Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹97.0 LAdmitted-Finance | -13.35% | ₹97.0 L | L1 | Admitted-Finance |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
20 Feb 2026, 1:00 pmClosed
SE PHED CIRCLE SRIGANGANAGAR
SE PHED CIRCLE SRIGANGANAGAR
Balance work for Rejuvenation,Renovation and providing,laying and jointing of Pipe line for providing FHTC in each house hold at RWSS 39 PS-A with defect liability period 1 year in sub division Raisinghnagar division Anoopgarh under JJM
2026_PHCJA_533302_1
SE/PHED/SGNR/2025-26/04
Open Tender
Civil Works
180 days
Anoopgarh
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
EXECUTIVE ENGINEER PHED DIV. ANOOPGARH
₹2.2 L
Yes
18 Mar 2026
29 Jan 2026
20 Feb 2026
29 Jan 2026
20 Feb 2026
29 Jan 2026
Part A ( Construction of Raw water Storage Tank )
Earth work excavation in F/T or drains I/C dressing of sides and ramming of bottoms lift upto 1.5 M I/C taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50 Mtr. Hard/dense soil.
Earth work in excavation for sedimentation cum storage tank including of excavated earth upto 200 M or excavated earth to be disposed outside of Headworks Boundary. If earth is to be disposed at more than 200M distance separate payment for each. Lead beyond 200 M distance will be payable as per PWD BSR effective from 1.1.2005. Disposed earth to be levelled and neatly dressed including stacking of useful material if any available during excavation for all kind of soil. Earth work to be carried out by means of mechanical system i.e. " Tractor craw" or any other mechanical system. No extra payment shall be made for any limit. This work, also involves dressing of sides & bottom for lining purposed which is to be done mannually, slope of sides is to be maintained as per specification & drawings.
Add extra for every additional lead 1.00 Km
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Brick masonary in foundation and plinth with bricks of class designation 75(local Ist class) in cement mortar 1:6 (1 cement : 6 coarse sand)
Brick masonary in foundation and plinth with bricks of class designation 75(local Ist class) in cement mortar 1:4 (1 cement : 4 coarse sand)
"Prepairing surface leveled & dressed to proper slope & laying over it tibba sand properly rammed and watered in 2 layers of 5 cm each. Providing and laying ISI marked 250 micron LDPE film as per ISS : 2508-1984 including interlocking by using thermal welding or ultrasonic welding or sealing tapes on the finished surface of compacted tibba sand. LDPE film to be anchored in parapet/Toe wall or any other structure etc as per direction. Over the LDPE film 15mm thick cement bajri single layer Ist class flat brick lining in cement bajri mortar 1:3 shall be provided with joints not more than 8mm wide. It includes providing wedicided & anti-termite treatment as per specification" and curing. Measurement of lining area will be payable. (Film used in anchoring is not payable).
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finished 12 mm thick in one coat.
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finished 20 mm thick in one coat.
Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size.50mm x 50mm x 3.15mm
b.CONSTRUCTION OF INTER CONNECTING SUMP WELL
Providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.
Providing, lowering, laying and jointing in trenches, standardlengths ISi marked AC pressure pipe class 15 manufactured byMAZZA process as per lS-1592-2003 or amended upto date withAC coupling and EPDM Rubber sealing rings of Type -3 as per IS:5382/1985 (Reaffirmed 1998) or amended up to date, including alltaxes sportation and freight charges, inspection charges,loading/ unloading charges, stacking of pipes, labour and materialsatisfactory hydraulic testing etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work and specials) Note: These pipes shall only be used for raw water conveyance main from Canal oulet to raw water reservoirs and interconnection works.150 mm dia Cl-15
Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated CI D/F Sluice valves of approved make (IS: 14846- 2000- amended upto date- For Sluice Valve) PN 1.0 class and CI Tail Piece- 2 Nos. (IS: 5531- 1988- amended up to date- For CI Plane Ended Specials) of same size of following dia complete including all material like Instren Rubber Sheet of thickness- 6.00 mm (ISI Mark)- For Rubber Sheet), MS Nut Bolts (IS: 1363 Part I-1984- amended up to date), CI Detachable Joint (IS: 8794- 1988 amended up to date), labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Nominal Dia. 150 mm
Providing and Fixing of PVC float arm with PVC flexible hose pipe 7.5 Mtr long and 150 mm dia. This also included tail pieces 150 mm dia on pipe's side and tail piece of required shape and 150 mm dia as hose pipe end for fixing float arm. All material should be confirming to relevant IS code. PVC float should be of capacity 100 Ltr. minimum. This job also includes dismantling of old system from storage tank. supply and fixing complete work in all respect.
Providing and fixing in position CI Puddle collar (approx. 1m length) inside the wall including all material labour as per Technical Specification of concerned IS Code 210-1978 (IS 1538:1993) and as per direction of Engineer:-150MM
PART B (P,L,J & Testing of Raising Main Pipe line(HDPE PE-80, PN-06))
Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80 PN-6 110 mm dia
……………………….125 mm dia
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil For HDPE pipe line dia up to 110 mm
For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm.
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS, Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS: 6418, Fastners - CS, All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. Class PN 1.0 40 mm
Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date), Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Grey cast iron of grade IS:210/FG200 ,Float- LP ball & HP ball : AISI 304 stainless Steel, Float Guide- HTB1,Seat ring & Gasket - EPDM/NBR, HP Orifice & HP orifice plug : HTB2/ SS ,Bush: Bronze , Flanges as per IS/ BS, Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside, Fasteners - CS/ Galvanised steel ,Outlet of big orifice will have a screen to prevent Tamper of float, with CI metal seated D/F Non rising stem Sluice Valves as per (IS: 14846 amended upto date) PN 1.0 ratings Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work. Class PN 1.0 40 mm
Removing & Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block, all lead and lift as per general specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) b) 80 mm thick.
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.Bituminous courses
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Manually Operated CI Sluice valve of Class PN-1.0 Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 80 mm HW
--do-- 100 mm HW
--do-- 125 mm HW
Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer.
SITC of Bulk Flow Meter with removable mechanism class "B" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. BFM 100 mm
BFM 150 mm
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- (External Work) Medium Duty Pipes_100 mm dia nominal bore.
Construction of VTC Chamber
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Walls ( any thickness) including attached pilaster buttresses , plinth and string course
Centering & shuttering with plywood or steel sheets including struttings propping bracing both ways with wooden members removal of form work for up to floor three level for: Suspended floor, roofs, landings, staircases, balconies girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintels, beams etc.
Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)Thermo-mechanically Treated bars (Conforming of relevent IS code)
Supply and fixing R.C.C. Main holes cover with frame of approved make (Light duty).(450 mm Dia)
PART C ( Providing Fitting & Fixing of Pumpset)
Supply and installation of electric driven 3 phase mono block pump sets confirming to IS:9079 of make Kirlosker, Texmo, Crompton, Taro, Siemens, ABB or equivalent make for raw water etc with perfect alignment and testing of complete system following capacity and size. This work also includes fitting with delivery and suction pipe line including fitting material like Nut Bolt, Dhaga, Rubber Sheet etc (Excluding GI Pipe/MS Pipe, CI specials cost) Complete job as per direction of Engineer-incharge :- Mono block pump with Syn Speed 300-600 LPM/15-12m Head/3 HP
Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 operating at sync. speed 2900 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee. Centrifugal Monoblock Pump set (Single Stage) 12.5 HP
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- (External Work) Medium Duty Pipes_100 mm dia nominal bore.
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- (External Work) Medium Duty Pipes_80 mm dia nominal bore.
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6-.80mm
Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.0 100 mm dia
………………………..80mm dia
P & F foot valve of superior quality and approved make with fittings : 80/100/125mm
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- ( External Work ) Medium Duty Pipes 20mm dia nominal bore
P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 20mm nominal bore.
Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size :20mm dia nominal bore
P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including placing on terrace( at all floors),making connection etc. complete of approved design. Details of cost for 500 litre
P & F bolts including nuts and bolts complete.
Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer.
Part D ( Providing, Installation and Commissioning of Electric Composit Panel Board )
SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear . Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator)
Supplying and fixing of Aluminium / Copper bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade Aluminium bus bar
SITC of quick make and quick break 3 pole current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push ( test ) to trip, including making connections with lugs & spreaders, etc. as required.up to 100 Amp , 10 kA, fixed O/L & S/C setting
SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.up to 125 Amp ,25/35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu
Providing and fixing of three pole power Contactor confirming to IS 13947-4-1 IEC 60947-4-1. Standard coil voltage 110, 240, 415, 440V 50 Hz as per ISI marked/approved make L&T, GIC, ABB. Simenes Contactor AC3 rating (415) 32 Amp Motor output 3 phase 20 HP
Providing and fixing of three pole power Contactor confirming to IS 13947-4-1 IEC 60947-4-1. Standard coil voltage 110, 240, 415, 440V 50 Hz as per ISI marked/approved make L&T, GIC, ABB. Simenes Contactor AC3 rating (415) 12 Amp Motor output 3 phase 7.5 HP
P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. Up to 14 Amp
P & F thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.21 to 30 Amp
SF of 110/220 V, LED (22.5 mm dia ) Indicating lamp with integral circuit, terminal block, including connection etc. as required. Red/yellow/Green colour
P & F push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Luminous type Red , Yellow, Green, Amber
Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 10 SWG copper. Wire
SF of (0-500) V range Volt meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type
SF of CT operated direct reading type Ampere meter on existing panel , making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A
SF of Current Transformer , with all necessary support in existing panel including connection etc. as required. up to 150 / 5 Ratio , 5 VA , class 1 accuracy
P&F of RCBO with overload, short-circuit and earth leakage protection ISI marked (IS12640)/ conforming to IEC 61009/1 complete in all respect including making connections, testing etc. as required. Two pole 100/300mA sensitivity 16 A rating
P&F 240/415 V Residual current circuit breaker conforming to IS:12640:1988/ IEC 61008 on existing board/sheet including making connections, testing etc. as required Two pole 30 mA sensitivity 25 A rating
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 1 x 1.5 sq.mm
1 x 2.5 sq.mm
1 x 4.0 sq.mm
1 x 6.0 sq.mm
Supply and laying PVC insulator submersible cable 3 core copper conductor of superior quality making connection etc in the following size as per related code, ISI Marked. 3 core 6.0 Sq.mm
Supplying and making one end termination with heavy duty single compression brass gland SIBG type, heavy duty Copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required of size. 2 x 2.5 sq.mm
2 x 4.0 sq.mm
2 x 6.0 sq.mm
P&F 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C/ D tripping characteristic) ISI marked IS 8828(1996)]/ conforming to IEC 60898 in existing board/sheets including making connections, testing etc. as required. Single pole MCB 0.5 A to 5 A rating
6 A to 32 A rating
Double pole MCB 6 A to 32 A rating
Triple pole MCB 6 A to 32 A rating
SITC of microprocessor based three phase sensing power factor correction relay having following sensing capacity secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, metering facility as required. 6 to 8 stage sensitivity up to 50 milli Amp
P & F of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current , conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 7 to 10 KVAR
SITC of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR . including making connections with suitable capacity conductors/cables testing etc. as required. Heavy duty Three phase 440 V , 50 Hz capacitor (Bank)
Providing and fixing of Timer as per ISI marked/approved make L&T, GIC, ABB. Simenes Electronic Timer 240/360 volt 415 Hz for 3 to 10sec./9 to 30sec./30 to 120sec
Single phase Prevantor with automatic approved make L&T, Simenes, Vishnu.
Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 35.0 Sq.mm, 3.5 core
Part E (Construction of RCC CWR )
Construction of RCC Clear Water Reservoirs of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete.Rates for RCC Circular Flat Slab CWR, SBC 10T/sqm, seismic zone II . up to100 KL capacity
Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.150 mm
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
Providing, lowering, laying, aligning, fixing in position in pipe line, manually operated CI D/F Sluice valves of approved make (IS: 14846- 2000- amended upto date- For Sluice Valve) PN 1.0 class and CI Tail Piece- 2 Nos. (IS: 5531- 1988- amended up to date- For CI Plane Ended Specials) of same size of following dia complete including all material like Instren Rubber Sheet of thickness- 6.00 mm (ISI Mark)- For Rubber Sheet), MS Nut Bolts (IS: 1363 Part I-1984- amended up to date), CI Detachable Joint (IS: 8794- 1988 amended up to date), labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. Nominal Dia. 150 mm
Part F (Construction of RCC Slow Sand Filter\ with filter media complete)
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottom with lift up to 1.5m including taking out the excavated soil and depositing and reffiling of jhiri with watering, ramming and disposal of surplus excavated soil as directed within a lead of 50m in All kinds of soil.
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size).
Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
ᰀ戀ᬁ⨀ࠂ牐癯摩湩湡慬楹杮椠潰楳楴湯猠数楣楦摥朠慲敤漠挠浥湥⁴潣据敲整映牯删䍃猠牴捵畴慲汥浥湥獴甠瑰汦潯楦敶氠癥汥椠据畬楤杮挠牵湩
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters, buttresses plinth and string course.
Add extra for shuttering in circular work (in respective centering and shuttering items_Beams etc) item no 11
Add extra for shuttering in circular work (in respective centering and shuttering items_Walls) 20% item no 8
Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finished 12mm thick. One coat
Fixing of pipes for under drainge system including plugging pipes with CM 1:4 on one end and fixing other end in collecting channel with CM 1:4 with all Material etc.(Excl.cost of pipes) This job, also, includes Making 4mm dia holes in pipes @15 cm c/c in zig-zag patternhis and testing of under drainage system as per instruction of Engineer-in-charge.
Supply and charging of filter media (Gravel) as per department specification including screaming, washing with 5% HCL solution to make Gragel (Size 4 to 6mm, 8 to 12mm, 10 to 20mm - Hard Coarse Randhisar grit) free from silt, clay and other all imputries work to be executed as per scope of work fixed by the department at the time of tendering
Providing and Placing of new filter media as (i) Sand shall be hard and resistant quartz or quartzite and free of clay, fine particles, soft grains and dirt of any description. (ii) Effective size shall be 0.20 to 0.30 mm. (iii) Uniformity Coefficient not be more than 5.0 nor less than 3.0. (iv) Ignition loss should not exceed 0.70% by weight. (v) Soluble fraction in HCL acid shall not exceed 7.0% by weight, (vi) Silica content should not be less than 95% (vii) Specific Gravity shall be in the range between 2.55 to 2.65 (viii) Wearing loss shall not exceed 3.0%. and as per specifications given in IS: 8419 (Part-I). (ix) The sand should not contain more than 2% of calcium and manganese calculated as carbonate. Filter media (fine sand and coarse sand) should be processed through. Disindicator and dust seperator in automatic plant including screening of sand to desired. Specification and washing and cleaning of sand with water by aqua wash technology at quarry site. The sand shall not contain more than 5% acid soluble matter as determined by solubility test in Appendix B of IS: 8419 (Part-I) (Fine sand 0.2 to 0.3mm and coarse sand 1.0 to 1.7mm)
Providing 90mm dia uPVC CL-3 pipes of approved make.
Finishing walls with water proofing cement paint of required shade including all scaffolding. : New work (Two or more coats applied @ 3.84 kg/10 sqm).
Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).
b.Clear water Chamber
Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottom with lift up to 1.5m including taking out the excavated soil and depositing and reffiling of jhiri with watering, ramming and disposal of surplus excavated soil as directed within a lead of 50m in All kinds of soil.
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finished 12mm thick. One coat
Finishing walls with water proofing cement paint of required shade including all scaffolding. : New work (Two or more coats applied @ 3.84 kg/10 sqm).
Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 . 150 mm
Providing of all size CI Flanged Special like Tees, Bends, Reducers and Enlargers as per IS: 1538-1993 (amended up to date) requiring for laying, testing and commissioning of AC Pipe line as per Technical Specifications and as per direction of Engineer.
P & F G.I. Pipes with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. :- (External Work) Medium Duty Pipes_100 mm dia nominal bore.
Part G (P,L,J & Testing of Distribution Main Pipe line(HDPE PE-80, PN-06)
…………..do 100 mm HW
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil For HDPE pipe line dia up to 110 mm
Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.Bituminous courses
Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
Part H (Providing service connection in each house hold)
Providing service connection as per technical specification and standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of cement concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiri by using a concrete cutter machine; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 meter ; providing & fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS/PVC clamp with saddle piece, gunmetal ferrule 4.0 mm (ISI make) , valve (IS: 778) and specials with MDPE pipe PE 80 PN 12.5 as per ISO 4427 below ground level and GI 15 mm class B 1.19.1 Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm 1.19.2 House hold tap connections (ISI mark) above ground level ( max. length 3.0 mtr), P&F a Bib Cock (IS : 8931 Mark), Superior quality Brass 400 gm,15 mm nominal bore including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . In addition to the ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumer's property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45 cm below ground level, except in case of concrete/bituminous roads where minimum depth shall be 20 cm. For detailed specifications of MDPE pipes please refer section "Technical specifications" of bid document. General specifications of MDPE pipes shall be as under: • The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of testing material : 9080 with minimum equired strength of 8 Kg/sq.cm. • The raw material shall be Food grade quality Pressure rating shall be 12.5 Bar. • The pipes shall bear ISO marking. Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI Class B Pipe
Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers like i.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving licence/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator.
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.43 MB
TD_04.pdf
Tender Documents • 11.36 MB
BOQ_950440.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid