| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.7 LAccepted-AOC WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.0 L+₹3.8 L (13.8%)Rejected-Finance | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹33.5 L+₹6.2 L (22.9%)Rejected-Finance | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹34.4 L+₹7.2 L (26.3%)Rejected-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance not being lowest | |
| 5 | L5₹35.5 L+₹8.3 L (30.4%)Rejected-Finance | L5 | Rejected-Finance not being lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR/REPLACEMENT OF ROOF TREATMENT AND COMPLETE GI FITTING WITH WATER TANK FITTINGS FOR 1 WEC EETSU AND WEE UNDER GE (CENTRAL) DELHI CANTT-10
2022_MES_532451_1
GE/C-34/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹80,000
Yes
13 Aug 2022
21 Jun 2022
29 Jul 2022
21 Jun 2022
27 Jul 2022
5 Jul 2022
21 Jun 2022 - 5 Jul 2022
Amount
M&L for roof treatment as per the description below including dismantling/taking down existing roof treatment complete:- a) preparation of roof surfaces by removing all loose material /dust extra for carrying out water proofing treatment. b) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces. c) Laying APP (Atatic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm and apply two coat of silver shield bitumestic aluminum paint all as specified
M & L for PCC 25 mm thk type B-1, 1:2:4 (using 20mm graded stone aggregate) as in roof complete all as specified and directed.
Material and labour for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triplr layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description (Make : Syntex/Polywell) (ISI Marked)
Material and labour for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description (Make : Syntex/Polywell) (ISI Marked)
Material and labour for rotational moulded polyethylene water storage tanks white colour 2000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description (Make : Syntex/Polywell) (ISI Marked)
S&F 15 mm bore tank nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., all as directed.
M & L for brick work with Cement Mortar1:6 using sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed
M &L 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70 Kg per Itr, water ration 17 to 19 % by weight with compressive str as per IS 4031 part 6 applied as per the manufactore instr including necessaery cement screed and prepartion of surface to received ready mix plaster. Complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of putty complete all as specifed as direted by Engr-in-charge.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, roof truss and similar work con- forming to Fe.290.Gde-E-165
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
Disconnecting existing tanks 500/1000/2000 Litre, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately)
Dismentling plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering complete .
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Demolition and breaking up rain water pipes (CI,AC,PVC etc) set in any cement mortor of any diameter incl bends.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110mm bore complete.
S/F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete.
S&F in repair PVC (SWR) bends any radius, 110 mm bore complete.
S&F in repair PVC (SWR) bends any radius, 75 mm bore complete.
Dismantling loose concrete cover of RCC columns,beams,slads chajjas and the like as directed roughening and cleaning concrete surfaces with steel wire brushes washed with water and allowed to dry including de rusting of steel reinforcement to providing fabric mild steel wire mesh 75X75X3 mm dia as reinforcement to concrete surfaces applying adhesive admixture over steel mesh and providing minimium 40 mm thick (average thickness) guiniting mix using 1 part of ordinary portland cement 53 grade and 2 part of ghaggar sand mixed with the pressure of 2 to 2.5 kg per sqm by guinting machine and surfaces finised even and fair all as specificed
Schedule of Credit
Som Nath Kakkar
M/s Amit Brothers
LAMBA ENTERPRISES
M/s SAAR ENGINEERS
SHIVA ENTERPRISES
a.k constructions
SHREE RAM BUILD TECH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .