| Sl No | Description | Qty | Unit | M/S A S CONSTRUCTION L1 | M/s Vinod Construction L2 |
|---|---|---|---|---|---|
| 1.00 | EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. | 2,377.98 | CU.M | 120.36 ₹2,86,213.67 Lowest | 128.82 ₹3,06,331.38 |
| 2.00 | EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I. | 2,335.61 | CU.M | 12.3 ₹28,728 Lowest | 13.16 ₹30,736.63 |
| 3.00FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | |||||
| 3.01 | IN FOUNDATION TRENCHES + FILLING IN OUTSIDE OF BUILDING TO RAISE G.L. = 30% OF TOTAL E/W | 832.71 | CU.M | 43.82 ₹36,489.35 Lowest | 46.9 ₹39,054.1 |
| 4.00 | Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) | 96.78 | CU.M | 358.35 ₹34,681.11 Lowest | 383.54 ₹37,119 |
| 5.00 | Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge | 261.66 | SQ.M. | 284.41 ₹74,418.72 Lowest | 304.4 ₹79,649.3 |
| 6.00 | Providing designation 75-B, one BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge | 18.01 | SQ.M. | 277.96 ₹5,006.06 Lowest | 297.5 ₹5,357.98 |
| 7.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | |||||
| 7.01 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone
aggregate 20 mm nominal size) | 71.74 | CU.M | 3,873.76 ₹2,77,903.54 Lowest | 4,146 ₹2,97,434.04 |
| 8.00 | Providing and filling Autoclaved aerated cement blocks in toilet sunken slab after waterproofing treatment of slab and beam including all taxes all complete. | 1.75 | CU.M | 2,626.72 ₹4,596.76 Lowest | 2,811.32 ₹4,919.81 |
Tender Value
Refer Docs
EMD Value
₹3.5 L
Closing Date
30 Aug 2022, 5:00 pmClosed
NODAL OFFICER
e-Procurement Cell, Jharkhand State Building Construction Corporation Ltd., Beside Jharkhand Mantralaya Dhurwa, Ranchi-834004.
Proposed Construction of Cafeteria Common Room and Underground Parking for Ranchi Women s College at Arts Block Campus, Ranchi
2022_JSBCC_60804_1
JSBCCL/45/2022-23
Open Tender
Civil Works - Buildings
Item Rate
270 days
Ranchi
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
Yes
JSBCCL
₹3.5 L
13 Oct 2022
15 Aug 2022
2 Sept 2022
15 Aug 2022
30 Aug 2022
15 Aug 2022
Amount
EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
IN FOUNDATION TRENCHES + FILLING IN OUTSIDE OF BUILDING TO RAISE G.L. = 30% OF TOTAL E/W
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing designation 75-B, one BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Providing and filling Autoclaved aerated cement blocks in toilet sunken slab after waterproofing treatment of slab and beam including all taxes all complete.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in BEAM with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all complete as per building specification and direction of Engineer Incharge.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing R.C.C. M-20 with nominal mix of 1:1.5:3 in LINTEL BAND with approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M. 2.5 to 3 including screening shuttering, mixing cement concrete in mixer, placing in position vibrating, striking, curing (but excluding the cost of reinforcement) taxes and royalty all comple as per building specificationand direction of E/I.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing, hosting and fixing above plinth level up to floor level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand ), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , exculuding the cost of reinforcement, with 1:1.5:3 (1cement : 1.5 coarse sand (zone-iii) : 3 graded stone aggregate 20mm nominal size)
Providing designation 75A brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing designation 75B brick work in C.M. (1:6) in foundation & plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints,cost of screening materials raking out joints to 15mm depth , curing, taxes & royalty all complete as per building specification & direction of E/I.
Providing designation 75 A BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing designation 125 mm thick REINFORCED DESIGNATION 75 A BRICK WORK in C.M. (1:4) in SUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of Engineer Incharge .
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 6mm cement plaster(1:4) in ceiling with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12 mm thick water proof CEMENT PLASTER (1:6)on outside wall with clean coarse sand of F.M.1.5 and 5% cico including cost of screening, curing making grooves with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I. (Cost of cico will be paid separately)
Centering and shuttering including struting, propping etc. and removal of form for -
Foundation, footings, bases of columns etc.
Columns
shuttering taken @ 14m2/m3
ROOF SLAB
shuttering taken @ 9m2/m3
Beams, plinth beams,-
qty. of r.c.c. in BEAM -
STAIRS -
qty. of r.c.c. in STAIRS -
CHAJJA
qty. of r.c.c. in CHAJJA -
FASCIA
qty. of r.c.c. in FASCIA -
Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (ONLY VALID FOR SAIL & TATA STEEL, JSPL, ELECTRO STEEL LTD. AND VIZAG STEEL)
TOR 8 MMDIA.
TOR 10 MMDIA.
TOR 12 -32 MM DIA.
Providing & fixing FAN HOOK of 16 mm dia M.S. bar, 1 M long bent to required size and shape, placed in position and fluid in the R.C.C. slab-beam at the time of casting all complete as per building specification and direction of E/I. (where material is no)
Supplying, fitting & fixing 250 x 20 x 6 mm L-type M.S. clamp properly fishtailed including making holes and setting the same in 375 x 125 x 75 mm cement concrete block (1:2:4) with cost of all layout and materials and taxes as per building specification and direction of E/I.
Making 20x6 mm grooves in plaster surface over walls trully horizontal or vertical as specified at regular intervals at all heights including cleaning finishing , scaffolding and curing with all leads and lifts of water all complete as per buildinng specification and direction of E/I.
Extra for R.C.C. work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Extra for brick work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
Extra for PLASTER ON OUTER SIDE work for each consecutive floor above first floor including watering and scaffolding, all complete as per direction of E/I.
FLOORING WORKS
Providing and fixinging 18 mm thick mirror polished, machine cut for kitchen platform and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 (1cement :4 coarse sand) laid and jointed with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Providing and fixinging 18 mm thick mirror polished, machine cut for kitchen platform and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 (1cement :4 coarse sand) laid and jointed with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels.
Granite of any colour and shade
Extra for providing edge moulding to Granite stone counters, vanities etc. over above including machine polishing to edge to give high gloss finish etc. complete as per design approved by Architects / E/I.
Providing and laying Double charge VITRIFIED FLOOR TILES in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08% and confirming to IS : 15622/ ISO 13006, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.30 kg/M2 including grouting the joints with white cement and matching pigments etc. complete. Size - 600 mmX600 mm (APPROVED BRAND - DOUBLE CHARGED - ASIAN/ KAJARIA/ SOMANY).
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Marble stone flooring with 18 mm th marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm thick base of cement mortar 1:4 (1cement :4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with:
Extra for pre finished nosing to treads of steps of marble stone
Extra for marble stone flooring in treads of steps and risers using single length upto 2.00 m
Providing and laying 6 mm precast SEMI GLAZED CERAMIC TILES of approved quality in DADO over 12mm cement mortar (1:3) and jointed with white cement slurry flush pointed with white cement including rubbing, polishing and cost of curing taxes, and royalty all complete as per building specification and direction of E/I with grade A coloured 20cmx15cm tiles.
Providing and laying 60 MM th. factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/ shape laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of E/I.
DOORS & WINDOWS WORKS
Supplying , fitting and fixing good quality well dressed and well seasoned sal wood work in chaukhat in doors, windows sky lights, fanlights and C/W celetial windows openings including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface , building walls and lintel all complete as per building specification and direction of El.
Supplying, fitting & fixing 35 mm th. Solid core type non-decorative single leaf FLUSH SHUTTERS IN DOORS and window with black board core blended with high quality phenol formal dehydes synthetic resin both side commercial veneered of standard make with oxidised iron fittings such as hinges, tower bolts , handle,cleats aldrop, door stopper & sand blocks & taxes all complete as per detail drawing building specification & direction of the E/I.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. (Using M.S. angels 40x40x6 mm for diagonal braces)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i. e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium window, ventilator shutters etc. with EPDM / Neoprene gasket etc complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
Providing and fixing glazing in aluminium door, shutters etc. with PVC/neoprene gasket etc complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on both sides
Providing and fixing Double action hydraulic floor spring of approved brand and manufacture I.S.:6315 marked, Hardwyn Make (Model 3000) or equivalent for doors including cost of cutting floors as required, embedding in floors & cover plates with brass pivot and single piece M.S. sheet outer box with side plate etc.complete as per the direction of E/I. WITH STAINLESS STEEL COVER PLATE:-
Providing and fixing aluminium TOWER BOLTS ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required color or shade with necessary screws etc. complete.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.. (Approved Brand - GODREJ/ DORSET)
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stoppers ISI marked anodized (anodic coating not less than grade Ac 10 as per I.S. 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper
Providing and fixing wooden moulded beading to door frames with iron screws, plugs and priming coat on unexposed surface etc. complete. 50X20 MM
Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of shutters (over all area of door shutter to be measured).
Providing and fixing 100 mm brass Locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing 1mm thick PVC rigid foam sheet over w.c.'s door shutter using synthetic rubber based adhesive (Fevicol SR 998 or equivalent).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
1.0 mm thick
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Supplying, fitting & fixing local made COLLAPSIBLE GATE of approved size and make properly fabricated with vertical double channel 20 x 10 x 2 mm at 100 mm center and braced with M.S. flat diagonals 20 x 3 mm with top and bottom rail of T. iron 40 x 40 x 6 mm with 38 dia steel pulleys complete with bolt, buts locking arrangement, steppers, handles including applying a primer coat of read lead paint carriage, hoisting and taxes etc. all complete as per building specification and direction of Engineer Incharge.
WATER PROOFING TREATMENT
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roof terraces etc. consisting of following operations.
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS : 2645 over the RCC slab including cleaning the surface before treatment.
Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 over 20 mm thick layer of cement mortar 1:5 (1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS: 2645.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand ) admixed with proprietary water proofing compund conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300X300 mm square.
The whole terrace so finished shall be flooded with water for minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the E/I.
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
(WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing tuck pointing [1:3] in cement on brick work clean coarse sand of F.M 1.5 FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Providing 12mm cement plaster(1:3) with clean coarse sand of F.M 1.5 including screening, curing with all leads and lifts of water scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5 mm th. cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roof terraces etc. consisting of following operations.
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS : 2645 over the RCC slab including cleaning the surface before treatment.
Laying cement concrete using broken bricks/brick bats 25 mm to 100 mm size with 50% of cement mortar of mix 1:5 ( 1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 over 20 mm thick layer of cement mortar 1:5 (1 cement : 5 coarse sand ) admixed with proprietary water proofing compund conforming to IS :2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs
After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS: 2645.
Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand ) admixed with proprietary water proofing compund conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300X300 mm square.
The whole terrace so finished shall be flooded with water for minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the E/I.
With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (WORKS TO BE DONE BY REGISTERED APPLICATOR OF PIDILITE/ SIKA/ ROFF WITH 10 YRS. GUARANTEE.)
Providing and mixing Liquid Intergral water proofing compound in Concrete or plaster as per manufacturer specifications and as per direction o Eng- in Charge. Brand - Sika Plastocrate plus MYK proof WP 10, Fosroc -Conplast X4211C, Dr. fixit Pidiproof LW+ or Equivalent.
FINISHING WORKS
Providing applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth copmlete .
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I
Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives "Snowcryl - XT" of M/S Snowcem India Ltd, or equivalent of required shade.
New work (Two or more coats applied @1.43 ltr / 10sqm. Over and including base coat of water proofing cement paint Snowcem Plus or equivalent applied @ 2.20 kg./10 sq.m. )
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
Finishing walls with textured exterior paint of required shade :
13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
Providing two coat of snowcem of approved shade and make over a coat of cement of primer on new surface including preparing the plastered surface smooth with sand paper, soaping, curing and taxes all complete as per building specification and direction of E/I.
Providing two coats of SYNTHETIC ENAMEL PAINT of approved shade and make over new WOODEN surface including cleaning the surface after removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification dirction of E/I.
Providing Primer one coat of read lead paint of approved make over new STEEL SURFACE preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
MISCELLANEOUS WORK
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners, etc.)
Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Coupler - 110 mm
SHOE - 110MM
BEND 110MM
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised @80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (Approved brand - Armstrong/ Knauf/ Anutone)
With 20 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.7), (Approved Brand - Armstrong)
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recomme-nded jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.45.1 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I Approved Brand - Knauf/ St Gobain/ Equivalent
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Approved Brand - Tata Bluescope/ Equivalent)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Gutter .(600 mm over all girth), BOTH SIDE
Making Soak Pit 2.5 m diameter 3.0 meter deep with 45x45cm dry briick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standerd design .
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying and fixing C. I. Cover without frame for MANHOLE. 560MM DIA C.I. COVER (HEAVY DUTY)
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910, on 12 mm dia steel bar confirming to IS: 1786, having minimum cross section as 23 mmX25mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protuded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in tank with 30X20X15 cm cement concrete complete as per design.
DT: Basic rates for 125/115 mm dia Drilled Tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH ring Machine all complete including supplying all meterial, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc. and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of engineer-in-charge. (Basic rates) (i) Drilling up to 30 mtr. Depth below G.L. in Rural Area
Supplying, assembling, lowering and fixing in vertical position in borewell unplasticized PVC medium well screen (RMS) pipes with ribs, confirming to IS: 12818, including hire and labour charges, fittings and accessories etc. all complete, for all depths, as per direction of engineer-in-charge. (100 mm nominal size dia. )
Supplying,filling, spreading and levelling stone boulders of of size range 5cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Supplying,filling, spreading and levelling gravels of size range, 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in the required thickness, for all leads and lifts, all complete as per direction of E/I.
Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Inside dimensions 455X610mm and 45 mm deep for single pipe line with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.
150 MM dia R.C.C. pipe
250 MM dia R.C.C. pipe
Supplying fitting and fixing Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm (2'-0"x2'-0"*2) in position as per specification and direction of E/I.
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceablematerial to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost).
CARRAIGE OF MATERIALS
SAND , LEAD - 40 KM.
STONE CHIPS , LEAD - 23 KM.
BRICKS , LEAD- = 8 KM. (1 KM KACHCHA ROAD)
DISPOSAL OF EARTH , LEAD - 5 KM.(1 KM KACHCHA ROAD)
FIRE FIGHTING
Supply, installation, testing and commissioning of Micro Processor based Fire Alarm Control Panel with LCD display having capacity of connecting min 100 devices with suitble number of MCP and Hooters. separate hooter connections to be available for each zones. complete with all accessories.(MAKE: AGNI , LIFE GUARD, QUTAK)
Supply, installation, testing and commissioning of Optical smoke detector complete with base.(MAKE: SYSTEM SENSER, APPOLO, QUTAK)
Supply, installation, testing and commissioning of manual call point complete with mounting base.(MAKE: AGNI , LIFE GUARD, QUTAK)
Supply, installation, testing and commissioning of Hooter. (MAKE: AGNI , LIFE GUARD, QUTAK)
Supply and laying of 1. 5 sq. Mm double core copper wire in existing PVC Conduit.(MAKE: POLYCAB, MESCAB)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Size 25 mm
Providing and Fixing M. S. pipe as per 1S1239 ( Heavy Class ) complete with all fittings like unions, couplings, bends, elbows, tees, offsets, reducers, flanges, etc. As per requirement at site including painting with two coats of synthetic enamel paint, cutting and making good the walls complete. Pipe upto 50 mm dia. will be with threaded joints with hold tight and 65 mm dia. And above will be with welded joint. The cost shall include the MS / Gl structural supports as per approved drawings and specifications.(MAKE: TATA, JINDAL, NEZONE)
100 mm dia.
80 mm dia.
65 mm dia.
25 mm dia.
SITC of conventional Sprinkler Quartzoid bulb type with 15 mm screwed end connection of 68 degree Centigrade temperature rating K 80 and orifice shall not be less than 6 mm. Sprinkler shall be UL listed/FM approved with Chrome finished. (MAKE: HD, TYCO)
Providing and fixing ISI marked SS-304 fire hydrant valve 80 mm inlet with single outlet and fitted with 63 mm dia instantaneous female coupling on the outlet complete including companion flanges, pvc black cap and chain, nuts,bolts and 3 mm thick compressed asbestos gasket at locations as per drawings ( inlet flange as per IS : 5290-1969 Class C )(MAKE: LIFE GURD, NEW AGE, ATASEE)
Providing and fixing first aid fire hose reel drum wall mounting & swinging type fitted with 20 mm dia 36. 5 m long high pressure hose as per IS : 5132 with 5 mm outlet SS nozzle with shut off valve ( IS : 884-1969).(MAKE: LIFE GURD, NEW AGE, ATASEE)
Providing and fixing 63 mm dia 15 m long EPDM lined fabric hose including SS male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to IS 636 Type II and coupling to IS : 903-1975 with ISI(MAKE: LIFE GURD, NEW AGE, ATASEE)
Providing and fixing standard short size SS branch pipe with nozzle 16 mm dia. Outlet with standard instantaneous type 63 mm dia. Coupling ( ISI lmarked).(MAKE: LIFE GURD, NEW AGE, ATASEE)
Providing and fixing cast iron butterfly valves of PN 1. 6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanges and complete in all respects. mm dia with lever operated. (MAKE: CNR, NVR, SANT, AUDCO)
100 mm dia. With lever operated
80 mm dia.
65 mm dia.
Providing and fixing C. I.horizontal dual plate wafer type non return valves PN 1. 6 including washer, nuts, bolts, 3mm thick compressed asbestos gasket with companion flang, es, complete in all respect. (MAKE: CNR, NVR, SANT, AUDCO)
100 mm dia.
80 mm dia.
65 mm dia.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : ( To be connected to riser ).(MAKE: LIFE GUARD, NEW AGE, ATASEE)
3 way - 150 mm dia M.S. Pipe
Providing and fixing horizontal split casing single/multi stage, single/multi outlet pumping set with bronze impeller with C. I. body and connected by a flexible coupling to a totally enclosed fan cooled induction motor mounted on a common structural base plates with all pump accessories complete as per specifi cations including pressure gauges with gunmetal isolation valves and anti vibration pads, motor to be suitable for 415 volts, 3 phase, 50 cycles A. C. supply (Specifications as per fire fighting requirements and on the pattern of TAC or local authority approval) as per instruction and following specifications LH)ldrant Pump(MAKE: KIRLOSKER, KSB)
Hydrant/Sprinkler Pump
Type : Split casing
Speed (rpm) : 2900
Capacty : 900
MV cable laying upto 25sq.mm in ground:- . Laying of one number PVC insulated and PVC sheathead/ XPLE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Supply of PVC sheathed following conductor 1.1 KV grade armoured Cable of following sizes
4× 16 sq.mm.(aluminium)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required along with existing surface/recessed conduit/submain wiring.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 X 16 sq. mm (28mm)
SANITARY
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast iron P or S trap, 10 litre low level white P.V.C. Flushing cistern with munally controlled device (handle lever) conforming to IS:7231 Parryware/ Hindware with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
White Vitreous China Orissa pattern W C pan of size 580 X 440 mm with integral type foot rest.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled devicde (handle lever), conforming to IS:7231, parryware/Hindware/with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.
W.C. pan with ISI marked white solid plastic seat and lid.
Providing and fixing C.P. brass bib cock of approved conforming to IS 8931
15mm nominal bore approved brand C.P. fittings
Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 810gms.
15mm nominal bore approved brand C.P. fittings
Providing and fixing C.P Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms
Providing and fixing C.P. brass angle valve for basin mixer, gyser & others points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Angle back wash basin (COUNTER TOP) size 400 x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end )
32MM nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.
20mm nominal bore
25mm nominal bore
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT grating of approved quality and colour.
18.58.2 Rectangular type with openable circular lid 18.58.2.1 150 mm nominal size square 100 mm diameter of the inner hinged round grating
Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required:
17.10.2 kitchen sink without drain board
17.10.2.1. - 610x510mm bowel depth 200mm
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
18.50.1 15 mm nominal bore
Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible Pipe
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (ITEM FOR RAIN WATER, SOIL, WASTE & VENT PIPES)
110 mm dia
Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion .
Coupler - (110MM)
Single pushfit Coupler (110 MM)
Single tee with door (110X110X110 MM)
Single tee without door (110X110X110 MM)
Bend 87.5° (110 MM)
SHOE (110 MM)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME)
Concealed work including cutting chases and making good the wall etc..
15mm dia
20mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME)
Exposed on Wall
25mm dia
32 mm dia.
Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testing of joints etc. complete.
150 MM dia R.C.C. pipe
250 MM dia R.C.C. pipe
Constructing brick masonary chamber for Underground C. I. Inspection Chamber and bend with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. Cover with frame (light duty) 455X610 mm internal dimensions, total weight of cover with frame to be not less than 38 KG. (weight of cover 23 kg. and weight of frame 15 kg) RCC top slab with 1:1.5:3 mix (1 cement:1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 mix (1 cement:5 coarse sand :10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm th. with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
Inside dimensions 455X610X mm and 45 mm deep for single pipe with F.P.S. bricks
Providing and fixing C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer.
ELECTRICAL
Point wiring in pvc conduit , with modular type switch:- Wiring for light point/ fan point/exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular switch ,modular plate, suitable GI box etc. as required.
Twin control point wiring in pvc conduit with modular type switch:- Wiring for Twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with 2way modular switch ,modular plate, suitable GI box etc. as required.
Power plug wiring in pvc conduit (4x4 sq mm):- Wiring for light/power plug with 2x 4 sq.mm FR PVC insulated, copper conductor ,single core cable in and surface/recessed PVC conduitalong with 1 No. 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as requried .
Circuit / sub main wiring in pvc conduit:-Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor , single core cable in surface/ recessed PVC coduit as required.
2X1.5 sq mm +1 x 1.5sq mm earth wire.
2X2.5 sq mm +1 x 2.5sq mm earth wire .
2X6 sq mm +1 x 6sq mm earth wire .
4X10 sq mm + 2X10 sq mm earth wire.
Supplying and fixing S.P. MCB DB :- Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board,240 volts,on surface /recess, complete with tinned copper bushbar, neutral link, earth bar, din bar, interconnections powder painted including earthing etc. as required. (but without MCB/RCCB/Isolator)
6way Single door.
Supplying and fixing T.P MCB DB :- Supplying and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts,on surface /recess, complete with tinned copper bushbar, neutral link, earth bar, din bar, detachable gland plate, interconnections,powder painted including earthing etc. as required. (but without MCB / RCCB /Isolator)
4way (4+12), double door,Horizontal type
Supplying and fixing 5 amps to 32 amps, rating, 240 volts, 'C' series, maniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required .
Single pole
16A Single pole & nutral(SPN)
50/ 63 A Triple pole and neutral
Supplying and fixing light plug point with modular type accessories :-Supplying and fixing suitable size GI box with moduler plate cover in the front on surface or in recess including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps. moduler type switch, connections painting etc. as required. (For light plugs).
Supplying and fixing power plug point with modular type accessories :- Supplying and fixing suitable size GI box with moduler plate cover in the front on surface or in recess including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps. moduler type switch, connections painting etc. as required. (For power plugs).
Supplying and fixing Batten holder:-S/F of batten/angle holder including connection etc as required.
Installing, Testing and Commissioning of exhaust fan upto 450 mm sweep :- Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
Supplying and fixing ceiling rose :- Supplying and fixing 2 pin 5A ceiling rose on the existing junction box wooden block including connection etc ,as required.
Supplying and fixing modular type switch / socket :- Supplying and fixing following moduler switch / socket on the existing moduler plate & switch box including connection but excluding moduler plate etc. as reqd.
5/6 amps one way switch
5/6 amps socket outlet
Supplying and fixing modular type electronic fan regulator :- Supplying and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connection but exluding modular plateetc.as required..
Supplying and fixing modular type blanking plate.:- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying, Installing, Testing and Commissioning of following rating surfface mounted LED tube light fitting suitabe for 230v 50Hz single phase supply etc complete as required
20/22w LED tube light
Supplying, Installing, Testing and Commissioning of following rating recess/ surfface mounted LED round /square shape down light luminaierewith pressure die cast housing for single phase supply voltage luminarie shall be confirm to IS:10322 part-5/section 2 or IEC :62722 with all necessary accessories as required.
18/20w LED round down light.
Supplying, Installing, Testing and Commissioning of following size ceiling fan 3 blades confirming to IS-374:2019including wiring the down rods of standared length (upto 30 cm)with 1.5 sq mm FR PVC insulated copper wire suitable for 230v 50Hz single phase supply etc.as required.
1200mm (48")Ceiling fan
Providing of 12" (300) mm )metal exaust fan
Supplying and fixing of Earthing electrode 80mm dia x 3mtr with backfill compound chemical 4 bag (per bag 25Kg)including earth cutting removing and installation charge.
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess fo connection etc.as required.
Providing and fixing G.I. lightning conductor finial :- P/F of lighting conductor finial, made of 25mm. Dia. 300mm. Long GI tube, having single prong at top, with 85mm. Dia. 3mm. Thick copper base plate including holes etc. complete as required.
Rivetting, sweating and soldering lightning conductor tape :- Rivetting, sweating and soldering of copper/GI tape (with another copper/GI tape base of the finial or any other metallic object) as required.
Providing and fixing G.I. lightning conductor tape in horizontal run :- Providing and fixing GI tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for horizontal run)
Providing and fixing G.I. lightning conductor tape in vertical run :- Providing and fixing GI tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for vertical run)
Providing and fixing testing joint for G.I lightning conductor :- Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc. complete as required.
Supplying and fixing HRC fuse type TP&N switch disconnector:- Providing and fixing of following capacity HRC fuse type TP&N switch disconnector unit in existing metal board ,with ISI marked HRC fuses,including drilling holes in metal board ,making connections,as required.
100A TP&N HRC
63A TP&N HRC(for lift)
Supplying and fixing rewireable double pole / TP&N switch disconnector:- Providing and fixing of following capacity DP/ TP&N sheet metal switch disconnector fuse unit in existing metal board ,with rewireable type fuses,including drilling holes in metal board ,making connections,as required.
16A Double pole(rewireable type)
Supplying and fixing Busbar chamber :- Providing and fixing following capacity Busbar chamber with 4 strips of suitable size made of copper, heavy duty,complete with all accessories including connections,earthing the body etc as required.(for lift room)
Supply of PVC/ XLPE Insulated PVC sheathed heavy duty armoured electric cable with alluminium conductor for working voltage upto and including 1100 volts (conforms to IS:1554,part-1)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size exceeding35 sq mm but not exceeding95 sq mm Direct in ground including excavation ,sand cushioning protective covering and refilling the trench etc as required.
Supplying and making end termination with brass compression
gland and aluminium lugs for following size of PVC insulated
and PVC sheathed / XLPE aluminium conductor cable of 1.1
kV grade as required
3½ X 50 sq. mm (35 mm)
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:
a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI?212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm
Providing and fixing CO2 extinguisher consisting of seamless MS cylindrical body squeeze lever discharge valve, internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle ISI marked as per IS 13869 including fixing with dash fasteners etc. complete. (MAKE: LIFE GUARD/ SAFEX/ ATASEE)
Capacity 4.5 kg.
Providing and fixing stored pressure Multipurpose fire extinguisher consisting of welded M.S. cylindrical body, squeeze lever discharge valve, 30 cms long high pressure discharge hose ISI marked as per IS:15683 including fixing to wall with brackets etc. complete.(MAKE: ROYAL GUARD/ EQUIVALENT.
Capacity 6 Kg.
Providing and fixing 25 mm dia brass ball valve full bore type with lever and screwed female ends.(20kg./sq.cm) (MAKE - ZOLOTO/ EQUIVALENT)
providing and fixing fire hose cabinet fabricated from 16 gauge M. S. sheet with single glazed front door and pad locking arrangement, painted Fire Red with stove enameled paint and FIRE HOSE written on front including necessary supports (to house ONE length of canvas hose with couplings, branch pipe and nozzle). (Make - Scott/ Atasee/ Lifeguard.)
Providing and fixing 25 mm dia gun metal single acting air release valve with screwed inlet tested for 20 kg. / cm2. (MAKE - SCUD/ NVR / LP)
Providing and fixing dial type pressure gauge with isolation cock and chrome coated copper pipe on main header Dial dia. 150 mm calibration 0-15 kg. /cm2. (Make - AAVAD/ EQUIVALENT)
Providing, designing and fixing of panel for fire pump. (Make - GUJRAT/ EQUIVALENT)
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Supplying fitting and fixing HCI fittings of approved make confirming to I.S.I. 1729 including suppying nails and bobbines lead and yarn from making lead caulked joints including earthwork or providing scaffolding as the case may be all complete as per specification and direction of E/I.
floor trap without grating (cost of grating is deducted (rate from sl no. 137))
100 mm dia.
Providing and fixing C.P. brass Auto press Pillar Tap in hand wash including all fittings complete job. PILLAR TAP - PRS - 031 (Make - Jaquar/ Kohler/ Grohe)
Add 18% GST
Add 1% Labour cess 1%
M/s Vinod Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .