Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22,884Accepted-Finance | L1 | Accepted-Finance AS PER BOQ | |
| 2 | L2₹55,705+₹32,821 (143.4%)Accepted-Finance | L2 | Accepted-Finance AS PER BOQ | |
| 3 | L3₹59,142+₹36,258 (158.4%)Accepted-Finance | L3 | Accepted-Finance AS PER BOQ | |
| 4 | L4₹59,645+₹36,761 (160.6%)Accepted-Finance GRAM POST MAWANA KHURD MAWANA MEERUT | MEERUT | UTTAR PRADESH | 245206 | L4 | Accepted-Finance AS PER BOQ | |
| 5 | L5₹60,606+₹37,722 (164.8%)Accepted-Finance | L5 | Accepted-Finance AS PER BOQ |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
5 Jun 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Distribution Circle II Saharanpur
Various work of running Sansad, vidhayak Nidhi and Navin Jila Vidyut Vikas Nidhi in area EDSD ITI.
2025_PVVNL_1023617_4
114/W/EDC II/SRE/2024-25
Open Tender
Electrical Works
Lump-sum
365 days
SAHARANPUR
Please refer tender document
2 documents required · 2 mandatory
₹1,180
Yes
SE EDC II SRE
₹5,000
Yes
3 Jul 2025
29 May 2025
5 Jun 2025
29 May 2025
5 Jun 2025
29 May 2025
Amount
Detail of Work
Safe cartage of PCC/ ST poles (up to13 Mtr.) from ESC, SRE/JE store to site of work at various sites including loading & unloading at both ends (Dist. Up to 40Km.).
Safely cartage of other complete line material / 11 KV XLPE cable / LT ABC cable (Except PCC /ST Poles) from ESC, SRE/ JE store to site of work at various sites including loading, unloading at both ends (Dist. Up to 40Km.)..
Safe cartage of 10/25/63/ 100 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends.(Dist. Up to 40Km.).
Safe cartage of 11 KV XLPE Cable of size 3x35/3x70/3x120/3x185/3x300 sq mm from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Up to 40Km.)..
Safely cartage of LT ABC Cable size 3x50+1x35+1x16/3x95+1x70+1x16/3x120+1x95+1x16 sq mm. from ESC,SRE, to the site of work including loading & unloading at both ends (Dist. Up to 60Km.)..
Erection of single support on PCC/ ST poles (up to13 Mtr.) Long with complete fitting of all accessories of 11 KV/LT line. complete.
Erection of double Pole on PCC/ ST poles (up to13 Mtr.) Long with complete fitting with all accessories .
Fixing of 11 KV stay rods by digging of pits in block of 600X600X300 mm. & with new brick and nozzling of stay wire 7/10 SWG and fitting the same on the pole
Concreting of stay rod in ratio 1:4:8 with Ist class with brick ballst with cement, sand
Providing and fixing of stone ped 300x300x75
Earthing of poles by earthing rod.
Providing All Type MS Clamp for ST/PCC Poles with nuts bolts made of new MS flat 50x5 mm best quality.
Providing of nuts & bolts of size.
Providing of LT shekel insulator of size 100x115mm
Providing of Dead end clamp with I-Hook
Providing of Suspention clamp with I-Hook
Providing of Piercing connector Diff.size
Providing of 11 KV cable terminations Kit out door & indoor of size 3x35/3x70/3x120/3x185/3x300 sq mm.
Removel of old weasel/ Rabbit condutor from the Existing 11 KV/LT lines with making roll of condutor and shifting the same to ESC, SRE/JE store including loading and unloading at both ends.
Laying, lifting, Stringing, sagging jumpring & binding of ACSR Weasel Conductor for 11KV/LT Line including complete.
Laying, lifting, Stringing, sagging jumpring & binding of ACSR Rabbit Conductor for 11KV/LT Line including complete.
Laying, lifting, Stringing, sagging jumpring & binding of ACSR Dog Conductor for 11KV/LT Line including complete.
Removel of 10/25/63 KVA T/F from the existing D/P after opening HT & LT connection and with shifting the T/F from the site to ESC, SRE/JE store including loading and unloading at both ends.
Safe installation of 10/25/63/100 KVA T/F on the double pole with complete fittings including making connections and commissioning.
Laying, lifting, Stringing, proper sagging LT ABC cable of size 3x50+1x35+1x16/ 3x95+1x70+1x16/ 3x120+1x95+1x16 sq.mm. including fixing of all accessories.
Laying, lifting, stringing proper sagging of 11 KV XLPE cable 3X35/3x70/ 3X120/3x185/3x300 sq mm of including complete etc
Making of 11 KV cable terminations Kit out door & indoor of size 3x35/3x70/3x120/3x185/3x300 sq mm.
Laying and making connections of LT PVC/AL.XLPE cable 4x16/4x25/4x35/3.5x70/3.5x150/ sq.mm. from T/F to double pole (approx to 20 Mtr).
Fabrication Charges of Angel & Channal.
Concreting of ST Pole SP-55, 11/13 Mtr. with cement concreting in block of 600x600x1500 mm in ration 1:4:8 with cement sand and Brick ballast size 1x1.5" with Plinth.
Dismantling of exiting PCC/ST Pole after opening of comlete accessories
Cutting of Chopping of tree branches touching the 11 KV/LT line.
M/s Raj Kishor Contractor (BID ID -5235575)
GYAS PAL CONTRACTOR (BID ID -5235759)
SHIV CONTRACTOR (BID ID -5235673)
SHREE RAM ENTERPRISES (BID ID -5235810)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .