Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC FATINGTAR LODHOMA DARJEELING 734201 | DARJEELING | DARJEELING | WEST BENGAL | 734201 | ₹1.5 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹1.5 CrRejected-Finance UDAYPUR P O KAMAJORA DIST UTTAR DINAJPUR PIN 733130 | RAIGANJ | UTTAR DINAJPUR | WEST BENGAL | 733130 | ₹1.5 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹1.5 CrRejected-Finance DARJEE PARA P O KRISHNAGAR DIST NADIA PIN 741101 | KRISHNAGAR | NADIA | WEST BENGAL | 741101 | ₹1.5 Cr | L3 | Rejected-Finance L3 |
| 4 | Rejected-Technical KANKEBONG BUSTY P O P S LODHAMA LODHAMA DARJEELING 734201 | LODHAMA | DARJEELING | WEST BENGAL | 734201 | - | - | Rejected-Technical Non-submission of required Statutory Documents. |
Tender Value
₹1.4 Cr
EMD Value
₹2.7 L
Closing Date
20 Feb 2026, 2:00 pmClosed
Chief Engineer (Hydel)
Office of the Chief Engineer (Hydel),Hydel Headquarters, Powerhouse Complex, Siliguri
Construction of two storied B-Type residential quarter (Phase-3) at Lodhoma Colony under Rammam Hydel Project, Stage-II, Dist. Darjeeling
2026_WBSED_988932_1
WBSEDCL/CEH/C/25-26/20 dtd 16.01.2026
Open Tender
CIVIL WORKS
210 days
Lodhoma
Please refer tender documents
4 documents required · 4 mandatory
₹0
₹2.7 L
11 Mar 2026
30 Jan 2026
23 Feb 2026
30 Jan 2026
20 Feb 2026
30 Jan 2026
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. V/P-1, I-2(a),(b) & (e)(1), PWD SOR (Building)
(b) Depth of excavation for additional depth beyond 1,500 mm and upto 3,000 mm but not requiring shoring.
e) Add extra for cutting lateriate/sandstone 1) Cutting with chisel
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. V/P-1, I-3(a), PWD SOR (Building)
Excavation in Hard Rock (blasting prohibited) Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal within all lifts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections as per Clause 301 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (Mode of measurement: pre works and post works . .v/p - 238, i- 2.01(b) of PWD SOR(Roads)
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal /Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charg V/P-12, I-13, PWD SOR (Building)
Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety In ground floor(a) 1:3:6 proportion' instead of ‘Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor - Pakur variety - 1:3:6 proportion. (III) Cement concrete with 32 mm down graded gravel excluding shuttering V/P-18, Sl. 45 PWD S.O.R (bldg.) 3rd corrigenda
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) V/P-2, I-4(A),5th corrigenda, PWD SOR (Building)
Pre-Constructional Anti-termite measures: (a) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.) V/P-5, I-10(a), PWD SOR (Building)
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm thick V/P-10, I-2(a), PWD SOR (Building)
Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof. V/P-10, I-3(a), PWD SOR (Building)
Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc.and stacking the material at site as directed. V/P-11, I-8, PWD SOR (Building)
Dismantling carefully wooden walling, flooring of ceiling and stacking dismantled materials as directed. V/P-13, I-17, PWD SOR (Building)
Dismantling carefully wood work in posts, postplates, rafters, partition etc., sorting and stacking serviciable materials at site and removing rubbish as directed. V/P-13, I-19, PWD SOR (Building)
Brick work with 1st class bricks in cement mortar.a) Ground floor(i) In foundation and plinth (1:4) V/P-15, I-8(a) &(b), 3rd corrigenda,PWD SOR (Building)
(ii) In Superstructure (1:4)
b) First floor (1:4)
c) Second floor (1:4)
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. a) Ground floor V/P-16, I-16, 3rd corrigenda,PWD SOR (Building)
b) First floor
c) Second floor
Plum concrete work with 40 % cement concrete with 30 mm down graded stone metal and 60 % stone boulder of size 150 mm and above, placed in position as directed excluding shuttering if any. ii) (1:3:6) proportion V/P-13, I-34 PWD S.O.R(bldg.), 3rdcorrigenda
Rubble masonry in cement (1:4) with hard dressed stones from approved quarries and clean, coarse and washed sand including carriage of all materials to site(b) In Fine dressed work in Building (i) In Ground Floor V/P-23, I-45.b.(i), 3rd corrigenda,PWD SOR (Building)
Ordinary Cement concrete (mix 1:2:4 ) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. (b) River bazree V/P-24, I-4(b), 3rd Corrigenda, PWD SOR (Building)
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (b) River bazree.(I)In ground floor
In 1st floor
In 2nd floor V/P-26 , I-10(ii), 3rd Corrigenda, PWD SOR (Building)
Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16 mm. dia rod complete including mending damages. Payment for damage and repair to be made separately. V/P-40, I-30, PWD SOR (Building)
Providing weep holes in Brick masonry / Plain /Reinforced concrete abutment,wing wall / return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications. V/p-304, I-13.03 of PWD SOR(Roads)
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(i) (Ground Floor)
(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work .(ii)1st Floor
(iii) 2nd Floor
(f) 25 mm to 30 mm shuttering without staging in foundation V/P-42,43, I-36 (c) & (f), PWD SOR (Building)
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(a) For works in foundation and upto roof of ground floor/upto 4 m .(i) Tor steel/Mild Steel. I. SAIL/ TATA/RINL
b) Reinforcement at 1st floor (upto roof level of 1st floor)In first floor (SAIL/ TATA/RINL)
Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and waterproofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department] V/P-45, I-8(a), PWD SOR (Building)
Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. V/P-45, I-9, PWD SOR (Building)
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint (1st coat after 4 to 5 days of concrete laying and 2nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately). (Chequering not required over concrete or painted surface). V/P-47, I-1, 3rd corrigenda,PWD SOR (Building)
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] V/P-26, 3rd corrigenda, PWD SOR (Building)
Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps. V/P-54, I-19, PWD SOR (Building)
Extra cost of labour for prefinished and premoulded Nosing to treads of steps, railing, window sill etc. of Kota Stone. V/P-54, I-18, PWD SOR (Building)
Supplying,fitting & fixing granite slab 15 mm to 18 mm thick in floor, lobby, stair, landing and treads etc. over 20 mm (avg) thick base of cement mortar (1:2) laid with white cement slurry @ 4.40 Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor (c) Area of each Granite slab above 1.00 Square meter.(I) Ground Floor V/P-63, I-34.(c), PWD SOR (Building)
(II)1st Floor
Supplying and laying true to line and level Anti Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS4457-2007 and testing shall be made in accordance with IS:13630 [Non-modular sizes for tiles with Skid resistance> 0.5,Mohr's hardness> 5.0, Staining resistance: Class-1, WaterAbsorption: E<0.5%], MOR>35N/sq.mm in Internal area of building e.g.ToiletBlock, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2mm thick cement slurry at backside of tiles using [email protected]./Sqm orusing Polymerised Adhesive (6mmthick layer applied directly overfinished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/epoxy grout materials ofa pproved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor). a) In Ground Floor:Sizes 600mm x 600mm x 10mm with breaking strength > 1500 N V/P-80, 3rd corrigenda, PWD SOR (Building)
(II)1st Floor
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (D) Wall With Polymerised Adhesive and Epoxy grout pointing including spacer- 2mm. (a) Area of each tile above 0.09 Sq.m (using adhesive 4.5mm thick) (i) Coloured decorative.(I)Ground Floor V/P-36, 3rd corrigenda, PWD SOR (Building)
(II)1st Floor
Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor] (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (A) Deep Colour & White V/P-66, I-36.I.(A), PWD SOR (Building)
M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 16 Kg./sq.mtr and above.a) In ground floor V/P-104, I-13.a.(i), 3rd corrigenda, PWD SOR (Building)
b) In first floor
Collapsible gate with 40 mm x 40 mm x 6 mm Tee as top and bottom guide rail, 20 mm x 10 mm x 2 mm vertical channels 100 mm apart in fully stretched position 20 mm x 5 mm M.S. flats as collapsible bracings properly rivetted and washered including 38 mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. a) In ground floor V/P-106, I-18,3rd corrigenda, PWD SOR (Building)
Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Stainless steel pipe and base/cover plate with Stainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Stainless Steel railing per metre 6.5 Kg (approx) V/P-109, I-22,3rd corrigenda, PWD SOR (Building)
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected upto three decimals). (c) Sal : Siliguri. (I) In ground floor V/P-114, I-1.c., PWD SOR (Building)
(II) In first floor
Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mm x 47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x 15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mm x 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer's specification and direction of Engineer-in-Charge. V/P-115, I-4, PWD SOR (Building)
Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65 mm wide each and the entire frame fitted with 27.5 mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor: (a) 35 mm thick shutters (single leaf) V/P-124, I-12.a, PWD SOR (Building)
PVC Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x 30 mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mm x 25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliances i/c carriage of all materials taxes and all other incidental charges complete. V/P-135, I-27, PWD SOR (Building)
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (a) 40mm X 6mm, 200mm Length V/P-140, I-4.b, PWD SOR (Building)
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vi) 100mm. X 50mm. X 1.25mm. V/P-140, I-5.(vi)., PWD SOR (Building)
Iron socket bolt of approved quality fitted and fixed complete. (b) 100mm long x 10mm dia bolt V/P-141, I-8.b, PWD SOR (Building)
Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (a) 300mm long. V/P-142, I-10.i.(c), PWD SOR (Building)
Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete. V/P-143, I-16.(a), PWD SOR (Building)
Door stopper (Brass) V/P-143, I-19.(i), PWD SOR (Building)
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: (iv) 150mm long x 10mm dia. bolt. V/P-144, I-26.(iv), PWD SOR (Building)
Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete. (i) 250mm x 16mm dia bolt. V/P-145, I-28.(i), PWD SOR (Building)
Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: (iv) 75 x 63 x 3.2mm. V/P-145, I-29.(iv), PWD SOR (Building)
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (iv) 125 mm grip x 10 mm dia rod V/P-146, I-30.(iv), PWD SOR (Building)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar.(a) 20 mm thick plaster. i) In superstructure, ground floor V/P-50, 3rd corrigenda, PWD SOR (Building)
ii) In superstructure, 1st floor
iii) In superstructure, 2nd floor
(b) 15 mm thick plaster.i) In superstructure, ground floor
ii) In superstructure, 1st floor
iii) In superstructure, 2nd floor
(c) 10 mm thick plaster.i) In superstructure, ground floor
ii) In superstructure, 1st floor
iii) In superstructure, 2nd floor
Labour for Chipping of concrete surface before taking up Plastering work. V/P-192, I-1, PWD SOR (Building)
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per 100 sq.m. V/P-192, I-15, PWD SOR (Building)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor).(a) One Coat. (i) Water based interior grade Acrylic Primer V/P-195, I-7.a.(i), PWD SOR (Building)
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (a) One Coat.In Ground Floor: V/P-196, I-8.a., PWD SOR (Building)
In First Floor:
In Second Floor:
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two Coat).b) Premium 100% Acrylic Emulsion.In Ground Floor V/P-197, I-17.b, PWD SOR (Building)
In First Floor:
In Second Floor:
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. V/P-200, I-1.a, PWD SOR (Building)
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. V/P-200, I-1.b, PWD SOR (Building)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:(a) On timber or plastered surface :With other than hi-gloss of approved quality.(iv) Two coats (with any shade except white) V/P-200, I-2.a.(iv),b.(iv), PWD SOR (Building)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:(b) On steel or other metal surface :With other than hi-gloss of approved quality.(iv) Two coats (with any shade except white)
Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) V/P-204, I-5.b, PWD SOR (Building)
Labour for laying 150 mm to 200 mm boulder soling including rough dressing hand packing and ramming down small pieces in the interstics excluding rolling and preparing the bed to proper level and filling up all joints with sandy clay or earth. V/P-229, I-11, PWD SOR(Building) (Analysed)
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. iii) 5mm thick clear glass. V/P-243, I-9.(iii), PWD SOR (Building)
Supplying,fitting & fixing of 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film. Natural white For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. V/P-245, I-15, PWD SOR (Building)
(a) Supplying, fitting and fixing shower of approved brand and make.(i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model Tropical/Sumthing Special of ESSCO or similar brand). V/P-3, I-3.a.(i) PWD SOR (Sanitary & Plumbing)
(iii) Chromium plated shower arm 240 mm long (Equivalent to Code No. 536(A) & Model - Tropical / Sumthing Special of ESSCO or similar brand).V/P-4, I-3.a.(iii) PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). (i) 25 mm dia V/P-5, I-5, PWD SOR (Sanitary & Plumbing)
(ii) 40 mm dia
Supplying, fitting and fixing bib cock or stop cock. (a)(i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). V/P-6, I-7.a.(i) PWD SOR (Sanitary & Plumbing)
(a)(ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) V/P-6, I-7.a.(ii) PWD SOR (Sanitary & Plumbing)
(b)(i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand). V/P-6, I-7.b.(i) PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately).(a) For Exposed WorkPVC Pipes (Dia) (i) 15 mm V/P-12, I-19.(I) a PWD SOR (Sanitary & Plumbing)
(iii) 25 mm
(b) For Concealed Work PVC Pipes (Dia). (i) 15 mm
(iii) 25 mm
Supplying, fitting and fixing PVC pipes for underground work of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials, jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.) (i) 150 mm V/P-13, I-19(I)a. PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. V/P-36, I-2 ( PWD SOR (Sanitary & Plumbing)
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (c) 1000 litre capacity V/P-37, I-6 PWD SOR (Sanitary & Plumbing)
Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. V/P-37, I-10(i) PWD SOR (Sanitary & Plumbing)
Labour for punching hole in plastic water storage tank upto 50 mm dia V/P-38, I-13 PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (CERA/HINDWARE make) (i) 550 mm X 400 mm size V/P-41, I-2, PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. V/P-42, I-6.(b) PWD SOR (Sanitary & Plumbing) (b) Sink with drain board 1050 mm X 450 mm X 180 mm
CP Wall Mixture without spout but with provision for connnection to Telephone Shower and exposed pipe for Overhead shower (Equivalent to Code No. 5215 & Model - FLORENTINE of JAQUAR or similar brand). V/P-45, I-19.e.(ii) PWD SOR (Sanitary & Plumbing)
Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (ii) 100 mm dia. V/P-64, I-9.(ii) PWD SOR (Sanitary & Plumbing)
Supplying, fitting & fixing UPVC pipes B- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. V/P-68, I-23.A(c) PWD SOR (Sanitary & Plumbing).(A) (i) Single Socketed 3 Meter Length. (a) 75 mm. Dia.
(b) 110 mm. Dia.
(c) 160 mm. Dia
B) UPVC Fittings: (a) For Exposed Work.ii) Plain Tee.(a)75 mm. Dia.
(b) 110 mm. Dia.
(c) 160 mm. Dia
iii) Door Tee (a) 75 mm. Dia.
(b) 110 mm. Dia.
v) Plain Y .(a) 75 mm. Dia.
(b) 110 mm. Dia.
x) Bend 87.5 degree.(a) 75 mm. Dia.
(b) 110 mm. Dia.
(c) 160 mm. Dia
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap V/P-79, I-2.a. PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing glass shelf with aluminium guard rails. (a) Ordinary type with 5.5 mm sheet glass.(ii) 600 mm X 125 mm V/P-81, I-16.a.(ii) PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing soap holder. V/P-82, I-18.(a) PWD SOR (Sanitary & Plumbing).(a) PTMT (Prayag or equivalent)
Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm V/P-82, I-19, PWD SOR (Sanitary & Plumbing)
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass.(iii) 25 mm dia. and 600 mm long V/P-82, I-22.a.(iii) PWD SOR (Sanitary & Plumbing)
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. ii) With Bazree (N.B Variety) (SAIL/TATA/RINL) V/P-87, I-1.(ii) PWD SOR (Sanitary & Plumbing)
Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100 mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20 mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessary specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and filling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 30 users V/P-89, I-3.b.(iii) PWD SOR (Sanitary & Plumbing)
Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20 mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15 mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement concrete (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. V/P-89, I-4, 7th corrigenda, PWD SOR (Sanitary & Plumbing)With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL)
Roof treatment by application of non toxic polyurethane modified acrylic based single component (P U Roof Coat) solvent free, cold applied polyurethane modified elastomeric waterproofing memberance with exclent UV resistant capacity as per ASTM D6083 ( a water based 100% acrylic elastomeric emulsion polymer latex coating used as protective coating for roofs) after preparing the surface by cleaning and ti reparing the roof cracks by cement & sand mortar (1:4), preferably with antishrinkage mortar ( to be paid separately) if any, apply two coats along with a priming coat (two coats of P U Roof Coat and one coat of Primer coat compatible withg main product as per manufactures specifications) and reinforced with or without 20 gsm Geotextile Fleece, including the cost of primer coat and base preparation, tools and (Pllants but excluding the cost of scaffoolding and stagging complete as per direction Engineer-in-Charge. V/P-13th corrigenda Sl no.5, PWD SOR (Building)
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS:732-1983 and IS:1285-1975; Annodized (with required film thickness and specified colour/natural) matt finished conforming to IS:1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed/certified make and brand as per direction of Engineer-In Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white h) Louvered window i) Top, bottom and side member.
ii) Louvered Section.
iii) Cleat angle ( Non-annodized).
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for (A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sections, fabrications, including cutting to proper shape and size,drilling and aligning of window shutterframe fitted with inbuilt locking arrangements,sliding rollers and other necessary fittings,fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column,beam.lintels etc.)as well as between glas and shutter frame for fixing glass and Poly sulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw,cleat angle etc.but excluding the cost of extruded aluminium sections, glass, neoprene /EPDM gasket, locking arrangement and rollers.
Any other item not covered in this schedule wiil be applicable as per PWD Schedule of rate w.e.f 01.11.2017 , all Addenda & Corrigenda of SOR upto 08.03.2021
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers with sealing arrangement on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) Dimension of Al. bars [85mm long]: 4 x 20 x 5 mm Dimension of Sheet Metal Box: 500 x 150 mm
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. d) 2 x 56/0.3 (4 sqmm) + 1 x 22/0.3 (1.5 sqmm)
c) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 240 V DP with fuse on L&N [30/32 A]
Supplying and fixing MCB SS enclosure with IP 20/30 protection, power coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection and provision of earthing arrangement, 2 way
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection, 6-32 A DP
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casing-capping and Switch board both on surface] b) Average run 6 mtr
c) Average run 8 mtr
g) Average run 12 mtr
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] a) on board
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works, a) 4 Module
b) 6 Module
Supply & fixing 240 V, 6A modular type switch (Brand approved by EIC on existing GI modular type switch board having top cover plate and making necessary connections as required.
Supply & Fixing 240 V, 16A, 3 pin modular type plug socket with 16 A modular type switch (Brand approved by EIC) without plug top on 4 module GI modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply and fixing angular batten holder on 75 mm dia PVC round block / round bakelite on wall / ceiling
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works b) 25x10mm Size
Supplying of Exhaust Fan (9")
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: a) 23 cm (9")
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long), a) For 23 cm (9") Exhaust fan
Supplying of Exhaust Fan (12")
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: b) 30 cm (12")
Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long), b) For 30 cm (12") Exhaust fan
Excavation of soil for installation of earth electrode and filling & ramming a) for soft soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mtrs. Long and 1 x 4 SWG GI (hot dip) wire (4 mtrs. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 mtr. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtrs. below the ground level as below: b) By TATA-medium GI pipe
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
Add Cess @1%
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.88 MB
BOQ_2416065.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid