Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹21.9 L+₹3.1 L (16.2%)Rejected-Finance 2284 30 BAJRANG NAGAR VFJ ESTATE JABALPUR 482009 | JABALPUR | MADHYA PRADESH | 482009 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹22.8 L+₹3.9 L (20.9%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹22.9 L+₹4.1 L (21.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
29 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
PROVN OF 62.5 KVA DG WITH AMF PANEL FOR POWER SUPPLY OF MPR AT AIR FORCE STATION JABALPUR UNDER GE(EAST) JABALPUR
2023_MES_630607_2
82654/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE EAST JABALPUR
₹32,000
Yes
18 Mar 2024
31 Jan 2024
2 Mar 2024
31 Jan 2024
29 Feb 2024
7 Feb 2024
31 Jan 2024 - 6 Feb 2024
Amount
Supply, installation, testing and commissioning silent Diesel Generator 62.5 KVA with AMF generating set 415 Volts, 3 phase 4 wire, engine as per IS: 10001/ 10002 and alternator as per IS: 13364 complete with foundation, relay panel and switch gears for automatic starting on main failure, control panel with necessary meters and sound proof canopy of capacity upto 62.5 KVA. Note:- Diesel Generator should be as per CPCB4+ norms.
Engine:- (a) B3.3 Series, 4 cylinder, In-line 4 stroke, radiator cooled engine. (b) Well designed air handling system with Dry type,heavy duty, replaceable paper element air cleaner with restriction indicator, Air to air aftercooling, Optimised turbocharger for increased altitude cpabilities. (c) Best in class fuel economy with Inline fuel pump with A1 class mechanical governing, Spin on fuel filter. (d) Standard integral set-mounted radiator system , designed and tested for 50 degree Celcius ambient temperature. (e) Full flow spin on lube oil filter. (f) First fill of lube oil and coolant. (g) Electrical starter motor with soft start engagement feature. (h) Battery charging alternator. (j) 1x12 V DC Battery.
Alternator:- (a) UC22 alternator frames from Generator Technologies & Equivalent (b) Brushes type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1. (c) 3 Phase reconnectable winding with 12 terminals brought out for connection. (d) Dedicated winding specially designed for 1 phase operation. (e) Better motor starting capability. (f) Best in class efficiency. (g) Compact design with sealed bearings for longer life and lesser maintenance. (h) Impregnation on all wound components for better mechanical strength.
Control Panel:- Control panel is manufactured with 16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts: (a) PS0500 Controller. (b) Aluminum bus bars with suitable capacity incoming/ outgoing terminals. (c) Indicating lamps for ‘Load ON’ and ‘Set Running’. (d) Instrument fuses duly wired and ferruled. (e) MCCB of suitable rating with overload and short circuit protections. PS0500 Features PowerStart PS0500 control is a microprocessor based generator set monitoring and control system. This control includes an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics. (f) Intuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps. (g) Remote Start-Stop. (h) Engine Metering: Oil pressure, Engine temperature, Starting battery voltage, Engine running hours. (j) AC Alternator Metering: L-L Voltage and L-N Voltage, Current (phase and total), kVA (phase and total) and Frequency. (k) Engine Protection: Low lube oil pressure, High/Low Coolant temperature, Battery Over/Under/Weak Volts, Fail to Crank/ Start, Sensor failure, Cranking lockout, Low fuel level. (l) AC Alternator Protection: Over/Under Voltage, Over/Under Frequency, Loss of AC sensing.
Silencer:- Critical grade silencer suitably optimised to meet stringent noise emission standards laid down by MoEF / CPCB4+
M&L for earthing with galvanized steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 40mm bore GI pipe medium grade including necessary fittings for protection of earthing strip, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear incl 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth strip alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 50sqmm, 3.5core including jointing materials such as cable glands & lugs etc and testing on completion complete all as directed.
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70sqmm, 3.5 core including jointing materials such as cable glands & lugs etc and testing on completion complete all as directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable, GI strip etc including forming bottom surfaces required as per site conditions or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 sq metre in plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated material (Soil) not exceeding 50M and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. (Note : Punned thickness shall be considered for the payment purpose.)
Supplying and laying unreinforced precast concrete cable cover , Class LV, Type - I, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed.
S&F On load Manaul change over switch 415V in sheet metal enclosure 4 pole of capacity 400 Amps complete all as specified and as directed. .
Supply, Installation, testing and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX of size not less then 2 m width X 1 m heigth X 0.5 m depth,made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection, Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete with internal connection with suitable size of cable, cable lugs and cable glands, PCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–
(a) Aluminum bus bar 400 Amps - 01 Set
(b) MCCB 250 Amps,4 pole 36 KA, Adjustable thermal & fixed magnetic setting (Incoming)- 01 No.
(c) MCCB 125 Amps,4 pole 25 KA, Adjustable thermal & fixed magnetic setting (Outgoing)- 01 No.
(d) MCCB 100 Amps,4 pole 25 KA, Adjustable thermal & fixed magnetic setting (Outgoing)- 01 No.
(e) 3 Phase LED Digital Ammeter Class 1.0
(f) 3 Phase LED Digital Voltmeter Class 1.0
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified & directed.
M&L for forming embankments in soils including raising (or lowering) earth, spreading in layers n.exc 30cm thick, watering, ramming/rolling and finishing to required size, shape, camber etc n.exc 1.5mtr high from base complete all as specified and as directed. ( Notes : (i) Earth obtained from excavation(as approved by GE) shall be used for forming embankments. (ii) Compaction of earth filling shall be carried out at OMC and degree of compaction at OMC shall not be less than 95%.)
Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface using broken boulders or stones complete all as specified and directed
M&L PCC (1:4:8) type D-2 ( using 40 mm graded crushed stone aggregate) as in sub base, Mass Concrete complete all as specified and directed.
M&L Stone kerb of machine pressed coloured precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate, block of size 30cmX30cmX15cm finished at top in bullnosed shape and finished surface even and smooth using coloured pigment and jointed in CM (1:6), struck finished, including application of two coats of paints in zebra pattern complete all as specified and directed.
M&L for machine pressed precast concrete Interlocking paver block, glossy finish, in grey cement with pigment conforming to IS 15658-2006, 80mm thick, M-35 Grade of concrete , of size, shape, colour and pattern as approved by GE, laid over and including 50 mm thick sand complete all as specified and directed.
Excavating in post holes in soft/loose soil (or similar holes) each n exc 0.5 cu.m. getting out, returing, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 M and making good surface complete all as specified and directed..
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate in foundation, filling & mass concrete complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc .complete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St-240 complete all as specified and directed.
S&F MS Plates (plain or chequered), square cut or notched, forming holes, with riveted,bolted or welded attechment) conforming to Fe 410 -W (Gde -E -250) quality -B complete all as specified and directed.
S & F MS screw bolts (machine made) with hexagonal or square heads at one end and screwed at the other,or screwed bothends,each screwed end to be fitted with washers and one hexagonal or square nut, lenth of bolt exc 5cm but n exc 10 cm complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI Based corrugated steel sheet 0.50 mm thick(AZ-150) of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer over 10cm width or girth complete all as specified and directed.
S & F wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
M & L brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L 15mm thick rendering on fair faces of brick surfaces in CM (1:4) finished surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound, ISI Marked, all as specified and directed.
M&L Preparing newly plastered surfaces of walls and applying two coats of cement base paint over a coat of appropriate primer complete all as specified and directed..
M&L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in Coping/bed plates,pintle blocks, bond stone (for stone walling), set in CM 1:6 complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290, (Gde E165) complete all as specified and directed.
Supplyin only chain link MS galvanisd fencing, any size or type, complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
M&L mild steel round bars 10mm dia and over, cut to length, bent to shape required , hooking ends and binding with and including mild steel wire (Annealed) not less than 0.9mm dia conforming to Fe-290( Gde E 165) complete all as specified and directed.
SHRI KRISHNA CONSTRUCTIONS
Vijay Engineering Works
M/S INDIA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .