Loading…
Loading…
Tender Value
₹9.1 L
EMD Value
₹18,300
Closing Date
30 Jul 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
12 conditions · 4 needing a document upload
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Scanned copy of valid Trade license or Propitorship Certificate.
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with "Provision of Dual MSDAC in place of DC Track Circuit in dual detection Mode at BZL Station".
EL-HWH-25-21-3543
EL-HWH-25-21-3543
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹18,300
30 Jul 2026
7 Jul 2026
16 Jul 2026
109 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 9,13,934 | ||
| — | — | — | 4,380 | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 15.00 | — | — | |
| — | — | — | 1,630 | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socket and one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 10.00 | — | — | |
| — | — | — | 1,540 | ||
| Wiring of 6/16A 3 pin Plug board consisting with one 16/6A 3 pin plug socket and one 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 4.00 | — | — | |
| — | — | — | 6,800 | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 100.00 | — | — | |
| — | — | — | 6,200 | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 6.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 50.00 | — | — | |
| — | — | — | 11,600 | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 50.00 | — | — | |
| — | — | — | 15,000 | ||
| Wiring of Mainline by 4 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for 03 phases and 01 neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 20.00 | — | — | |
| — | — | — | 1,769 | ||
| Extra cost for conceal wiring in respect to PVC conduit / casing for light, fan, plug, power plug, multi-plug point etc. including make good of wall surface as its original condition | — | 29.00 | — | — | |
| — | — | — | 4,180 | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | 220.00 | — | — | |
| — | — | — | 4,214 | ||
| Extra cost involvement for modular switch, bell push, plug socket, fan regulator, USB point, TV socket etc. with other accessories ( Make of Modular switch, socket, box, cover plate etc. - ABB / Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 43.00 | — | — | |
| — | — | — | 740 | ||
| Fixing, connection, testing and commissioning of indoor LED luminaire fittings with suitable arrangement. ( LED indoor light fitting will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | 208 | ||
| Installation, connection and commissioning of ceiling fan with GI clamps made of GI flat of suitable size and GI nut-bolts ( BLDC Ceiling Fan will be supplied by Railway ) | — | 4.00 | — | — | |
| — | — | — | 5,044 | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door - IP 43 ), 8 way, 1Ph, 240V, 50Hz, complete with 4 nos. SP MCB of current rating from 6A to 32A, 10kA, 240V, 50Hz as per require- ment of load and 1 no. DP RCBO of current rating 40A, 300mA, 10kA, 230V, 50Hz ( Make of MCB, RCBO and Metal Distribu- tion Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 1.00 | — | — | |
| — | — | — | 121 | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 1.00 | — | — | |
| — | — | — | 5,260 | ||
| Supply of MCB DP, 40A, 1Ph, 240V, 50 Hz, 10kA with polycar- bonate distribution box enclosure (IP-65) with polycarbonate trans- parent openable window including fixing, connection, testing and commissioning. ( Make of MCB - L&T/Siemens/ABB/Hager/Legrand/Schneider and Enclosure Board - Grasp/OBO Bettermann/ABB/Schneider ) | — | 4.00 | — | — | |
| — | — | — | 55,066 | ||
| Supply of Vertical TPN DB with MCCB Incomer ( Metal Enclosure with Metal Door - IP43 ), 3Ph, 50Hz, 415V, 8 way per phase, 415V, 50Hz, complete with total 24 nos. SP MCB of current rating from 6A to 32A, 10 KA, 240 Volt, 50 Hz per phase as per requirement of load and one no. MCCB, 4 Pole, ( 40 - 100 ) Amp, 415V, 50Hz, 36kA, ( Ics = 100% Icu ), Microprocessor based release with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection, 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory, 7) Microprocessor protection-based MCCB must have facility of individual 'LSIG' fault indication. ( Make of MCB, MCCB and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 1.00 | — | — | |
| — | — | — | 2,753 | ||
| Fixing, connection and commissioning of above panel with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 1.00 | — | — | |
| — | — | — | 7,691 | ||
| Supply of Dust and vermin proof metal Busbar Chamber made of 16 SWG ( 1.6mm ) MS sheet duly powder coated consisting of 4 nos. tinned copper busbar of each bar of capacity 100 Amp, 4 way, suitable for 415V, 50Hz supply system including all accessories alongwith fixing, connection, testing and commissioning of incoming and outgoing cables glanding, cable socketing and connection with all suitable arrangement. ( Make - Havells / Standard / HPL / C&S / LK (L&T) / Indoasian ) | — | 1.00 | — | — | |
| — | — | — | 3,883 | ||
| Supply of Polycarbonate Junction Box of dimension 280mm x 280mm x 130mm consisting with 1 no 63A 10kA DP MCB, 1 no 100A STUD Type Terminal and 2 nos. Cable glands with Ingress protection: IP66 or higher complete with hinged door with locking arrangement including fixing, connection and commissioning of above Junction Box on AT Mast with GI clamps made of GI flat of size 40mm x 6mm with GI nuts-bolts. ( Make of Junction Box - Grasp/OBO Bettermann/ABB/Schneider ) | — | 1.00 | — | — | |
| — | — | — | 7,600 | ||
| Trenching and laying of cable under ground by soil cutting with covering of cable by sand and bricks / through suitable dia HDPE pipe including supply of HDPE pipe (PE-100 grade, PN- 10 or higher) without bricks alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 50.00 | — | — | |
| — | — | — | 850 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | 7,030 | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make good of floor surface as its original condition after laying of cable ( Cable will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | 400 | ||
| Drawing of cable on wall / structure with suitable size and shape GI clamps including supply of suitable size GI Clamp and GI nut-bolts and commissioning of cable ( Cable will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | 2,060 | ||
| Trenching, laying under road / track through 50 mm dia GI pipe ( medium gauge ) including supply of GI pipe and commi- ssioning of cable including back filling of trench with excavated soil after laying of cable ( Cable will be supplied by Railway ) | — | 10.00 | — | — | |
| — | — | — | 2,595 | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. long GI pipe ( Make - Tata / Jindal / Bansal ) for protection of cable on pole with proper GI clamps and GI nuts & bolts including supply of GI pipe ( Cable will be supplied by Railway ) | — | 3.00 | — | — | |
| — | — | — | 9,372 | ||
| Supply of Maintenance Free Copper Bonded Solid Earthing Rods with 25 kg Earth Enhance Compound with below specifications : a) Certified by CPRI and NABL Accredaited Lab b) ROHS certified c) Low Carbon High Tensile Rod d) Length of Electrode 3000 mm (3 Meter) e) Rod dia 17.2 mm f) Molecular Copper Plating thickness 254 microns as per UL 467 g) Connection terminal size 32 mm x 6 mm with 10 mm hole along with nut bolt and washer including installation, testing and commissioning as per RDSO spec. no. RDSO/SPN/197 ver. 1.0 or latest and conforming to RDSO Drg. No. SDO/RDSO/E&B/001 or latest. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 1.00 | — | — | |
| — | — | — | 659 | ||
| Supply of Heavy Duty Fiber Reinforced Polymers Pit Cover with below specifications : a) Weight Carrying Capacity 5 Ton b) Lockable arrangement c) Top Dia 162 mm d) Bottom Dia 242 mm e) Height 230 mm f) As per IEC 62561-5 g) M5 Nut Bolts HDG 4.6, 30 mm length with 2 nos. of plain washer h) Tested by NABL Accrediated LAB including installation, testing and commissioning. ( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 1.00 | — | — | |
| — | — | — | 4,974 | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by 25 mm X 4 mm Galvanized Iron ( GI ) strip. ( For details not covered in this specifications, Indian Standard Code of Practice for earthing IS : 3043 - 1987, Reaffirmed - 1996 should be followed ) | — | 2.00 | — | — | |
| — | — | — | 2,65,848 | ||
| Supply, Installation, Testing & Commissioning of Variable refrigerant flow (VRF) top / side Discharge Air cooled Type Outdoor units equipped with Full Inverter driven (100%) micro processor base panel highly efficient air conditioning system, comprising compressor DC inverter driven Scroll/ Twin Rotary type with fully factory charged R-410A refrigerent gas & oil, running at 415V±10% - 3 Ph - 50 Hz with ultra low standby power consumption, EER values 3.01 ( Cooling Mode ) at AHRI Conditions (BMS compatible, Web monitoring option). All the units shall be provided with micro processor based control for sequential starting of condensing units, smart tools , advance refrigerant control , Liquid back flow protection, Intelligent Maintenance Tool, precise oil control technology, reverse phase operation, running at 415V±10% - 3 Ph - 50 Hz, condenser made with copper tubes DC fan motor, ODU should have electrical control box with an IP55-rated Design, various electrical protection like-phase sequence, high /low voltage protection, supersense, compressor overload protection, fan & compressor temparature protection & pressure protection . The Outdoor unit also having blue fins with 4 face heat exchanger & capable to run in 52 Deg C. Complete with individual remote controller and centralized controller with easy software programe upgradation for urgent maintenance. ODU having cooling operation only with wide ambient Cooling - 15°C to 52°C -15°C to 52°C, (Here, 1 HP = 1 set) ( Make : O General / Fujitsu-General / Mitsubishi Electric / Panasonic / Samsung / Carrier / Toshiba / LG / Hitachi / Trane / Voltas ) | — | 12.00 | — | — | |
| — | — | — | 1,27,086 | ||
| Supply of High Static Ductable Indoor Unit with nominal capacty 6 HP, Cooling capacity not less than 18 KW, air flow not less than 2058 CFM & sound pressure level not more than 49 db with Touch Panel Remote including installation, testing and commissioning. ( Make : O General / Fujitsu-General / Mitsubishi Electric / Panasonic / Samsung / Carrier / Toshiba / LG / Hitachi / Trane / Voltas ) | — | 2.00 | — | — | |
| — | — | — | 13,980 | ||
| Supply, installation of interconnecting refrigerant pipe copper piping, size 31.75 mm O.D. (With 19 mm insulation ) work with thickness of ( 19 mm/13 mm thick ) closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor and outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger/angle etc. as required as per design and direction of the EIC. (Copper pipe Make : Rajco/ Mandev/Maxflow & Nitrile rubber insulation Make: Armacell / Kflex /Aeroflex). | — | 10.00 | — | — | |
| — | — | — | 8,320 | ||
| Supply, installation of interconnecting refrigerant pipe copper piping, size 28.6 mm O.D. (With 19 mm insulation ) work with thickness of ( 19 mm/13 mm thick ) closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor and outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger/ angle etc. as required as per design and direction of the EIC. (Copper pipe Make: Rajco/ Mandev/Maxflow & Nitrile rubber insulation Make: Armacell / Kflex /Aeroflex). | — | 10.00 | — | — | |
| — | — | — | 5,420 | ||
| Supply, installation of interconnecting refrigerant pipe copper piping, size 22.2 mm O.D. (With 19 mm insulation ) work with thickness of ( 19 mm/13 mm thick ) closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor and outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger/ angle etc. as required as per design and direction of the EIC. (Copper pipe Make: Rajco/ Mandev/Maxflow & Nitrile rubber insulation Make: Armacell / Kflex /Aeroflex). | — | 10.00 | — | — | |
| — | — | — | 5,390 | ||
| Supply, installation of interconnecting refrigerant pipe copper piping, size 19.05 mm O.D. (With 19 mm insulation ) work with thickness of ( 19 mm/13 mm thick ) closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor and outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger/ angle etc. as required as per design and direction of the EIC. (Copper pipe Make: Rajco/ Mandev/Maxflow & Nitrile rubber insulation Make: Armacell / Kflex /Aeroflex). | — | 10.00 | — | — | |
| — | — | — | 5,220 | ||
| Supply, installation of interconnecting refrigerant pipe copper piping, size 15.8 mm O.D. (With 19 mm insulation ) work with thickness of ( 19 mm/13 mm thick ) closed cell elastomeric class-O nitrile rubber tubular insulation between each set of indoor and outdoor units & specifications, all piping inside the room shall be properly supported with MS hanger/ angle etc. as required as per design and direction of the EIC. (Copper pipe Make: Rajco/ Mandev/Maxflow & Nitrile rubber insulation Make: Armacell / Kflex /Aeroflex). | — | 10.00 | — | — | |
| — | — | — | 3,410 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 12.7 mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. (Make: Rajco / Mandev/Royku) | — | 10.00 | — | — | |
| — | — | — | 2,690 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 9.52 mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. (Make: Rajco / Mandev/Royku) | — | 10.00 | — | — | |
| — | — | — | 2,260 | ||
| Supply, installation, testing and commissioning of Interconnecting refrigerant pipe work with 6.35 mm OD with 13mm thick closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units, all piping inside the room shall be properly supported with MS hanger. (Make: Rajco / Mandev/Royku) | — | 10.00 | — | — | |
| — | — | — | 1,160 | ||
| Supply of PVC condensate Drain Piping of 32 mm dia complete with fittings, accessories, bends, elbows, tees, flanges, tappings, hangers, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation including Installation, testing and commissioning. (Make: Supreme / Astral / Finolex / Prakash) | — | 10.00 | — | — | |
| — | — | — | 1,590 | ||
| Supply of PVC condensate Drain Piping of 40 mm dia complete with fittings, accessories, bends, elbows, tees, flanges, tappings, hangers, supports as per specifications and duly insulated with 6 mm thick closed cell nitrile rubber insulation including Installation, testing and commissioning. (Make: Supreme / Astral / Finolex / Prakash) | — | 10.00 | — | — | |
| — | — | — | 6,020 | ||
| Supply of Copper Flexible 4C x 4.0 sq.mm. control cable with conduit and cabling between outdoor VRF and indoor units & to main central remote controller system as per OEM specification bundled properly and neatly aligned with the refrigerant piping with well supported at specific intervals with fasteners including erection, testing and commissioning . ( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 20.00 | — | — | |
| — | — | — | 12,330 | ||
| Supply, installation, testing & Commisioning, Leak testing, nitrogen flusing & hold the pressure for minimum 48 Hour & R410 Gas Charging Top Up in the VRF system as per desired condition to have the system to perform as per design condition | — | 15.00 | — | — | |
| — | — | — | 19,004 | ||
| Supply, fixing, connection, testing and commissioning of MCCB with Microprocessor Release of breaking capacity 36 kA at 415V, AC 50Hz ( Ics = 100% Icu ) with following features :- 1) Adjustable Over Load, 2) Adjustable Short Circuit, 3) Inbuilt ground fault protection, 4) Inbuilt Instantaneous protection 5) Adjustable neutral overload protection, 6) Provision of Thermal Memory 7) All Microprocessor protection-based MCCB / ACB must have facility of individual 'LSIG' fault indication, suitable for Release Range 40-100A, 4 Pole with polycarbonate distribution box enclosure (IP-65) with polycarbonate transparent openable window. ( Make - LK / Siemens / ABB / Hager / Legrand / Schneider / C&S ) | — | 1.00 | — | — | |
| — | — | — | 5,800 | ||
| Supply, erection and installation of fabricated MS Structure comprised of "I" section Beam, 'C' channel, MS flat etc for platform suitable for mounting Outdoor unit including painting including wall cutting, grouting with cement concrete, as per direction of EIC. ( Make - TATA / Jindal / Bansal ) | — | 40.00 | — | — | |
| — | — | — | 5,500 | ||
| Supply, fabrication, laying & fixing in positions with suitable GI angle supports of GI perforated type cable tray for the entire HVAC work with necessary brands, tees and clamps/ couplers for fixing. All material shall be Hot dip galvanized as per specifications. Size : 150 mm wide & 50 mm deep 1.6 mm thick. | — | 10.00 | — | — | |
| — | — | — | 2,892 | ||
| Supply, installation, testing and commissioning of fire retardant flexible canvas connection with flange as per requirement. | — | 2.00 | — | — | |
| — | — | — | 11,520 | ||
| Supply, installation, balancing and commissioning of sheet metal GI site fabricated rectangular duct complete with MS flanges, neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc necessary supports using threaded road and achor bolts, supply air collars, vanes, splitters grillers as per IS 655 and as per specification. Duct will be as per approved drawings and specifications of following sheet thickness complete as required. Size: 24 Gauge GI Sheet. ( Make : Tata / Sail / Jindal ) | — | 12.00 | — | — | |
| — | — | — | 16,326 | ||
| Supply, installation, balancing and commissioning of sheet metal GI site fabricated rectangular duct complete with MS flanges, neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc necessary supports using threaded road and achor bolts, supply air collars, vanes, splitters grillers as per IS 655 and as per specification. Duct will be as per approved drawings and specifications of following sheet thickness complete as required. Size: 22 Gauge GI Sheet. ( Make : Tata / Sail / Jindal ) | — | 18.00 | — | — | |
| — | — | — | 20,706 | ||
| Supplying, fixing, testing & commissioning of powder coated extruded aluminium section supply air grills / square diffuser with volume control dampers as required. | — | 2.00 | — | — | |
| — | — | — | 16,146 | ||
| Supplying, fixing, testing & commissioning of powder coated extruded aluminium section return air grills / square diffuser without volume control dampers as required. | — | 2.00 | — | — | |
| — | — | — | 8,358 | ||
| Supply, erection, testing & commissioning of Aluminium collar damper for controlling and balancing of air distribution. | — | 2.00 | — | — | |
| — | — | — | 18,841 | ||
| Supply and fixing of Three Phase timer panel suitable to 5.5TR - 11TR ductable type AC machine. It should be consisting of Double door TPN DB with 1 no. 40A TP MCB as incommer & 1 no. 40A TP power contactor with 2NO + 2NC auxiliary contact 1 No 24Hrs digital timer switch, 2 Way auto - manual bypass selection switch and 02 nos. indicating lamp with 1 no. 6A SP MCB for control circuit including necessary interconnection and earthing attachment for 3 phase AC machine. ( Make - L&T / Siemens / ABB / Hager / Legrand / Schneider ) | — | 1.00 | — | — | |
| — | — | — | 15,084 | ||
| Supply, Fixing, testing and commssiooning of GI Fusible link fire dampers in supply air duct / main branch as and where required with all accessories. The damper shall also be closed in the event of fire complete as required and as per specifications and atleast 90 minutes rating. ( Make - System Air / Green Air / Air Enterprise ) | — | 2.00 | — | — | |
| — | — | — | 1,39,414 | ||
| Goods & Services Tax ( at present @ 18% ) | — | 1.00 | Lumpsum 139414.00 | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderBooklet.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf Tender form and annexure
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
3543Clause.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf Advance Correction Slip
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .