Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹31.9 L+₹1.1 L (3.49%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹36.8 L+₹6.0 L (19.4%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹44.5 L+₹13.7 L (44.5%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L4 | Rejected-Finance L4 | |
| 5 | L5₹51.9 L+₹21.1 L (68.5%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Sept 2024, 6:00 pmClosed
Garrison Engineer (East) Jalandhar Cantt
Garrison Engineer (East) Jalandhar Cantt
REPAIR/ REPLACEMENT OF SECURITY LIGHTS/ STREET LIGHTS, JUNCTION BOXES INCLUDING CONNECTED E/M ITEMS AT WEST OF MALL ROAD
2024_MES_668238_1
GE/JULL/ET-43/2024-25
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
As per tender document
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹80,000
Yes
28 Nov 2024
31 Aug 2024
7 Oct 2024
31 Aug 2024
30 Sept 2024
16 Sept 2024
Amount
Repair/ rectification for street/ security light/ perimeter light/ flood light any type, any make and any capacity against complaints of received through telephone or in person to make the security/ street lights in serviceable & functional condition as intimated by JE in-charge by rectification/ trace out the fault which includes disconnecting connection wire, removing/ taking down of street/ security light fitting from wall/ bldg/ plinth/ LT/ HT PCC/ steel tubular/ swan neck poles/ octagonal poles upto 11 mtr height from ground level or any other location, bring to MES workshop, opening the screws, step opening, diagnosing the fault, connection wire or any other part in presence of JE (E/M) or Deptt rep etc, cleaning of light fitting/ glass/ acrylic cover, re-assembling, testing for functioning, shifting back to site and re-fixing on GI pipe bracket/ wall/ pole after repair, making necessary connections or tightening of loose connection on ACSR conductor/ in bar chamber/ in DB, including any type of repair in timer switch box as required to make the light fitting functional. The replacement of parts i.e. driver, SPD, LED lamp, LED panel, MCB contactor, or any other part if required shall be measured and paid separately under relevant item of BOQ.
Notes :- (a) Light fittings, flexible wire and LED driver, street light timer, MCBs, contactors, junction boxes or any other item etc if required to be replaced in repair shall be measured and paid separately under relevant items of BOQ. The quoted rate include cost of minor parts i.e. screws, thimble, insulation tape etc required. (b) Complaints shall be attended and rectified within 24hrs of receipt of complaint. (c) Repair of one light shall be measured as one unit for measurement. (d) Contractor will get make and sample approval of items required to be replaced mentioned at Srl item No. 09.00 to 17.00 here-in-after and will hand over to JE in-charge with all PV & TC within 30 days of start of work ensure repair of street light any time when required during currency of contract and these items/ material will be issued by JE (E/M) daily on actual assessment of complaints to replace the defective part and for accounting of items. The contractor will maintain register regarding details of daily complaints received, pending, rectified, items replaced on daily basis duly signed by contractor, JE etc.
(e) Old retrieved material shall be deposited to JE (E/M) in AGE (E/M) yard/ E/M workshop on same day and will be given to contractor at the time of RAR after necessary recovery under Sch of Credit. (f) The contractor or his rep will get complaints from JE/ Engineer-in-Charge on daily basis in morning to repair lights. The contractor/ his authorised representative will receive the instruction/ complaints from JE (E/M) regarding detail of security light to be repaired daily at 0900 Hrs. In case contractor/ his rep do not receive complaint in morning, a recovery as per relevant PS Clause unserviceable light shall be recovered which remains pending due to non-availability of contractor manpower. (g) Contractor will provide vehicle, ladder, reqd FOL any other tools & plants required at site at his own costs nothing extra will be admissible on account of this. (h) If number of lights found unserviceable at one location due to non-availability/ any defect in electric supply, then making of all lights functional by rectification of electric supply shall be measured as one unit. (j) The contractor/his rep will report back to JE on same day for feedback of complaints done/ rectified
All as per item No 1.00 here-in-before but for 12.5 Mtr high mast lights/16 Mtr height mast light incl bringing down of high mast light bracket down to ground level by suitable means motor/manual,(as available at site) dismantling/repair the lights after replacement of parts, assembling/ re- fixing the lights and taking up the light bracket complete with the help of motor or any type of manual labour work incl any disconnection/ connection of cables involved. Note: 1. The taking down of high mast light down, repair of one or more lights and taking up and fixing the bracket on top at one time will be measured as one unit for payment
Supply and fixing LED street light fitting 45 watts, made up of pressure die-cast aluminium housing with toughened glass/PC embedded lens with mandatory secondary optics lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, overall 4950 lumens CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W, having external potted Constant Current driver moisture resistant with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and with separate external Surge protection device 10 KV suitable for fitting on 40 mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified. Make:- Philips/ Crompton/ Bajaj/ Havells as approved by GE. Note:- The Contractor shall ensure the light fitting dia should be suitable for 40mm dia bore pipe. Contractor shall quote his rate accordingly.
Supply and fixing LED street light fitting 60 watts, made up of pressure die-cast aluminium housing with toughened glass/PC embedded lens with Pressure Die Cast Aluminium Housing with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W, having external potted Constant Current driver moisture resistant (installed in separate independent compartment) with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and with separate external Surge protection device 10 KV suitable for fitting on 40 mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified Make:- Philips/ Crompton/ Bajaj/ Havells as approved by GE.
Ditto as per Srl item No 4.00 above but of capacity 70 W.
Ditto as per Srl item No 4.00 above but of capacity 90 W.
Supply and fixing LED Flood light fitting 150 watts, made up of pressure die-cast aluminium housing with toughened glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W High power type .Fitting should be double driver moisture resistant, with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and separate Surge protection device 10 KV complete having fixing bracket clamp all as specified and as directed. Make:- Philips/ Crompton/ Bajaj/ Havells as approved by GE.
Ditto as per Srl item No 7.00 here-in-before but of capacity LED light Fitting 70 Watt. Notes for Srl item No 3.00 to 8.00 (i) All LED fittings shall be made in India and of standard size only. (ii) All LED fittings shall have supporting LM-79 & LM-80 test certificate from govt approved NABL accredited Lab showing all the parameters duly signed by the local office bearer of manufacturer. (iii) All LED fittings shall have 2 years written Warranty from local office bearer of manufacturer. (iv) The old unserviceable LED fitting shall be issued by JE-in-charge after deducting amount as per Sch of credit at the time of RAR. (v) The old unserviceable light fitting may be of lower wattage/ old specification, no claim will be entertained on this account.
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit , voltage band 150 volts to 270 volt (min), Efficacy > 110 lm/W power factor 0.90 suitable for existing LED street light of capacity 42W to 45 W complete all as specified and as directed. Make:- OSRAM/ PHILIPS/ CROMPTON/ BAJAJ/ HAVELLS Note :- The contractor shall have to procure the suitable driver of compact size to fit easily for existing LED light fittings. No claim of contractor will be entertained on this account.
All as per Srl item No 9.00 above but of capacity 30 W.
All as per Srl item No 9.00 above but but of capacity 60 W.
All as per Srl item No 9.00 above but of capacity 70/72 W.
All as per Srl item No 9.00 above but of capacity 90/100 W.
All as per Srl item No 9.00 above but of capacity 120/150 W.
Supply and fixing SPD 10 KV min ( surge Protection Device) suitable for street light / Flood light fitting for avoid surge protection voltage upto all as specified and as directed. by Engineer-in-Charge
Supply and fixing in replacement 3 pole contactors 40 Amps with coil voltage 240 Volts suitable for timer panels complete all as specified and as directed.. Make : BCH or equivalent in Havells/C&S/L&T/ Siemens/ Scheneider.
Material and labour for Astro timer of rating 20 Amp to replace existing unserviceable timer incl necessary connections complete all as specified and as directed.. Make- Siemens/ L&T/ Legrand.
Supply and fixing Astronomical Digital timer switch for switching on/off lights according to rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/ or fixed preset time, current capacity 16A, weekly program with 1 changeover (1 CO), Total 28 programs min complete in powder coated CRCA sheet enclosure of suitable thickness with MCB TPN 32 Amp min, 3 pole contactor 32 Amp and MCB for manual switching of lights, fixing arrangement i.e. DIN rail complete with necessary porcelain insulator for incoming and outgoing cable connections with reqd clamp duly painted to fix on pole complete all as specified and as directed.. Make : Siemens/ L&T/ Legrand/ Indonasian/ GIC/ Havells.
Supply and fixing junction box complete with fixing accessories. The Junction Box shall be insulated and made out of Polycarbonate/ Thermoplastic with glass fiber reinforced. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Junction Box Mini. Size 160 x 200 x 98mm minimum. The Junction Box with Knock out on four side wall. The Junction Box shall be rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998-1& IEC 60998-2-1, with one number 10 Amp MCB SP 10KA complete all as specified and as directed.. Make :- Cat Part No. KM 9250 Hensel/ Schneider/GE Power/ABB
Supply and fixing in replacement bracket made out of 40 mm dia bore GI pipe light grade tubing 1.2 metre long, and bent to shape at 120 degree angle with reqd holes for passing connection cable, fixed with clamps nuts and bolts, washer complete all as specified . (Clamps, nut, bolts and washers will be measured and paid separately).
Supply and fixing in replacement MCB C-Curve, 10 KA, SP 10 to 32 Amp, 240 volts including taking down the exiting unserviceable MCB and all the necessary electrical connections, all as specified and as directed. Make:- Legrand/ Siemen/ Scheneider/ ABB.
Supply and fixing in replacement MCB C-Curve, 10 KA, SPN 40 Amp, 240 volts including taking down the exiting unserviceable MCB and all the necessary electrical connections, all as specified and as directed. Make:- Legrand/ Siemen/ Scheneider/ ABB.
Supply and fixing in replacement MCCB 63 Amps, 4 pole, 16 kA with fixed thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase separator/ spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand/ Siemens/ Schneider/ ABB.
Supply and fixing in replacement MCCB 100 Amps, 4 pole, 16 kA with fixed thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase separator/ spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand/ Siemens/ Schneider/ ABB.
Supply and fixing in replacement MCCB 160 Amps, 4 pole, 25 kA with Adjustable thermal fixed magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/ phase separator/ spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand/ Siemens/ Schneider/ ABB.
Supply and fixing in replacement MCCB 200 Amps, 4 pole, 25 kA with Adjustable thermal Adjustable magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase separator/spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand/ Siemens/ Schneider/ ABB.
Material and labour for locating fault of LT underground cables of size 10 Sqmm to 35 Sqmm 3.5 core/4 core laid in trenches by excavating (upto 10 mtr of length) the faulty portion of cable, taking out to protection bricks or cover, sand and faulty cable for making of joints or repair to existing joint including all jointing material such as LT joint, ferrule and relaying after repair including refiling of sand and relaying of brick protection cover complete all as specified and as directed.. Note : LT joint will be measured and paid separately.
Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 25 -35 sqmm 3.5 core complete all as specified and as directed..
Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 50-70 sqmm 3.5 core complete all as specified and as directed..
Material and labour for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI Pipe up to 100mm mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge. Note: The GI pipe shall be measured and paid separately.
Supply and fixing galvanised pipe light grade (IS-1239) 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and as directed. Engineer-in-Charge.
Supply and fixing galvanised pipe light grade (IS-1239) 80 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and as directed. Engineer-in-Charge.
Supply and fixing galvanised pipe light grade (IS-1239) 100 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and as directed. Engineer-in-Charge.
Material and labour for preparation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alternate black & white strips of 30 cm width up to 1.5 mtr height from top of PCC coping and numbering of poles complete all as specified & directed by Engineer-in-charge
Material and labour for preparation of old painted surface of street Light bracket, clamp and nut bolt etc with one coat of aluminium oxide paint complete all as specified & directed by Engineer-in-Charge
Material and labour only for cutting / Pruning of tree branches 1.5 mtr all around the LT overhead lines of span not exceeding 50 mtr and around the pole obstructing the overhead line & removing/ disposing the branches to a distance not exceeding 200 mtrs to the entire satisfaction of Engineer-in-Charge. Note : The rate quoted include any type of T & P i.e. ladder, cutting machine, cutting axe etc required at site
Re-stretching of existing loose OH, LT ACSR conductor wire any type/ any supply including GI wire along the span of pole 2 to 6 wire for sagging within the permissible limit, including disconnecting cable connections, opening of binding wire, winding/ rewinding/joining with aluminium winding wire in case of breakage of conductor and restringing at same place as same phase or changing the location to use as neutral or other phase complete as directed and again fixing to insulators with binding wire and making outgoing electric cable connections. The Size of binding wire of same size as made up of conductor complete all as specified and as directed. by Engineer-in-Charge. Notes : (i) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during stretching. (ii) Cutting trimming of hanging/extended branches of trees upto a distance 1.5 mtr from the overhead HT/LT line and making the line clear upto the entire length of the re-stretched ACSR feeder including removal and disposing of the cut tree/branches 50 mtr away for the site as directed is deemed to be included in the quoted rate. (iii) Piece of conductor of suitable size required for connecting the broken conductor deemed to be included in the rates quoted by the contractor. (iv) Re-stringing of all wires/ ACSR in any number upto 6 wire shall be measured as one unit for the purpose of payment.
Material and labour for preparation of old painted surface of steel tubular poles 9/11 meter long with one coat of aluminium oxide paint complete all as specified & directed by Engineer-in-charge
Supply and fixing in replacement Aluminium thimbles suitable for 35 to 95 Sqmm UG cable, crimping and connecting with MCCB complete incl disconnecting cables and making necessary connections after fixing thimble all as specified and as directed.
Supply and fixing in replacement Aluminium thimbles suitable for 120 to 185 Sqmm UG cable, crimping and connecting with MCCB complete incl disconnecting cables and making necessary connections after fixing thimble all as specified and as directed.
Material and labour for painting of cross arms 0.60 mtr long with clamps in position on 9/11 Mtr long pole with of aluminium oxide incl preparation of old painted surface complete all as specified & as directed
Disconnecting XLPE/ PVC insulated armoured aluminium conductor cable connection fom ACSR, removing from the pole and Supply and fixing end termination outdoor heat shrinkable joint suitable for 35 to 50 Sqmm,3.5/ 4 core PVC/XLPE cable and refixing the cable along with pole and making the connection with ACSR conductor complete all as specified & directed. Note: The rate also include the cost for removing of loop from ground after necessary excavation and stretching out the loop.
Material and labour in replacement of PVC insulated PVC sheathed copper conductor cable of 0.75 Sqmm, 3 core complete for street light and making connections all as specified and as directed..
Taking down ACSR of any type and any size by opening binding wires, removing outgoing electric connections by opening cable connections, removing spacers as directed by Engineer-in-Charge. Note: The decision of Engineer-in-Charge will be final and binding regarding the no of spans/ length and no. of phase or neutral conductors to be removed/ taken down from site.
Supply and fixing aluminium conductor steel reinforced of size ferret/ mink or other size required at site in required length/ span for overhead lines on poles stretching/ stringing without kinks and bends, including fixing with insulators using aluminium binding wire (rates inclusive), jumpers, line tapes etc and making necessary outgoing cable connection etc complete all as specified and as directed..
Dismantling insulators any type, any size complete with opening of ACSR binding wire complete all as specified and as directed.
Supply and fixing pin type insulator 100mm height, 65mm dia for 1100 volts grade porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts complete all as specified
Supply and fixing in replacement shackle type insulator pressure porcelain vitreous white, brown or green insulator for 1100 volts grade complete all as specified and as directed..
Supply and fixing in replacement loop type insulator porcelain vitreous white or brown, for LT stay large size with overall dissensions 65x140 mm, clearance hole 20mm for 1100 volts grade complete all as specified.
Supply and fixing in replacement MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer including dismantling/ taking down existing MS work complete all as specified and as directed.. Note: Unexposed surface shall be given one coat of primer only.
Dismantling damaged concrete poles/ struts/ steel poles upto 11m height complete with necessary excavation work, dismantling/ demolition of RCC foundation/ coping and removing complete of any size, height and shifting for taking credit all as specified and as directed..
Supplying, erecting and fixing Pressed concrete poles 09 meter long 102 x 152 at top and 102 x 289 mm at bottom class 10 complete as specified including painting of poles upto 1.5 mtr height from coping with two coats of synthetic enamel paint black & white strips and numbering of poles as directed complete all as specified and as directed.. (PCC and earth work shall be measured & paid for separately).
Material and labour for PCC work (1:3:6) type C-2 using 40 mm graded aggregate in foundation of electric pole, etc. including necessary form work and fare finish to exposed surfaces without using extra cement etc. complete all as specified.
Material and labour for PCC work (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric pole, etc. including necessary form work and fare finish to exposed surfaces without using extra cement etc. complete all as specified.
Material and labour for Stay assembly complete with accessories as shown in electrical plate No. 1 including loop type insulator large size, stay clamps, stay plate 230x230x6mm complete all as specified and as directed.. Note- Excavation and Concrete shall be measured and paid separately
Material and labour for Galvanised steel wire stranded 7/2.24 mm or 7/1.6mm incl fixing complete all as specified and as directed.
Supply and fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 06 sqmm twin core flat cable in service incl Taking down/ out unserviceable conductor connection all as directed. Make:- CCI/ Finolex/ Gloster/ Polycab as approved by GE.
Supply and fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 10 sqmm twin core flat cable in service incl Taking down/ out unserviceable conductor connection all as directed. Make:- CCI/ Finolex/ Gloster/ Polycab as approved by GE.
Supply and fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 16 sqmm twin core flat cable in service incl Taking down/ out unserviceable conductor connection all as directed. Make:- CCI/ Finolex/ Gloster/ Polycab as approved by GE.
Supply and fixing wall/ Pole mounted bus bar chamber with copper bus bar current rating 250 Amp (Considering current carrying cap 1.15Amp/ Sqmm) 4 Nos made up of 2mm thick CRCA sheet suitable for 415 volt 50 HZ AC supply complete making all incoming and outgoing connections in CRCA powder coated steel enclosure of size 600x 400x300 mm complete incl one MCCB 4 Pole,200 Amp with phase extenders/spreader with fixing clamp legs made of MS iron frame all as directed by Engineer-in-Charge. Note:- The door shall have also slidings bolts for locking arrangement.
Supply and fixing wall/ Pole mounted bus bar chamber with copper bus bar current rating 160 Amp (considering current carrying cap 1.5 Amp/ Sqmm) 4 Nos suitable for 415 volt 50 Hz AC supply complete making all incoming and outgoing connections in CRCA powder coated steel enclosure of size 600x 400x300 mm complete incl one MCCB 4 Pole,100 Amp with phase extenders/spreader with fixing clamp as directed by Engineer-in-Charge. Note:- The door shall have also slidings bolts for locking arrangement.
Material and labour Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thickness buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip 32x6 mm as earthing strip by means of GI bolts, nuts, check nuts and washers incl surrounded on all sides by 15cm thick layer of charcoal dust, salt, incl earth strip protected by 40mm dia GI light grade pipe, PCC pit of 1:2:4 & reinforced PCC top cover 50mm thick, earth pit angle frame of size 25mmx25mmx3mm with excavation and earth work in any type of soil, light grade GI watering pipe 20mm dia with funnel and wire-mesh complete all to as shown in electrical plate no 3 of SSR Part I 2009 connected main switch board or as reqd at site all as specified and testing on completion. Notes : (i) The rate quoted include the cost of GI strip & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner. (ii) If the results are not found satisfactory, then 2nd earthing will be re-done without any cost payable to Contractor.
Material and labour Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thickness buried directly in ground (earth pit not less than 2.25meters deep below ground level) with top edge of the plate not less than 1.5meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of GI bolts, nuts, check nuts and washers incl surrounded on all sides by 15cm thick layer of charcoal dust, salt, incl earth wire protected by 15mm dia GI light grade pipe, PCC pit of 1:2:4 & reinforced PCC top cover 50mm thick, earth pit angle frame of size 25mmx25mmx3mm with excavation and earth work in any type of soil, light grade GI watering pipe 20mm dia with funnel and wire-mesh complete all to as shown in electrical plate no 3 of SSR Part I 2009 connected main switch board or as reqd at site all as specified and testing on completion. Notes :- (i) The rate quoted include the cost of wire & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner. (ii) If the results are not found satisfactory, then 2nd earthing will be re-done without any cost payable to Contractor.
Material and labour for Jointing of snapped/broken ACSR any type by opening disconnecting of outgoing cable connections complete incl opening of binding wires, jointing of snapped ACSR by using new Aluminium conductor of same type, re-stretching/re- stringing of ACSR from one side dead end point (any length) for permissible sag and fixing to insulators with binding wire and incl making connection of outgoing cables complete all as specified and as directed.. Notes :- (i) The jointing & re-stretching/ re-stringing of one ACSR wire shall be measured as one unit only. (ii) Cutting trimming of hanging/extended branches of trees upto a distance 1.5 mtr from the overhead LT line and making the line clear upto the entire length of the re-stretched ACSR including removal and disposing of the cut tree/branches 50 mtr away for the site as directed is deemed to be included in the quoted rate. (iii) Piece of conductor of suitable size required for connecting the broken conductor deemed to be included in the rates quoted by the contractor
Taking down LT cable of size Upto 35 Sq mm any type from Panel/Pole Junction box by disconnecting cable and taking out loop and refixing and making cable connections with Al lugs of proper size incl any type of excavation work involved as directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and as directed. by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and as directed. by Engineer-in-Charge
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed. by Engineer-in-Charge.
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable and trenches punned down to thickness of 18 cm complete all as specified and as directed.. Note: Punned thickness of 18 cm will be measured and paid
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and as directed. by Engineer-in-charge. Average compressive strength of individual bricks shall be not less than 75 Kgf/cmsq.
Taking down/ out unserviceable UG cables of any cross sectional area, any type, any make from trench/ from wall/pole/pulling through pipe by opening connections and joints including removing pipe, bricks etc of any description from trenches or fixed with walls/ poles, segregating serviceable bricks/ cable cover, cables etc and keep in safe custody for reuse, complete all as specified and as directed.. Note : Earthwork shall be measured and paid under appropriate items of BOQ.
Supply, laying, jointing and testing XLPE insulated, PVC sheathed , steel strip or wire armoured electric cable 1100 volt grade (heavy duty) with stranded aluminium conductor of size 10 Sqmm, 2 core laid in trenches, in floor, in duct, through pipes/ culvert or along the pole/wall under roads complete all as specified and as directed. Make:- CCI/ Finolex/ KEI/ Havells/ Polycab as approved by GE.
All as per Srl item No. 72.00 above but of size 25 Sqmm 3½ core
All as per Srl item No. 72.00 above but of size 50 Sqmm 3½ core
All as per Srl item No. 72.00 above but of size 150 Sqmm 3½ core
All as per Srl item No. 72.00 above but of size 185 Sqmm 3½ core
All as per Srl item No. 72.00 above but of size 300 Sqmm 3½ core
Material and labour for Locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE LT underground power cables of the rating 1.1 KV with the help of Pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of fault location necessary excavation and taking out of faulty cable for repair/ replacement of joint, relaying of cable/ cover & brick protection, refilling of soil and removal of surplus soil etc at Jalandhar Cantt all as specified and as directed.. Notes :- (i) The joint shall be measured and paid separately under relevant item. (ii) The qty of item will be executed at different times during currency of contract as directed by Engineer-in-Charge. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly. (iii) Fault should be detected and rectified within 24 hrs from intimation to contractor after that penalty should be made to contractor at the rate of Rs 1000 per hour in case of delay/ Contractor fails to arrange machine and rectify the fault.
Northern cable fault locatoers (BID ID -3121009)
GLOBAL ENGINEERS AND INNOVATORS (BID ID -3106583)
CHOUDHARY AND SONS (BID ID -3122298)
R K ENTERPRISES (BID ID -3118034)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .