Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.3 L+₹1.6 L (23.1%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | Rejected-Technical OPP ARMY CANTT ABOHAR 152116 PB | FAZILKA | PUNJAB | 152116 | - | Rejected-Technical Requisite document as asked in NIT nof full fill |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
26 Jul 2023, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
REPAIR/MAINT OF INTERNAL ELECTRIFICATION WITH FITTING/FIXTURE OF OFFRS MD ACCN OF BHAGAT ENCLAVE AT MIL STN SRI GANGANAGAR
2023_MES_606380_1
GE SGNR/TOK-34 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Sri Ganganagar(Raj)
E Class b(i) and for un-enlisted, refer NIT para 8.
7 documents required · 7 mandatory
₹500
GE Sri Ganganagar
₹26,000
Yes
18 Sept 2023
28 Jun 2023
28 Jul 2023
28 Jun 2023
26 Jul 2023
12 Jul 2023
Amount
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer - in - Charge.
M & L for concealed conduit point wiring complete for light on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes 60mm deep ,suitable length and 1.6 mm thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.
All as per Srl item No -02 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No -02 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 2 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed by Engineer - in - Charge.
All as Srl item No. 02 here in before but for one light point controlled by two ways switches complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 2 here in before but for call bell point complete all as specified and directed by Engineer - in - Charge.
M & L for concealed existing conduit point wiring complete for light on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in existing PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes, after cutting in wall chasing for onduits and sinking's for new sunken GI terminal boxes Min 50 mm deep, suitable length and 1.6 mm thickness for mountng, switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover fixed with cadmium plated screwed and cup washers, duly grouting and making th e good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuty conductor along with point wiring of 1.5 sqmm copper PVC insulated cable fo one light/fan point controlled by one switch and connected to common earth dolly complete all as specified and direced by the Engineer in charge.
All as per Srl item no -08 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No -08 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 8 here in before but for one socket outlet 3 pin 15 Amps on independent board with 2.5 Sqmm copper cable complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 8 here in before but for one light point controlled by two ways switches complete all as specified and directed by Engineer - in - Charge.
All as per Srl item No. 8 here in before but for call bell point complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge.
S & F switch piano flush type 5/6 Amps single pole two ways complete all as specified and directed by Engineer – in - Charge.
S&F bell push flush type 5 Amp complete all as specified and directed by Engineer – in - Charge.)
S&F Electronic bell AC 230 Volt single pole ding dong type complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F switch socket combination 6 Pin, 15/16 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F in replacement Industrial socket metal clad plug and socket with MCBs single pole 20 Amp complte all as specified and directed by Engineer - in - Charge.
S & F replacement modular switch 5/6 Amp Sngle pole one way, one module including modular cover plate with frame and metal flush box complete all as specified and directed by Engineer - in - Charge.
S & F replacement modular switch socket combination 5 pin, type 5/6 Amps 5 in 1 flush type including modular cover plate and metal flush box with frame complete all as specified and directed by Engineer - in - Charge.
S & F replacement modular switch socket combination 6 pin, type 5/16 Amps flush type including modular cover plate with frame and metal flush box complete all as specified and directed by Engineer - in - Charge.
S & F replacement modular switch 5/6 Amps single pole two ways complete all as specified and directed by Engineer - in - Charge.
S & F replacement modular socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S & F replacement modular bell push 5 Amp complete all as specified and directed by Engineer - in - Charge.
S & F replacement modular stepped type, fan regulator not less than 120 watt for ceilling fan 1200/1400 mm sweep complete all as specified and directed by Engineer - in - Charge.
S & F ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
S & F in replacement of existing light fitting with LED batten with aliminium housing and integrated electronic driver, 20/22 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge.
S&F in replacement security light fitting LED TYPE 25 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge
S & F in replacement angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S & F in replacement Water tight bulk head fitting LED 10 Watt, comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well, complete fitting with all accessories and following specification, including taking down old U/S bulk head fitting any type complete all as specified and directed by Engineer - in - Charge.
S&F replacement decorative wall light, brushed nickle finish fixture with OPAL glass diffuser including 4 watt LED filament lamp E14 base complete all as directed by Engineer-in-charge
S&F in replacement of LED mirror light fitting 1 x 10 Watt appx 2 feet long, environement friendly, including electric connection with using 2 core flexible copper conductor cable 23/.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specification including taking down old U/S light fitting any type complete all as specified and directed by Engineer - in - Charge.
S&F in replacement of LED Bedside light (white, 3000K) 3 watt flexible arm suitable for reading complete all as specified and directed by Engineer - in - Charge.
S & F speed regulator for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S & F LED lamp 9W, White/Red/Yellow/Blue/Green colour for angle holder complete all as specified and directed by Engineer - in - Charge
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in including PVC conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. (Note : PVC cable and PVC conduit shall be ISI marked)
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 4 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in including PVC conduit including 4.00 Sq mm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. (Note : PVC cable and PVC conduit shall be ISI marked)
S & F in repairs sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F in repairs sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘C’ series type suitable for 240 volts, AC supply 5 to 40 Amps S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S&F in repairs Sheet metal enclouser for doble door Vertical DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 4 Way 415 Volt ISI marked 250Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N1 Frame upto 125A ,Isolators and including give connection with wire and cable etc complete all as specified and directedby engineer -in-charge
S&F in replacement MCCB TP&N 63 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S&F in replacement MCCB TP&N 40 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S&F in repairs MCCB TP&N 100 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge
Excavation in trenches not exceeding 1.5 mtr wide and not ecxceedinf 1.5 mtr depth for laying of cables complete all as specified and directed by engineer in charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by engineer in charge.
Removal of Excavated material n exceeding 50 mtr and depositing where directed complete all as specified and directed by engineer in charge.
Supply and filling in Sand for Cable protection complete all as specified and directed by engineer in charge.
Supply and lay standard size bricks subclass B type complete all as specified and directed by engineer in charge.
Supply and lay in replacement jointing and testing and commissioning in replacement of 25 Sqmm x4 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ ducts /fixed on poles wall/laid under roads/ paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts and washers of GI and protection by provision of GI medium grade pipe 50 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /sqmm) and frame of angle iron 25mm x 25mm x6mm with lugs 02 Nos and with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcol filling test point made out of 40mm x 8mm FI with fixing arrangement funnel wire mesh and earth work inhard dense soil returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no. 3 of SSR part 1 and connection to earth test point including taking out unserviceable earthing with all accessories all as specified or indicated inluding testing on completion all as specified and directed by Engr -In - Charge
S & F Supply and lay GI pipe 40 mm bore light grade for portection of cable including provision of clamps, nut, bolts etc required for fixing pipe along pole / wall / laid under the road / laid under the floor or in trenches complete all specified and directed by Engineer-in-Charge.
S&F in replacement of meter box of size (0.9m x 0.9m x 0.2m) thickness 2.25 mm double door, single openig with lock arrangement suitable for fixing 04 Electric meter & VTPN DB box including taking down existing electric meters, refixing them with two single core PVC copper conductor unsheathed wire multistranded 4 sqmm properly painting complete and fixing in wall with suitable cutting cement work etc complete all as specified and directed by Engineer-in-Charge.
S&F exhaust fan made of sturdy engineering plastic of 250mm sweep 240 volt complete with louvers and shutter and mounted in suitable opening arrangement in wall and connectiong up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to distubed wall in cement mortar (1:4) white washing matching with existing colour etc. all as specified and directed by Engineer-in-Charge.
Note : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline. (ii) Contractor will furnish the performance warranty certificate along with name of dealer from the manufacturer for a specified period as recmmended by the company for the equipments mentioned against respective items. (iii) All LED lights should be marked with GE SGNR and date of fixing.(iv) The contracotr will liable for penalty of Rs 500/day if he fail to interain the complaint given to him on next day (v) The Contractor should provide testing report of the manufacturer for wire/lights brought by the contractor. (vi) The Cost of the testing of sample for manufacturer wire/lights fwd to lab will be borne by the contractor.
Singla Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .