Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-Finance GROUND FLOOR SHOP NO G 8 JAIRAM COMPLEX NEUGI NAGAR MALA PANAJI GOA 403001 | PANAJI | NORTH GOA | GOA | 403001 | ₹10.9 L | L1 | Accepted-Finance L1 Bidder |
| 2 | Not Admitted-Fee/PreQual/Technical KHASRA NO 128 SWASTIK AGRO INDUSTRIES COMPOUND VILLAGE SAMPATPUR JAFARPUR RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | - | - | Not Admitted-Fee/PreQual/Technical Others-Due to non submission of EMD in requisite form-EMD/MSE/BSD as per NIT document |
| 3 | Rejected-Technical SHOP NO 1 BASEMENT FLOOR 2ND MAIN CANARA BANK COLANY SHOP NO 1 BASEMENT FLOOR 2ND MAIN CANARA BANK COLANY NAGABHAVI MAIN ROAD NAGABHAVI MAIN ROAD | - | - | Rejected-Technical Not complied with similar work experience Technically disqualified |
| 4 | Rejected-Technical | - | - | Rejected-Technical Similar work experience,MAF and GST not submitted technically disqualified |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-Due to non submission of EMD in requisite form-EMD/MSE/BSD as per NIT document |
| Sl No | Description | Qty | Unit | AIRFLOW ENGINEERING L1 |
|---|---|---|---|---|
| 1.00 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 deg C (outdoor ambient temperature). 1 TR = 12000 BTU
Inverter Type - Cooling only
2.0 TR with 5 Star BEE Rating
Make: Hitachi/ Daikin/ Mitsubhishi/ OGeneral/ Bluestar/ LG | 18 | Each | 55,800 ₹10,04,400 Lowest |
| 2.00 | Supplying & Fixing of outdoor unit wall stand MS powder coated as reqd, as per standard practice, suitable for Split AC of 2.0 TR or equivalent capacity as per IS norms following industry norms. | 18 | Nos | 590 ₹10,620 Lowest |
| 3.00 | Supply, Installation, Testing and Commissioning of electronic voltage Stabilizer of following rating for operation on Single Phase 230 V, 50 Hz AC, Automatic Low & High Voltage Cut-off Protection, Wall Mounting Cabinet Design, Built In Thermal Overload Protection, Digital display shows input and output voltage, Input Voltage range: 195-245 V of 5 kVA capacity
Warranty: Minimum 1 year or higher as per OEM
Make: Bluebird/ Camipro/ V-Guard/ Microtek/ Servokon/ Everest | 18 | Nos | 1,947 ₹35,046 Lowest |
| 4.00 | Supply, Installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft drawn copper refrigerant piping for AC units, complete with fittings, with suitable supports like clamps/hanger, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required.
6.4 mm dia (OD) + 15.86 mm dia (OD) or suitable size as recommended by OEM, with tube thickness 0.8 mm with 13 mm thick insulation suitable for 2 Tr Hi-Wall Split AC
Make: Totaline/ Godrej/ Mandev/ Papriwal/ Kwality Tubes/ Carrier | 36 | Mtr | 803 ₹28,908 Lowest |
| 5.00 | Supply & fixing of 20-25 mm dia. or suitable size as recommended by OEM, ridged PVC drain pipe having 6 mm thick insulation along with Fitting Supports, Jointing and any other item required suitable for AC units Make: Supreme/ Finolex/ Ashirvad/ Astral | 50 | Mtr | 130 ₹6,500 Lowest |
| 6.00 | Supply & fixing of 4 Core x 2.5 Sq.mm or suitable size as recommended by OEM, ISI marked FRLS PVC insulated copper conductor cable for connection between IDU to ODU of Inverter AC.Make: Polycab/Havells/Finolex/RR Kabel | 40 | Mtr | 142 ₹5,680 Lowest |
Tender Value
₹11.4 L
EMD Value
₹22,878
Closing Date
21 Jan 2026, 11:00 amClosed
Executive Engineer (Electrical)
IWD Office IIT Goa
Supply, Installtion, Testing and Commissioning of Air Conditioners at IIT Goa
2026_ITG_893673_1
IITGOA/IWD/2025/27 dtd 14.01.2026
Open Tender
Electrical Works
Works
30 days
IIT Goa
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹22,878
Yes
20 Feb 2026
14 Jan 2026
22 Jan 2026
14 Jan 2026
21 Jan 2026
14 Jan 2026
14 Jan 2026 - 21 Jan 2026
Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 deg C (outdoor ambient temperature). 1 TR = 12000 BTU Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating Make: Hitachi/ Daikin/ Mitsubhishi/ OGeneral/ Bluestar/ LG
Supplying & Fixing of outdoor unit wall stand MS powder coated as reqd, as per standard practice, suitable for Split AC of 2.0 TR or equivalent capacity as per IS norms following industry norms.
Supply, Installation, Testing and Commissioning of electronic voltage Stabilizer of following rating for operation on Single Phase 230 V, 50 Hz AC, Automatic Low & High Voltage Cut-off Protection, Wall Mounting Cabinet Design, Built In Thermal Overload Protection, Digital display shows input and output voltage, Input Voltage range: 195-245 V of 5 kVA capacity Warranty: Minimum 1 year or higher as per OEM Make: Bluebird/ Camipro/ V-Guard/ Microtek/ Servokon/ Everest
Supply, Installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft drawn copper refrigerant piping for AC units, complete with fittings, with suitable supports like clamps/hanger, jointing/brazing including accessories, insulated with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required. 6.4 mm dia (OD) + 15.86 mm dia (OD) or suitable size as recommended by OEM, with tube thickness 0.8 mm with 13 mm thick insulation suitable for 2 Tr Hi-Wall Split AC Make: Totaline/ Godrej/ Mandev/ Papriwal/ Kwality Tubes/ Carrier
Supply & fixing of 20-25 mm dia. or suitable size as recommended by OEM, ridged PVC drain pipe having 6 mm thick insulation along with Fitting Supports, Jointing and any other item required suitable for AC units Make: Supreme/ Finolex/ Ashirvad/ Astral
Supply & fixing of 4 Core x 2.5 Sq.mm or suitable size as recommended by OEM, ISI marked FRLS PVC insulated copper conductor cable for connection between IDU to ODU of Inverter AC.Make: Polycab/Havells/Finolex/RR Kabel
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.47 MB
BOQ_939329.xls
BOQ • 0.32 MB
NIT27Merged.pdf
Tender Documents • 4.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .