Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹9.1 L+₹22,100 (2.50%)Rejected-AOC | L2 | Rejected-AOC BEING L2 | |
| 3 | L3₹9.9 L+₹1.0 L (11.9%)Rejected-AOC | L3 | Rejected-AOC BEING L3 | |
| 4 | Rejected-Technical NO 4 SRIRAMULU VILLA MULLAI STREET KANDAN NAGAR TIRUTTANI 631209 | TIRUTTANI | THIRUVALLUR | TAMIL NADU | 631209 | - | Rejected-Technical Not Recommended, since not enlisted in b(ii) category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Recommended, since not enlisted in b(ii) category |
| Sl No | Description | Qty | Unit | EASHWAR ELECTRICALS L1 | BR Engineering L2 | SRIRAM ELECTRICALS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, connecting and testing XLPE Insulated PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 120 sq mm 3.0 core. confirming to IS-7098, Part-II/2011 with latest amendments laid in cable trenches /Duct /Wall /surfaces /Pipe including compression gland, lugs as required at site complete all as specified and as directed | 20 | Metre | 2,160 ₹43,200 | 1,490 ₹29,800 Lowest | 1,750 ₹35,000 |
| 2.00 | Laying of One number PVC insulated PVC sheathed XLPE power cable 11 KV grade of size 120 Sqmm X 3.0 Core direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | 20 | Metre | 702 ₹14,040 | 510 ₹10,200 Lowest | 750 ₹15,000 |
| 3.00 | Supplying and fixing indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required of size 120 sq.mm | 2 | Each | 13,500 ₹27,000 | 5,940 ₹11,880 Lowest | 13,500 ₹27,000 |
| 4.00 | Providing and fixing GI pipes 80 mm dia complete with GI fittings including trenching and refilling external work etc. | 12 | Metre | 810 ₹9,720 Lowest | 810 ₹9,720 Lowest | 900 ₹10,800 |
| 5.00 | Material & labour for disconnection of all electrical connections including earth strips from existing serviceable Transformer 11KV/433 Volts, floor mounted at T-54 Substation Technical Area CVRDE, Loading the Transformer carefully by using crane, Transport the same to the location where specified (near Bldg No- P-11) / MRS Technical Area CVRDE and connect all the electrical / earth connections including testing after completion all as specified and as directed. | 1 | Each | 27,000 ₹27,000 | 10,860 ₹10,860 Lowest | 17,000 ₹17,000 |
| 6.00 | Laying of one number PVC insulated PVC sheathed XLPE Power cable 1.1 KV grade of size from 185 Sqmm to 400 Sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | 150 | RM | 405 ₹60,750 Lowest | 440 ₹66,000 | 750 ₹1,12,500 |
| 7.00 | Supply, connecting and testing XLPE Insulated PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core. confirming to IS-7098, Part-I/2011 with latest amendments laid in cable trenches /Duct /Wall /surfaces /Pipe including compression gland, lugs as required at site complete all as specified and as directed. (02 Runs from Transformer to Main LT PB) | 60 | RM | 2,340 ₹1,40,400 | 1,220 ₹73,200 Lowest | 1,400 ₹84,000 |
| 8.00 | Supply, connecting and testing XLPE Insulated PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core. confirming to IS-7098, Part-I/2011 with latest amendments laid in cable trenches /Duct /Wall /surfaces /Pipe including compression gland, lugs as required at site complete all as specified and as directed. (from Main LT PB to Sub panels I & II). | 90 | RM | 1,260 ₹1,13,400 | 640 ₹57,600 Lowest | 740 ₹66,600 |
| 9.00 | Surface excavation not exceeding 30cm in depth but exceeding 1.5 Mtr width as well as 10 Sqm on plan including getting out and disposal of excavated earth up to 50 Mtr and lift up to 1.5 Mtr as directed by Engr-in-charge for all kinds of soil | 30 | Sqm | 360 ₹10,800 | 90 ₹2,700 Lowest | 120 ₹3,600 |
| 10.00 | Material & labour for plain cement concrete (1:4:8) type D2 using 40 mm graded aggregate as in foundations, filling and mass concrete including demolition of old concrete of any description complete all as specified and directed. | 2 | Cum | 7,200 ₹14,400 | 5,460 ₹10,920 Lowest | 7,500 ₹15,000 |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
29 Sept 2025, 6:00 pmClosed
AGE I R AND D AVADI
AGE I R AND D AVADI CHENNAI 600054
UPGRADATION OF EXTERNAL POWER SUPPLY ALONG WITH ASSOCIATED ELECTRICAL WORKS FOR BLDG NO P-11 AT TECHNICAL AREA AT CVRDE AVADI
2025_MES_726661_1
8709/E8
Open Tender
Civil Works
Item Rate
180 days
AVADI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE I RD AVADI
₹19,400
Yes
30 Oct 2025
26 Aug 2025
2 Oct 2025
26 Aug 2025
29 Sept 2025
9 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .