Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹13.7 L+₹1.6 L (13.6%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹15.9 L+₹3.8 L (31.2%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹16.5 L+₹4.4 L (36.3%)Rejected-AOC ESD NO II UHL STAGE III BVPCL CHULLAH | LANGNA | MANDYA | KARNATAKA | 571401 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹17.5 L+₹5.4 L (44.8%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹28,900
Closing Date
10 Dec 2020, 10:30 amClosed
Executive Engineer
IPH Division Rohru
SH C o J E Office cum Store at IPH Section Kaloti as per standard design and drawing and C o Retaining wall at front side/Back side of JE Office Kaloti
2020_HPIPH_42738_1
No-IPH-RD-AB-Tender/20 9349-98
Open Tender
Civil Works
Item Rate
180 days
Rohru Town
Tender Document
8 documents required · 8 mandatory
₹400
Yes
EE Rohru
₹28,900
Yes
6 Mar 2021
24 Nov 2020
10 Dec 2020
24 Nov 2020
10 Dec 2020
24 Nov 2020
Amount
Excavation in earth work and disposal of all excavated earth upto a lead of 20mtr. And lift upto 1.50mtr. Disposing earth to be levelled and neatly dressed pick jumper work within all leads and lifts and as directed by the Engineer-in-charge.
Excavation in foundation trenches etc. in earth work lift upto 1.50 mtrs. stacking the excavated soil not more than 3 mtr. Clear from the edge of excavation and then returning the stacked soil in 15cm. Layer when required into plinth sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth all kinds of soil within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cement concrete work 1:4:8(1cement:4approved sand:8approved graded stone aggregate 40mm nominal size) & curingcomplete excluding cost of form work in foundation and plinth with in all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cement concrete work 1:2:4(1cement:2Sand:4Graded stone agg. 20mm nominal size and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
Foundation footing bases oif columns & mass concrete within all leads and lifts and as directed by the Engineer-in-charge.
Columns, pillars, posts and struts upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Suspended floors, roofs, landings and shelves and their supports balconies, beams, girders, bressumers and cantilever upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Providing mild steel/tor steel for RCC work including bending binding and placing in p[osition complete upto floor two level within all leads and lifts and as directed by the Engineer-in-charge.
Providing form work with steel plate 3.15mm thick welded with angle iron frames 30x30x5mmso as give a fair finish i/c centring, shuttering, ¢ring below supporting floor to ceiling not exceeding 4mtrs. &removal of the same for in-situ reinforced concrete & plain concrete work in:
Vertical surface such as wall(any thickness) partitions and the likeincluding attached pillasters, buttresses, plinth and string cources and thelike within all leads and lifts.
Flat surface such as soffits of suspended floor, roofs, landing and the likefloor etc. upto 200mm in thickness within all leads and lifts.
Providing and fixing pressed steel doors frames manufactured from commercial mild steel sheet of 1.25mm thickness i/c hinges jump lock jamb, beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or regidly fixed together by mechanical means, adjustable luge with split and tails to each jamb i/c steel but things 2.5mm thick with guards, lock strike plate and shock as specified and applying a coat of approved steel primer after pretreetment of the surface as directed by the Engineer-in-charge.
Profile-A.
Providing and fixing Pannelled and glazed shutters for doors windows and clear storey windows including black enamel led iron butt hinges with necessary screws 40mm thick: 1st. class deodar wood within all leads and lifts
Providing and fixing wire guage shutter using galvanised MS wire guage of IS guage designation 85G with wire of dia 0.56mm for doors windows and clerestorey windows including bright finished black enamelled iron hinges with necessary screws: 2nd.class deodar wood within all leads and lifts and as directed by the Engineer-in-charge.
Half brick masonry in common burnt clay in super structure above floor two level 1st. Class brick in cement mortar 1:4(1cement:4sand) 1st.class brick within all leads and lifts and as directed by the Engineer-in-charge.
15 mm thick cement plaster on fair sides of brick/stone masonery convrete walls for interior plastering upto floor two level including arises internal rounded angles not exceeding 80mm girth in cm 1:6 (1cement:6sand)within all leads and lifts and as directed by the Engineer-in-charge.
6 mm thick cement plaster in cement concrete 1:3( 1cement 3 sand in roof slabs within all leads and lifts and as directed by the Engineer-in-charge.
White washing with lime on undecorated wall surfaces(two coats) to give an even shade i/c thoroughly brooming the surface to remove all dust dirt & other foreign matter within all leads and lifts and as directed by the Engineer-in-charge.
Distempering with dry distemper of approved brand and manufacture (two coats) and of required shade on undecorated wall surface to given an even shade over and including primer coat of whiting after throughly brushing the surface free from mortar droppings and other foreign matter including preparing the surfce even and sand papered smooth within all leads and lifts and as directed by the Engineer-in-charge.
Applying priming coat over new wood based surfaces after & including perpering the surface by throughly cleaning oil, grease, dirt and other foreign sand papering and knotting(Readymixed paint brushing with white lead for priming) within all leads and lifts and as directed by the Engineer-in-charge.
Painting two coat (excluding priming coat) on new wood and based surface with enamel paint to give an even shade including clearing the surface dirt, dust and other foreign matter sand papering and stoping with white enamel paint within all leads and lifts and as directed by the Engineer-in-charge.
Providing 40x3 mm flat iron hold fast 40cm. Long including fixing to frame with 10mm dia metres bolts, nuts and wooden plug and embedding in cement concrete block 30x10x15cm. 1:3:6( 1cement:3sand:6 graded stone att. 20mm nominal size) within all leads and as directed by the Engineer-in-charge.
Providing and fixing anodized aluminium sliding door bolts withnuts and screws complete I) 250mmX16mm within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing milld steel handles with screws etc. complete within all leads and lifts and as directed by the Engineer-in-charge.(100mm dia)
Providing & fixing tower bolt (bared type) with screws etc.complete within all leads and lifts and as directed by the Engineer-in-charge.(150x10mm)
Stone filling behind retaining wall & crate wall within all leads and lifts within all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying cemnent concrete 1:6:12 (1cement:6approved sand:12approved graded stone agg. 20mm nominal size(twenty milimetres nominal size) and curing complete excluding the cost of form work in foundation and plinth within all leads and lifts and as directed by the Engineer-in-charge,.
Providing and laying cement concrete 1:5:10(1cement:5sand:10graded stone agg. of 40mm nominal size) with 15% plum and curing complete excluding cost of form work in retaining wall/breast walls the sixe of plums shall usually be 150mm to 300mm within all leads and lifts and as directed by the Engineer-in-charge.
Precast terrazo tiles 20m thick (with marble chipsof specified shadeand of specified laid in floor treads of steps and landingon bed on10mm thick cement plaster 1:6 (1cement6sand) jointed withneat cement slurry mixed with pigment to match the shade of tiles, silvery grey within all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing of MS grill of required patttern in wooden frame of window etc. with MS rounded headed bolts and nuts or by screw: Plain Grill within all leads and lifts and as directed by the Engineer-in-charge.
Providing plinth protection 50mm thick in cement concrete 1:3:6(1cement:3sand:6graded stone agg. 20mm nominal size) i/c finishing the top surface of concrete smooth within all leads and lifts and as directed by the Engineer-in-charge.
Vikram Rithwan Contractor
Balraj
Anil Kumar
Shiwang Shukla
Manish Thakur Govt. Contactor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .