Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹39.3 L Quoted ₹40.4 L | L1 | Accepted-AOC QUOTED AMOUNT IS REASONABLE |
| 2 | L2₹46.1 L+₹5.7 L (14.2%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | ₹46.1 L+₹5.7 L (14.2%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | Rejected-Technical N A | NEW DELHI | DELHI | 110001 | - | - | Rejected-Technical NOT FOUND IN ORDER |
| 4 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | - | Rejected-Technical NOT FOUND IN ORDER |
| 5 | Rejected-Technical PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | - | - | Rejected-Technical NOT FOUND IN ORDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Mar 2025, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
COMPREHENSIVE MAINT CENTRAL AC PLANT AIR HANDLING UNIT COOLING TOWER AND CONNECTED MISC E M WORK AT CGDA HQ AND CENTRAD COMPLEX UNDER GE EAST DELHI CANTT 10
2025_MES_698578_1
CWE/D-72/2024-25
Open Tender
Civil Works
Item Rate
330 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE EAST DELHI CANTT
₹90,000
24 Jun 2025
19 Feb 2025
28 Mar 2025
19 Feb 2025
26 Mar 2025
12 Mar 2025
Amount
Comprehensive/ routine maintenance of Two Nos Chillers of 190 TR capacity having each chiller unit through OEM ,Chiller Model:- 30HXC190A Make:- CARRIER , Ser No HJ1118 & HJ1116 ,AC plant for per months including complete overhauling work through OEM complete all as specified and directed by Engg -in-charge.
Comprehensive/ routine maintenance of One Nos Chiller unit of capacity 210 TR through OEM ,Chiller Model:- LCW1-210V082525 Make:- Blue Star , Ser No VF08 AR1220281M3 , AC plant for per months including complete overhauling work through OEM complete all as specified and directed by Engg -in-charge.
Note for item no 1 & 2 -: (i) Water and Electric required for operation of plant shall be provided free of cost by the Department. (ii) After handing over of plant to contractor . Contractor shall fully responsible for satifactory performance of plant parameters during complete duration of contract period. During Comphensive maintance period any type of fault ( Major & Minor ) occurs in chiller plant contractor shall attend and rectify it without cost . No payment is admisible in this account to contractor. (iii) Contractor shall procure and provide all day to day consumable items such as refrigent gas and grease, sensors, electrical and electronic cards, control and power wirings, lugs sundry items etc reqired for operation of chiller AC plant shall be provided by contractor at his own cost . The quoated rate also include the periodical descaling of condenser coil , chemical cleaning of cooling tower fins and filters as per OEM recommendations and direction of GE during the period of defect liability . The cost of the same shall be deemed included in the unit rates quoted by the contractor. (iv) Contractor should produce MOU of agreement between OEM (carrier and Blue Star) & contractor firm from Whom contractor should carry out the comprehensive maintenance of compressor for 11 months time after completion of overhauling work. The After due varification from OEM chiller plant shall be handed over to contractor for comprehensive maintenance for 11 months.
(v) In case contractor fails to attend fault within 24 hr after intimation by the department , he shall be liable to bear the recovery @ Rs 3000 /- per Hr and department shall rectify the fault through other agency on contractor risk and cost and amount shall be recovered from contractor dues. (vi) Tradesman will take all preventive measures as per code of practice of EI Rules and the Department will not be responsible for any type of untowards incident. (vii) Contractors shall provide all kind hand tools,tester, test lamp without any extra cost as per OEM recommendations.
M&L for taking out Condenser Motor 25HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end , non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa
M&L for taking out Chiller Plant Primary & Secondry Motor 20 HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa
Material and Labour for dismantling of existing Air Handling Unit of any capacity upto 32000 cfm , cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding / brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 guage thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nut, bolt, washer and other packing material etc, with and including testing, commissioning of Air handling Unit at optimum efficiency, complete all as directed by Engineer -in-charge.
S&F in replacement AHU fan belt of Size B-82 complete as specified and directed by Engineer-in-charge. Make: ECODRIVE/ DUNLOP/ Fenner
S&F in replacement AHU fan belt of Size B-101 complete as specified and directed by Engineer-in-charge. Make: ECODRIVE/ DUNLOP/ Fenner
S&F in replacement AHU fan belt of Size B-116 complete as specified and directed by Engineer-in-charge. Make: ECODRIVE/ DUNLOP/ Fenner
S&F in replacement AHU fan belt of Size B-124 complete as specified and directed by Engineer-in-charge. Make: ECODRIVE/ DUNLOP/ Fenner
S&F in replacement AHU fan belt of Size B-138 complete as specified and directed by Engineer-in-charge. Make: ECODRIVE/ DUNLOP/ Fenner
S&F in replacement AHU fan belt of Size B-145 complete as specified and directed by Engineer-in-charge. Make: ECODRIVE/ DUNLOP/ Fenner
S&F in replacement AHU fan belt of Size B-146 complete as specified and directed by Engineer-in-charge. Make: ECODRIVE/ DUNLOP/ Fenner
Supply and fix in replacement of industrial type mercury thermometer complete all as specified and directed.
M & L in replacment of unserviceable 2/3 way modulating motorized valve including actuator, Thermostate, LED Display with temperature display,GI globe body, Brass seating,SS-304 spindle ,Telflon gland,with linear movement actuator 24V AC input supply, 0-10V input signal with modulating thermostate & transformer of size-40 mm Make:-SIEMENS/ RAPID CONTROL/RAPID COOL
M & L in replacment of unserviceable 2/3 way modulating motorized valve including actuator, Thermostate, LED Display with temperature display,GI globe body, Brass seating,SS-304 spindle ,Telflon gland,with linear movement actuator 24V AC input supply, 0-10V input signal with modulating thermostate & transformer of size-50 mm Make:-SIEMENS/ RAPID CONTROL/RAPID COOL
M&L for taking out Cooling Tower Motor 10HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including,bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and from transportation for workshop and vice versa
M&L dismantalling AHU induction motor from AHU base plate inside and arranging the necessary adjusting from fan belt, and then repairing /servicing AHU Fan Motor, following capacity given as under, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa.
7.5 HP AHU fan motor, 1454 RPM, HX+132MLE4 Make-ABB
10 HP AHU fan motor, 1450 RPM, HX+132MLE4 Make-ABB
12.5 HP AHU fan motor, 1455 RPM, HX+160MLB4 Make-ABB
15 HP AHU fan motor, 1450 RPM, HX+160MLE4 Make-ABB
20 HP AHU fan motor, 1450 RPM, HX+160MLE4 Make-ABB
Material & Labour for rewinding of electric motor 1.5 /2 HP, 415 volts, three phase, using Super enameled copper winding wire of gauges equal to or more than existing including replacement of sheet 'E' class insulation and sleeve Including the following jobs (a) Reassembling the motor & refixing (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and directed by Engineer-in-charge.
Material & Labour for rewinding of electric motor 1.5 HP, 240/230 volts, single phase, using Super enameled copper winding wire of gauges equal to or more than existing. Including replacement of sheet 'E' class insulation and sleeve Including the following jobs: (a) Reassembling the motor & refixing (b) Cleaning washing ball bearing with kerosene Oil, greasing with new grease of make Castrol Refixing to its original position testing and Commission complete all as specified and directed by Engineer-in-charge.
S&F Float valve assembly of any size as required in cooling tower complete all as specified and directed.
Supply only PVC spray assembly / Nozzels of any size in cooling tower as required complete all as specified and directed.
S&F fan blade assembly of cooling tower of cooling tower 225TR capacity as per existing assembly including dismantling old unserviceable blades complete all as specified and directed.
S&F PVC Fills complete all as specified and directed by Engineer -in-charge.
Repair & Replacement of Spray Header for 200/225TR Cooling tower complete all as specified and directed.
Supply & fixing in replacement Start/ stop Button for Starter Pannels as required at site. Make: L&T or equivalent make as approved by E-in-C.
Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 9-15A. Model MN2. Make L&T or equivalent in Legrand
Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 14-23A. Model MN2. Make: L&T or equivalent in Legrand
Supply & fixing in replacement thermal overload relays type MN directly operated & direct mounting on MNX, of relay range 20-33A. Model MN2. Make : L&T or equivalent in Legrand
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 12. Make: L&T or equivalent
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starte pannel. Model MNX 18. Make : L&T or equivalent
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 25. Make : L&T or equivalent
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 32. Make : L&T or equivalent
Supply & fixing in replacement Power Contactor type MNX of size Fr1, suitable for existing starter pannel. Model MNX 40. Make : L&T or equivalent
M&L for taking out Vertical Motor 2.5HP Capacity 3 phase 415 volt opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including,bearing insulating materials, varnishing, drying, replacement of both driven end.non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge Note: The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa
M&L for taking out Vertical Motor 5HP Capacity 3 phase 415 volt opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including,bearing insulating materials, varnishing, drying, replacement of both driven end.non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge Note: The quoated rates must incl. loading & unloading with to and fro transportation for workshop and vice versa
S&F in replacement MCCB, 4 Pole, 63 Amps, 415 Volts, adjustable type with breaking capacity 16 KA complete all as specified and as directed.
S&F in replacement MCCB, 4 Pole, 100 Amps, 415 Volts, adjustable type with breaking capacity 16 KA complete all as specified and as directed.
S&F in replacement MCCB, 4 Pole, 125 Amps, 415 Volts, adjustable type with breaking capacity 16 KA complete all as specified and as directed.
S&F in replacement MCCB, 4 Pole, 160 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed.
S&F in replacement MCCB, 4 Pole, 200 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed.
S&F in replacement MCCB, 4 Pole, 250 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed.
S&F in replacement MCCB, 4 Pole, 400 Amps, 415 Volts, adjustable type with breaking capacity 36 KA complete all as specified and as directed.
S&F in replacement MCCB, 4 Pole, 630 Amps, 415 Volts, adjustable type with breaking capacity 50 KA complete all as specified and as directed.
M&L for servicing/ Maintenance & repairing of 1100 V, LT ACB panels including dusting, oiling, setting of over current and earth fault relay, if required, laid and servicing like all mechanical function including replacement of no volt coil tripping device complete all as specified and as directed.
S&F in replacement Air Circuit breakar 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1250 Amps complete all as specified & directed.
S&F in replacement Air Circuit breakar 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 1000 Amps complete all as specified & directed.
Comprehensive maintenance and repair 750 KVA DG Set with AMF of CGDA including replacement of defective parts/fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make- Cummins. Engine No. 25341419, Mode No. KTA-38-62-I.
Comprehensive maintenance and repair 320 KVA DG Set with AMF of CENTRAD including replacement of defective parts/fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make -Mahindra. Engine Model- mpower63905F. Ser No. KENZH01587.
Comprehensive maintenance and repair 250 KVA DG Set with AMF of CGDA including replacement of defective parts/fitting inclunding all required electrical and mechanical Spares required for comprehensive maintenance during the entire contract period of utility press. Make - Cummins, Engine Ser No K125763857 Model- 6CTAA-8.3-64.
Note for Item no 52 to 54 - AMC quoted rates will include Complete servicing of each DG set at starting of the contract, All filters Oil filter,fuel filter,Air filter should be replaced at servicing work of Dg sets. complete Engine Oil & coolant will also be replaced in servicing work. (6 Plan + 4 Nos Breakdown visit If require. In a Calendar year and covered panel side, contactor, relay, battery charger, under voltage relay, over voltage relay, and engine side fuel filter, oil filter, air filter-1set , self starter, hose pipe set, clip, controller etc. for each dg sets including service charges for 11 month each DG set.
S&F in repair fuel pipe set suitable for 750KVA, 320 KVA, 250 KVA DG set complete all as specified and directed.
S&F in replacement battery, SMF, 12 Volt,180AH capacity complete all as specified and as directed. Make -Exide/Amaron/Amar raja or equivalent
S&F in replacement battery, SMF, 12 Volt,150AH capacity complete all as specified and as directed. Make- Exide/Amaron/Amar raja or equivalent
S&F in replacement battery lead with stranded copper conductor of size 95/70 Sqmm, single core, PVC insulated, flexible, 0.6 M long along with battery terminal for positive and stator terminal duly soldered complete all as specified and as directed.
S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 750 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No SF94437 or Equivalent Model of Seimens/Schinder
S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 320 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No SF94437 or Equivalent Model of Seimens/Schinder
S&F in replacement fuse base suitable for cylindrical/DIN type HRC/HBC fuse link type 630/400 A for AMF panel for 250 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No SF94435 or Equivalent Model of Seimens/Schinder
S&F in repalcement power contactor series CK- 3 pole, AC control 630 A, suitable for AMF panel of 750 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No CS96327 or Equivalent Model of Seimens/Schinder
S&F in repalcement power contactor series CK- 3 pole, AC control 400 A, suitable for AMF panel of 320 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No CS96327 or Equivalent Model of Seimens/Schinder
S&F in repalcement power contactor series CK- 3 pole, AC control 250 A, suitable for AMF panel of 250 KVA DG Set complete all as as specified and as directed. Make : L&T Cat Part No CS94141 or Equivalent Model of Seimens/Schinder
S&F in replacement single Phase Preventor as per sample complete all as specified & directed. Make : Minilec Model No VSP-2 or Equivalent Model of L&T/Seimens
S&F in replacement Engine Starting Relay as per sample at site complete all as specified & directed. Make Minilec/L&T/Seimens
S&F in replacement On-Delay timer of 230 VAC, Range: 0 to 30 sec complete all as specified & directed. Make:L&T Cat No ST803280000 or Equivalent Model of BCH/Seimens/Legrand
S&F in replacement Under Voltage relay 240/415 Volt as per sample at site complete all as specified & directed. Make: L&T Cat No Equivalent Model of BCH/Seimens/Legrand
Supply, laying & connecting in replacement single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 56/0.30, flexible, 4 Sqmm complete all as specified & directed.
Supply, laying & connecting in replacement single core, copper conductor, PVC insulated, unsheathed, 1100 V grade (FRLS), 84/0.30, flexible, 6 Sqmm complete all as specified & directed.
S&F in replacement single phase under voltage relay 20-110V AC/DC CT Secondry 5A complete all as specifed and as directed. Make L&T Cat Part No MV12AA00X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
S&F in replacement 3 Phase over current, earth fault relay 20-110V AC/DC 4 No programmable complete all as specifed and as directed. Make L&T Cat Part No MC31AAXX000 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
S&F in replacement 3 Phase over current , earth fault relay 20-110V AC/DC CT Secondry 5A complete all as specifed and as directed. Make L&T Cat Part No MRP11A50X00 or equivalent Model of Seimens/Schinder or any other Make mentioned in PS.
M&L for replacement leakage of cooling towers, fins, base plate by replacing ms sheet or through welding work complete all as specified and as directed. Note - Painting of connecting pipeline & valves shall be include in quoted rates.
M&L for painting of cooling tower complete assembly by cleaning the surface of cooling tower by rubbing with emery Paper to remove oil stains, dust etc and applying one coat of red oxide primer & after that two coat of existing colour synthetic enamel paint complete all as specified and as directed. Note - Painting of connecting pipeline & valves shall be include in quoted rates.
Supply, assembly and erection in replacement GI sheet with C & SS rectangular/ square duct made out of 'L' shaped hollow profile, duly factory boxed, including all accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc complete including necessary MS Channels, gurder supports as approved by Engr-in-Charge including making of hole in any type of wall and making good with plastering work, masonry work and necessary MS channel supports complete all as specified and directed
24 Gauge GI Sheet
22 Gauge GI Sheet
Supply & erection in replacement 19 mm thick nitrile duct thermal insulation with Aluminium foil, non-fibrous, fire retardant, closed cell, tri- dimensional, chemically cross linked polyethylene foam, confirm to class O' for fire propagation and class 1 for surface spread of flame & factory laminated aluminium foil complete all as specified and as directed.
New Era Engineers (BID ID -3271568)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .