Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹37.3 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹45.1 L+₹6.2 L (15.9%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹53.3 L+₹14.4 L (37.1%)Rejected-AOC | 3 | Rejected-AOC L3 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Jun 2020, 6:00 pmClosed
GE SATWARI
GE SATWARI
REPAIR/MAINT OF PUMPS, MOTORS, STARTERS, VOLTAGE STABILIZERS ETC UNDER GE SATWARI
2020_MES_344946_1
GEJM-41/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE SATWARI
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE SATWARI
₹90,000
Yes
9 Jul 2020
18 May 2020
17 Jun 2020
18 May 2020
15 Jun 2020
1 Jun 2020
Amount
Disconnecting the electrical connection for taking out unserviceable VT Motor any size from the foundation of bore well and other accessories carrying to workshop for repair,after repair VT Motor shifted to the existing bore well and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to and fro workshop is deemed to be included in the quoted rate.
M & L for removing the burnt winding wire of the VT motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap 30 to 40 HP complete all as specified and directed.
Disconnecting the electrical connection for taking out unserviceable VT pump any size from the bore well including column pipe and other accessories carrying to workshop for repair complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Lowering the VT pump any size after repair shifted to in its orignal location joint with column pipe,motor and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed.Note: The cost of transportation from workshop is deemed to be included in the quoted rate.
M & L for Replacement the defactive part of VT pump sets are as under:-
(a) Gun metal impeller
(b) Neck Ring
(c) gland plate
(d) Studs
(e) Stainless steel line shaft 3 metre long
(f) Top shaft 1.5 metre long
(g) Guide spider 6"
(h) Guide spider bush
(j) Stainless steel sleeve
(k) Shaft coupler
(l) Stuffing box
(m) Thrust bearing
(n) B Kulf bush
Disconnecting the electrical connection for taking out unserviceable submersible pump set any size from the bore well including column pipe and other accessories carrying to workshop for repair complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Lowering the servicable submersible pump set any size after repair shifted to in its orignal location joint with column pipe and other accessories connecting to all electrical connection testing and commissioning the same complete all as specified and directed.Note: The cost of transportation from workshop is deemed to be included in the quoted rate.
M & L for strip opening of motor ,taking out roter from stater taking out burnt winding from the stater cleaning the core and rewinding the same with PVC insulated copper wire of existing gauge including other winding material as directed by Engr-in Charge of Cap up to 10 HP
All as per Srl item no 21 here in before but of size 15 HP to 20 HP
All as per Srl item no 21 here in before but of size 25 HP to 30 HP
All as per Srl item no 21 here in before but of size 35 HP to 40 HP
M & L for Replacement the defactive part of submersible pump sets are as under:-
(a) Thrust plate of submersible motor 5 HP to 20 HP
(b) Thrust plate of submersible motor 25 HP to 40 HP
(c) Thrust bearing of submersible motor 5 HP to 20 HP
(d) Thrust bearing of submersible motor 25 HP to 40 HP
(e) Gun metal bushes for submersible motor 5 HP to 20 HP
(f) Gun metal bushes for submersible motor 25 HP to 40 HP
(g) Remetaling,grinding,polishing and balancing of shaft for submersible motor 5 HP to 20 HP
(h) Remetaling,grinding,polishing and balancing of shaft for submersible motor 25 HP to 40 HP
(i) Coupling arrangement with key of submersible motor of cap 5 HP to 20 HP
(j) Coupling arrangement with key of submersible motor of cap 25 HP to 40 HP
(k) Stainless steel shaft of submersible pump of cap 5 HP to 20 HP
(l) Stainless steel shaft of submersible pump of cap 25 HP to 40 HP
(m) Impellers for submersible pump set 5 HP to 20 HP
(n) Impellers for submersible pump set 25 HP to 40 HP
(o) Bowl bush for submersible pump set 5 HP to 20 HP
(p) Bowl bush for submersible pump set 25 HP to 40 HP
(q) Neck ring for submersible pump set 5 HP to 20HP
(r) Neck ring for submersible pump set 25 HP to 40HP
(s) Thrust bearing
Disconnecting the electrical connection for taking out unserviceable centrifugal motor any size from the foundation and other accessories carrying to workshop for repair,after repair centrifugel motor shifted to the existing pump house and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Note: .The cost of transportation to and fro workshop is deemed to be included in the quoted rate.Spare part measured and paid under relivent items
M & L for removing the burnt winding wire of the centrifugel motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap10 to 20 HP complete all as specified and directed.
Disconnecting the electrical connection for taking out unserviceable centrifugel pump any size from the foundation including other accessories carrying to workshop for repair complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Replacement the defactive part of centrifugel pumps Set are as under:-
(a) Replacement of implers of existing size as directed by Engr-in-Charge
(b) Replacement of gland bush including gland packing of existing sizeas directed by Engr-in-Charge
(c) Replacement of ball bearing of existing size as directed by Engr-in-Charge
(d) Replacement of center guide of existing size as directed by Engr-in-Charge
(e) Replacement of pump shaft of existing sizeas directed by Engr-in-Charge
(f) Replacement of neck ring any size as directed by Engr-in-Charge
(g) Replacement of tyre coupling of existing size as directed by Engr-in-Charge
Disconnecting the electrical connection for taking out unserviceable open well submirsable motor from any size from the well and other accessories carrying to workshop for repair,after repair open well submirsable motor shifted to the existing bore well and re installation in orignal position including all electrical connection testing and commissioning complete all as specified and directed. Note: .The cost of transportation to and fro workshop is deemed to be included in the quoted rate.
M & L for removing the burnt winding wire of the open well submirsable motor cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, replacement of bearings and assembling the motor of Cap up to 12.5 HP complete all as specified and directed.
Disconnecting the electrical connection for taking out unserviceable open well submirsable pump any size from the foundation including other accessories carrying to workshop for repair complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to workshop is deemed to be included in the quoted rate.
M & L for Replacement the defactive part of open well submirsable pump Set are as under:-
(a) Replacement of neck ring of existing size as directed by Engr-in-Charge
(b) Replacement of Impellers of existing size as directed by Engr-in-Charge
(c) Replacement of thrust bearing of existing size as directed by Engr-in-Charge
(d) Replacement of rubber bush as directed by Engr-in-Charge
Supply , Installation , Commissioning and testing in replacement of LT Panel Board indoor Type starter for pump house of suitable Size as per IS mounted on angle iron legs imbedded in PCC 1:4:8 block type D-2 (using 40 mm graded aggregates) at pump house , floor mounting ,dust and vermin proof factory made, fabricated out of 2 mm thick CRCA sheet suitable for 3 Phase 415 Volt 50HZ AC Supply with aluminum busbar of as per required rating for 3 Phase and 4 wire system duly insulated with heat shrinkable sleeve as per colour supported on epoxy insulator 01 set common earth bus of 25mm x 4mm at bottom inside panel board with two earth terminal out side panel board ,cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating Grey colour including taking down complete.Make:-Tricolite / Schneider / dvepl / Siemens all as approved and cosisting of following:-
Disconnecting the electrical connection dismantling and removing existing automatic voltage stablizer for automatic operation oil cooled servo controlled type input voltage 260 – 440 V & out put voltage 420 V cap 125 KVA to 200 KVA opening refixing and reinstallation. Note: Replacement repair of parts if any found damaged during repair shall be measured and paid for separately
All as per Srl item no 67 here in before but cap 50 KVA to 63 KVA
All as per Srl item no 67 here in before but cap 75 KVA to 100 KVA
All as per Srl item no 67 here in before but cap but cap of 250 to 400 KVA.
All as per Srl item no 67 here in before but cap but of capacity 630 KVA.
Supply and fixing sensing / control card for voltage stabilizer of capacity 125 to 200 KVA.
All as per Srl item no 72 here in before but cap but cap of upto 250 to 400 KVA.
All as per Srl item no 72 here in before but cap but cap 630 KVA.
Dismantling and Rewinding of dimmer coil with supper enameled copper winding wire including vamishing tapping and insulating material to get same cap 125 KVA to 200 KVA.
All as per Srl item no 75 here in before but cap but cap 50 KVA to 63 KVA
All as per Srl item no 75 here in before but cap but cap 75 KVA to 100 KVA
All as per Srl item no 75 here in before but cap but of cap 250 to 400 KVA.
All as per Srl item no 75 here in before but cap but cap 630 KVA.
Supply and fixing servo motor capacity 10 Kgs, 60 RPM at 240 volt for stabilizer of capacity upto 630 KVA all as directed
Supply and fixing Push buttons as per sample or as directed
Supply and fixing toggle switch Make as per sample or as directed.
M&L dismantling of primary & secondary coils carefully taking out winding wire preparing for rewinding with super enameled copper winding wire of appropriates gauge with alled insulating material vamish the winding with air drying insulating vamish, heat treatment etc complete.
Supply heating and filling of transformer oil EHV grade having dielectric strength not less than 40 KV (Rms) with a 4 mm gap with high viscosity in transformer as per IS-335 of 1983 all as specified and directed.
Replacement of electronic circuit plate complete with DC transformers lete (PCB cold)
Replacement of old zero motor brush with carbon brush holder etc complete
Replacement of old carbon brush with carbon holder etc complete
Replacement of analog Amp meter 0.200 Amps with CTS 96mm square as directed by Engr-in-charge
Replacement of internal wiring with suitable size complete as directed by Engr-in-charge
Replacement of brass studs fixed for input & out put of stablizer with brass nuts of capacity 125 to 200 KVA.
All as per Srl item no 92 here in before but cap but cap 50 KVA to 63 KVA
All as per Srl item no 92 here in before but cap 75 KVA to 100 KVA
All as per Srl item no 92 here in before but cap 250 KVA to 630 KVA
Indicator lamp set (RYB) complete
S&F in replacement of On load Changeover including enclousere with advance neutral 415V, 400Amps, 4 pole including connecting incoming and outgoing connection and testing after making all connection as directed by Engr-in-Charge. Make : Havells / C&S / Standard / L&T.
S&F in replacement of On load Changeover ncluding enclousere with advance neutral 415V, 200 Amps, 4 pole including connecting incoming and outgoing connection and testing after making all connection as directed by Engr-in-Charge. Make : Havells / C&S / Standard / L&T.
Supply and fixing in replacement PVC insulated and PVC sheathed flat submersible cable 16 sqmm 3 core with stranded copper conductor 1100 volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed. Make Polycab/Finolex/Havell,s
Supply and fixing in replacement PVC insulated and PVC sheathed flat submersible cable 25 sqmm 3 core with stranded copper conductor 1100 volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed.
Supply and fixing in replacement PVC insulated and PVC sheathed flat submersible cable 35 sqmm 3 core with stranded copper conductor 1100 volts grade suitable for submersible motors and pumps and making electric connections all as specified and directed. Make Polycab/Finolex/Havell,s
Replacement of following body part (Sr. No.106 to 159) of submersible pump set as directed by Engr-in-charge of Make : Mody , Wilo , ABS
M & L in replacement of sand guard assembely of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of sand guard assembely of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of water filling plug of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of water filling plug of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of bush housing set including bush of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of bush housing set including bush of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of upper housing set of 40HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of upper housing set of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of lower housing set of 40HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of lower housing set of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of mechanical seal of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of mechanical seal of 5HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of seal guide sleeve of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of seal guide sleeve of 05 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of startor assembly along with winding wire of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of startor assembly along with winding wire of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of roter assembly of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of roter assembly of 05 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of cable connector sleeve and spring guide plate of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of cable connector sleeve and spring guide plate of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of thrust bearing base with pad of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of thrust bearing base with pad of 5HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of tie rod/tie bolt of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of tie rod/tie bolt of 05 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of motor base of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of motor base along with inner plate of 05 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of motor base inner plate of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of motor base inner plate of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of diaphragm along with diaphargm spring of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of diaphragm along with diaphargm spring of 05 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of doom nut and "O" ring of 40 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of doom nut and "O" ring of 5 HP submersible Motor as existing make and size or as directed by Engr-in-Charge
M & L in replacement of impeller cover of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of impeller cover of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of multi stage impeller set of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of multi stage impeller set of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of frame of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of frame of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of guide vane of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of guide vane of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of pump barrel of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of pump barrel of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of thrust bearing assembly along with bearing of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of thrust bearing assembly along with bearing of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of rubber bearing of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of rubber bearing of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of pin bolt ,valve, O rubber gasket of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of pin bolt ,valve, O rubber gasket of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of cable guard and filtrating screen of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of cable guard and filtrating screen of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of shaft coupling of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of shaft coupling of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of Haxagonal shaft of submersible pump having discharge 15000 Gln/hr at 80 Mtr head of existing make and size or as directed by Engr-in-Charge
M & L in replacement of Haxagonal shaft of submersible pump having discharge 2000 Gln/hr at 50 Mtr head of existing make and size or as directed by Engr-in-Charge
Supply and fix in replacement of GI Column pipe inside the bore well of size 50 mm both side flange ended in every three mtr along with nut bolt and Washer as directed by Engr-in-charge
Supply and fix in replacement of GI Column pipe inside the bore well of size 100 mm both side flange ended in every three mtr along with nut bolt and Washer as directed by Engr-in-charge
Supply and fix in replacement of MS Column pipe inside the bore well of size 150 mm both side flange ended in every three mtr along with nut bolt and Washer as directed by Engr-in-charge
Supply and fix in replacement of MS tail piece of submersible pump of size 50 mm one side flange ended of existing size and one side of threaded end of existing size as directed by Engr-in-charge
Supply and fix in replacement of MS tail piece of submersible pump of size 100 mm one side flange ended of existing size and one side of threaded end of existing size as directed by Engr-in-charge
Supply and fix in replacement of MS tail piece of submersible pump of size 150 mm one side flange ended of existing size and one side of threaded end of existing size as directed by Engr-in-charge
Supply and fix in replacement of MS tia rod ( U Clamp ) for holding of submersible pump set of size 25 x 6 mm both welded bolt of existing size as directed by Engr-in-charge
Taking out VT Pump including columm pipe from the bore well and shifted to workshop for threading ,cutting of all SS Shaft ,replacement of all guide, bush,sleeve,lock nut,gland cup, etc and making alligement on lathe machine complete as directed by Engr-in-Charge
M& L in replacement of contactor 3 pole with coil voltage 220 volt type MNX 70 Rating complete as directed by Engr-in-charge
M& L in replacement of contactor 3 pole with coil voltage 220 volt type MNX 50 Rating complete as directed by Engr-in-charge
Material and labour for replacement of Contactor 3 pole with coil voltage 220 volt type ML-2.0 rating in automatic starter suitable for 20 HP.
M& L in replacement of single plase preventor 440 volt complete as directed by Engr-in-charge
Supply and fixing in replacement Rubber gasket joint 3 mm thick with 4/6 hole for flanged joint 80 mm dia complete all as specified and directed.
Supply and fixing in replacement Rubber gasket joint 3 mm thick for flanged joint 100 mm dia complete all as specified and directed.
Supply and fixing in replacement Rubber gasket joint 3 mm thick for flanged joint 150 mm dia complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 (40mm graded aggregate ) type C-2 with necessary form work all as specified and directed.
Material and labour for taking out the unserviceable motor vertical turbine cap 40 HP from the foundation, dismantling the motor, removing the burnt winding wire of the motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying and assembling the motor, fixing on site and testing the same all as specified and directed. Note: The cost of transportation to and from the workshop is deemed to be included in the quoted rate.
Material and labour for taking out the unserviceable motor vertical turbine of cap 50 HP from the foundation, dismantling the motor, removing the burnt winding wire of the motor, cleaning the slots for rewinding, and rewinding the motor with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, and assembling the motor, fixing on site and testing the same all as specified and directed. Note: The cost of transportation to and from the workshop is deemed to be included in the quoted rate.
Material and labour for disconecting the electric connections of the VT motor 40 HP Make Jyoti, taking up the motor from the foundation and dismantling the rotor from the stator, taking out the defective/ damaged bearings and supply and fixing the new thrust bearings No. 7220 - 2 Nos and ball bearing No 6311 as existing and greasing the bearings,assembling the motor, fixing on foundation and making electric connections and testing on completion all as specified and directed.
Material and labour for disconecting the electric connections of the VT motor 50 HP Make Jyoti, taking up the motor from the foundation and dismantling the rotor from the stator, taking out the defective/ damaged bearings and supply and fixing the new thrust bearings No. 7220 - 2 Nos and ball bearing No 6311 as existing and greasing the bearings,assembling the motor, fixing on foundation and making electric connections and testing on completion all as specified and directed.
M&L for redevelopement of Tube well with air compressor of adequate capacity (not less than 250 cfm) till the avilability of sand free clear water, subject to minimum 24 Hrs of operation of air compresssor. (rate shall include lowering, Unlowering of submersible pump, transportation of necessary T&P, filling, jointing and drainage of adequate size of air compressor as specified and directed.)
Supply only Altoc GP ( Calcium based granullar disinfectant for water treatment) in platsic drum packing of 45 KG all as specified and directed. Make: Purichlor /Declibac Technologies Pvt Ltd /Aquafresh
Supply and fix plastic cylinderical sealed disposable sanitizer refil for disinfection of drinking water with arrangement for controlled release suitable for operation in pressurized line all as specified and directed. Make-Purichlor /Declibac Technologies Pvt Ltd/ Pearl.
Supply only chlorine test kit with coloured ample complete with all testing fitment and OT solution in Rexene finished box all as specified and directed.
Supply only PH test kit with coloured ample covered under BTB (range 6.0 to 7.0) or phenol red (range 6.8 to 8.4) with necessary fitment and 100 ml testing solution in Rexene finished box all as specified and directed.
Supply & fixing Fire extinguisher ABC type cap 6 KG alongwith nozzle and hose all as specified and directed.
M/S S K Electricals Regd
BMMJ TRADERS AND ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .