Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.1 L
Closing Date
19 Feb 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
14 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V = Advertised value of the tender in crores of Rupees N = Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any Signalling work involving trenching, cable laying, termination and outdoor wiring. Note 1: Tenderer may be required to submit the schedule of those works, Completion/Performance Certificates of which have been submitted by him/her in support of 30/ 40 / 60% (as the case may be) criteria of similar nature of work.
22 conditions · 12 needing a document upload
PAN card Copy should be enclosed.
Please submit the copy of the registration certificate as applicable, GSTIN certificate should be enclosed.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Firm has to submit authorization letter for uploading documents on IREPS in case he/she is not an authorized person.
Contractors are allowed to make payments against this tender towards tender document cost and earnest money only through only payment modes available ON IREPS portal LIKE net banking, debit card, credit card etc.Manual payments through Demand draft, Banker cheque, Deposit receipts, FDR etc. are not allowed.
Copy of PAN number and GSTIN number should be submitted.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenders shall be treated as NULL & Void.
(i)Tenderers will examine various provisions of the Central Goods and Service Tax Act, 2017(CGST)/Integrated Goods and Service Tax Act,2017(IGST)/Union Territory Goods and Service Tax Act,2017(UTGST)/respective states State Goods and Service Tax Act(SGST) also, as notified by Central/States Govt. and as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit(ITC) likely to be availed by them is duly considered while quoting rates. (ii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority. (iii) In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism(RCM) and deposit the same to the concerned authority.
Tenderer should go through Annexure 1 & 2 of Tender Notice (attached in Tender Document)for list of documents required to be uploaded along with the offer.
Signalling work i.c.w. Provision of Safety fencing (Anti crash Barrier/RCC wall, etc) in BSB-BTP from Km 772.601 to Km 789.00 & BTP-ZBD section from Km 789.00 to Km 824.00 & in KS-TLGR section from Km 852.00 to Km 880.00(Vande Bharat Route) of Lucknow Division of Northern Railways."
106-Sig-Tender-59-2025-26
106-Sig-Tender-59-2025-26
Open
Works - General
300 Days
Lucknow, Uttar Pradesh
₹0
₹2.1 L
19 Feb 2026
29 Jan 2026
53 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,21,69,035.08 | ||
| — | 22000.00 | — | — | ||
| Excavating and refilling of trench to the level of ground with rammed earth asper Drg. No.(NR/S&T/Con/1.1/97A) so as not to form a drain 0.3 Mtrs wide & 1mtr deep on both side of the station alongside thetrack. It shall conform to the safe distance as persignalling and cable plan in all type of soil, it also includes clearence of roots of trees and bushes. | — | — | — | 10,47,860 | |
| — | 178000.00 | — | — | ||
| Laying of signalling/Telecom/power cables of different sizes as per attached guidelines (Drg. No.(NR/S&T/Con/1.1/97A1) or latest on signalling cable laying and as per cableroute plan approved by Railways through trenches, RCC pipe, DWC pipe, GI pipe etc andmeggering of cable before and after its laying of all type of outdoor cables. Contractor have to transport cable from any store of LKO division to site carefully. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways, as per instructions by Consignee. | — | — | — | 10,43,080 | |
| — | 176000.00 | — | — | ||
| Supply and laying of 2nd class bricks in the trench and laying as per Drg. No. (NR/S&T/Con./1.1/97A) and as per instruction of the site Engineer. | — | — | — | 10,98,240 | |
| — | 800.00 | — | — | ||
| Boring and trenchless cabling along with supply and insertion of DWC/HDPE self lubricated pipes as per RDSO Spec no. RDSO/SPN/204/2011 Ver 1.1 or latest of 120 mm nominal dia in the bore at the depth of 1.4 meter to 2.1 meter from formation level (level of earth below ballast) as per drawing and as directed by Engineer Incharge by trenchless technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. Inspection-RITES for Supply of DWC/HDPE pipe. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers with rubber O ring, 2. Spacers, 3. Tees. 4. Bend. 5. End Cap (1 no. =6mtr ,Straight pipe). (A) Thecost shall include horizontal boring through any intermediate obstruction, either natural or man made or any boundary etc. (B) The rate is inclusive of all the materials equipment and labour required for during trenchless horizontal boring under the railway track. Nothing extra shall be admissible on any account than the ratequoted above. (C) The Pipeis to be laid underrailway track/road /culvert. All necessary arrangement are to be provideand all precautionsare to beend is not deviated from the horizontal level line by more than 250mm in horizontalandvertical direction. (D) The rateshall be inclusive of direction and protection of underground utilities encountered during boring. (E) The payment for boring shall be made only when DWC/HDPE pipe are laid in the bore. | — | — | — | 11,18,672 | |
| — | 350.00 | — | — | ||
| Supply and fixing of GI Pipe as per specification No. IS:1239 (ISI Mark) make Jindal/Tata/Ajanta or Similar, size 75mm dia 3mm thick perforated at a distance of 20 cm or less of required length at culvert/bridges/along the cuttings, suitably concreted at both ends as per drg. No. (NR/S&T/CON/1.4/97) to be filled with chattered compoun. GI pipe clamps of MS flats, bolts and nuts, chattered compound to be supplied by contractor. Inspection-Consignee for supply portion | — | — | — | 3,11,699.5 | |
| — | 1300.00 | — | — | ||
| HDD boring and trenchless of 120 mm bore dia without HDPE pipe for laying in the bore at the depth of minimum 1.4 meter from formation level (level of earth below ballast) as directed by Engineer Incharge by HDD technology for laying of signalling /telecom/power cable under track /culvert etc. cable laying covered separately. | — | — | — | 12,60,623 | |
| — | 10200.00 | — | — | ||
| Supply of terminal block M-6 (ARA terminals) Block 25mm centre small M-6 terminal made of PBT as per IRS spec. No. IRS-S-75/2006 (Rev.2) or latest & IRS Drawing No. SA-23741/A (Alt. 4) or latest. Inspection-RDSO | — | — | — | 7,35,114 | |
| — | 5100.00 | — | — | ||
| Termination of all the cores of all type of outdoor cables after its laying on both end.This also includes preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends.Proforma for testing and material for lacing to be supplied by the contractor. | — | — | — | 62,322 | |
| — | 38.00 | — | — | ||
| Supply of Apparatus case steel Single with 'E' type locks and key ward No 42 complete as per drawing No. RE/S&T/ALD/SK/219/82 & 221/82 or latest. Handle should be at the rate of one each 4 nos. apparatus case. Inspection: RITES | — | — | — | 7,16,517.36 | |
| — | 38.00 | — | — | ||
| Casting, concreting and curing of foundation and erection of App. Case single as per Drg. No (NR/S&T/Con/2.7/97). A layer of 3mm of Bitumin compound has to be provided between foundation and location box to prevent ingress of water in the base of location box.All material such a s cement, sand, aggregate & anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair work of foundation if required during inserting the cable for termination. | — | — | — | 1,67,881.34 | |
| — | 38.00 | — | — | ||
| Preparation of App. Case single not involving wiring of relays: Preparation & fixing of bakelite hylum sheet 910x800x6mm and Backelite shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts and bolts.This includes fixing of fuses, ARA terminal, fixing and jamming of cables with 2 inch thick salwood plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank and all cable entry points on location boxes, location huts, JBs relay room/battery room to be closed with suitable masonry Works covered with sand and plastering.Wiring description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including Backelite shelf, hylum board, salwood plank, wire and wiring material, non deteriorating type HRC fuses with bases, catenary wires, nuts and bolts and other items shall be supplied by the contractor and shall be as per the RDSO specn.(as applicable). ARA terminals only shall be supplied by the Railways. | — | — | — | 1,75,135.16 | |
| — | 160.00 | — | — | ||
| Supply and installation of earth electrodes as per std.practice. The item includes digging of pit in earth, 3 Mtrs. deep and fixing earth electrode pipe.Casting of cement concrete enclosures as per drg. No.(NR/S&T/CON/6.4/97) or latest. The soil treatment shall be done as per std.practice. The item includes provision of mild steel flat of size 35mm x 6mm (as per IRSEM) and nut bolted connection of MS flat with earth electrode. The other end of mild steel flat to be connected to block instrument, cable sheath of power equipment, signal base, apparatus case,CT rack / relay racks, other equipments asper the instruction of Engr. at site & IRSEM. Earth connection Signal & location boxes to be done Drg.No. 19-D6 of IRSEM App II or latest. Complete materials such as earth electrodes as per Drg. No. (NR/S&T/CON/6.3/97) or latest , cement, wiring material, nut bolt for connection & mild steel flat of size minimum 35mm x 6mm or 210 sqm as per SEM etc. to be supplied by the contractor. Inspection by - RITES for supply of earth electrode. (P/Earth pipe= Nos) | — | — | — | 5,61,377.6 | |
| — | 20.00 | — | — | ||
| Supply of Digital insulation Tester (Megger) 100V-1000V DC , Output Voltage-100V, 250V,500V, 1000V DC, Accuracy +- 5% , Resistance Range 200 M Ohm- 2000 M Ohm Accuracy +- 2% with internal rechargeable battery. Make Motwani , Philips, Rishabh, or similar reputed make. Inspection - Consignee | — | — | — | 1,32,069.2 | |
| — | 66000.00 | — | — | ||
| Loading, Leading & unloading of materials from store to another store as per instruction of consignee. All the material to be transported carefully without damage. Contractor have to do proper stacking of material and prepare list of material. | — | — | — | 3,68,280 | |
| — | 1.00 | — | — | ||
| Supply of electronic Cable Route Tracer of reputed make 3M Dynatel/ Aplab/ Stanley C-Scope/ RD or similar reputed make along with TC & GC, As per RDSO recomendation, consist of (i) Cable avoidance tool digital under ground cable & pipe locating receiver and cable avoidance tool. (ii) signal generator of signal transmission capacity upto 12W. (iii) Signal lamp accessory (iv) Carry bag . Item to be supplied after successful demonstration and approval of Railways.Inspection- Consignee | — | — | — | 3,22,211.1 | |
| — | 1.00 | — | — | ||
| Supply of cable fault locator for underground metallic S&T cable of reputed make 3M Dynatel /Andig/Aplab/ Stanley /Telemetrics or similar reputed make specification similar to (Test signal output1/2 Sine, Pulse width 5nsec to 2500nsec, MaxRange:15000m, Filter cut-off Frequency:150kHz (High Pass Filter),Gain:0 to 63dB), RDSO/TEC recommended. Item to be supplied after successful demonstration and approval of railways. Inspection-Consignee | — | — | — | 3,71,573.97 | |
| — | 35.00 | — | — | ||
| Supply and provision of joints with the help of thermo shrink jointing (TSF-3) kit as per specifications, drawings and stipulations of tender documents and as per approved cable route plan at various locations for 06 quad/04 Quad cable Jointing kit to be supplied as per RDSO Specification IRS:TC 77-2012 (Rev-3) or latest amendments. Inspection : Consignee for supply portion | — | — | — | 2,76,047.45 | |
| — | 30.00 | — | — | ||
| Supply & installation of Optical Fiber cable Joint enclosure as per RDSO/SPN/TC/68/2007 Rev. Amendment no. 1 or with latest amendment and splicing of optical Fiber cables (24 Fibers) and testing. This includes provision of joint pit (RCC/pre fabricated) as detail in the technical specification and as advised by engineer at site. Inspection : Consignee for supply item. | — | — | — | 4,41,747.9 | |
| — | 17.00 | — | — | ||
| Laying of HDPE duct in the trenches including in HDD/Manual Boring and supply pulling of Nylon rope through is at different places as per direction of engineer incharge/Site engineer.It includes Supply of HDPE duct outer dia 40mm & inner dia 33mm as per TEC Gr No. G/CDS-08/02 Nov /2004 with latest amendment with end cap to be provided along with the drum at both ends. (RDSO specs No. RDSO/SPN/TC/45/2013 Rev.2.0). Inspection by RITES for supply portion | — | — | — | 12,68,352.32 | |
| — | 17.00 | — | — | ||
| Blowing/Drawing of OFC/Power cable into HDPE pipe. | — | — | — | 1,93,823.46 | |
| — | 32.00 | — | — | ||
| Engaging mechanical excavators like JCB or other machineries for regarding and leveling the formation, Dismantling any infringing structures, clearing and removing debris etc., with all lead and lifts etc., complete and as per the instruction of railway representative at site. | — | — | — | 35,351.04 | |
| — | 28.00 | — | — | ||
| Shifting of Apparatus case Single: It includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at site. The work includes ensuring the safety of the signalling system, releasing the cables coils to give access for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor). | — | — | — | 1,33,152.32 | |
| — | 18.00 | — | — | ||
| Shifting of Apparatus case half: It includes the Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringment as instructed by the railway repsentative at site. The work includes ensuring the safety of the signalling system, releasing the cables coils to give access for shifting/ turning the location boxes. Necessary masonary work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site, if the existing earth connection to the location boxes are disturbed the earth wires shall be the properly reconnected. (All materials required for the work shall be supplied by the contractor. | — | — | — | 56,651.4 | |
| — | 20.00 | — | — | ||
| Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe/ bricks covered separately. | — | — | — | 1,44,733 | |
| — | 12.00 | — | — | ||
| Supply of GI boom as per RDSO Drg-S-11/600 2nd section confirming to RDSO/SPN/208/2012 (ver 2.0) or latest as per technical specification attached. Inspection- consignee | — | — | — | 64,969.68 | |
| — | 12.00 | — | — | ||
| Supply of GI boom as per RDSO Drg-S-11/600 3rd section confirming to RDSO/SPN/208/2012 (ver 2.0) or latest as per technical specification attached. Inspection- consignee | — | — | — | 61,550.28 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_1.pdf
ACSGCC22-231to6.pdf
GCCAdvanceCorrectionSlipno7-10_1.pdf
TD-59-2025-26SafetyFencingBSB-BTPBTP-ZBDKS-TLGRsection.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .