Agra Cantt.:-Electrification work in connection with Extension of platform no. 01 & 03 to high level for recoupment of shortfall in Minimum Essential Amenities (MEA) at AGC .
ELG-06-J06-2026-27
ELG-06-J06-2026-27
Open
8 Months
Agra, Uttar Pradesh
₹0
₹21,300
20 Jun 2026
20 Jun 2026
1 Jul 2026
1-Agra Cantt.:-Electrification work in connection with Extension of
Supply, erection, testing and commissioning of 400A MCCB 2 nos. as incoming and 1no.Auto changeover switch and 6 nos. 125 A MCCB and 4nos.63 A MCCB, 04 nos.32 A DPMCB and 4nos. 16 A DP MCB as outgoing complete with busbars, neutral link, etc. The price shall cover the cost of supply ,loading, transportation, unloading to the site, erection, testing and commissioning of 3 phase outdoor (Canopy/Hut Type) & double door type LT distribution panel comprising 2 nos. 400Amps FP MCCB as incoming with 1 no. 400 Amps automatic transfer switch (with auto, manual and by pass arrangements) and 6nos.125 Amps FPMCCB, 4 nos.63Amps FP MCCB, 04nos. 32Amps DPMCB and 4 nos.16Amps DP MCB as out going with 4 nos. copper bus-bars of size 50 x 7 mm, RYB indicator, digital multifunctioning Energy meter (KWH, Volt, Amp),selector switches, indicator lamps(LED type)with cable alley chamber and other associated accessories complete with cable 1 termination by cable gland, lug, nut bolt etc. All internal wiring in the panels shall be carried out using FRLSH wires. The MCCB shall be adjustable type having ground fault module with (Ics =100%Icu) and breaking capacity of MCCBs shall be 50 KA for 400A & 250 AMCCBs, 35 KA for125A & 63 A MCCB and10 KA for MCB. The enclosure of LT panel shall be fabricated of12SWG CRCA sheet, weather proof powder coated type with other accessories. The panel board shall be wall mounted /CC flooring with MS stand made of MS angle of size 50 mm x 50mm x 6 mm and skeleton type angle structures with holes for cable entry & exit as per site condition. The angle structure of panel should be covered with M.S. Sheet and duly painted. The panel board shall be properly earthed as per IS. The successful tenderer shall be required to submit circuit diagram and block diagram for the panel board and start fabrication after approval of the same by Sr.DEE (G)'s office. The LT panel shall be designed manufactured and all type tested in accordance with the latest relevant IEC(viz. IEC 61439 1-6,60947-2, 60898-12002 or latest)standards. The contractor shall submit original test report from CPRI/ERDA / Any other equivalent Govt. Testing Agencies.
Supply, erection, Testing & Commissioning of sub main consisting of 2x4 Sq. mm (P& N) PVC insulated and sheathed copper wire multristanded single core 1.1KV grade alongwith 1.5 Sq.mm PVC insulated copper wire 1.1 KV grade for earthing. (Quantity 1 Mtr.Equal to 02 Nos., wire of 4Sq.mm of 01 Mtr.each. and 01 No. earth wire 1.5 Sq.mm. of 01 M) (No cable joint is permitted inside the MS conduit pipe cable should be jointed with cable connectors inside the switch board)
Laying/Cleating erection, Testing & Commissioning of HT/LT Cable 03/04 Core on wall with all accessories & refilling of cable trench (asper IE rule) after laying of cable (Cable will be supplied by Rly free of cost at Consignee Depot)
Supply Erection, Testing and commissioning of power coated perforated cable tray of 300x50x1.6mm thick for cover in go open wiring/cable on surface of wall/FOB/COP complete with all other accessories required as per site.
Supply, Erection, Testing and commissioning of hot dip galvanized octagonal pole 5 5 Mtr. long confirming to IS 2629/BSEN ISO 1461 or equivalent including casting, muffing with cement concrete foundation (1:2:4) painting, earthing etc. the pole shall be complete with holes, Anchor bolts, bottom plate etc. As per Tech. Specification/site requirement, IS/IE rules of Double Arm type with 1.5 feet to 2 feet long type
supply, erection, Testing & Commissioning of energy efficient LED street light fitting 6 60 Watt outdoor complete street light fitting pressure die cast aluminum (PDC) body with make embossed on PDC body and complete with all accessories/ components and connection with PVC copper wire 2.5sq.mm size multicore and fixing arrangement as per site requirement. The technical parameters will generally conform to relevant Railway specification attached Annexure-II
Supply, Erection, Testing &Commissioning of 5 star rated super energy saving efficient BLDC Ceiling Fan, sweep size1200mm., down rod length asper site requirement, power 7 factor greater than 0.98 with Electronic Regulator & double ball bearing and MS Flat size50 X 5mm clamp of suitable size with hanging hook, nut bolt washer etc & Connection shall be taken with twin cord flexible PVC insulated copper wire size 48/0.2 mm., 03blades of Aluminum with power consumption not more than 28 Watt, Warranty 03years, required. 5 star rated BLDC super energy efficient ceiling Fan with double ball bearing, power 28 W. cat-Fan super efficient-ceiling BLDC
Supply, Erection, Testing and commissioning of Single earth electrode of 50mm dia 3000mm long GI Pipe class B conforming to IS: 1239 latest complete with earth box including connection from earth electrode to MDB/SDB/poles/With 8 SWGGI Wire
Supply, Erection, Testing and commissioning of Self contained Drinking water cooler with (Non-CFC refrigerant) energy efficient compressor cooling cap Litters/Hrs storage type, Capacity 150 Liters, rate of max energy consumption 1550W Square
Design, fabrication, supply, installation, testing and commissioning of glow signage board of size 4' x 2 or size as per site condition requirement. The signage board shall be single/double sided and fabricated from aluminum sheet of 1.0 mm thick with black powder coated paint. The board shall have 0.5 mm thick UV stabilized Bakelite white Penaflex sheeting duly stretched. The flex sheet shall be fixed with help of 25 mm x 25 mm size stainless steel angle of medium gauge on the border of both sides of the board. The flex should be illuminated from inside 10 by providing LED 18 Watt tube light fitting of make as per list enclosed. Minimum one no LED fitting for 4 sq feet area covered. The board shall have uniform brightness & shall be readable from a distance of 15 Mtrs. The Board shall be provided with a heavy duty connector strip of Bakelite material of 16-amp capacity duly fixed on the board. Provision shall also be made for 01 No earth terminal & suitable nos of louvers on both sides shall be provided for proper heat dissipation. A wire mesh shall also be provided to prevent entry of lizard & other insects. The matter, size of letter, language & color code of signage board shall be given by the concerned site engineer. The board shall be fixed/hanged using a suitable size of clamp made from GI flat in the platform cover shed as per site condition and connection given by a 3 core PVC insulated copper flexible cable through a PVC flexible pipe from the existing catenary/Light point.
Supply, Erection, Testing and commissioning of MS/PVC conduit pipe 25mm Dia 11 and1.6mm thick, recessed in the wall and through the wall by making hole and replastering the same in original condition complete with Tee, elbow, junction box, saddle & Other accessories for sub main wiring.
Dismantling & Removal of L.T. Existing Rail/Tubular pole and refilling the same with excavated earth and finishing the surface in its original condition after removal the existing Rail/Tubular pole handed over to concerned SSE/G store.
Excavation of cable trench:-This item shall be operated in conformity with IS:1255(latest version) i.e. code of practice for installation and maintenance of HT/LT cables. The price shall cover cost of excavation of cable trench in all type of soil for laying LT cables and back filling the same with sieved earth and finishing the surface in its original condition after providing sand, & bricks in cross position. For LT/HT cables the trench shall be 600mm wide x 1000mmdeep. In 13 trench the cable shall be covered with rivers and at a depth of 100mm below the cable and 100mm above the cable than placing well-burned bricks continuously in cross position through out the cable route in the ground. The bottom of the trench should level free from stones and sharp edge of rocks etc. At the termination a loop of 5 meter(approx.) cable shall be kept as allowance and loops rings be formed as per the site condition, in the ground, The cost shall include the cost of all materials i.e. sand, bricks, cable route markers (grouted in the earth firmly with cement concrete so that it can not be uprooted by miscreants) etc at 25m.interval and each turn of the cable.
Supply of HDPE Pipe 40mm (outer Dia)/33 mm (inner Dia) with couplers
Supply, fixing, testing & commissioning of MCB DB single phase with RCBO, m.s. enclosure, I/C -DP RCBO of 40Amp - 1No, O/G: SP MCB of 6A - 32A - 8Nos, as per specifications. 30 mA
Supply, Erection,, Testing and Commissioning of MCB SP-6A to 32A for individual octagonal pole for operating street light
Supply of material fixing and providing the Light/FTL/C.Fan/E.Fan concealed wiring point with 2.5 Sq.mm FRLSH/HFFR insulated and sheathed multistrand copper wire 1100 V grade, single core with 1.5sq.mm. PVC insulated copper conductor for continuous earthing in recessed 17 steel/PVC conduit pipe 25mm. 1.6mm.thick Dia bend, junction box etc. with ceiling rose batten holder, flush type 5A. switches mounted on white laminated phenolic sheet 3mm. thick cover on front of MS box made of 18 S.W.G. MS sheet of suitable size complete with replastering of wall if required wiring to be done in separate circuit. (Concealed wiring to be done on walls and roof if RCC roof is already constructed surface through PVC casing caping good quality double lock type wiring may be done.)
Supply, Erection, Testing & Commissioning of luminaire complete with all accessories, 18 18/20 watt, 04 feet LED tube light fitting & Tube with suitable current control driver circuit, suitable for surface mounting and connection with PVC copper flexible wire of 23/76 as per Rly. specification attached.
Supply, Erection, Testing and commissioning of 200mm ventilating fan.
Supply, Erection, Testing & Commissioning of material of concealed wiring point of 3 pin power socket 20 Amp./230 V in sheet steel enclosure with 20 Amp. Single pole MCB-SP, 3 pin 20 metal plug and wiring by 6 sq. mm. PVC insulated multistranded copper wire single core in recessed steel PVC conduit pipe 25 mm. 1.6mm. thick Dia with 1.5 sq. mm. PVC insulated copper wire complete with band, MS Junction Box etc. complete with replastering of wall. (Separate circuit to be drawn from SDB.)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril202227-04-2022.pdf
ATTACHMENT
ACS-1.pdf
ATTACHMENT
Correction Slip 02
ATTACHMENT
Correction Slip 03
ATTACHMENT
Correction Slip 04
ATTACHMENT
Correction Slip 05
ATTACHMENT
Correction Slip 06
ATTACHMENT
Correction Slip 07
ATTACHMENT
Correction Slip 08
ATTACHMENT
Correction Slip 09
ATTACHMENT
Correction Slip 10
ATTACHMENT
correctionslipNo.-02GCC13-12-22.pdf
ATTACHMENT
CorrectionslipNo.-03ofGCC-2022.pdf
ATTACHMENT
GCCCorrection07-08-2023SlipNo.4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5ACS-5.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-6.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-8.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-9.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo-10.pdf
ATTACHMENT
ACS-11.pdf
ATTACHMENT
Shramikkalyan.pdf
ATTACHMENT
Letterofcredit.pdf
ATTACHMENT
AnnexureVA1Policy.pdf
ATTACHMENT
AnnexureC.pdf
ATTACHMENT
TenderDocument_1.pdf
ATTACHMENT
Download all tender documents and submit your bid