tank with 12V, 100 AH Battery and leads and accessories in all respect with CPCB approved acoustic enclosure similar to Generator Set of Make Ley power etc., as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
Supplying and fixing of 63A Four pole onload Changeover switch with side handle in Sheet Steel Enclosure complete as required
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.11 MB
Tendernotice_2.pdf
PDF • 4.80 MB
BOQ_22544.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid