pvc aluminium cable
pvc aluminium cable Average Turn Over of Last 3 Years 1 Lakh (s) Experience with Gov. Required 2 Year (s) Pvc Aluminium Cable ( 900 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Product description Non Weather proof Unarmoured PVC Insulated Unsheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005 Non Weather proof Unarmoured PVC Insulated Unsheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005
Weather proof Unarmoured PVC Insulated
PVC Sheathed Cable with Aluminium Conductor for working Voltage up 1/7 to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005 BIS Marking Mandatory * BIS CM/L No. - * Cable Size (Sq-mm) 6 * No. of Core (Nos.) Single Single
Twin
Three
Four Type of Cable Circular Flat
Circular Type of Conductor Single Single
Three Strand
Seven Strand
Multistrand CONSTRUCTIONAL Standard cable length sUpplied in coils without negative tolerance (meters) 100 mETRES * Supply of short length quantity against individual supply order Minimum 5 percent * Short length (meters) 95-100 * Nos of Short length in reel (No.) 1 * Sequential Marking of the cable length on each meter YES * CERTIFICATIONS Availability of Test Report from NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specification Suppliers shall submit complete and satisfactory Type Test Certificate for the smallest and the largest sizeof the cable Type tests shall include thermal stability test for insulation and sheath Seperate TTC shall be required for nonweather proof and weather proof cables YES * 2/7 Test Report No. - * Test Report Date - * Name of the Lab - * Address of The Lab - * Test report to be furnished to the buyer on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Prem Kumar Suman 451111
NAGARPALIKA CAMPUS at BUS STAND SANAWAD
451111 900 15 Pvc Aluminium Cable ( 700 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Product description Non Weather proof Unarmoured PVC Insulated Unsheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005 Non Weather proof Unarmoured PVC Insulated Unsheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005
PVC Sheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f 3/7 IS:8130/1984 Reaffirmed 2005 BIS Marking Mandatory * BIS CM/L No. - * Cable Size (Sq-mm) 10 10 No. of Core (Nos.) Twin Twin Type of Cable Flat Flat
Multistrand CONSTRUCTIONAL Standard cable length sUpplied in coils without negative tolerance (meters) 100 mETRES * Supply of short length quantity against individual supply order Minimum 5 percent * Short length (meters) 5 * Nos of Short length in reel (No.) 5 * Sequential Marking of the cable length on each meter YES * CERTIFICATIONS Availability of Test Report from NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specification Suppliers shall submit complete and satisfactory Type Test Certificate for the smallest and the largest sizeof the cable Type tests shall include thermal stability test for insulation and sheath Seperate TTC shall be required for nonweather proof and weather proof cables YES * Test Report No. - * Test Report Date - * Name of the Lab - * Address of The Lab - * Test report to be Yes * 4/7 furnished to the buyer on demand * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Prem Kumar Suman 451111
451111 700 15 Pvc Aluminium Cable ( 900 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Product description Non Weather proof Unarmoured PVC Insulated Unsheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005 Non Weather proof Unarmoured PVC Insulated Unsheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005
PVC Sheathed Cable with Aluminium Conductor for working Voltage up to and including 1100Volt and conforming to IS:694/90 Reaffirmed 2005 Conductor shall conform to table I and II as applicable 0f IS:8130/1984 Reaffirmed 2005 BIS Marking Mandatory * BIS CM/L No. - * Cable Size (Sq-mm) 2.5 2.5 5/7 No. of Core (Nos.) Single Single Type of Cable Circular Flat
Multistrand CONSTRUCTIONAL Standard cable length sUpplied in coils without negative tolerance (meters) 100 mETRES * Supply of short length quantity against individual supply order Minimum 5 percent * Short length (meters) 95 * Nos of Short length in reel (No.) 1 * Sequential Marking of the cable length on each meter YES * CERTIFICATIONS Availability of Test Report from NABL/ILAC accredited or Central Government Lab to prove conformity of products to the specification Suppliers shall submit complete and satisfactory Type Test Certificate for the smallest and the largest sizeof the cable Type tests shall include thermal stability test for insulation and sheath Seperate TTC shall be required for nonweather proof and weather proof cables YES * Test Report No. - * Test Report Date - * Name of the Lab - * Address of The Lab - * Test report to be furnished to the buyer on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity 6/7 S.No. Consignee Address Quantity Delivery Days 1 Prem Kumar Suman 451111
451111 900 15