Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC 2 MANORATH MAIMOLEM VASCO DA GAMA GOA 403802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹26.6 L+₹1.6 L (6.36%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹27.0 L+₹2.0 L (7.94%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹27.9 L+₹2.9 L (11.8%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹29.9 L
EMD Value
₹59,800
Closing Date
1 Apr 2025, 6:00 pmClosed
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2025_MES_700076_1
8602/E8 GE (P) NAVY MANDOVI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Mandovi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (P) Navy Mandovi
₹59,800
Yes
5 Jul 2025
4 Mar 2025
3 Apr 2025
4 Mar 2025
1 Apr 2025
19 Mar 2025
4 Mar 2025 - 18 Mar 2025
Amount
INTERNAL ELECTRIFICATION
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLSH unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including casing and caping of suitable size, with all accessories, with surface mounted PVC box/ concealed metal box with laminated top cover of suitable size as pr site requirement, for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLSH unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for the following complete all as specified and directed. Notes: 1. Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc. 2. Modular cover plate and frame for wiring with modular switches/ sockets shall be measured and paid under relevant item under this schedule.
One light point/fan point/bell point controlled by one switch/ bell push
One 5 amps switch socket combination on indepandent board.
One 5 amps socket outlet on same board controlled by another switch.
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLSH unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including casing and caping of suitable size, with all accessories, with surface mounted PVC box/ concealed metal box with laminated top cover of suitable size as pr site requirement, for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLSH unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one 16 Amp 3 pin / 5 pin switch socket independent outlet, complete all as specified and directed. Notes: 1. Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc. 2. Modular cover plate and frame for wiring with modular switches/ sockets shall be measured and paid under relevant item under this schedule.
M & L for submain wiring with two runs of 6 sqmm single core multistranded FRLSH PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 6 sqmm single core multistranded FRLSH PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/32mm wide FRLSH PVC casing and caping with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire and one run of PVC casing and caping shall be measured as unit run.
M & L for submain wiring with two runs of 4 sqmm single core multistranded FRLSH PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core multistranded FRLSH PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including 25mm/32mm wide PVC casing and caping with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC casing and caping shall be measured as unit run.
S & F in repairs switch piano flush button single pole one way 5/6 Amps for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs socket outlet, flush type, 2 in 1, 3 pin and 5 Amp, white/ ivory for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs switch socket combination 2 in 1, 5 pin and 6 Amps, flush type for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs switch socket combination 3 pin and 16/15 Amps, flush type for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs fan regulator, socket type, deluxe rotary step type, 120 watt, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs call bell, ding dong/ musical/ buzzer, single phase, for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs lamp holder, PVC/ polycarbonate type complete all as specified and directed.
S & F in repairs ceiling rose, surface bakelite PVC/ polycarbonate, isolated body with three terminals complete all as specified and directed.
S & F in repairs LED tube light fitting 20 watt including PVC batten with square profile extruded and polycarbonate frame and connecting with 2/3 core flexible copper conductor cable of suitable size from ceiling rose upto 1.5m length, fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and directed. Make - Bajaj Cat Part No - 830203 or any other equivalent make as specified in List of Manufacturers
S & F in repairs LED tube light fitting 10 watt including PVC batten with square profile extruded and polycarbonate frame and connecting with 2/3 core flexible copper conductor cable of suitable size from ceiling rose upto 1.5m length, fitting duly mounted on PVC block with steel screw & sleeves complete all as specified and directed. Make - Bajaj Cat Part No - 830206 or any other equivalent make as specified in List of Manufacturers
S & F in repairs LED tube light, 18/20 watt and connecting in existing LED fittings complete all as specified and directed. Make - Bajaj Cat Part No - BLRB-20W CW LED (Retro bar) or any other equivalent make as specified in List of Manufacturers
S & F in repairs LED batten tube light, 18/20 watt and connecting in existing LED fittings complete all as specified and directed. Make - Bajaj Cat Part No - RLRB-DB 118 or any other equivalent make as specified in List of Manufacturers
S & F in repairs decorative wall mounting light fittings, opal glass with brushed nickel finish, with acrylic diffuser, alongwith 9 W LED lamp B22, base fittings complete all as specified and directed. Make: Havells Cat Part No. JNL-CHR-WLRB0480SE27 or any other equivalent make as specified in List of Manufacturers
S & F in repairs modular switch 1 way 5/ 6A, 1 module, for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs modular switch, 1 way, 15/16A, 1 module, for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs modular bell push, 1 way, 15/16A, 1 module for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs modular socket, 5/6A, 5 pin, 2 module for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs modular socket, 15/16A, 5 pin 2 module for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs modular cover plate, with frame, 1 module complete all as specified and directed.
S & F in repairs modular cover plate, with frame, 2 module complete all as specified and directed.
S & F in repairs modular cover plate, with frame, 3 module complete all as specified and directed.
S & F in repairs modular cover plate, with frame, 4 module complete all as specified and directed.
S & F in repairs modular cover plate, with frame, 6 module complete all as specified and directed.
S & F in repairs modular cover plate, with frame, 8 module complete all as specified and directed.
S & F power unit up to 25 Amps, for 230 Volts 50 Hz AC supply, fixed on existing 02 module concealed metal box complete all as specified and directed.
M & L for providing 2 module metal box logic, concealed in walls suitable for mounting 2 module power unit complete all as specified and directed.
S & F in repairs concealed/surface fitting MCB DB, double door, having following number of ways, including necessary lugs for incoming and outgoing connections and taking down exisiting DB of any make/ rating at any height, complete all as specified and directed.
MCB DB SPN 4 way
MCB DB SPN 8 way
MCB DB SPN 12 way
MCB DB TPN 4 way
S & F in repairs MCB, 'C' series, of following rating, suitable for 240 Volts 50 Hz AC supply, complete all as specified and directed.
MCB SP 6 to 40 Amp
MCB DP 20 to 40 Amp
MCB TP 25 to 63 Amp
MCB TPN 40 to 100 Amp
S & F in repairs modular fan regulator, step type 100 watt, 2 module, for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs single pole and neutral enclosure with two/ three pin and earth plug and socket complete for snigle pole MCB up to 20 Amp complete all as specified and directed.
S & F in repairs PVC rectangular box for mounting switches, sockets, fan regulators etc, made with 3 mm thick PVC sheet cover, of size 100 mm X 100 mm and 50 mm deep, including provision of cutting on top cover for mounting switches, socket and fan regulators etc as per site requirement complete all as specified and directed.
S & F in repairs PVC rectangular box for mounting switches, sockets, fan regulators etc, made with 3 mm thick PVC sheet cover, of size 175 mm X 100 mm and 50 mm deep, including provision of cutting on top cover for mounting switches, socket and fan regulators etc as per site requirement complete all as specified and directed.
S & F in repairs PVC rectangular box for mounting switches, sockets, fan regulators etc, made with 3 mm thick PVC sheet cover, of size 200 mm X 150 mm and 50 mm deep, including provision of cutting on top cover for mounting switches, socket and fan regulators etc as per site requirement complete all as specified and directed.
S & F in repairs PVC rectangular box for mounting switches, sockets, fan regulators etc, made with 3 mm thick PVC sheet cover, of size 250 mm X 200 mm and 50 mm deep, including provision of cutting on top cover for mounting switches, socket and fan regulators etc as per site requirement complete all as specified and directed.
S & F LED luminaire, 12 watt, for 230 V 50 Hz AC supply, recessed type, round / square, glare free light complete with driver, holders & LED lamp suitable for ceilings including connecting up with driver of suitable size complete all as specified and directed. Make - Bajaj Cat Part No - 830278 or any other equivalent make as specified in List of Manufacturers
REPAIRS TO AIR CONDITIONERS AND COOLING APPLIANCES
Taking down and servicing of split type AC (outdoor and indoor unit), of 1.5/2 TR capacity of any type/ size/ make/ model including cleaning and washing of indoor and outdoor unit assembly with chemical and using high pressure jet pump, checking, re-tightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring, gas charging valve and re-assembling, re-alignment/ refixing indoor and outdoor unit properly after repairs, complete all as specified and directed. Note:- (i) Necessary spares and gas charging shall be measured and paid separately under relevant items of this Schedule. (ii) Record slips of inspection/ job cards alongwith location and user's signature shall be submitted to Engineer-in-charge after completion of each job. Quoted rate shall be deemed to be inclusive of cost of record slips/ Job cards.
Taking down and servicing of defective water cooler of capacity 40/80 or 60/120 Ltr, of any type/ size/ make/ model including cleaning and washing condenser assembly with high pressure jet pump; cleaning, rubbing and washing of storage water tank; draining of dirty water and silt, checking, re-tightening all electrical connections, replacement of nuts, bolts, screws, washers, drain pipes, internal wiring and re-assembling properly after repairs complete all as specified and directed. Note:- (i) Necessary spares and gas charging shall be measured and paid separately under relevant items of this Schedule. (ii) Record slips of inspection/ job cards alongwith location and user's signature shall be submitted to Engineer-in-charge after completion of each job. Quoted rate shall be deemed to be inclusive of cost of record slips/ Job cards.
Taking down and servicing of refrigerators of 165 Ltr to 320 Ltr capacity, of any type/ size/ make/ model including replacement of unserviceable parts, cleaning and washing condenser assembly with high pressure jet pump; re-tightening all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring; fixing properly bracket housing of capacitors and re-assembling properly after repairs complete all as specified and directed. Note:- (i) Necessary spares and gas charging shall be measured and paid separately under relevant items of this Schedule. (ii) Record slips of inspection/ job cards alongwith location and user's signature shall be submitted to Engineer-in-charge after completion of each job. Quoted rate shall be deemed to be inclusive of cost of record slips/ Job cards.
M & L for testing leakage of gas and replacement of damaged portion of copper pipe of any dia upto 30cm length, brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and checking with nitrogen gas flushing to check for leakage in copper pipe lines, recharging suitable gas after complete removal of nitrogen gas on satisfactorily completion of leak test, re-assembling and testing cooling of of following appliances complete all as specified and directed. Note: Refrigerant andd nitrogen gas required shall be measured and paid under relevant item of this schedule.
Refrigerators of any type/ capacity/ make/ model
Water cooler of any of any type/ capacity/ make/ model
Split type AC of any capacity/ make/ type/ model
M & L for submain wiring with two runs of 4 sqmm single core multistranded FRLSH PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core multistranded FRLSH PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including medium duty PVC conduit of suitable size with all accessories such as tees, elbows, junction boxes, reducers etc as required and connecting to existing main switch board/ distribution board and testing on completion including taking down old submain wiring complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
Dismantling and taking down split type AC of capacity 1.5/2 ton from existing location and refixing the same in new location including necessary cutting opening, fixing, connecting, testing and making good disturbed surfaces at both locations complete all as specified and directed. Note : Necessary gas charging, mounting stand, drain pipe and copper tube shall be measured and paid under relevant item of this schedule.
Taking down and dismantling unserviceable blower motor from following appliances of any type including opening outer case, rewinding and heat varnishing the blower motor with super enamel copper wire of suitable gauge by taking out burnt winding and cleaning the iron core complete all as specified and directed.
Window/ split AC of 1.5/2 TR, any type
Water cooler of capacity 40/80 or 60/120 Ltr
S & F in repairs fan motor for indoor unit of split AC 1.5/2.0 TR capacity, single phase 230 Volt, 50 Hz AC supply complete all as specified and directed.
S & F in repairs fan motor for outdoor unit of split AC 1.5/2.0 TR capacity, single phase 230 Volt, 50 Hz AC supply complete all as specified and directed.
S & F in repairs fan motor for water cooler of 40/80 or 60/120 Ltr capacity, single phase 230 Volt, 50 Hz AC supply complete all as specified and directed.
S & F in repairs fan motor for refrigerator of 200 to 310 Ltr capacity, single phase 230 Volt, 50 Hz AC supply complete all as specified and directed.
S & F in repairs cabinet bulb suitable for refrigerator of size and capacity as on site complete all as specified and directed.
S & F in repairs magnetic contactor unit suitable for refrigerator of 165 to 310 ltr capacity complete all as specified and directed.
S & F in repairs freezer compartment door/ cover suitable for refrigerator of 165 to 310 ltr capacity complete all as specified and directed.
S & F in repairs ice tray with PVC cubicle seperator suitable for refrigerator of 165 to 310 ltr capacity complete all as specified and directed.
S & F in repairs compressor suitable for following appliances of any make/ model, as per exisiting on site, testing and commissioning complete all as specified and directed.
Split type AC of 1.5/ 2.0 ton TR capacity
Water cooler of 40/80 or 60/120 ltr capacity
Refrigerator of 165 to 310 ltr capacity
S & F in repairs condenser unit assembly suitable for following appliances of any make/ model including making of all connections complete all as specified and directed.
Split type AC of 1.5/ 2.0 ton TR capacity
Water cooler of 40/80 or 60/120 ltr capacity
Refrigerator of 165 to 310 ltr capacity
S & F in repairs PCB circuit board suitable for non invertor AC of any make/ capacity, as per exisiting on site, complete all as specified and directed.
S & F in repairs PCB circuit board suitable for outdoor units of inverter AC of any make/ capacity, as per exisiting on site, complete all as specified and directed.
S & F in repairs PCB circuit board suitable for indoor units of inverter AC of any make/ capacity, as per exisiting on site, complete all as specified and directed.
S & F in repairs PCB circuit board suitable for split/window AC including changes of necessary item as required, complete all as specified and directed.
S & F in repairs power contactor suitable for 1.5/ 2 ton split/window type AC, as per existing make, complete all as specified and directed.
S & F in repairs remote control suitable for 1.5/ 2 ton split/window type AC, as per existing make, complete all as specified and directed.
S & F in repairs overload protector relay as per sample, suitable for following appliances of any make/ model complete all as specified and directed.
AC, any type, of 1.5/2.0 TR capacity
Water cooler of 40/80 or 60/120 Ltr capacity
Refrigerator of 165 to 310 Ltr capacity
Deep freezer of 200 to 425 Ltr capacity
S & F in repairs thermostats suitable for the following appliances as per existing make complete all as specified and directed.
Water cooler of 40/80 or 60/120 Ltr capacity
Refrigerator of 165 to 310 Ltr capacity
Deep freezer of 200 to 425 Ltr capacity
S & F in repairs strainer of capillary tube suitable for following appliances of any make testing and commissioning complete all as specified and directed.
Split type AC of 1.5/ 2.0 ton TR capacity
Refrigerator of 165 to 310 Ltr capacity
Water cooler of 40/80 or 60/120 Ltr capacity
S & F in repairs cooling coil assy suitable for 180 to 310 Ltr capacity refrigerator, complete all as specified and directed.
S & F in repairs bimetal unit assy suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed.
S & F in repairs capacitors of following capacities suitable for ACs/water coolers/ refrigerators complete all as specified and directed.
Upto 8 Mfd
S & F in repairs PVC medium grade drain pipe of 15mm dia, for split AC, as per existing, complete all as specified and directed.
S & F in repairs copper tube 1/4", complete all as specified and directed.
S & F in repairs copper tube 1/2", complete all as specified and directed.
S & F in repairs copper tube 3/8", complete all as specified and directed.
S & F in repairs copper tube 5/8", complete all as specified and directed.
S & F in repairs insulation tube 1/4", complete all as specified and directed.
S & F in repairs insulation tube 1/2", complete all as specified and directed.
S & F in repairs insulation tube 3/8", complete all as specified and directed.
S & F in repairs insulation tube 5/8", complete all as specified and directed.
S & F in repairs potential relay box suitable for following appliances, as per existing, complete all as specified and directed.
Water cooler of 40/80 or 60/120 Ltr capacity
Refrigerator of 165 to 310 Ltr capacity
S & F in repairs PVC medium grade drain pipe of 25mm dia bore with 23 mm GI clamps, for water cooler complete all as specified and directed.
Repair/ maintenance of voltage stabilizers of capacity upto 5 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic changeover circuit etc, complete all as specified and directed. Note : Quoted rate shall be deemed to be inclusive of cost of replacing any minor defective parts so as to ensure smooth functioning of the appliance.
Supply and filling of refrigerant gas R-22 in factory sealed cylinders, complete as specified and directed.
Supply and filling of refrigerant gas R-134a / R-410 factory sealed cylinders, complete as specified and directed.
Supply and filling of refrigerant gas R-32 factory sealed cylinders, complete as specified and directed.
Supply and filling of Nitrogen gas upto 120 to 300 psi pressure in cooling appliances complete as specified and directed.
S & F in repairs split AC outdoor mounting stand, as per existing, complete all as specified and directed.
S & F in repairs split AC indoor stand, as per existing, complete all as specified and directed.
S & F in repairs flexible PVC insulated FR PVC multistranded, 3 core 4 Sqmm cables with copper conductor for voltage grade upto 1100 V complete all as specified and directed.
ELAN ENGINEERS (BID ID -3274393)
Shree Ram Enterprises (BID ID -3274623)
WELTRONENGINEERINGSERVICES (BID ID -3274987)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .