Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹52 L
EMD Value
₹52,000
Closing Date
30 Jul 2020, 3:00 pmClosed
Project Director
DRDA, VPM
To Provide Functional Household Tap connection to Rural Households in 1 Village Panchayats in Merkanam Panchayat Union in Viluppuram District for 2020-21 Package TNVPM/JJM 20-21/087
2020_RDTN_172301_1
TNVPM/JJM-2020-21/087
Open Tender
Civil Works
Works
180 days
Viluppuram District
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹52,000
Yes
31 Jul 2020
21 Jul 2020
30 Jul 2020
21 Jul 2020
30 Jul 2020
21 Jul 2020
Amount
Providing a distribution pipeline 570 m & FHTCs @ Salai Colony
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63 mm OD PVC Pipe 4 KSC
Supply,delivery, laying and jointing of 63mm OD PVC 4Ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by TWAD Board Officer.
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63mm PVC Bend page 12 ,sl.no-3
63mm PVC Tee IS
63mm End cap page 12 sl.no 11
Laying and jointing of GI Pipes with GI specials and PVC specials etc
C.C. Roads
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Dirt Box and provision for Specials
Provision for pit for Water meter 90X75cm
Provision for gate valve 80 mm
Provision for pit for Water meter 90X75cm
Provision for Jungle clearance
Providing for FHTC (8 meter length per FHTC)
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Provision for Nameboard & Photographic charges
Providing a pumping main 500 m @ New Colony, Construction of New OHT 30000 Lts Distribution Line 1300 m & FHTCs @ New Colony.
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 90 mm OD PVC Pipe 6 KSC
Conveying the PVC Pipes and specials to trench lowering into the trenches, laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste and testing to the required pressure as per IS including conveyance etc
a. 90 mm OD PVC Pipe 6 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 90 mm OD PVC Pipe 6 KSC
Supply,delivery, laying and jointing of 63mm OD PVC 4Ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by TWAD Board Officer.
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63mm PVC Bend page 12 ,sl.no-3
63mm PVC Tee IS 7834/1987 page 10
Supply and delivery of GI pipes medium class as per IS.1239/part I/ 1990 to site of work with ISI Marking
a.80mm GI pipe
b.80mm GI coupling
Laying and jointing of GI Pipes with GI specials and PVC specials etc
C.C. Roads
Providing 20mm SAV along the pumping main alingment 0.3 X 0.45
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63 mm OD PVC Pipe 4 KSC
Supply,delivery, laying and jointing of 63mm OD PVC 4Ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by TWAD Board Officer.
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63mm PVC Bend page 12 ,sl.no-3
63mm End cap page 12 sl.no 11
Laying and jointing of GI Pipes with GI specials and PVC specials etc
C.C. Roads
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Dirt Box and provision for Specials
Provision for pit for Water meter 90X75cm
Provision for gate valve 80 mm
Provision for pit for Water meter 90X75cm
Providing for FHTC (8 meter length per FHTC)
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Provision for Nameboard & Photographic charges
Earth work excavation and depositing on bank with intial lead and lift in all clasuses of soil such as Hard Gravely soil, Gravely soil except Hard Rock requiring Blasting etc complete as per SS20B for narrow foundation
First Depth 0.0 m - 2.0 m below GL
Second Depth from 2 . 0 m - 4 . 0 m below GL
Filling in the foundation with filling M Sand including cost and conveyance to the site and all labour charges for filling as per standard specifications
Cement Concrete 1:4:8 mix using 40mm ISS HBG stone jelly for Foundation and flooring including cost,conveveyance of all materials and labour charges to laid in layers not more than 15cm thick, well rammed etc, complete with standard specification (Using M Sand)
Reinforced Cement concrete 1 : 1.5 : 3 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing, laying and curing etc complete . (Using M Sand)
Below GL from 1.50 m - 4.50 m
Below 1.50m from GL
0.0m to 4.50 m above GL
4.50 m to 7.32 above GL
7.32 M TO 10.98M above GL
10.98 M TO 14.64 M above GL
14.64M TO 18.30M above
Supplying and Erection centering for sides and soffiots including necessaary supports and strutting as directed by the departmental officers. Rate for 10m2 for the following items (RCC floor slab, roff slab, Rectangular / Square, Tee/ Ell beams, Lintels, StairCase Waist Slablanding slab landing beam Canopy etc in all floors with all cross Bracings using mild steel sheets of size 90cm x 60cm and 10BG stiffened withmild steel angles of size 25mmx3mm for boarding laid over country wood joists of size 10cmx6.50cm spaced at about 90cm centre to centre and supported by Casurina props of 10cm to 13cm dia spaced at 75cm centre etc, complete and as directed.
Plain surface
Below GL
From GL - 3.30 m
From 5.30 m to 6.30 m above GL
From 8.30m to 9.30m above GL
From 11.30 m to 12.30 m
Square column
Below & Above GL
From 3.31m to 4.30 M
From 4.31m to 5.30 M
From 5.31m to 6.30 M
From 6.31m to 7.30 M
From 7.31m to 8.30 M
From 8.31m to 9.30 M
From 9.31m to 10.30 M
From 10.31m to 11.30 M
From 11.31m to 11.45 M
Curved surface
Supplying, Fabricatung and placin g in position of RTS or MS rod for all reinforced cement concrete works as per design given including cost of steel and binding wire in all floors etc,complete complying with standard specification
Painting Two Coats with approved Cement Paint over the Plastered surface over one coat of Whie Cement including cost of all materials and labour charges etc complete
Fabrication,Supply,delivery and fixing of Out side MS Lader of 45 cm clear wide made out of 50 mm x 50 mm x 6mm MS Angle for both sides and for steps at 30 cm c / c welded jointed etc., for I staging from GL to FIRST Brace ( weight 4.50 kg/m ) Second and Third stagging upto Floor slab and Fourth Stagging from Floor Slab Roof Top Cover Slab.Supply,Delivery and Fixing of 32 mm GI Pipes medium for Hand Rails from First stage to Fourth Stage. RCC M30 Grade mix for Landing SlabFive Nos at Ground Level - 1 No and above Ground Level - 4 Nos . Supply and fixing of 32 mm Dia GI Pipes for Landing Slab .Supply and fixing of MS Base Plate of 100 mm x 100 mm x 6 mm thick for fixing Anchore fastener bolt for fixing of Hand Rails at Landing Slab and MS Ladder providing Locking arrangements with two coats of approved Enamel Paint over one coat of redoxide paint as per approved Type Design
Providing and fixing of R C C inner acess ladder in R C C 1:1.5:3 USING 20MM hbg stone for OHT including cost of reinforcement , placing grill in position, centering shuttering , mixing concrete curing etc.,
Providing 110mm AC Vent cowl arrangements mosquito proof nylon net as directed by dept officer
Providing Cut stone slab in CM AC Vent cowl arrangements mosquito proof nylon net as directed by dept office
Providing Man hole Cover of size 0.60m x0.60m in Rc c 1:1.5:3 with suitable Reinforcement and 50 x50x6mm MS angle fixed along edges and as directed by dept officer
Painting TWAD Board emblem on the SR with enamel paint as per Board's specification and as directed by TWAD Board officers
Provision for pipe Inlet and Outlet flow
50mm GI Pipe
50mm GI Pipe
50mm GI Elbow
50mm GI Flange set
50mm GI Coupling
90 PVC Threaded coupler
50mm GI Pipe
50mm dia GI Tee
50mm dia GM Gate valve
50mm dia GI Dummy
Refilling the foundation with excavated earth including consolidation as directed by dept officer
Labour charges for GI Pipe connection to the OHT , for inlet, out let ,overflow pipe and scour arrangements including cutting and threading , earth work excavation & refilling
Providing Hand rails over the Roof slab by using 32 mm GI Pipe with 40mm x6mm MS Flate and fixied with 12mm dia fastner bolt 75mm long and as directed by dept officer
Providing a distribution pipeline 510 m & FHTCs @ Mettu Colony
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63 mm OD PVC Pipe 4 KSC
Supply,delivery, laying and jointing of 63mm OD PVC 4Ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by TWAD Board Officer.
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63mm PVC Bend page 12 ,sl.no-3
63mm End cap page 12 sl.no 11
Laying and jointing of GI Pipes with GI specials and PVC specials etc
C.C. Roads
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Dirt Box and provision for Specials
Provision for pit for Water meter 90X75cm
Provision for gate valve 80 mm
Provision for pit for Water meter 90X75cm
Provision for Jungle clearance
Providing for FHTC (8 meter length per FHTC)
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Provision for Nameboard & Photographic charges
Providing a distribution pipeline 350m & FHTCs @ Rajampalayam
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63 mm OD PVC Pipe 4 KSC
Supply,delivery, laying and jointing of 63mm OD PVC 4Ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by TWAD Board Officer.
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63mm PVC Bend page 12 ,sl.no-3
63mm End cap page 12 sl.no 11
Laying and jointing of GI Pipes with GI specials and PVC specials etc
C.C. Roads
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Dirt Box and provision for Specials
Provision for pit for Water meter 90X75cm
Provision for gate valve 80 mm
Provision for pit for Water meter 90X75cm
Providing for FHTC (8 meter length per FHTC)
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Provision for Nameboard & Photographic charges
Providing a distribution pipeline 600 m & FHTCs @ Vellakulam
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63 mm OD PVC Pipe 4 KSC
Supply,delivery, laying and jointing of 63mm OD PVC 4Ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by TWAD Board Officer.
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63mm PVC Bend page 12 ,sl.no-3
63mm PVC Tee IS page 10
63mm End cap page 12 sl.no 11
Laying and jointing of GI Pipes with GI specials and PVC specials etc
C.C. Roads
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Dirt Box and provision for Specials
Provision for pit for Water meter 90X75cm
Provision for gate valve 80 mm
Provision for pit for Water meter 90X75cm
Provision for Jungle clearance
Providing for FHTC (8 meter length per FHTC)
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Provision for Nameboard & Photographic charges
Providing a distribution pipeline 300 m & FHTCs @ Kallumettupaguthi
Earth work excavation in all types of strata for laying of pipes with the standard trench width as per Bd .Circular No. 28/ AE10/ P&D/ 2001/ dt. 01.10.2001 and JCE (P&D)/ Lr.No. LM/ AE10/ P & D/ 2001/ dt.22.11.2001
Supply of unplasticised PVC rigid pipes as per BIS 4985/2000 with ISI Marking to site of works
a. 63 mm OD PVC Pipe 4 KSC
Lowering and laying the PVC Pipes and specials to trench , laying to proper grade and alignment, Jointing with PVC coupler and specials fixing with Solvent cement paste etc
a. 63 mm OD PVC Pipe 4 KSC
Refilling with excavated soil complying with standard specification in layers of 15 cm thick well rammed and consolidated after pipes and specials are laid and tested.
a. 63 mm OD PVC Pipe 4 KSC
Supply,delivery, laying and jointing of 63mm OD PVC 4Ksc pipe inlcuding earth work excavation in all strata soil, refilling and hydraulic testing, adopting standard specification and as directed by TWAD Board Officer.
Supply of PVC specials as per BIS 10124/1988 Part 1 to 13 &BIS 7834/1975 with ISI Marks to site of works
63mm PVC Bend page 12 ,sl.no-3
63mm PVC Tee IS page 10
63mm End cap page 12 sl.no 11
Laying and jointing of GI Pipes with GI specials and PVC specials etc
C.C. Roads
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Dirt Box and provision for Specials
Provision for pit for Water meter 90X75cm
Provision for gate valve 80 mm
Provision for pit for Water meter 90X75cm
Provision for Jungle clearance
Providing for FHTC (8 meter length per FHTC)
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Provision for Nameboard & Photographic charges
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
Anbalagan
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .