Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹49.1 L+₹2.4 L (5.08%)Rejected-Finance NO 3 KEMPANNA ROAD MARUTHI SEVA NAGAR POST BANGALORE 560 033 BANGALORE KARNATAKA | BENGALURU URBAN | KARNATAKA | 560033 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹57.0 L+₹10.2 L (21.8%)Rejected-Finance | L3 | Rejected-Finance Not Lowest |
Tender Value
₹49.3 L
EMD Value
₹98,600
Closing Date
1 Feb 2022, 6:00 pmClosed
GARRISON ENGINEER (SOUTH) BANGALORE
GARRISON ENGINEER (SOUTH) BANGALORE NO 1, ULSOOR ROAD BANGALORE-560 042
AS per BOQ and tender documents
2021_MES_489454_3
GS(S)/B/8564/E8
Open Tender
Civil Works
Item Rate
180 days
Bangalore
AS per tender documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (SOUTH) BANGALORE
₹98,600
Yes
17 Feb 2022
15 Jan 2022
3 Feb 2022
15 Jan 2022
1 Feb 2022
18 Jan 2022
15 Jan 2022 - 17 Jan 2022
Amount
Dismantling of old water proofing treatment including screed bed and cleaning the surface with wire brushes removing dust, foreign material, tree leafs and also cleaned with water pressure and rubbish off the same out side the MD land complete all as specified and as directed.
M&L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 on floor/roof /Chajjas surfaces mixed with WPC @3% by weight of cement finished the surfaces even and smooth without using extra cement all as specified and as directed. (Note:- WPC will be measured and paid seperately under relevent Item of this Schedule)
M&L for 50 mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate), as in roofing as levelling coarse complete all as specified and as directed.
Supply only Integral water proofing compound complete all as specified and as directed.
M&L for cleaning the plastered/concrete surfaces with wire brushes and applying water proofing treatment as under: (a) Apply bitumen primer at the rate of 0.27 litre per Sqm as per IS 3384-1986 and bonding bitumen of VG-10 @1.20 Kg per Sqm. (b) APP modified water proofing memebrane as per IS 16540/16532-2017, 3mm thick and weighing not less than 3.80 kg per Sqm reinforce polyster/HMHDPE matt black finish over compatible primer/bonding bitumen and finish the top surface with bituminus aluminium paint @0.10 Ltr per Sqm complete all as specified and directed.
M&L for forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and as directed.
Dismantling floor hearth/stone slabs/mosaic tile flooring or wall tiling including cement mortar bedding (but not backing) and removing servicebale tiles to stores and rubbish off the same out side MD land complete all as specified and as directed.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) light shade polished, double charged, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
S&F non-skid coloured ceramic tiles joint free 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed of 15mm thick in CM 1:6 etc complete all as specified and as directed.
S&F non-skid coloured ceramic tiles joint free 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a rendering of 10mm thick in CM 1:4 etc complete all as specified and as directed.
Taking down chowkhats or frames exc. 1.5 sq. m but n. exc 4 sqm with shutters (without taking off shutters from the frames) complete all as specified and as directed.
M&L for cutting holes in brick walls built in cement mortar exc half brick wall but n. exc one brick wall for inserting hold fast and securing bolts etc and making good dismantled portion in cement mortar 1 : 3 or cement concrete 1 :2 :4 type B1 as required complete all as specified and as directed.
M&L for forming Jambs, etc to openings (to foregoing items), including cutting, toothing and properly bonding in old work also facing jointing and pointing to match existing work in cement mortar 1:4 complete all as specified and as directed.
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought frame rebated on the solid, rounded or chamfered put together with glue pinned at joints with grooves on both sides for fixing panelled shutter and wire mesh door shutter complete all as specified and as directed.
S&F 40 mm thick flush shutters, solid core construction, with block board core and plywood face panels, both faces are covered with decoretive face veneer with lipping/frame to match complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
S&F aluminium anodised alloy barrel tower bolt 200mm size complete all as specified and as directed.
S&F extruded aluminium alloy handles, fabricated type anodised 150mm size complete all as specified and as directed.
S&F butt hinges medium weight cold rolled mild steel and fixed of size 100mm size complete all as specified and as directed.
S&F 250 mm long mild steel sliding door bolts, plate type, stove enamelled black with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed.
M&L for pre-cast cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in block masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15 mm thick on brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces such as wall finished even and smooth with out using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick on brick work or concrete surfaces on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces. complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of old plastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old distempered surfaces of walls and applying one coat of Oil bound distemper complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood work and joinery n exc 10cm width or girth and applying one coat synthetic enamel paint when unconnected with other painting or when painted in different tint complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood work and joinery exceeding 10cm width or girth and applying one coat synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron work n exc 10cm width or girth and applying one coat synthetic enamel paint when unconnected with other painting or when painted in different tint complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron work exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Dismantling of textile coverings including frames (if any) and cover fillets complete all as specified and as directed.
M&L for providing and fixing gypsum board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and as directed.
Supply only galvanised mild steel plain wire 2.0mm dia in ceiling complete all as specified and as directed.
M&L for applying two coats of oil bound distemper on ceiling board surface over 3mm thick wall care putty complete all as specified and as directed.
Taking down wall panelling and similar work complete all as specified and as directed.
S&F PVC wall panelling 5mm thick both side laminated decorative type complete all as specified and as directed.
M&L for hacking out old broken glass exc.1.5 sqm (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
S&F 12 mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required with Logo of Rasthtriya Military School including complete all as specified and as directed.
M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
M&L for removing carefully and refixing acousting sound proofing wall panel in same place with all precution care required to avoid damage to panel complete all as specified and as directed.
M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and as directed.
Demolition of cement concrete in ground floors & pavings n. exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 25 mm thick cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in floors and pavings complete all as specified and as directed.
S&F non-skid coloured ceramic tiles joint free 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm`, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed of 15mm thick in CM 1:6 etc complete all as specified and as directed.
S&F non-skid coloured ceramic tiles joint free 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a rendering of 10mm thick in CM 1:4 etc complete all as specified and as directed. (Note : The width of tiles 100 mm to be cut from full size of tiles as directed by Engineer-in-charge.)
M&L for false ceiling with GI snap grid frame work of size 595mmx595mm in true horizontal level suspended on interlocking metal grid of hot dipped galvanised steel sections (glavazized @ 170gms/sqm and bottom exposed width prefinished with leaked polyster paint) consisting of main 'T' runners with suitably spaced joints to get required length and of size 38x24x0.3mm spaced at 1200mm centre to centre and cross 'T' of size 24x25x3mm 1200mm long spaced between main 'T' at 600mm center to centre to form a grid of 1200x600mm and secondary cross 'T' of length 600mm and size 24x25x.3mm to be interlocked at middle of the 1200x600mm panel to form grid of 600mmx600mm and wall angle of size 21x21x.3 and laying false ceiling tiles of 4mm thick fiber cement buidling board, non asbestos (minimum weight 4.8kg/sqm) fixed or laid/inserted to GI form work with screws/clips for false ceiling work including, wherever required, cutting/making, opening for services like diffusers, frills, light fittings, fixtures and smoke detectors etc. Main 'T' runners shall be suspended from ceiling using GI slotted cleats of size 25x35x1.6mm fixed to ceiling with 6mm dia and 50m long metal dash fastner, 4mm GI rods with galvanised steel leveling clips spaced at 1200mm centre to centre along main 'T' section (false ceiling system shall be capable to bear distributed load of minimum 15kg/sqm) complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 cum , getting out, returning, filling in and ramming earth or brocken rubble mixed with earth around in layers not exceeding 25 cm , watering and removing surplus soil to a distance not exc 50 M and making good surface in hard/dense soil complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in walls, columns, pillars & posts (including caps & bases) complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe-410- W(Gde- E-250) quality-B complete all as specified and as directed.
S&F MS plates (Plain or chequered) channel, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed.
S&F 0.50 mm thick pre painted galvalume aluminium zinc coating GI based corrugated steel sheet of any. colour on exterior side tensile strength of 550MPA as in roof civering/cladding etc fied with self tapping screws as per manudacturers instructions /'J' type hooks complete all as specified and as directed.
M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting exc. 10 cm but not exc. 20 cm girth complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel and applying two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation surfaces of treating ends of posts, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint complete all as specified and as directed.
M&L for preparation of old decorated/painted surfaces of walls and applying two coat of Oil bound distemper including stopping of nail holes, filling of cracks, etc and cleaning all window panes from splashes / droppings complete all as specified and as directed.
M&L for preparation of old decorated surfaces of walls externally and applying two coat of cement based paint including cleaning all window panes from splashes/dropping complete all as specified and as directed.
M&L for surface excavation n.exc (not exceeding) 30cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified and as directed.
M&L for 75mm thick cement concrete PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base flooring well rammed and levelled all as specified and directed complete all as specified and as directed.
S&F machine pressed rubber finihed coloured precast cement concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement and no pigment laid over and including 50 mm thick consolidated sand cushioning including watering complete all as specified and as directed. Note : The gap between kerb stone & paver block to be filled by cement mortar and finish to match the shade of interlocking paver block as directed.
M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in copings, kneelrs, bed plates, kerbs, water troughs and like including weathering slightly rounded or chamfered in edges including all necessary form work complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing where directed at a level n. exc 1.50m above the starting level complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing unserviceable materials and making good disturbed surfaces of walls, floors etc. complete all as specified and as directed.
M&L for point wiring with PVC insulated, unsheathed, single core multistandard copper conductor cable (FRLS) of size 1.5 Sqmm, 1100 volts grade including 1.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI marked with its acessories & pressed steel terminal boxes and providing 3 mm thick ISI marked laminated sheet cover and brass screws with cup washers for fixing switches / socket / regulators etc for one light/fan point controlled by one switch complete all as specified and as directed.
All as per item No. 68 here-in-before but for one 3 pin 5 Amps socket point on the independent board with other switches complete all as specified and as directed.
All as per item No.68 above but for one 3 pin 5 Amps socket point on the same board with other switches complete all as specified and as directed.
All as per item No.68 above but with 4 Sqmm cable for one 6 pin 15A socket outlet point on independent board complete all as specified and as directed.
S&F switch piano flush type single pole one way 5/6 Amps complete all as specified and as directed.
S&F switch piano flush type single pole two way 15 Amps complete all as specified and as directed.
S&F socket outlet 5 pin 5/6 Amps flush type multipurpose complete all as specified and as directed.
S&F switch piano 15 Amp 230 Volt, flush button single pole one way complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5/6 Amps and 3 pin 15/16 Amps flush type complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type, 230V AC complete all as specified and as directed.
S&F ceiling rose surface bakelite 65x50 mm two to three terminals complete all as specified and as directed.
S&F Modular Switch 1 way 6 Amps 1 Module complete all as specified and as directed.
S&F Modular Socket 6 Amps 2/3 pin combined 2 Module complete all as specified and as directed.
S&F Modular Socket 16 Amps 2/3 pin combined 2 Module complete all as specified and as directed.
S&F metal flush box 3 Module complete all as specified and as directed.
S&F metal flush box 4 Module complete all as specified and as directed.
S&F metal flush box 5 Module complete all as specified and as directed.
S&F metal flush box 6 Module complete all as specified and as directed.
S&F white cover plate with frame 3 Module complete all as specified and as directed.
S&F white cover plate with frame 4 Module complete all as specified and as directed.
S&F white cover plate with frame 5 Module complete all as specified and as directed.
S&F white cover plate with frame 6 Module complete all as specified and as directed.
M&L for sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, 1100 volts grade (FRLS) and one run of 2.5 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows including taking down complete all as specified and as directed. (Note :- Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L for sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi stranded copper conductor cable of size 4 Sqmm, 1100 volts grade (FRLS) and one run of 4 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows including taking downcomplete all as specified and as directed. (Note :- Two runs of 4 Sqmm cable, one run of 4 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M&L for sub main wiring concealed type with two runs of single core, PVC insulated, unsheathed multi stranded copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows including taking down complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
S&F in repair sheet metal enclosure TPN for DB's when MCB's to be used with 200 amps bus bar double door 4 way complete all as specified and as directed.
S&F in repair MCCB 3 Pole 415 V fixed type 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed.
S&F in repair MCB, DB double door type, made out of CRCA mild steel sheet flushed in wall, SPN 4 way with 200 Amps rated bus bar , 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed.
S&F in repair MCB DB double door type for 8 way, 240 Volts 200Amps rated bus bar 240 volts IP-43, with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCB's and isolators etc including complete all as specified and as directed.
S&F in repair MCB TPN 63Amp complete all as specified and as directed.
S&F in repair MCB SPN 63 Amp complete all as specified and as directed.
S&F in repair MCB DP 32Amps complete all as specified and as directed.
S&F in repair MCB SP 5 to 20Amps complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth wire 4.0 mm dia by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 (with 20mm graded stone aggregate),chamber and 50mm thick precast RCC (1:2:4) cover slab re-inforced with XPM Jalli including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion and taking down old one complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium sonductor of size 50 Sqmm x 3.5 core including taking down unserviceable UG cable complete all as specified and directed.
S&F in repair surface mounted Mini Mirror light LED batten 2feet with extruded aluminium housing and robust construction 10 W system lumen with all accessories if required flexible copper 2 core wire from fitting to ceiling rose complete all as specified and as directed. Make:- Bajaj cat part No-BCLSB 10 WH or equivalant in Wipro/Philips.
S&F in repair surface & wall mounted LED batten 4feet with extruded aluminium housing and robust construction 20 W system lumen including flexible copper 2 core wire from tube light fitting to ceiling rose required length with all accessories complete all as specified and as directed. Make:- Bajaj cat part No-BCLSB 20 WH or equivalent in Wipro/Philips
S&F in repair LED surface mounting 2x2 fittings full fit luminarie with glare free uniform illumination with longer life and less maintainance 36 Watt complete all as specified and as directed. Make:- Bajaj cat part No BZRSQL 36W GZiWH or equivalent in Wipro/Philips
S&F in repair LED Square down lighter 32 watt recess mounted round type slim panel down lighter square type with integrated electronic driver of operating voltage 110 to 265 Volts of including connecting up and taking down existing unserviceable ceiling mounted CFL light fitting complete all as specified and as diretcted. Make: Bajaj Cat Part No. BCDLR 32W WH or equivalent in Wipro/Philips
S&F LED Strip light white colour including suitable driver complete all as specified and as diretcted. Make:- Bajaj Cat Part No. NXT 75W PROFESSIONAL LED STRIP IP 65 or equivalent in Wipro/Philips.
S&F LED step light fittings for out door type application multiple colour temp 9 Watt LED warm cool complete all as specified and as diretcted. Make:- Bajaj cat part No. BLSGV 9W LED WW PRO or equivalent in Wipro/Philips.
S&F LED up light fittings for out door type application multiple colour temp 6 Watt LED warm cool complete all as specified and as diretcted. Make:- Bajaj cat part No BLWUP 9W LED WW or equivalent in Wipro/Philips.
S&F wall mounted Air circulator 750mm single phase 230 volt 1440RPM with fixing accessories with suitable wall mounting clamps nut bolt washer etc complete all as specified and as diretcted. Make:- Bajaj Cat part No. 250529 or equivalant in Havells/Usha /Crompton
S&F PVC Body sound proof Exhuast fan 450 mm size with single phase 230 Volt 900 RPM with louvers including dismatling old one deposit to AGE E/M Store yard complete all as specified and as directed. Make:- Bajaj Product code 70102 or equivalant in Havells/Usha /Crompton
S&F ceiling fan 1200mm sweep with down rod of required length and including provision of suitable hook for hanging of ceiling fan, copper conductor cable of size 3 core 0.5 sqmm to PVC terminal of ceiling fan testing including dismatling old one deposit to AGE E/M Store yard complete all as specified and as directed. Make:- Bajaj Cat part No. 250468 or equivalant in Havells/Usha /Crompton
S&F PVC Body sound proof Exhuast fan 250 mm size with single phase 230 Volt 900 RPM with louvers complete.making a hole in wall and after finishing work distrubed surface of wall including dismatling old one deposit to AGE E/M Store yard complete all as specified and as directed. Make:- Bajaj Product code 70049 or equivalant in Havells/Usha /Crompton
S&F in repairs LED security light fittings aesthetically designed roadway luminaire with excellent thermal management complete 45Watt IP 66 including GI Bracket for fixing on wall nut bolt washer etc complete all as specified and as directed. Make :- Bajaj Cat Part No. ENXT P 45L WW CR PC SD or equivalent in Wipro/Philips
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for laying of UG cables and LT Panel board foundation etc and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms in any type of soil complete all as specified and as directed.
Supply and spread river sand to required width at bottom and top for cable cushioning all as specified and directed.(8cm before laying the cable and 15cm after laying the cable and punned into 18 cm thickness) Note: Punned thickness only shall be measured and paid.
Supply and lay burnt bricks of sub class 'B' laid dry across in trenches for cable protection complete all as specified and as directed.
M&L for sub main wiring surface type with two runs of single core, PVC insulated, unsheathed multi stranded copper conductor cable of size 6 Sqmm, 1100 volts grade (FRLS) and one run of 6 Sqmm PVC insulated multi stranded copper conductor for earth continuity conductor drawn through and including suitable size ISI marked rigid PVC conduit with all necessary accessories such as bends, tees, junction boxes, elbows including taking down complete all as specified and as directed. (Note :- Two runs of 6 Sqmm cable, one run of 6 Sqmm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as one length).
M AND V ENTERPRISES
HRML CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .