GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR TO MCB DB TPN/SPN, PETTY REPAIRS AND CONNECTED WORKS AT RAKSHA VIHAR COLONY UNDER GE (I) R AND D KANPUR.
2021_MES_485503_1
8248/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
R V Colony GE I R and D Kanpur
As Per NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹14,000
Yes
4 Mar 2022
1 Nov 2021
1 Dec 2021
1 Nov 2021
29 Nov 2021
15 Nov 2021
Amount
Attending the complaints lodged by the occupants/users of electrification nature & rectification of the fault as per the complaint lodged by the user onward OH line LT/HT lines in any time (day and Night) in respect of main fixture /breakdown for light/fan/bell/light or power socket and LT/HT OH line etc complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/ Exhaust fans and other type of complaints to connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tape, screws , nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixtures to their position as dismantled and respect of item if required to be paid under respective item as required complete all as directed at site to th entire satisfaction of Engr-in-Charge/users. Note :- (a) Breakdown, repair/ replacement of switches, fan, regulator , replacing burnt/ damaged wiring , replacement of burnt MCBs and main switch , voltage fluctuation, current leakage, replacement of HT DOs/fuse, repair of street lights, repair of OH line, OH conductor and replacement of tube lights and no light etc will be attended with in 8 Hrs as urgent nature. (b) Any LT/HT breakdown complaints will be attended by skilled electricians/ Helpers as required at site without any delay & any time (day and night)
(c) The complaints will be attended by electricians & respective helpers during day and night hours without delay. (d) The complaint will be taken from complaint cell of war memorial colony. The rates are included for complaints for 60 scientist hostel, MES Key personnel qtrs, War memorial colony, Transit hostel, RCMA office and residential Accn and complaint cell of Raksha vihar colony. (e) All necessary tools & plants i.e. multimeter, tong tester, spanner set, wrench, screw driver set, combination plier, testing lamp set, drilling machine, bamboo ladder, blower/ vaccum cleaner, crimping tool, cutting and chasing tool, insulation megger , etc will have to kept by each tradesman engaged by contractor at his own cost. (f) Any accident/ mishappening occurred during the execution of work shall be responsibility of Contractor. (g) One MOBILE PHONE should also be provided by contractor to the each trademan engaged by him with incoming & out going facilities for normal and after working hours also so as to contact him in case of emergency during the entire period covered under the contract to keep liaison / communication with MES staff . (h) Complaint register and complaint slip shall be providing by the contractor duly printed with CA No and firm and the cost is deemed to be included in unit rate. (j ) Cost of material for replacement of new items shall be measured and paid separately under relevant items (serial item No 02.00 to 22.00) of Sch A/BOQ
Supply only switch piano flush button type, 6 Amp one way, 240 Volt, single pole , ISI marked conforming to IS 3854 style double colour series with cover plate complete all as specified and directed. Cona/ Anchor/SSK/Crabtree or as approved by GE (I).
Supply only Ding Dong sound door bell AC, 230 volts complete all as specified and directed. Code No. 3391/3421 of Cona or equivalent model in Anchor/SSK/Crabtree as approved by GE(I)
Supply only bell push switch piano flush button type, 6 Amp one way, 240 Volt, single pole , ISI marked conforming to IS 3854,style double colour series with cover plate complete all as specified and directed. Code No.7011 & 7301 of Cona or equivalent of Anchor/SSK/Crabtree or as approved by GE (I).
Supply only socket out let, 2 in 1, 5 pin, 6 Amp, 240 Volt AC, flush type, style double colour series with cover plate complete all as specified and directed. Make:- Code No. 7021& 7306 of Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only switch socket combination multipurpose 5 in 1, 6 pin, 6 and 16 Amp, 240 Volt AC, style duoble colour series" with cover plate complete all as specified and directed. Make:- Code No. 7096 & 7316 of Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only FASHION batten/angle holder with colour ring complete all as specified and directed. Make:-Code No. 2476/2471 of Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only FASHION ceiling rose with colour ring complete all as specified and directed. Make:- Code No. 2186 of Cona or equivalent of Anchor/SSK/Crabtree as approved by GE(I).
Supply only medium step type fan regulator 80 Watt, 240 Volt AC, style double colour series "style medium step" ISI marked complete all as specified and directed. Make:-Code No.7066 & 7306 of Cona or equivalent in Anchor/SSK/Crabtree as approved by GE (I).
Supply only FR PVC insulated, unsheathed, single core, flexible copper conductor wire suitable upto voltage grade 1100 Volt , ISI marked, conforming IS 694/1990 with latest ammendment in different colour of following sizes :- Make - Indo Asian (EON) or equvilants of Havells/Electron paragon/Plaza/Finolex/Polycab
(a) 0.75 Sq mm
(b) 1.5 Sq mm
(c ) 2.5 Sqmm
(d) 4.0 Sqmm
(e) 6.0 Sqmm
Supply only SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Cat No. Indo Asian optipro/Schneider (Electric)/Legrand as approved by GE (I).
Supply only MCB SPN, 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Indo Asian optipro /Schneider Electric/Hager /legrand as approved by GE (I).
Supply only MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Indo Asian optipro/ Schneider Electric/Hager as approved by GE (I).
Supply only MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make -Indo Asian optipro/ Schneider Electric/Hager as approved by GE (I).
Supply only Condensor of 2.5 MFD, 440 Volt AC , conforming to IS - 1709 for ceiling fans, Make - Epcos/ L&T/ Siemen/Universal
Supply only self adhesive PVC electrical insulation tape, ISI Marked, conforming to IS 7809, Part - 3, Section -1 of size as under :- (i) Length - 8 m (ii) Width - 18/19 mm (iii) Thickness - 0.125 mm Make - Steelgrip/Anchorgrip/Miracle or as approved by GE(I)
Supply only LED lamp retrofit 12 Watt, 230 volts,50 HZ,AC supply with base holder B22 white colour with polycarbonate body and aluminium heat sink complete all as specified and directed . Make Wipro/Philips/havells/C&S.
Supply only LED lamp retrofit 7 Watt, 230 volts,50 HZ,AC supply with base holder B22 white colour with polycarbonate body and aluminium heat sink complete all as specified and directed . Make Wipro/Philips/havells/C&S.
Supply only LED light fitting trend wall mounted batten with extruded aluminum housing with intregated LED driver complete along with LED tube aluminum extrusion 18 watt complete all as directed and specified. Make:- Wipro cat part No WIO92128 and LL13-181-650/ Philips/ Havells as approved by GE (I).
Supply only LED tube aluminum extrusion 18 watt complete. Make Wipro cat No LL13-181-650/ Philips/ Havells as approved by GE (I).
M&L for cold shrinkable type cable end joint indoor type suitable for XLPE 95 Sqmm to 185 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed.
M&L for cold shrinkable type cable end joint outdoor type suitable for XLPE 95 Sqmm to 185 Sqmm 3 core cable 11 KV and testing all as specified and directed with terminate joint and jointing material all as specified and directed.
M&L for cold shrinkable type cable stright through joint outdoor type suitable for XLPE 95 Sqmm to 185 sq mm 3.5 core cable and testing all as specified and directed with terminate joint and jointing material all as specified directed.
M&L for cold shrinkable type cable stright through joint outdoor type suitable for XLPE 120 Sqmm to 185 Sqmm 3.5 core cable and testing all as specified and directed with terminate joint and jointing material all as specified directed.
Providing the cable fault locating Machine with necessary T&P at site for locating exact pin point of fault along with the length of armourd 1.1/ 6.6 /11 KV XLPE/PILCA insulated LT/HT cable complete all as required and directed at site
Supply & Fixing LED Mirror light fitting, 1x9 watt (TC-S) bulk head luminaries with lamp holders, ballast including LED, 50 Hz complete with all accessories including making electrical connection with PVC insulated flexible copper wire, three core of size 0.5 Sqmm not more than 0.50 m long including taking down old bulk head/sketch light fitting complete all as specified and directed. Make:- Bajaj/Philips/Havells as approved by GE (I).
Supply & Fixing in replacement of Bulk Head fitting in Engineering plastic housing with clear prismatic difusser (e-TARA series) of 1x10 Watt LED light luminaries complete, including 1x10 Watt IP65 LED including fixing on wall and making electrical connection with PVC insulated flexible copper wire, twin twisted of size 0.5 Sqmm not more than 0.50 m long complete all as specified and directed. Make:- C&S cat part No CG80IB10WLED or equivalent make of Bajaj/Philips/Havells as approved by GE (I).
SAKSHAM SUPPLIERS BUILDERS
M/S PASHUPATI TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .