| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | ₹11.9 L Quoted ₹12.2 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹12.7 L+₹57,024 (4.69%)Rejected-Finance | ₹12.7 L+₹57,024 (4.69%) | L2 | Rejected-Finance Being other than L1 bidder |
| 3 | L3₹14.1 L+₹2.0 L (16.3%)Rejected-Finance R O 218 05 OPP J D A COMPLEX TRIKUTA NAGAR JAMMU J K PIN 180020 | JAMMU | JAMMU AND KASHMIR | 180020 | ₹14.1 L+₹2.0 L (16.3%) | L3 | Rejected-Finance Being other than L1 bidder |
| 4 | L4₹15.2 L+₹3.1 L (25.2%)Rejected-Finance MURSTEY COLONY PLOT NO 16 LEH 194101 LADAKH | LEH LADAKH | LADAKH | 194101 | ₹15.2 L+₹3.1 L (25.2%) | L4 | Rejected-Finance Being other than L1 bidder |
| Sl No | Description | Qty | Unit | M/S ZTECH L3 | Ms Salaria Builders L2 | M/S SHAMSHER ALI SUFI L4 | Sona Enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge. | 401 | Point | 50 ₹20,050 | 18 ₹7,218 | 9 ₹3,609 | 5 ₹2,005 Lowest |
| 2.00 | Taking down of submain wiring surface of wall, floores / ceiling and match the existing complete all as specified and directed. | 300 | RM | 50 ₹15,000 | 8 ₹2,400 | 17 ₹5,100 | 5 ₹1,500 Lowest |
| 3.00Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- | |||||||
| 3.01 | One light/exhaust fan point controlled by one one way switch | 218 | Per Point | 950 ₹2,07,100 | 675 ₹1,47,150 Lowest | 900 ₹1,96,200 | 910 ₹1,98,380 |
| 3.02 | One switch socket outlet 6 Amps, 230 volts point on Same board | 20 | Per Point | 500 ₹10,000 | 245 ₹4,900 Lowest | 499 ₹9,980 | 910 ₹18,200 |
| 3.03 | One switch socket outlet 6 Amps, 230 volts point on independent board | 22 | Per Point | 950 ₹20,900 | 675 ₹14,850 Lowest | 950 ₹20,900 | 910 ₹20,020 |
| 4.00 | All as item No 3 above, but using cables 2.5 Sq mm size . | 29 | Per Point | 1,290 ₹37,410 | 810 ₹23,490 Lowest | 1,299 ₹37,671 | 1,080 ₹31,320 |
| 5.00 | All as item No 3 above, but using cables 4 Sq mm size. | 112 | Per Point | 1,850 ₹2,07,200 | 1,250 ₹1,40,000 Lowest | 1,679 ₹1,88,048 | 1,450 ₹1,62,400 |
| 6.00 | Supply and replacement of lamp holder insulated body with back plate. | 35 | Each | 30 ₹1,050 Lowest | 55 ₹1,925 | 75 ₹2,625 | 30 ₹1,050 Lowest |
| 7.00 | Supply and fixing of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed. | 238 | Each | 60 ₹14,280 | 25 ₹5,950 | 34 ₹8,092 | 20 ₹4,760 Lowest |
Tender Value
₹20.7 L
EMD Value
₹41,500
Closing Date
29 May 2026, 6:00 pmClosed
GE 865 EWS
GE 865 EWS PIN-913865 c/o 56 APO
SPL REPAIR OF REWIRING OF MAIN REPAIR BAY BLDG NO P-97 OF 114 FWC (7014 EME BN) UNDER GE 865 EWS LEH
2026_MES_763894_1
865/EWS(NIT-85)/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE 865 EWS
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹41,500
Yes
17 Aug 2026
7 May 2026
6 Jun 2026
7 May 2026
29 May 2026
22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge. | 401 | Point | - | - |
| 2 | Taking down of submain wiring surface of wall, floores / ceiling and match the existing complete all as specified and directed. | 300 | RM | - | - |
| 3Point wiring complete with 1.5Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed solid 1.5Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- | |||||
| 3.01 | One light/exhaust fan point controlled by one one way switch | 218 | Per Point | - | - |
| 3.02 | One switch socket outlet 6 Amps, 230 volts point on Same board | 20 | Per Point | - | - |
| 3.03 | One switch socket outlet 6 Amps, 230 volts point on independent board | 22 | Per Point | - | - |
| 4 | All as item No 3 above, but using cables 2.5 Sq mm size . | 29 | Per Point | - | - |
| 5 | All as item No 3 above, but using cables 4 Sq mm size. | 112 | Per Point | - | - |
| 6 | Supply and replacement of lamp holder insulated body with back plate. | 35 | Each | - | - |
| 7 | Supply and fixing of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed. | 238 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
TENDERNIT85.pdf
Tender Documents • 0.84 MB
BOQ_855639.xls
BOQ • 2.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .