| 1 | L1₹2.6 LAccepted-AOC 10 BRIJ VATIKA LAXMIPURA JAIPUR 302 022 RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 302022 | L1 | Accepted-AOC Awarded by Competent Authority |
| Sl No | Description | Qty | Unit | R K ENTERPRISES L1 |
|---|---|---|---|---|
| 1.01 | SH -I
Earthing with G.I. earth pipe 4.5 mtrs long x 40mm dia i/c
accessories and Pdg. masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt) complete as reqd | 2 | Job | 16,500 ₹19,470 Lowest |
| 1.02 | Providing and laying earth connection from earth electrode
with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth
electrode including connection with G.I. thimble excavation and refilling etc as reqd. | 45 | mtr | 13,185 ₹15,558.3 Lowest |
| 1.03 | Providing and fixing 6 SWG dia GI wire on surface
or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring cable etc. as reqd | 60 | mtr | 3,600 ₹4,248 Lowest |
| 1.04 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface recessed steel/PVC conduit /flexible pipe etc as reqd.
(a) 2x6 Sq mm | 120 | Mtr | 30,960 ₹36,532.8 Lowest |
| 1.05 | Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground
including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.
(a) Upto 35 sq. mm | 50 | Mtr | 11,950 ₹14,101 Lowest |
| 1.06 | (b) Above 35 sq. mm and upto 95 sq. mm | 60 | Mtr | 15,540 ₹18,337.2 Lowest |
| 1.07 | SH-II
Supply and fixing of 40 Amp DP MCB in enclosure for providing supply to each energy meter /c connection, testing etc. complete as required. | 25 | Nos | 42,425 ₹50,061.5 Lowest |
| 1.08 | Replacement of 63 Amp 4 pole SDFU (main switch) with HRC fuses in sheet steel enclosure i/c connection, testing etc complete as reqd. (M/S HPL/Havells/S.s make) | 3 | Job | 29,217 ₹34,476.06 Lowest |
| 1.09 | Replacement of following faulty items in existing LT panels etc. i/c connection, testing etc. complete as required.
(a ) 125 Amp TPN SFU (HPL) | 1 | No | 11,098 ₹13,095.64 Lowest |
| 1.10 | (b ) 63 Amp TPN SFU (HPL) | 3 | No | 14,196 ₹16,751.28 Lowest |
Tender Value
₹2.4 L
EMD Value
₹4,764
Closing Date
2 Aug 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical BSNL Gorakhpur
Telephone Exchange Raptinagar Gorakhpur
Replacement of damaged power supply cable and distribution switches ,replacement of damaged cables/wires of various sub meters in Telephone colony Civil lines OA Gorakhpur
2025_BSNL_242189_1
30/TED/GKP/2025-2026
Open Tender
Electrical Works
Item Rate
90 days
Gorakhpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER(Cash)BSNL O/o The GMTD GORAKHPUR
₹4,764
16 Sept 2025
22 Jul 2025
4 Aug 2025
22 Jul 2025
2 Aug 2025
22 Jul 2025
SH -I Earthing with G.I. earth pipe 4.5 mtrs long x 40mm dia i/c accessories and Pdg. masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt) complete as reqd
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and refilling etc as reqd.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring cable etc. as reqd
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface recessed steel/PVC conduit /flexible pipe etc as reqd. (a) 2x6 Sq mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (a) Upto 35 sq. mm
(b) Above 35 sq. mm and upto 95 sq. mm
SH-II Supply and fixing of 40 Amp DP MCB in enclosure for providing supply to each energy meter /c connection, testing etc. complete as required.
Replacement of 63 Amp 4 pole SDFU (main switch) with HRC fuses in sheet steel enclosure i/c connection, testing etc complete as reqd. (M/S HPL/Havells/S.s make)
Replacement of following faulty items in existing LT panels etc. i/c connection, testing etc. complete as required. (a ) 125 Amp TPN SFU (HPL)
(b ) 63 Amp TPN SFU (HPL)
(c ) 125 Amp HRC fuse
(d ) 63 Amp HRC fuse
Supply and fixing of flexible pipe for drawing copper wires etc as reqd.
Dismantling of existing panel, errection of foundation with brick and Cement,sand & reinstallation/fixing of dismantled panel i/c painting , making connection properly etc as reqd.
Repairing of damaged/rusted meter panel with replacement of brocken hinged,providing missing covers/doors, fixing and painting etc complete as reqd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .