| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Bidder Qualified as per technical specification |
| 2 | Accepted-Technical | Accepted-Technical Bidder Qualified as per technical specification |
| 3 | Accepted-Technical | Accepted-Technical Bidder Qualified as per technical specification |
Updated dates
Tender Value
₹46.6 Cr
EMD Value
₹46.6 L
Closing Date
23 Mar 2026, 3:00 pmClosed
SE Construction Circle UP jal Niga (Urban) Jhansi
Office of Superintending Engineer, Construction Circle, Jhansi
NP Gohand Sarila Reorganization Water Supply Scheme
2026_UPJNM_1110893_1
117/F-03/13 date 27-01-2026
Open Tender
Water Supply
Gohand Sarila
Please refer Tender documents.
2 documents required · 2 mandatory
₹23,600
EE CD UPJN (Urban) hamirpur
₹46.6 L
Yes
SE Construction Circle UP jal Niga (Urban) Jhansi
4 May 2026
30 Jan 2026
23 Mar 2026
30 Jan 2026
23 Mar 2026
30 Jan 2026
5 Feb 2026
CIVIL WORKS
WTP works
Survey, Investigation, Soil Testing, Planning, Design and Drawing construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevant latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be Vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of 4.50 MLD WTP on latest technology,350KL RCC CWR, Admin Building with Command Control Room, and fire fighting arrangements, first aid arrangements Cascading Aerator, Inlet chamber, alum dosing, pre-sedimentation Tank/Rapid Mix/Vertical Flow Clarifloculator/Rapid Gravity Filter with Back Wash Arrangement/Proper Sludge Disposal and Backwash water disposal arrangements to nearest drain/low laying area& Appurtenant Works of the above-mentioned capacity, automated through PLC with outputs to SCADA, walkway in between WTP components with railing, Guard Room, Chemical Store House, Gaseous Chlorination Plant, Development of WTP area with adequate plantation, Rainwater harvesting unit. Lean concrete to be used of grade not less than M-15 and other structures in minimum M-30 grade of concrete. Cement and steel should be as per approved by the Engineer/IS code. Collapsible MS steel doors and aluminum windows to be provided including of three-coat whitewashing, internal two coat white cement painting, external painting with apex ultima/equivalent paint, all steelwork must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification with adequate LED lights for the compound, including automation, instrumentation & SCADA, wireless telemetry (voice & data), including Water Testing Kits, Lab Building and essential lab equipment as mentioned in the related Items Including of supply of all materials, labor T&P etc required for proper completion of works as per direction of the Engineer. All works complete as per design and drawing approved by engineer incharge. contractor will have to provide four wheelers, two wheelers, with fuel & driver for supervision of work and computer/laptop with operator as mentioned in tender document. (Note: Only Civil work)
INTAKE WELL WORKS
Survey, Investigation, Soil Testing, Planning, Design and Drawing, construction, commissioning etc. as per design and drawing provided by the contractor all in accordance with the relevent latest I.S. Codes and approved by the Engineer as per conditions of the bid documents. The design and drawings provided by the contractor should be vetted by any IIT Institute or Government Engineering College approved by the Engineer, on contractor's cost. For construction of Intake Well (for Goahand Np & Sarila Np) of minimum internal size of 6.00 M Dia & required Height with required length & 3.5 M width foot bridge , water inlet opening having minimum intake capacity to meetout the raw water required for WTP by different inlet points, construction of stair case, Pump house, Balcony, stair case post column beams etc. Such that to fix required nos. of VT Pump mention in item number 248, Power Control Panels, starters, intrumentation and SCADA & wireless telemetry (Voice & Data), internal and external electrification with adequate LED lightings including Excavation in soil i.e. Kankar mixed morrom/soft/hard rock and lean concrete of minimum grade of M-15 and R.C.C. in grade M-30 or above, in raft/ pile foundation, Intake R.C.C wall with supply of all type of steel bars of approved quality and cement OPC 53/43 grade of any make approved by the Employer as per design and drawings and binding the same including binding materials, diversion arrangement of flow during construction by making bundh across the dam supply gunny bags, sand, their filling suitable size of steel garder, with chain puli arrangement, dismantling and refixing etc. and also supply and fixing of collapsible gate, collapsible door, almunium window as per relevent specifications also including of three coat white washing, internal two coat snowcem painting, external painting with appex ultima or equivalent paint, all steel work must be painted with red oxide paint and two coat of anticorrosive paint etc. and internal and external electrification of intake well, supply and fixing of three-row of 20 mm dia G (Midium) pipe railing with 65X65X6 mm M.S. Angle iron posts. Supply and fixing of aniet opening of required capacity as per requirements including of supply of all materials, labour, T&P etc. required for proper completion of works as per direction of the Engineer. Cost of VT Pumps, panels, SCADA panel board, pipe manifolds etc. are not covered in this item.
Rising Main & By Pass arrangement
Supply of following sizes of DI pipes, class K-9 with rubber gasket, conforming to IS: 8329/2000 (reaffirmed year 2020) or its latest amendments, F.O.R. destination including insurance etc. complete
350 mm dia D.I. Class K-7
250 mm dia D.I. Class K-7
200 mm dia D.I. Class K-7
150 mm dia D.I. Class K-7
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Carting of the following sizes of D.I. Pipes (class K-9) and specials to the site of work, lowering them in to trenches and laying true to alignment and gradient including testing of pipeline (but excluding cost of trenching and cuttling of pipes etc. for making of lengths but including making joints)
350 mm dia D.I. Class K-7
250 mm dia D.I. Class K-7
200 mm dia D.I. Class K-7
150 mm dia D.I. Class K-7
Excavation for pipeline trenches including lift upto 1.5 m and lead upto 50 m and refilling, watering, ramming of excavated, earth in to the trenches and disposal of surplus earth upto 50 m from the center of the trenches
In ordinary soil (loam, clay, sand)
In soil mixed with moorum/ shingle/ kankar/rock
In soft / Medium rock
Supply & fixing of following sizes of C.I. Double flanged sluice valves as per IS 14846: 2000 (Reaffirmed Year: 2020) or its lastest amendment, class - 1 F.O.R. destination including insurance.
350 mm dia
250 mm dia
200 mm dia
150 mm dia
Carting of D/F Sluice valves of following sizes to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete .
350 mm dia
250 mm dia
200 mm dia
150 mm dia
Supply of following size C.I. Air valve , Swing check type NRV as per IS code 780-1960 tested to 10kg/cm2 fixing in pipeline trenches
50 mm Air valve
250mm NRV
200mm NRV
Carting of air valve of 50mm to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete .
50 mm Air valve
250mm NRV
200mm NRV
Supply of all materials, labour, T&P and construction of following chambers as per type design including supply and materials, labour and T&P, testing etc. complete.
Masonry Type
Air Valve chamber
Dismantling of following type of road surfaces for lying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Bituminous Road
CC Road
Reinstatement of following type of road surfaces for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Bituminous Road
Bituminous Road PWD
CC Road
Supply of all materials, labour, and T & P etc. and construct R.C.C. thrust blocks at bends and below valves as required.(R.C.C. work in 1:1.5:3 with mild steel work)
350 mm dia
250 mm dia
200 mm dia
150 mm dia
Provision for Large crossing of nala,raod & culverts including shiftijng of telephone cabel etc.along the alignment of pipe line including supply of C.I Tyton pipe and special and also jointing material their laying and jointing testing etc,complite.(FOR 7.0 M WIDE )
Supply of MS pipe (As per IS:3589 made from steel confirming to IS:2062), with anti corrosive treatment with P.U. coating and Installation of product pipe by Augor boring method including preparing and setting up the plants and equipement, preparing new pipe work material, installation new pipe-work and commissioning system or making the system ready for commissioning by Augor operation including, all related civil and mechanical works like excavation, shoring/strutting, etc. drilling, stringing, reaming, and pulling back the new pip-work on the designed bore path alignment, proper disposal of drilling fluid, and back fill of site after completion all inclusive as per IndSTT:101:2018: Code of prectice of Augor Technique Suiting Indian Conditions.
600mm dia MS Casing pipe (10mm Pipe Wall Thickness) & 200mm to 300mm MS water main pipe( 8mm Pipe Wall Thickness)
Site clearance
Distribution System
Supply of the following D.I. pipes (K-7) conforming to 1.8 -8329/2000 (reaffirmed year 2020) or its latest amendment(s). Including F.O.R. destinations rate per metre in Rs., anywhere in U.P. including cost of one Rubber Gasket per pipe length & inclusive of Third Party Inspection Charges, Packing & Forwarding Charges, Transit Insurance Charges, Road Transportation Charges etc.
300 mm dia D.I. Class K-7
250 mm dia D.I. Class K-7
200 mm dia D.I. Class K-7
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Supply of the following HDPE Pipes as per I.S. 4984/2016 or its latest amendment inclusive of 3rd party inspection charges, packing and forwarding charges, trasnit insurance charges, road transportation charges etc. F.O.R. destination etc. complete.
HDPE Pipe PN 6: class PE 100
90 mm dia
110 mm dia
140 mm dia
160 mm dia
Supply of Specials for above pipe F.O.R destination including all Taxes and insurance.
Excavation for pipe line trenches in Ordinary soil,(lime, clay or sand Including lift up to 1.5m and lead up To 50m and refilling, watering, Ramming of excavated earth in to trenches and disposal of surplus earth up to 50 m from the center of the foundation trenches.
In ordinary soil (loam, clay, sand)
In soil mixed with moorum/ shingle/ kankar
In soft / Medium rock
Carting of following pipes, specials and fittings to site of work, lowering them into trenches, laying true to alignment and gradient, laying and jointing of pipe line including cutting of pipe for making up lengths as required for proper completion of work. HDPE pipes shall be joined by electrfusion welding fittings and welding equipement, ensuring proper surface preparation,alignment and cooling time.
HDPE Pipe PN 6: class PE 100
90 mm dia
110 mm dia
140 mm dia
160 mm dia
DI Pipe K-7
200 mm dia
250 mm dia
300 mm dia
Supply & fixing of following sizes of C.I. Double flanged sluice valves/Scour valve/Air valve/Fire Hydrant as per IS 14846: 2000 (Reaffirmed Year: 2020) or its lastest amendment, class - 1 F.O.R. destination including insurance.
Sluice Valves
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Scour Valves
100 mm dia
Air Valves
Fire Hydrants
80 mm dia
Carting of valves of following sizes to the site of works lowering them into already prepared trenches and fixing them In position including supply of jointing materials such as bolt nut, rubber insertion white lead complete with excluding values and specials required but including the testing etc. complete .
Sluice Valves
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
300 mm dia
Scour Valves
100 mm dia
Air Valves
25 mm dia
Fire Hydrants
80 mm dia
Supply construction of following chambers as per type design including supply and materials labour, T&P etc. complete.
Surface Box Type
Masonry Type
Air Valves Chamber
Fire Hydrants Chamber
Dismantling of following type of surface including sorting out and staking of serviceable materials and disposal of unserviceable material up to a distance of 50m.
Bituminous Road
CC Road
Inter locking Road
Reinstatment of following type of road including supply of all material, labour etc complete. All works complete as per design and drawing approved by engineer incharge
Bituminous Road
Bituminous Road Pwd
CC Road
Inter locking Road
Provision for Small crossing of nala,raod & culverts including all material labour etc complete.(FOR 0.5m to 1.5 m WIDE )
Provision for Medium crossing of nala,raod & culverts including all material labour etc complete.(FOR 1.5m to 3.00 m WIDE )
Provision for Large crossing of nala,raod & culverts including all material labour etc complete.(FOR Above 3.00 m )
Shiftijng of telephone cabel etc.along the alignment of pipe line including supply of C.I Tyton pipe and special and also jointing material their laying and jointing testing etc,complete.
Supply of all materials, labour, and T & P etc. and construct R.C.C. thrust blocks at bends and below valves as required.(R.C.C. work in 1:1.5:3 with mild steel work)
80 mm dia
100 mm dia
125 mm dia
150 mm dia
200 mm dia
250 mm dia
Site clearance
House connection on New Pipeline
Provision of House connection including Supply of all materials, labours T&P etc required for proper completion of work. (as following)
Making House Connection with distribution main including dismantling of road, supply, carting of specials, Lowering them into trances, fixing them in proper alignment and jointing including bailing out to water, necessary excavation for connection including all labour, T&P etc. required for proper completion of the work. All works complete as per design and drawing approved by engineer incharge
In C. C. Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm dia
For 250 mm dia
In Bituminous Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm dia
For 250 mm dia
In Interlocking Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm dia
For 250 mm dia
Converting existing house connections to new distribution pipelines of various sizes, including supply and carting of specials, trenching, pipe laying and jointing (using existing serviceable and new materials such as 20mm HDPE, 20mm GI, saddles, couplers, elbows, bib cocks, etc.), alignment, dewatering, excavation, barricading, road dismantling and road reinstatement. Includes all labor, T&P, materials, and incidentals for completion in all road types.
In BOE Road
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm dia
In C. C. Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm dia
In Bituminous Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm dia
In Interlocking Roads
For 90 mm to 110 mm dia
For 140 mm to 160 mm dia
For 200 mm dia
RCC OHT
Supply of all materials labour T&P etc. for complete construction of R.C.C. (M30 Grade) Over Head Tank of following capatity and staging min 0.6m above ground level with main components, soil testing and assuming bearing capacity of soil as 8MT including cost of supply of design and drawings. all the water retaining components of OHT shall be casted in M-30 grade cement concrete and minimum grade of concrete of foundation and staging should be M-25 with approved cement, coarse sand and stone grit as per I.S. 11682 and I.S. 456 seismic effects and wind load should be taken into consideration as per I.S. 1893 for earthquake resistance and I.S. 875 Part-III for wind load on structure and including 1M wide RCC doglegged staircase with separate columns, 1m wide R.C.C. M30 balcony, M.S. ladder made of 50x50x6mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium class G.I. pipes, one aluminum ladder inside the tank from top dome to bottom dome, R.C.C. railling with 20mm dia medium class G.I.pipe (in 3 rows) on both sides of stair case, supported on 50x50x6mm M.S. angle section, spaced at intervals not more than 1.5m, proper ventilator at top dome in circular shape of 1.5m dia, Ultra Sonic Water Level Indicator fabricated with sensor connecting to automation, lightening conductor as per I.S.S. 2309 or its latest amendments of latest electricity rules, consisting of proper elecation rod with 5 or more fork points as prescribed in ISS 2309-1969 and ISS 3013-1966 C.I. manhole of min 60x60cm size with locking arrangement, supply, fixing, jointing of D.I.D/F Pipes of appropriate size with D.I.D/F specials conforming to IS 8329/2000 as vertical pipes for all required no of inlet (200mm OR as designed), all required no of outlet (250mm or as designed for each DMA), overflow and washout as per latest/relevant I.S. specification with all jointing materials for proper completion of work along with Sluice valves with actuator,s construction of bed blocks in 1:2:4 PCC with cement, coarse sand and approved stone grit, construction of washout/ overflow chamber and chambers for sluice / butter fly valves as per departmental type design and drawings, supply of 200mm dia PVC pipe as per I.S.-4985/2000 for disposal of water from overflow and washout chamber to suitable point outside the water works compound, Painting of all concrete surface with three coats of approved cement paint, three coats of approved apex ultima paints and steel pipe worrks with three coats of anticorrosive paints.Testing & Commission etc. all complete work.
Zone-1 Gohand
400 KL with 16 m Staging
Zone-3 Sarila
600 KL with 16 m Staging
Zone-4 Sarila
500 KL with 12 m Staging
Testing of bearing capacity of soil from a reorganized Govt. Engineering College or as directed by department.
RCC CWR
Supply of all materials, labour, T&P etc. and construct an RCC CWR of following capacity with RCC structures G.I. Pipe and angle iron posts around the top of sump. M.S. ladder inside the tank, supply and fixing M.H. cover with locking device, ventilator, lightening conductor, water level indicator, fixing of puddle collars and bell mouths, supply and fixing M.S. clamps with RCC coloumn, 25 mm thick PCC 1:2:4 floor over 80 mm PCC 1:4:8 in appron, 150 mm semicircular drain around the sump, escape channel of 20m length and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary CI D/F pipes and valves etc. all complete including testing of bearing capacity of soil and site clearance and other unforeseen items for following zones/sub zones.
CCWR at Zone 1 Goahand
CWR at Zone 3 Sarila
CONSTRUCTION OF PUMP HOUSE , ELECTRIC POWER SUB STATION AT CWR / INTAKE WORKS
Construction of pump house cum PLC over CWR of 5mts height including supply of all materials, labour, T&P Complete as per departmetal type & design drawing.
For Zone 1 & 3
Construction of electric power sub station room including supply of all materials, labour, T&P Complete as per departmetal type & design drawing.
Room Size (8x5x4)M
STAFF QUARTER
Construction of Staff Quarter including supply of all materials, labour, T&P Complete as per departmetal type & design drawing.
Two room staff quarter at intake works
At Zone 01/ Zone02 single room set
At Zone 03/ Zone04 single room set
CONSTRUCTION OF MASTER CONTROL ROOM AT INTAKE WORKS
Construction of Room including all materials, labour, T&P Complete as per departmetal type & design drawing.
Master Control Room (5x4.5x4 M)
BOUNDARY WALL, GATE SITE DEVELOPMENT & APPROACH ROAD
Provide all materials, labour T&P etc. required for proper completion of work and construct RCC Column Boundary wall as deparmental drawing & design.
At Intake, Zone03, Zone04
Provide all materials, labour T&P etc. required for proper completion of work and construct pillars as per type design and fixing of gate 3.6 m wide gate and 1.2 m wide wicket gate.
3.60 m wide gate & 1.2 m. wide Wicket Gate
Provide all materials, labour T&P etc. required for proper completion of work and construct CC road in water works campous.
At Intake, Zone03, Zone04
Provide all materials, labour T&P etc. required for proper completion of work including levelling, dressing excavation and filling of earth where necessary for develop of water works site including carriage of earth.
At Intake, Zone03, Zone04
Repairing of Existing 250 KL/20M Staging Over Head Tank At Zone 02
Providing and fixing double scaffolding system (cup lock type) on the exterior side of OHT, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site,made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis,M.S. clamps and staircase system in the scaffolding for working platform etc.and maintaining it in a serviceable condition for execution of work of cleaning and or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting withthe building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. (CPWD DSR Valume-2 Item No. 14.72)
For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @ 0.05kg/running metre and while the suface is tacky filled the groove up to surface with crystalline mortar @1.50kg/running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @1.50kg/running metre. (CPWD DSR Valume-2 Item No. 22.25.1)
18 mm cement plaster in two coats under layer 12 mm thickcement plaster 1:5 finished with a top layer 6mm thick cementplaster 1:6. (CPWD DSR Valume-2 Item No. 13.11)
Providing and injecting approved grout (OHT tank body) in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-inCharge (CPWD DSR Valume-2 Item No. 26.35) Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work (CPWD DSR Valume-2 Item No. 26.35.1)
Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work. (CPWD DSR Valume-2 Item No. 26.35.2)
Epoxy injection grout in concrete/RCC work of approved make (CPWD DSR Valume-2 Item No. 26.35.3)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-incharge. (CPWD DSR Valume-2 Item No. 22.23)
For vertical surface one coat @1.40 kg per sqm (CPWD DSR Valume-2 Item No. 22.23.1)
Cone wall
wall inner
column inner
For horizontal surface one coat @1.10 kg per sqm (CPWD DSR Valume-2 Item No. 22.23.2)
Bottom Dom
Repair of M.S. ladder made of 80x80x6 mm angle section and 20mm plain M.S. bars with hand rails of 20mm medium quality G.I. pipes on both sides in two rows from balcony to top dome resting on an RCC plateform (60x60cm and 10cm thick) projecting from top ring beam and one ladder inside the tank body (from manhole in top dome to bottom dome).
Repairing 1m wide RCC balcony around the tank wall.
Repairing of proper railing of 20mm dia medium quality, G.I. pipe (in 3 rows) on both sides of stair case, around the balcony, at each landing from landing with top ringbeam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on RCC posts of 100mm dia or on the posts made of 50x50x6 mm MS angle section, spaced at intervals not more than 1.5m.
Repairing of proper ventilator at top dome in circular shape of 1.2m dia along with an RCC cover of min 1.50m dia and 7.5cm thickness, supported on small R.C.C. pillar of min. 50cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standard quality alongwith expanded metal jali.
Repairing of Water level indicator fabricated with good quality min. 45x45x6mm M.S. angle 6 mm flat and 3 mm thick M.S. sheet. The indicator board scale made of 3 mm thick M.S. plate should have a clear width of min. 25cm painted with good paint. It should also consists of 3mm brass wire rope min. 4 smooth pulleys about 8cm dia with guides, 15cm dia copper ball float which shall be completelywater tight suitable pointer of brass etc.
Repairing of C.I. manhold of min 60x60cm size made of M.S. channel section with adequate cover made of M.S. sheet of min 3 mm thickness hinged with manhole with locking arrangement. This manhole should be fixed top dome at proper place.
Repairing of 200/150 mm sluice valve chamber including necessary T&P labours etc. all complete
Construction of masonary type sluice valve chamber for above sluice valves as per departmental type design and drawing .
Cleaning of OHT including rubbing of internal surface of vertical wall, cone wall, bottom dome etc. and disposal of silt and other unwanted materials (Garbage) out side the campous including making arrangement of scaffolding and for collection of silt and garbage at ground and disposal the same by head lead including necessary T&P labours etc. all complete
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (CPWD DSR Valume-2 Item No. 13.91)
Finishing of all Wall/concrete surface in two coat premium acrylic smooth exterior paint with silicon addive, with one coat of exterior primer over smooth base of white cement. cement based wall putty and steel pipe works with three coats of approved cement paint and apex ultima paints (CPWD DSR Valume-2 Item No. 13.47.1)
Painting of all m.s./ steel pipe works with three coats of approved cement paint and anticorrosive paints.
Supply all materials, labour, tools and plants and provide arrangement for ground water recharge as per cost estimate attached.
At ZONAL WATER WORKS
At ZONAL WATER WORKS- Zone02,Zone04
E/M Works
INTAKE WELL
PUMPING PLANTS:
Supply, installation, testing and commissioning of Vertical Turbine Raw water pump (oil cooled)alongwith all necessary arrangements to lift 1700 LPM discharge at 47 m head complete with 11 m column assembly , 30 HP TEFC motor B class insulation with reversible ratchet, chuck nut and top shaft locking arrangement suitable to operate on 415 volt, 3 Phase 50 HZ AC supply. (Synchronous Speed 1450 RPM)
1700 LPM, 30 HP, 47 m Head, 1450 RPM ( Head discharge & Hp may increase as per site condition )
SITC of 30 Kw or more as per site condition with best engineering manner digital Soft Starter with RS485 port - 400 V class for INTAKE Motors
Supply of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in 02 runs
A) MAIN PIPING- Supply & fitting of DIDF/CIDF 150 mm Main piping required for delivery side, 250 mm common Header upto 1 m outside with 3 Nos 250x150x250 mm size Tee and 1 Nos 250x150x250 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer . complete in all respect as per site conditions . ( size of delivery and common header may increase as per site condition)
Nut , bolt & rubber packing
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii) 250 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 150 mm size( Size may increase as per site condition with best engineering manner)
ii) 250 mm size
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 250 mm
ELECTRICAL ITEMS:
SITC of 50 kvar APFC panel suitable for above LT panel for MCWR load with all necessary metering and protective devices complete in all respect.
Supply laying and commissioning & testing of 3.5 core 70 Sq.mm. Armoured Aluminum Conductor Cable From 02 nos of Transformer to LT panel with lugs etc. in 02 runs
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 160 Amp. Or more as per site condition
SITC of dust and vermin proof LT Pannel with electrically and mechanically interlocked 02 nos. incoming of 160 Amp MCCB for 02 nos transformer and 3Nos. , 80 Amp , 2 Nos 32 amp and 2 nos 63 amp outgoing MCCB Mirco processor based complete suitable to operate on 415±6 % volt , 3 phase , 50 Hz, AC supply with CT'S, PT, AVF meter, PF meter, Relay,voltmeter ammeter, protective device and have sufficient space for soft starters of pumping plant complete in all respect. individual motors in cubical type pannel fabricated in compartmentalised (as per instruction of Engineer Incharge) from CRC sheet of 2 mm thick for frame work,2.5 mm for cover and 3 mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified Radar type Level Transmiter for Intake well.
SITC of CE/UL Certified Surge protector for control panel
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 3Ton capacity upto 6 m span electrically operated travelling Crane (Single Girder)with 6 m lift complete with wire rope hoist,class II all three motions electrically operated by suitable rating motor IP 54 ,control panneland down pendant control block.
Tools
10 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type
Internal & External electrification and lighting (illumination) and ventillation (including bird guard /exhaust fan if required) of pumping station including concealed conduit or duct wiring with any electrical item required for proper completion of work
Lightining of INTAKEWELL campus
Supply ,fixing & commissioning of Ms Tubular poles SP36 9.5 m height with junction box with all labour material and T&P
Supply ,fixing &commissioning of @x40 w LED Green Grace light lumen 120w colour warm white as per required illumination level with all labour materialand T&P
S/f of unarmoud aluminium cable 6sq mm 2 core for connection of above light through junction box
Painting of pumping plant and other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all equipments and pumping plants etc complete in all respect.
E/M work at WTP 4.5 MLD
EPC contract for a 4.5 MLD Water treatment Plant including detailed design and drawings ,SITC of all electromechanical works with latest SCADA based automation ,integration with approbed civil structures ,all labour and T&P ,wetted parts design subjected to Engineer-in -charge approval ,adequates standby units and spares and complete gaseous chlorination system (1W+1S) for pre and post treatment with chlorine analyser ,leak detection and absorption system with full safety tools complete in all respects
CCWR AT WTP
PUMPING PLANTS: CCWR for zone 1 & 2
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along withVHS,TEFC,IE-3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
750 LPM, 10 HP, 29 m Head, 1450 RPM
SITC of 7.5 Kw digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply,laying,& commissioning of 3 core 10 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in single runs with all labour , T&P
A) MAIN PIPING- Supply & fitting of DIDF/CIDF 100 mm Main piping required for delivery side, 150 mm common Header upto 1 m outside with 3 Nos 150x100x150 mm size Tee and 1 Nos 150x100x150 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size ( Rates upto 150 mm apply)
ii) 150 mm size
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size
ii) 150 mm size
SITC OF CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 150 mm for CWR outlet
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
SITC of CE/UL Certified level transmitter for CWR
PUMPING PLANTS: CCWR for zone 3 & 4
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along withVHS,TEFC,IE-3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
900 LPM, 15 HP,32 m Head, 1450 RPM
SITC of 15 Kw digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc. in single runs with all material Labour ,T&P
A) MAIN PIPING- Supply & fitting of DIDF/CIDF 100 mm Main piping required for delivery side, 200 mm common Header upto 1 m outside with 3 Nos 200x100x200 mm size Tee and 1 Nos 200x100x200 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size ( rates upto 150 mm Apply)
ii) 200 mm size
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size
ii) 200 mm size
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 200 mm for CWR outlet
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
Electrical Item
SITC of 50 kvar APFC panel suitable for above LT panel for CWR load with all necessary metering and protective devices complete in all respect.
SITC of 75 kvar APFC panel suitable for above LT panel for WTP load with all necessary metering and protective devices complete in all respect.
Supply and Laying of 3.5 core 150 Sq.mm. Armoured Aluminum Conductor Cable from Transformer to Lt Panel with lugs etc. in 02 runs with all material labour ,T&P
Supply & Laying of 3.5 core 95 Sq.mm. Armoured Aluminum Conductor Cable from LT Panel to WTP Panel with lugs etc. in 02 runs with all labour material & T&P
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
SITC of dust and vermin proof Lt cum MCC Panel electrically & mechanically interlocked consisting of 2 Nos incoming Mirco processor based MCCB of 400 Amp( 02 for transformer ) and 03 nos 32 Amp, 03 Nos. of 63 Amp and 02 nos of 320Amp outgoing Mirco processor based MCCB for 03 nos for pumping plant for Zone 1&2,Zone 3&4 and 02 nos for wtp and 2 nos of 63 Amp and 02 nos 100 amp MCCB microprossor based for Lighting /Spare complete in all respect andits capacity suitable to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays , protective device,etc and have sufficient space for soft starters of pumping plant complete in all respect. . Individual motors in cubical type pannel fabricated in compartmentalised (as per instruction of Engineer Incharge) from CRC sheet of 2 mm thick for frame work,2.5 mm for cover and 3 mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified three phase Surge protector for control panel
SITC of CE/UL Certified Radar type Level Transmiter for CWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 3Ton capacity upto 6 m span electrically operated travelling Crane (Single Girder)with 6 m lift complete with wire rope hoist,class II all three motions electrically operated by suitable rating motor IP 54 ,control panneland down pendant control block.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
PUMPING PLANTS: (for Zone I )
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE -3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
650 LPM, 10 HP, 36 m Head, 1450 RPM
SITC of 7.5 Kw digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply & Laying of 3 core 10 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc with all material labour T&P.
A) MAIN PIPING- Supply and fitting of DIDF/CIDF 100 mm Main piping required for delivery side, 100 mm common Header upto 1 m outside with 2 Nos100x100x100 mm size Tee and 1 Nos 100x100x100 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves ( For both main pipe and common header
i) 100 mm size
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 100 mm for CWR common header
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
PUMPING PLANTS: (For Zone III +IV)
SITC of Vertical/Horizontal centrifigual submersible(Polder type )pumpset with all required arrangements of following duties OR SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
800 LPM, 15 HP, 42 m Head, 1450 RPM
SITC of 15 Kw digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply and laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc with all material labour ,T&P.
A) MAIN PIPING- Supply & fitting of DIDF/CIDF 100 mm Main piping required for delivery side, 150 mm common Header upto 1 m outside with 3 Nos150x100x150 mm size Tee and 1 Nos 150x100x150 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii) 150 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii)150 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 150 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
Electrical Item
SITC of 25 kvar APFC panel suitable for above LT panel for CWR3 load with all necessary metering and protective devices complete in all respect.
Supply and laying of 3.5 core 35 Sq.mm. Armoured Aluminum Conductor Cable from TRANSFORMER TO LT Panel with lugs etc. in 03 runs with all labour material , T&P
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
(i) 100 Amp. Or more as per site condition
SITC of dust and vermin proof Lt cum MCC Panel electrically& mechanically interlocked consisting of 2 Nos incoming Mirco processor based MCCB of 100 Amp( 02 for transformer ) , 02 nos 32 Amp & 02 nos 63 Amp outgoing Mirco processor based MCCB for zone I & II pumping plant, and 02 nos 32 amp and 02 nos 63 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays , protective device, etc and have sufficient space for soft starters of pumping plant complete in all respect. Individual motors in cubical type pannel fabricated in compartmentalised (as per instruction of Engineer Incharge) from CRC sheet of 2 mm thick for frame work,2.5 mm for cover and 3 mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified three phase Surge protector for control panel at main switch
SITC of CE/UL Certified Radar type Level Transmiter for CWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 3Ton capacity upto 6 m span electrically operated travelling Crane (Single Girder)with 6 m lift complete with wire rope hoist,class II all three motions electrically operated by suitable rating motor IP 54 ,control panneland down pendant control block.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
PUMPING PLANTS: (for Zone III )
SITC of Vertical/Horizontal centrifigual submersible(Polder type )pumpset with all required arrangements of following duties OR SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE -3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
950 LPM, 15 HP, 34 m Head, 1450 RPM ( head ,discharge & hp may increase as per site condition)
SITC of 15 Kw or more as per site condition with best engineering mannerdigital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply & laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc with all labour, material ,T&P.
A) MAIN PIPING- Supply and fitting of CIDF/DIDF 100 mm Main piping required for delivery side, 150 mm common Header upto 1 m outside with 3 Nos150x100x150 mm size Tee and 1 Nos 150x100x150 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions ( size of delivery and common header may increase as per site condition).
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii) 150 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii)150 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 150 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
PUMPING PLANTS: (For Zone IV)
SITC of Vertical Turbine water lubricated Clear Water Pump with 5 mt column assembly along with VHS,TEFC,IE3 Electric motor complete with ratchet arragment chucknut and top shaft locking arragment with following specifications.
800 LPM, 15 HP, 41 m Head, 1450 RPM (head ,discharge & hp may increase as per site condition)
SITC of 15 Kw or more as per site condition with best engineering manner digital Soft Starter with RS485 port - 400 V class for CWR Motors
Supply & laying of 3 core 16 Sq.mm. Armoured Copper Conductor Cable from Starter to respective motors with lugs etc with all material labour T &P.
A) MAIN PIPING- Supply & laying of CIDF/DIDF 100 mm Main piping required for delivery side, 150 mm common Header upto 1 m outside with 3 Nos150x100x150 mm size Tee and 1 Nos 150x100x150 mm size Tee for bye pass arrangement of the pump house along with all necessary dismantaling joints, enlarger , reducer nuts, bolts, rubber packing etc. complete in all respect as per site conditions .(size of delivery and common header may increase as per site condition
B) VALVES-
a) SITC of following size motor operated actuaters with DIDF/CIDF sluice valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii) 150 mm size( Size may increase as per site condition with best engineering manner)
b) SITC of following size DIDF/CIDF Non Return Valves
i) 100 mm size( Size may increase as per site condition with best engineering manner)
ii)150 mm size( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Electromagnetic flow meter
(i) Electromagnetic flow meter of size 150 mm for CWR common header( Size may increase as per site condition with best engineering manner)
SITC of CE/UL Certified Pressure Transmitter for each pump and common header
Electrical Item
SITC of 30 kvar APFC panel suitable for above LT panel for CWR2 load with all necessary metering and protective devices complete in all respect.
Supply and laying of 3.5 core 50 Sq.mm. Armoured Aluminum Conductor Cable from TRANSFORMER TO LT Panel with lugs etc. in 02 runs
SITC of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of followint rating:
SITC of dust and vermin proof Lt cum MCC Panel Electrically & mechanically interlocked consisting of 2 Nos incoming Mirco processor based MCCB of 100 Amp( 02 for transformer ) , 04 Nos. outgoing Mirco processor based MCCB of 63 Amp for 02 nos of pumping plant in both zones III & IV, and 02 nos 32 amp and 02 nos 63 amp MCCB microprossor based for Lighting /Spare complete or suitable capacity to operate on 415±10 % volt , 3 phase , 50 Hz, AC supply with power wiring, Ampere meter, Voltmeter ,CT'S, PT, AVF meter, PF meter, Relays , protective device ,etc and have sufficient space for soft starters of pumping plant complete in all respect.. Individual motors in cubical type pannel fabricated in compartmentalised (as per instruction of Engineer Incharge) from CRC sheet of 2 mm thick for frame work,2.5 mm for cover and 3 mm for gland plates with 7 tank process for Powder coating in approved shade
SITC of CE/UL Certified three phase Surge protector for control panel at main switch
SITC of CE/UL Certified Radar type Level Transmiter for CWR
Double Plate Earthing of complete Pumping Station (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
SITC of 3Ton capacity upto 6 m span electrically operated travelling Crane (Single Girder)with 6 m lift complete with wire rope hoist,class II all three motions electrically operated by suitable rating motor IP 54 ,control panneland down pendant control block.
10 mm Thickness Electrical resistance sheet
Tools
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of pumping station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
Painting of pumping plant and all other E/m equipment with all labour & T& P
Installation, Testing and Commissioning of all above equipments and pumping plants etc complete in all respect.
Automation of Intake Well , CCWR , CWR 1,2,3 & 04
For Intake Well
SITC of CE & UL Certified PLC/RTU with redundantCPU & Power supplyin IP 54 enclose suitable to Communicate with GSM based modem unit with redundant CPU & Power supply with annlog & digital parameter & featuers as specified, for each Intakewell to store and transmit data on GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified in tender technical specifications.
SITC of G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification .
SITC of Intelligent energy meters
SITC of Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps.
SITC of CE/ UL Certified 7" HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters.
Cabling
Complete Cabling for Intake well including all power & control cable of all equipments with labour & T&P.
SITC of Security Survelliance IP Camera with recorder
Automation of OHT
SITC of Motor operated actuator with sluice valve on OHT of 200 mm size of Zone I & 2 .
SITC of Electromagnetic Flow meter on OHT of 200 mm size of Zone I & 2 .
SITC of Motor operated actuator with sluice valve on OHT of 300 mm size of Zone 3 &4
SITC of Electromagnetic Flowmeter on OHT of 300 mm size of Zone 3 &4
SITC of CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with GSM based modem unit with CPU & Power supply with analog & digital parameter & features as specified, for each (tubewell/ OHT) stand alone OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations (Payment only for each stand alone OHT OR As per instructions of Engineer Incharge)
SITC of G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/ PLC Capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer anteena made for pumping plant with internet charges ( Payment only for each stand alone OHT OR As per instructions of Engineer Incharge)
SITC of Chlorine Analyzer rnge 0-5 ppm (electrolyte with membrane cap; Type- Amperometric.
SITC of CE/UL certified Radar type Level Transmitter for Over haead Tank for OHT
Master Control Station (MCS)
SCADA DISPLAY
SITC of CE/UL & BIS Certified industrial grade LED MONITOR with latest configrutation as per specification
Desktop/PC with i7 processor for as per specification mentioned in technical bid documents.
SITC of CE/UL Certified 5KVA UPS with batteries as per specification mentioned in technical bid document.
Full development version of required TAGS SCADA Software with coustomisation of software if required for proper functioning of MCS as per requirement of scheme with valid licence /Authorization upto DLP or as per instructions of Engineer incharge
SITC of CE/UL Certified master control room PLC with redundant CPU & power supply at MCS in IP54 - enclouser as spec mentioned in technical bid documents.
SITC of CE/UL Certified Field gateway agent for transfering data from MCS to Central control room.
SITC of GSM based wireless /Broadband/Equipment communication system for PLC capable to transfer & received data & gather dat from remote sites to control station,All accessories included signal enhancer antenna along with running expenses till DLP.
SITC of CE/UL Certified Firewall for network protection.
SITC of SURGE PROTECTOR FOR ETHERNET Communication protection.
SITC of CE/UL certified industrial grade Ethernet Switch.
Mobile App Facility system architecture(Industries internet based & viewed through mobile apps for increased local & Remote Visibility).
Canon/HP or equivalent Laser Printer 1018 or equivement.
SITC of Security Surveillance IP camera with recorder
Installation, Commissioning & testing of all SCADA related equipment including required furniture AC, material labour etc.
Trial run for 3 month period
SUB STATION OF INTAKE (100 KVA)
SITC of 2mm thick MS Sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with suitable size copper bus bar and all accessories and protective devices suitable for 100 KVA 2 Nos.11/0.4 KV transformers.
SITC of 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer. In 02 run
Supply Installation Testing and Commissioning of 100 KVA 11/0.433 KV 50 Hz Copper wound oil cooled Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (copper material)of complete Transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
SUB STATION OF WTP + CCWR 200 KVA)
SITC of 2mm thick MS Sheet fabricated factory wired dust and vermin proof cubical and floor mounting type control panel comprising of 1 No. incoming V.C.B.(630 Amp) and 2 Nos. outgoing V.C.B. panel with suitable size copper bus bar and all accessories and protective devices suitable for 200 KVA OR more as per site requirements , 02 Nos.11/0.4 KV transformers.
Supply and laying of 35 Sq.mm size XLPE cable from 11 K.V.UPPCL metering panel to 11 KV incoming H.T. switch gear panel to transformer.
Supply Installation Testing and Commissioning of 200 KVA OR more as per site requirements ,11/0.433 KV 50 Hz Copper wound oil cooled Transformer with off load tap changer from +7.5% to -15% LV side @ 2.5 % step vectore group Dy11 as per IS 1180, 2014 Part 1 Level 2 effecient with neccessory saefty devices .
Double Plate Earthing (copper material ) of transformer (as per IER/IS) including civil works ,chamber cover and all material, separate double earthing for each equipment shall be carried outas per IER rules
Installation testing and commissioning of 11 KV/0.4 KV substations including Transformers, HT Panels and L.T. main control panel including all labor T&P complete in all respect.
Supply and making indoor/outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs of 35 sq mm size 3 core XLPE aluminium conductor cable of 11 kv grade.
Provision for routine testing of equipments such as transformer, HT Panels and Main LT Panel at manufacturer’s works.
19 mm Thickness Electrical resistance sheet
Supply ,fabrication & fitting Cable trench Chequerred plate 6 mm thickness, angle and C Chanel etc.
S/Fof Fire fighting equipments with proper arrangement with best engineering manner such as four nos. fire extinguishers CO2/ ABC type .
Internal & External electrification and lighting (illumination) of Sub station.with campus lightining as per instruction of engineer incharge .Cost of all electromechanical items and concealed conduit or duct wiring work included in job work
NOC from Electrical safety department for all field installations such as Transformer,pumping plants, substation etc as required for completion of work.
TRAIL & RUN for 03 months Operation Charges for 03 Months of Trial & Run includes 01 supervisor,03 nos operator, 01 electrician 03 nos of SCADA operator each month with gaseous chlorine and PAC for 03 months trail run
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.76 MB
GoSaTDFinal.pdf
Tender Documents • 15.20 MB
BOQ_2051781.xls
BOQ • 0.87 MB
Download all tender documents and submit your bid