Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
23 Sept 2022, 5:00 pmClosed
SE EUDC- III (U.P)
Taalkatora power house lesa lucknow
ON SITE Preventive maintenance of medium Power Distribution Transformer 160, 250 400 630 to 1000 KVA) installed at different places in the area of E.U.D.D Aishbagh/UPTRON/Rajajipuram under jurisdiction of E.U.D.C.-III LESA CIS Gomti Lucknow
2022_MVVNL_727864_2
41/E.U.D.C.-III/2022-23
Open Tender
Miscellaneous Works
Fixed-rate
365 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
A/c.No-35140200000129 IFSC-BARBORAJLUC
₹15,000
11 Oct 2022
15 Sept 2022
24 Sept 2022
15 Sept 2022
23 Sept 2022
15 Sept 2022
Amount
Removing Top Cover Plate by opening of Bolt and nuts of T/F and other internal connection of T/F required for repairing safely and reconnect it after appropriately after Minor repairing work of Medium Power Distribution Transformer(l l/O.4 KV) installed at various site for Stopping Oil leakage from T/F, Replacement of Damaged H.T/LT Bushing Rod and other work as per site requirement & site conditions. Firm has to make arrangement for draining and refilling of T/F Oil , if required for carrying out the work.
160, 250 KVA, 400 KVA T/F
630 KVA,800 KVA,990 KVA and 1000 KVA T/F
Toping Up/Filling of Reclaimed T/F Oil in T/F's
T/F Oil in following capacity of T/F's up to 2/3rd level of conservator Tank for Distribution T/F having less Oil as per Indent placed for repairing by JE/SDO. Filling up of these T/F by Reclaimed T/F Oil upto required level and carriage of reclaimed T/F Oil, T/F drums from concerned store/site including safe loading and unloading at both ends. Complete in all respect as per site requirement( Reclaimed T/F Oil will be provided by the concerned JE(D) ( Required Vehicle & suitable Container for storage of Reclaimed T/F Oil will be arranged by the Contractor at his own cost.)
Installation of Silica gel breather whereever required.
160/250/400 K.V.A. - 250 gram.
630/800/990/1000 K.V.A. - 500 gram.
Replacement of Old and Damaged H.T Busihing rod including Oil Seal/Gaskits etc. ( 160, 250, 400, 630 and 1000 KVA T/F)
Removal of Old and damaged H.T Busing Rod from T/F and fixing of suitable size new H.T Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirement, Complete Job in all respect. (All material will be provided by the Department)
Replacement of Old and Damaged L.T Bushing rod including Oil Seal/Gaskits etc. Removal of Old and damaged L.T Busing Rod from T/F and fixing of suitable size new L.T
Busing rod made of Brass with all nuts and bolts etc. including replacement of all old/damaged Neoprene Oil seal/Gasket set by fixing suitable size New Neoprene Oil Seal/Gasket Set & as per site requirement, Complete Job in all respect. ( All material will be provided by the contractor)
Stopping Oil leakage from T/F H.T/LT Bushing side.
Stopping of Oil leakage from T/F L.T/H.T Side Bushing. Removing of all damaged oil Seal/Gasket Set/Cork sheet and fixing of suitable size new Neoprene Oil seal/Gasket set/Cork sheet and tightening of H.T/LT bushing rod Complete Job in all respect. (All material will be provided by the contractor)
Replacement of Old and Damaged LT PVC CABLE (All Material will be provided by Department)
Replace LT Aluminum unarmored XLPE/PVC Cable 3.5x400 Sq.mm Replace LT Aluminum unarmored XLPE/PVC Cable 1X400 Sq.mm Replace LT Aluminum unarmored XLPE/PVC Cable 1X240 Sq.mm
Replacement of Old and Damaged Suitable capacity of Aluminum Lugs (All Material will be provided by Contractor).
Fixing of suitable capacity of lugs after removing old and damaged lugs from various capacity of PVC cable with using crimping tools.
Repairing of Old and Damaged Distribution Box. (All Material will be provided by contractor)
SMC L.T. Distribution Pillar box with one incomer and 3 sets of 300 Amps rewritable type fuse unit for outgoing circuits complete, connected on 800A bus bar.
Provision of fuse unit at LT side To protect transformer by unbalancing and overloading, provision of fuse unit to be installed at LT side with suitable capacity of Fuse assembly ( All Material as fuse assembly, nut bolts etc. will be provided by contractor)
160, 250 KVA KVA T/F
400. 630, 800, 990 KVA and 1000 KVA T/F
Repair and Maintenance of Old and Damaged Transformer Earthing
Maintenance and repair of Transformer Earthing PIPE/ROD are Damaged, in case of missing pole earthing, provision of M.S Rod Of 20x25mm and 6 SWG earthing wire .will be done by new one as per site requirement. Contactor to ensure that earth connection properly should be tight and earth resistance should be less then 01ohm.(All Material Provide by contactor)
Maintenance Repairing Of Damage Plinth
Plinth by Using Bricks ,ballast or sand and Cement. (All Material will be provided by Contactor.
R.D. ENTERPRISES
M/S S.K. CONTRACTOR AND SUPPLIER
S.R. ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .